Optična spojka / Fiber Optic Closure 015Y1

Similar documents
Fiber Optic Splice Closure GPJ Instruction Manual

DOME OPTIC SPLICE CLOSURE

Gel-sealed in-line fiber optic closure

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Medium Box for Cable Termination

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Optical Distribution Box 300 Installation Guide. Version : R0.0

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Customer-Owned Outside Plant

FOSC 450 C6 and D6 Closures

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

3M Fiber Optic Closure System LL

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

3M Distribution Box (DDB)

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

HCS - HES Cabling Systems

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

SLiC Fiber Aerial Closure System

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

SPECIFICATION. Spec No : VSS-1402-CS603B

TECHNICAL SPECIFICATION

The FiberMark1 offers an ideal solution for

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

INSTALLATION INSTRUCTIONS

Instruction manual. Midi Fiber Dome. Instruction manual

2178-L/S Series Fiber Optic Splice Case with Gasket

3M Fiber Closures BPEO

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

Ordering Guide of the Fiber-Optic Splice Closure (FOSC-400)

Fiber Optic Closure. Fiber Optic Splice Closure For Aerial Line. Model : W-ICL-007-xxF. Features

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

INSTALLATION INSTRUCTIONS

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

INSTALLATION INSTRUCTIONS

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

e-enterable Fiber Optic Splice Closure (Re-Enterable Aerial Closure for Access Service)

IP-LINX Fiber :: X-XXXX

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

FOSC-450 Product Range Ordering Guide

Outside Plant. A comprehensive range of splice closures fully mechanical sealed for use underground, wall mounted and pole mounted.

FOSC 400. Fiber Optic Splice Closures

RetractaNet XS. Extractable Solutions for OSP. October 2012

Seal Kits for BUDI Enclosures

Connectivity accessories by Nestor Cables

IP-LINX. Installation Guide

3M Fiber Optic Wall Mount Enclosure 8430 Series

Splice Closure Fiber (SCF) Family

3M Better Buried Compound Compression Closure System

3 SLiC Aerial Closure with Rubber End Seal

3M Better Buried Closures

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX

2178 L/S Series Fiber Optic Splice Cases and Accessories

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

INSTALLATION INSTRUCTIONS MO023A

Cable installation guidelines

18mm ECAM Cable Entry Port

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

Data Sheet IP67 Mast Enclosure

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

3A TC 699/SIP/UK/12

27mm ECAM Double Cable Entry Port

Up to 85% higher Service Life due to efficient sealing method.

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

Ordering Guide. for FIST-GCO2 product range

FIST-GCO2 GCO2-BC8 GCO2-BD8 GCO2-BE8 GCO2-BF8. 5 Heatshrink installation. 1 Introduction. Content. 6 Fiber routing. 2 General. 7 Fiber routing on tray

7 Lighting Technology

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

Installation instructions Cable transit device Roxtec RS ES Ex

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

SECTION 4 TABLE OF CONTENTS

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

Public Works Division Lighting District Fiber Optic Specifications April 2009

FOSC 400. Fiber Optic Splice Closure. Features


Instructions. Cable with Armor F CAUTION. October Rev A

EXPlora. Introduction

KVT Split cable glands

SPECIFICATION. Optical Fiber Cable

FOSC 400 C5 & D5 Fiber Optic Splice Closures

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

KVT Split cable glands

3M Fiber Optic Splice Closure 2178 Family. Flexible Fiber. Management Solutions

Installation instructions Ex frames

FOSC 400 A4 Fiber Optic Splice Closure

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

Transcription:

1 Optična spojka / Fiber Optic Closure 015Y1 Data sheet with assembly tips Predstavitev Optične spojke uporabljamo za trajno spajanje vlaken in za odcepljanje vlaken ali kablov. Spoji so shranjeni v tesnjenem plastičnem ohišju. Spojka Fiber+ je zasnovana modularno. Sprejme lahko do 9 velikih kaset oziroma do 216 zvarov. Vsaka kaseta ima vgrajeni 2 držali za 12 oziroma največ 24 ščitnikov zvara. Spojka je primerna za navpično ali vodoravno uporabo, za montažo na drogove, na jeklene vrvi ali v jaške. Takoj po vhodu kablov v spojko so nameščene posebne spone iz Inox-a za pritrditev kevlarja ali razbremenilnih elementov. Spojka ima 4 okrogle vhode za kable premera 8-21mm, en okrogli vhod za kable 8-15mm in en ovalni vhod za 2 neodrezana kabla premera največ 25mm. Na voljo so različni dodatki in oprema. Introduction Fiber optic enclosures are used for permanent connecting and branching of fibers and fiber optic cables and are suitable for direct underground laying and outdoor installation. The special design provides for quick and easy installation. Consequently, trouble-free operation is guaranteed for several decades even for outdoor installations. The enclosure has separate strain relief points for central strength member and Kevlar reinforcement, 4 round entries for cables 8-21mm, one round entrie for cables 8-15mm and one oval entry for 2 uncut cables up to 25mm. With capacity up to 216 splices the Fiber+ splice enclosure is ideal for aerial and underground FTTx applications.

2 Features for aerial and underground applications an additional 35mm hole made through the plastic frame for easier access from one side to another innovative modular design complete scope of supply, ready for splicing easy fiber management for looping through resp. uncut fibers enough space for surplus fibers re-opening and sealing without special tools suitable for uncut cables cost effective rugged and compact design Možnosti / Configuration število kaset number of trays 12 zvarov na kaseto 12 splices per cassette 24 zvarov na kaseto 24 splices per cassette 1 12 24 Že vgrajeno v spojko / Scope of Supply 2 24 48 3 36 72 4 48 96 5 60 120 6 72 144 7 84 168 8 96 192 9 108 216 Cable and Port Preparation Prepare the cable according to the picture. Mark the cutting point on the cable at the length 1800mm. Remove the sheath of the cables from the marked point by stripper. Unlock the plastic hoop and separate the base and the body of the closure. Open required ports with suitable tool. Insert the prepared cable into heatshrink. Enter the cables into the opened ports of the closure.

3 Cable retention Fix the cables in to the base using cable clamps. Put the reinforcment or central strength member into the whole of the Inox bolt. Pull the reinforcment toward closure base plate and tighten the screw. Cut the protruding reinforcment approx. 10mm near the bolt. Mounting Shrink Tube Move heatshrink tube over and the cable into the port. For heat protection put foil over the adjacent ports. Hold the cable and the heatshrink in the right position an heat the heatshrink with a fan preferably even over the length and the perimeter. Do not heat too long over the port, because the heatshrink can move toward the cable. Stop heating if the glue leaks out of the heatshrink tube. Shrink all used ports.

4 Feeding Loose Tubes Use protective tube to enter grouped fibers into the splice tray, or use loose tubes of the cable as shown belove. Put the loose tubes entering from the bottom port with one loop. Put one loose tube into the cassette according to the picture, fix it with cable ties and feed the fibers in the inner channels. The sheet of splice tray can be used for the loose tubes protecting and grouping. Also surplus tubes/fibers can be wreathed or branched inside the sheet of splice tray. Installation of Fibers Stripped fibers are now operated inside the splice tray. The splice tray/cassette has integrated 2 splice holders, each splice holder module can accept up to 12 standard splice protectors 40 mm long, up to 6 splice protectors in each layer. After fiber splicing operation, please put the splice cassette cover onto the splice tray for protecting fibers.

5 Final steps Fix a drier at the splice tray holder by adhesive tape to keep the inside of the closure dry. Mount the rubber sealing ring to the base of the closure. Keep rubber sealing ring clean. Put the cover to the base of the closure and lock the plastic hoop. Fixing of the closure Use enclosed metal hoops for fixing the closure.

6 Vsebina dobave (015Y1) Ohišje s pokrovom in veznim obročem, tesnilna guma, montažni okvir, 2 kaseti, pokrov za kasete, sušilo, 4 toplo skrčne cevi za kable od 8 do 21mm, 1 toplo skrčna cev za ovalni vhod, zaščitne cevke za vlakna, klinasti vložek za ovalni vhod, dva kovinska obroča za montažo na steno ali drog, nalepke za označevanje, vezice, zaščitna folija, brusni papir in trak z ježi. Dodatne kasete od 1 do 7 (015Y2) z vgrajenimi držali za ščitnike zvara se naroča posebej. Scope of supply (015Y1) Base enclosure with locking ring, Sealing ring, Cassette support, 2 Splice Cassettes, Cassette cover, Drying agent, 4 heat shrink tubes for cable 8-21mm, 1 heat shrink tube for oval cable entry port, Fiber Protective Tubes, Branch clip, Metal hoop for mounting at poles or walls, Label paper, Cable fix ties, Tinfoil papers, Sand papers, and Splice trays Fixed band. Up to 7 additional splice cassettes with integrated splice holders must be ordered separately. Branch clip Protective tube Rubber sealing ring Heat shrink tube Drier Metal hoop Label paper Cable ties Tinfoil paper Sand paper Splice tray fixed band Port configuration Cable entry Qty Inner (mm) Length (mm) Suitable cable mm) R1 1 16 60 8-15 R2 4 22 60 8-21 OV 1 63 x 28 60 2 x (8-25)

7 Technical data Dimensions (DxL) 150 x 540mm Materials closure body thermoplastic PP; metal hoop steel; splice cassettes and fiber management thermoplastic ABS/PC flame-retardant; strain relief points Inox; sealing ring rubber Weight Approx. 3 kg Colours closure body black (RAL 9005); metal hoop galvanised steel; splice cassettes and fiber management signal white (RAL 1003) Bending radius limitation 35mm for fibers Installation temp. range -5 up to +45 C Operating temp. range -40 up to +60 C Atmospheric Pressure 70kPa~106kPa Protection class IP 68 Mechanical strength Load (1 min) 2000 N/m2 at centre of the enclosure Impact (3 times) 16 N.m Tight from -40 C to +65C Tightness with cable Strain (15 min) 800 N Shearing/bending (10 times) Deflection 45 or a max. of 150 N bending force Torsion (10 times) ±90 rotation angle or a max. torque of 50 Nm, Temperature changes -40 C to +65 C, 10 times Podatki za naročilo / Ordering information Koda / Item 015Y1 015Y2 Ime izdelka / Description kabelska spojka s priborom, vgrajeni 2 kaseti / splice closure with 2 cassettes and accessories dodatna kaseta za 12-24 zvarov / additional splice cassette for 12-24 splice protectors