RAILWAY SIGNALING & COMMUNICATION

Similar documents
OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

INTERFACING ETCS WITH LEGACY CC-SYSTEMS TRACK - SIDE

Competitive Trends in the Wire and Cable Industry by Gordon Thursfield Nexans North America. September 10, 2003 Presentation to ICC 0

ETCS INTERFACE WITH THE EXISTING SIGNALLING SYSTEMS

Digamber Telecom.

Bravo AV s Structured or Whole-House Wiring Approach

CONTENTS. Product Guide 1. Multi Conductor Cable 11. Paired Cable 20. RS-232 Application Cable 27. RS-422 Application Cable 28

NSW Submarine Telecom Systems. Turnkey solutions for the future, delivered today

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

Joint Safety and Security Analysis for Complex Systems. Sergey Bezzateev, Natalia Voloshina, Petr Sankin

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

1 Channel VGA Over Fiber Transmitter and Receiver Extender. User Manual L-1VGA-FE

384A Adapter Installation Instructions

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

Instrumentation & copper telecom cables

English version. Identification of cores in cables and flexible cords

SCALE & WEIGHT DISPLAYS

640 kv XLPE HVDC cable system

SIGNALING PRACTICES ON PROTOTYPE AND MODEL RAILROADS

FiberLink 7142 Series

- Outdoor & Indoor Telephone Cables - Fiber Optic Cables - Electronic Control Cables - Control Cables - Data/LAN Cables - Coaxial Cables

This brochure is printed with soy ink and environment-friendly paper.

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

The contribution of UNIFE: NGTC and STARS projects. Peter Gurník Technical Affairs Manager

Siam Pacific Electric Wire & Cable Co., Ltd.

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

Low Voltage Wires and Cables: New Applications for Thermoplastics

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

Above Ground Cable Installation Systems Selection Guide

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

OPTICAL FIBRE CABLE NETWORK 2004/1

This document is a preview generated by EVS

STANDARD FOR TELECOMMS WIRING AND TERMINATIONS

Smart [3] Elegant, efficient, versatile and safe.

L-BAND over Fiber Link TX/RX. User Manual. L-1Ch-L-Band-TX/RX

AN INTRODUCTION TO FIBER OPTICS SYSTEMS - PART II

SPAUN SOTx NF & SORx NF

Contact Details. British Transport Police: (24 hours) Crimestoppers: In association with:

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Instrumentation Cables

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by:

Ethernet over Coax HD IP camera technology using existing cables for analogue CCTV

Gear up for the future.

VersiVision. FVTMHA0xA / FVRMHA0xA 16-CHANNEL DIGITALLY ENCODED VIDEO 1-CHANNEL BI-DIRECTIONAL DATA MULTIPLEXER USER S MANUAL.

White Paper. Power over Coax. HDCVI technology evolution, Simplify wiring and maintenance. White Paper by Dahua Technology. Release 1.

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITHOUT METALLIC SCREEN

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

Laying of cables and lines in electrical installations and data networks

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Habiasense. Cables for measurement applications

Selecting the correct cable type for Outside Plant Application

LONWORKS Fibre Optic Converter

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

Engineering Instruction

TELSTRA VELOCITY HOME WIRING GUIDE BRING YOUR NEW HOME TO LIFE

SY-HDBT-SLIM-100S Extender Set

SPECIAL SPECIFICATION 6559 Telecommunication Cable

AMERICAN NATIONAL STANDARD

Rack mounted telephone- and leased line modem for industrial applications

Abhyudaya Marketing Solutions

Fibre Optic Modem ODW-622

SPECIAL SPECIFICATION 8540 Telecommunication Cable

Instrumental technique. BNC connector

CABLE FAULT LOCATOR MEGGER CFL510F (TDR1000/2)

VersiVision. FVTM2BBxA / FVRM2BBxA 2-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 2-CHANNELS BI-DIRECTIONAL AUDIO

LUDLUM MODEL ALPHA-BETA SAMPLE COUNTER SERIAL NUMBER PR AND SUCCEEDING SERIAL NUMBERS. February 2016

Cable installation guidelines

ODW-621. RS-232 Point-to-point applications

CABLE SIZE AND INSTALLATION GUIDE

E3/DS3 Fibre Extender

Metal Theft Taskforce Identification Booklet. Version 2

SWA Cable - BS5467 Steel Wire Armoured PVC Eland Product Group A9S

APPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them.

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

15.0 Overview Cross Connection Cabinet KVS Overview Polyester Production Cross Connection Cabinet Unicab Vario 8

Identification - electrical services

Msquare Innotech Solutions Pvt. Ltd. Complete integration of business solution. About Us: Mission:

2 x 58 W high frequency ballast for T8 fluorescent tubes based on L6562A, L6569, and STL11NM60N in PowerFlat HV package

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

Speed sensor MiniCoder GEL 2471

Telstra Velocity Home Wiring An essential guide for new home owners

MPS Webinar Technical Series

Arc-fault Protection System

Kuhnke Technical Data. Contact Details

Undergrounding HV and EHV Window of Opportunity Opens

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

CONTRACTORS SPECIFICATION

Arc Detecting and Protection System

Medium Voltage 12/20 (24)kV NF C cable system. Xavier Brosse Luanda May 2009

Cable solutions for all environments. Scapa Cable Solutions

White Paper. Fibre Optic Technologies for Satellite Communication and Broadcast Industries. By Tom Lacey Applications Engineering Group PPM Ltd, UK

HITRONIC Optical Transmission Cable

User Guide. Centrex Recording Interface

2011 The Practicalities of Fibre Deployment Colin Kirkpatrick

Features Horizon Electronic Marquee s Provide Years of Performance. spectrumhorizon.com

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

Transcription:

RAILWAY SIGNALING & COMMUNICATION

GENERAL CABLE SOLUTIONS FOR RAILWAYS APPLICATIONS General Cable manufactures an extensive range of cables for the railway industry. These infrastructures require a wide amount of different products for diverse applications. For these requirements, we consistently bring new innovative cabling concepts to the industry through better technology, superior safety, easier and faster installation and extended performance. General Cable is capable to supply energy, signalling, communication cables and components for all these installations. For the electrification system: all energy trackside cables, feeders and diverse LV, MV or HV cables used for the whole power system. For this signalling system: a vast range of multiconductors, multipairs, quads for most of the European standards or specifications. For the communication: fibre optics, telephone, coaxial radiating cables and structured cabling systems products for LAN uses such in stations, or WAN systems., For the reliability and security of railway infrastructures: balise cable for the European Rail Traffic Management System (ERTMS ). General Cable Europe & Med is homologated for most of major railway operator specifications including French standards (RATP, SNCF homologations), German standards for Deutsche Bahn (VDE homologations), Spanish standards for RENFE (ADIF homologations), British standard and many other standards for countries as Belgium, Romania,... For all products, we provide a long experience and know how in Low-Smoke, Halogen Free cables, strong fire performance, and electromagnetic protection. Moreover, General Cable's innovative technologies are the best in class for powering your light rail, transmitting safety information and data through reliable or high speed infrastructures. General Cable invests substantially in R&D to satisfy growing needs and solutions in the railway infrastructures, in order to be your key partner. We also are willing to cooperate in advising to engineering companies and operators to enhance specifications and standards.

RAILWAY SIGNALING & COMMUNICATION FRENCH STANDARDS ZPAU ZPAU-SH* ZC03 ZC03-SH* ZPFU ZPFU-SH* ZPGU ZPGU-SH* SNCF CT 445 SNCF CT 445 SNCF CT 445 Used for control and signalling circuits in railway networks. Connects the signalling equipment centre to the trackside equipment. Armoured cable along electrified lines. Cable with reduction factor. Used for control and signalling circuits in railway networks. Connects the signalling equipment centre to the trackside equipment. Armoured cable. Used for control and signalling circuits in railway networks. Cable for fixed equipment. Armoured cable. SPGU SNCF 698D Used for signalling circuits. Usually installed in conduits or overhead. T13 NF F 55-623 Used for signalling in tramway lines. Armoured cable. K23* NF F 55-623 K24* NF F 55-624 Halogen free cable used in tunnel for signalling, control and transmission in underground railway networks. Armoured cable. Halogen free cables used for telecommunications for local purposes in underground railway networks. K13 NF F 55-633 Used for signalling in metro, local trains and tramway lines. Armoured cable. ZUG ZUT SUG SCG SCG-S SCG-SH* CV ** CVZ** CV-S** CVZ-S** SRS-13* SNCF CT 455 SNCF CT 466 SNCF CT 500 RATP Specification Connects the internal equipment in signalling circuits. Cables for indoor usage. Used in signalling local circuits or power supply cables for trackside. Used for internal signalling circuits. Cables for indoor usage in traffic control centre and equipment shelter. Halogen free and watertight cable to install along the tracks. Armoured cable. K209B* RATP K209B Optical fiber cable used in long distances. Armoured cable CT2242 CT2243 SNCF CT2242 SNCF CT2243 Outdoor single trackside optical fiber cable for duct installation. Armoured cable. Outdoor single mode trackside optical fiber cable for open trench installation. K26* RATP K26 Coaxial and radiating 50 ohms cable. * Can be used in tunnels. **Halogen free version on demand.

RAILWAY SIGNALING & COMMUNICATION SPANISH STANDARDS EAP EAT* EAPSP EATST EAPSP (PI) EATST (PI)* EAPSP-8 EAPSP-R CCPSSP-FR CCTSST-FR* CCPSSP(PI) CCTSST(PI)* CCPSSP-R-FR CCTSST-R-FR* in ducts. into the ground or in ducts. Armoured cable. into the ground or in ducts. Armoured cable. Individual screening. Used for signalling circuits in railway networks. Self-supported cable. into the ground or in ducts. Jelly filled and armoured cable. into the ground or in ducts. Armoured cable. Cable with reduction factor. into the ground or in ducts. Armoured cable. Cable with reduction factor. Individual screening. into the ground or in ducts. Jelly filled and armoured cable. Cable with reduction factor. Individual screening. GERMAN STANDARDS A-2YY DLK 1.013.102y Used for signalling circuits in railway networks. A-2Y2YB2Y A-2Y(St)YBY A-2Y(L)2YV A-2Y(L)HV* A-2Y(L)HBH* AJ-2Y(L)2YDB2Y AJ-2Y(L)HDBH* AJ-2YOF(L)2YDB2Y DB AG 416.0113 DLK 1.013.107y DLK 1.013.201y in ducts. Armoured cable. in ducts. Armoured cable. Used for signalling circuits in railway networks. Reinforced sheath. in ducts. Armoured cable in Halogen free version. in ducts. Armoured cable. Cable with reduction factor. directly into the ground or in ducts. Jelly filled and armoured cable. Cable with reduction factor. * Can be used in tunnels.

RAILWAY SIGNALING & COMMUNICATION BRITISH STANDARDS AXLE COUNTER NR/L2/SIG/30060 Used for signalling circuits in railway networks. Used in axle counter system. UNIT TWIN COPPER TELECOMMUNICATONS NR/PS/TEL/00015 Used for communications in railway networks. Jelly filled cable. SCADA/PILOT NR/PS/ELP/27220 Used for modem based supervisory systems operating in the VF range from 300 to 3000 Hz. Jelly Filled cable. TWIN DATA LINK BR 1932 Used in connections for Solid State Interlocking (SSI) systems. G7621 A2 Type 1 LUL G7621 A2 Trackside communications cable used in open locations. G7621 A2 Type 2* LUL G7621 A2 Trackside communications cable used in tunnels or underground. G7622 A2 Type 1 LUL G7622 A2 Trackside communications cable used in open locations. G7622 A2 Type 2* LUL G7622 A2 Trackside communications cable used in tunnels or underground. G7623 A2* TYPE A1, A2 and A3 TYPE B1 and B2 TYPE C1, C2 and C3 TYPE D1 and D2 TYPE E1, E2 and E3 LUL G7623 A2 NR/PS/SIG/00005 Trackside communications cable used in tunnels or indoor applications. Used for signalling circuits in railway networks. Used in d.c. circuits where the nominal voltage to earth does not exceed 1100 volts. OTHER STANDARDS EUROBALISE SXCAV SXCAG* Specification INFRABEL S21 Used for control and signalling circuits in railway networks with reduction factor. Balise cable for ERTMS (European Rail Traffic Management System). Armoured cable. Used for control and signalling circuits in railways networks. Connects the signalling equipment centre to the track-side equipment. Armoured cable. Cable with reduction factor. CSYEY STAS 8779-86 Used for signalling circuits in railway networks. CSYEAbzY STAS 8779-86 Used for signalling circuits in railway networks. Armoured cable. CSYEAlAbzY-F STAS 8779-86 CS2XEAlAbzY STAS 8779-86 TCEKPFLEZE Specification Used for signalling circuits in railway networks. Aluminum wires screening. Armoured cable. Cable with reduction factor. Used for signalling circuits in railway networks. Aluminum wires screening. Armoured cable. Cable with reduction factor. Used for signalling circuits. Usually installed along the tracks into the ground or in ducts. Armoured cable. * Can be used in tunnels.

ALGERIA Tel.: +213 219 270 47/48 info@enicab.dz GERMANY Tel.: +49 699 593 24 30 info@generalcable-de.com NORWAY Tel.: +47 649 559 00 firmapost@generalcable.no SPAIN Tel.: +34 932 279 700 info@generalcable.es ANGOLA Tel.: +244 917 651 707 gccondel@condel-ao.com ITALY Tel.: +39 026 604 94 94 info@generalcable-it.com PORTUGAL Tel.: +351 219 678 500 info@generalcable.pt UNITED ARAB EMIRATES Tel.: +971 264 346 66 info@generalcable-ae.com EGYPT Tél.: +20 222 580 201 info@generalcable-eg.com MOROCCO Tel.: +212 522 865 300 info@generalcable-ma.com ROMANIA Tel.: +40 311 011 405 info@generalcable.ro UNITED KINGDOM Tel.: +44 (0) 1325 495370 info@generalcable.co.uk FRANCE Tel.: +33 (0) 160 573 000 info@generalcable-fr.com March 2015. General Cable. All rights reserved. GENERAL CABLE - Av. Marquês de Pombal, 36/38, 2715-055 Morelena-Pêro Pinheiro (Portugal) www.generalcable.pt All information in this catalogue is presented solely as a guide to product selection and is believed to be reliable. All printing errors are subject to correction in subsequent releases of this catalogue. Although General Cable has taken precautions to ensure the accuracy of the product specifications at the time of publication, the specifications of all products constainded herein are subject to change without notice.