Dimensions: 1.2 x 2.30 x..375 inches 31 x 59 x 9.5 mm Decoder version 3.5 $ This decoder is rated at 4 Amps

Similar documents
N14IP Decoder. $29.95 Decoder version 3.5. Direct plug in for Con Cor N-Scale PA1, and other locomotives with DCC 8 pin socket

Decoder version 3.5. Plug and play decoder for N-Scale Atlas Classic Series GP7, GP9, GP30, GP35

Z14SRP 4 Function Decoder with NMRA 8 pin plug

P2KSR Decoder $ Decoder version 3.5. This decoder is designed specifically to fit LifeLike HO Scale 0-8-0, GP7, GP9, GP30 and SD60 locomotives

$ Plug and play decoder for N-Scale Atlas H15-44 and H16-44

N12A0. $29.95 Decoder version 3.5 Dimensions: 2.65 x x.120 inches. 2 Function Decoder

SW9SR Decoder $ Decoder version 3.5. This decoder is designed for easy installation in Lifelike Proto 2000 SW8/SW9/SW1200 Locomotives

Technical Reference POWER PRO. Digital Command Control. ATLS4 Drop-In Decoder. (soldering required) Version 3.3 $29.95

Decoder BACH-DSL $ Decoder version 3.5. This Silent decoder is designed to replace the decoder in Bachmann DCC-EQUIPPED Diesel Locomotives

Light-It Decoder p/n Lighting decoder w/built-in white LED

Complete Train Control. Run Your Trains, Not Your Track!

Complete Train Control. Run Your Trains, Not Your Track!

DZ143. Z Scale. Mobile Decoder 1.25 Amp/2 Amp Peak 4 FX 3 Functions, 0.5 Amp. Fits Many Z, N and HO Scale Locomotives

Complete Train Control. Run Your Trains, Not Your Track!

DH163D Fits Many HO Locomotives

Complete Train Control. Run Your Trains, Not Your Track!

Atlas Drop In Decoder

Complete Train Control. Run Your Trains, Not Your Track!

LE1014W & LE1014MP Ultra-Thin Drive-Select DCC Decoder Art. No Version 4.6 April 2003

DN163K1C Fits Kato SD40-2 Phase 2 Locomotives (2009 onwards)

DH163L0 Fits LifeLike GP7, SD60 and Other Locos with LifeLike DCC medium plug arrangement.

DH163A0 Fits Athearn Genesis, Kato, Stewart, Atlas & Other HO Locomotives

DH165A0 Fits Athearn, Genesis, Kato, Stewart, Atlas & Other HO Locomotives

21-Pin Connector. Dimensions: 1.28 x.69 x.22 or 32.5mm x 17.5mm x 5.6mm

DH165K1A Board Replacement Decoder Fits Kato SD40-2, AC4400 Locos

DN163K0b. N Scale. Mobile Decoder DCC Plug N Play 1.0 Amp/2.0 Amp Peak 6 FX 3 Functions, 0.5 Amp. Fits Kato N-F3 A&B and Other Locomotives

Main Features of this Decoder

DN163A0 Fits Atlas N-Scale GP40-2, U25B, SD35, Trainmaster & B23-7 Locos

HO-Scale Athearn DCC Sound Conversion Kit

HO-Scale Kato DCC Sound Conversion Kit

Visit our Page LaisDcc TM Decoders Manual

DN123K3 Fits Kato NW-2 N Scale Locomotives

LE062XF DCC Decoder for Atlas N Scale Locomotives

LF101XF Six Function DCC Function Only Decoder Art. No February 2007

GAUGEMASTER PRODIGY EXPRESS

Blackstone Models Open Platform Passenger Coach and Long Caboose Lighting Decoder Technical Reference

DZ123Z0 Fits AZL Z GP-30 and others

MC1 Series Technical Reference

Diesel Technical Reference

User s Guide For the Blackstone Models Open Platform Passenger Coach and Long Caboose Lighting Decoder

MC2 Series User s Guide

TM Load-regulated locomotive decoder

Technical Reference Software Release 1.00

MC1 Series User s Guide

Econami Digital Sound Decoder Electric User s Guide Software Release 1.3

17.2 Setting the slow speed Important advice on ABC Push-pull (shuttle) train control Push-pull operation without

DCC Decoder. Instructions

Econami Digital Sound Decoder Diesel User s Guide Software Release 1.5

Version1.0-02/08. emotion L Decoder

Quick Start Guide. For Bachmann Large Scale Thomas & Friends Sound-Equipped Locomotives. DCC Sound Technology by SoundTraxx

RENFE TAF / CP FOGUETE References: & 47023

DR4018 DIGISWITCH HANDLEIDING / MANUAL BEDIENUNGSANLEITUNG / MANUEL. DR4018 DIGISWITCH (v1.2) V1.2 ( )

Signalist SC1. DCC signal controller user manual Covers configuration for UK signals

Information LG100 Brake Module

Tsunami Digital Sound Decoder SoundCar User s Guide

MRC Prodigy Advance 2. User s Manual

MRC DISPATCHER TRACKSIDE DECODER

Econami Digital Sound Decoder Steam Quick Start Guide Software Release 1.3

DCC Install Primer. Victor Pinamonti

Turnout Decoder TD Maxi. User Manual - version 0.1.6

GAUGEMASTER PRODIGY ADVANCE --- WIRELESS ---

Diesel Sound User s Guide

Rev. A 6/27/16. Tsunami2 Digital Sound Decoder Electric User s Guide Software Release 1.0

Pixel LED SPI Digital Controller

INPUT OUTPUT GAIN DELAY. Hue Candela Strobe Controller. Hue Candela s STROBE CONTROLLER. Front Panel Actual Size 7 ¼ By 4 ¾ POWER. msec SEC 10 1.

EPIC'S RS232 PRO. Specifications External power supply - (power supply sold seperately) Output: 8-24V DC (depends on input) DC Per Channel

16 Stage Bi-Directional LED Sequencer

KNX Dimmer RGBW - User Manual

APOLLO DESIGN TECHNOLOGY 4130 Fourier Drive Fort Wayne, IN USA Phone: Fax:

National Model Railroad Association (NMRA) Inc. Digital Command Control (DCC) Baseline Mobile And Accessory Decoder Test Procedures

STX Stairs lighting controller.

Dimming actuators GDA-4K KNX GDA-8K KNX

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

2002 Martin Professional A/S, Denmark.

For warranty service, please contact Microframe at: A technician will gladly assist you.

User Manual. LokSound2. Version 1.0 January 2002

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

FD400Multi Function Decoder. User Manual. 04/2013

Aspect 2 Circuit Digital Scene Control

34MD Series. Motor/Driver Combination. User s Guide E. Landon Drive Anaheim, CA

LED PAR 36 USER MANUAL

Multi-Zone Programmable RGB ColorPlus LED Touch Controller (Remote Control) and RGB ColorPlus LED Touch Controller (Receiver)

Understanding VFD. Variable Frequency Drive. nfi. nfi

ESU LokSound Select Direct Micro "Keep-Alive"

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

XTAL Bank DDS Version 0.02 Sept Preliminary, highly likely to contain numerous errors

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

SceneStyle2 User Guide

LokPilot V4.0. Instruction Manual. LokPilot V4.0. LokPilot V4.0 DCC LokPilot micro V4.0 LokPilot micro V4.0 DCC

Owners SW-LCD 2.0 Manual & Specifications

Programmable Micro Remote LED Controller for RGB LED Strips - 12 or 24 VDC Part number: PMRC

POINTS POSITION INDICATOR PPI4

OPERATING MANUAL. DMX LED Current Dimmer 5004A-EP Mk2

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

LCD STIMULUS DISPLAY for ENV-007/008 CHAMBERS

Azatrax Model Railroad Track Signal Control - Single Track

BLOCK OCCUPANCY DETECTOR

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

User Manual. LokSoundXL. Version 2.1 May 2002

Transcription:

D0SR Amp Decoder Dimensions:. x.30 x..375 inches 3 x 59 x 9.5 mm Decoder version 3.5 $9.95 This decoder is rated at Amps This is an EPF (extended packet format) decoder supporting: Silent Running TM High frequency motor drive eliminates motor hum or buzz Torque Compensation for ultra smooth low speed performance Programmable Start, Mid and Maximum speed works for all speed modes Motor rating Amp continuous, 0 Amp peak (stall) 9 function outputs - two rated at ½ Amp. Select from 5 different lighting effects (Mars, strobes, beacons, flicker, etc) Function outputs can be mapped to different functions (highly compatible with Soundtraxx TM DSX decoders) Two or Four digit addressing Uploadable speed table interpolated to speed steps and Speed mode operation (always works internally at 56 steps) Decoder assisted consisting Supports all forms of DCC programming New decoder programming lock mechanism This decoder is not warranted for use in USA Trains or Charles Ro G Gauge locomotives Every attempt has been made to ensure this decoder complies with all applicable NMRA Standards and Recommended Practices. Website: www.ncedcc.com This book, schematics and artwork copyright 003 NCE Corporation Webster, NY 50

Decoder Installation Notes: Note: This decoder is covered in clear heatshrink tubing that is designed to keep the aluminum heatsink plate attached to the bottom of the decoder. Do not remove this tubing. The most important part of a successful decoder installation is proper isolation of both motor brushes from the track so that they are driven only by the decoder. Failure to isolate the motor will definitely damage the decoder. Damage caused by failure to isolate the motor is not covered by the decoder warranty. DC BRUSH MOTOR RED Right Track Power Pickup ORANGE Motor + GRAY Motor - BLACK RIGHT RAIL (Engineer's Side) Left Track Power Pickup LEFT RAIL (Fireman's Side) WARNING: To prevent decoder damage: always make sure the motor brushes are properly insulated from thetrack pickup Before applying power Before test running your newly converted locomotive on full power double check your wiring to make sure the motor is fully isolated and that there are no pinched or broken wires. We see many decoders returned due to wires getting pinched between the body shell and frame causing shorts. Always test your decoder installation on an current limited programming track before trying it on full track power. We recommend that the first "full power" testing be done on regular DC. If the pickup polarity is reversed you will want to correct this for proper analog mode operation. The decoders should be driven by a good quality smooth DC power unit. Power packs with pulse power systems such as "tracking control", etc. will give unpredictable operation. Analog operation is included in NCE decoders so you will be able to run on conventional DC layouts without having to remove the decoder or rewire your locomotive. Function Connection Diagram OUTPUT 9 Solder Pad OUTPUT Solder Pad D0 DECODER 9 Pin Connector BLUE WHITE GREEN VIOLET BROWN WHITE/YELLOW WHITE/GREEN YELLOW BLUE COMMON OUTPUT OUTPUT OUTPUT 3 OUTPUT OUTPUT 5 OUTPUT 6 OUTPUT 7 COMMON Last revised: March 006 D0SR Page

Fine tuning locomotive operation The factory settings normally provide good performance for most locomotives in HO-Scale. You may want to improve or fine tune performance by adjust the starting characteristics or top speed. There are 6 CVs that define: The voltage at which the motor starts How often and how hard the motor gets kicked a slow speeds to keep it turning smoothly. The maximum motor speed The mid speed range response characteristics or speed curve. Compensation for a motor that runs faster in one direction Start Voltage - CV (Vstart): This is the amount of voltage sent to the motor when first starting up. We set CV so the locomotive is almost able to maintain movement at speed step. We then use CV6 and 7 to apply enough torque compensation to keep it turning on speed step. Typical values for CV are in the range of 0-35. Torque compensation kick rate - CV6: How frequently the motor is kicked at slow speed. Typical adjustment is to. The smaller the number the more often the motor gets a brief voltage kick. Factory default is 0 (off). A value of applies kicks continuously. The maximum practical value is about 6. Torque compensation kick strength - CV7: How hard the motor is kicked at slow speed. Typical adjustment is to 5 The larger the number the more voltage is applied in each kick. The strength of these kicks fade out ratiometrically as speed is increased providing a smooth transition to normal motor operation. Factory default is 0 (off), usable range 0-50. Vmax - CV5: If your locomotive runs too fast you can use CV5 to lower its maximum speed. Setting CV5 to 55 uses the maximum possible voltage to run the motor when full speed is requested. Set CV5 to a smaller value to reduce the top speed. A value of will yield approximately ½ full voltage to the motor at top speed. 9 will provide about ¾ full voltage. All speeds from the middle speed step to the maximum will be proportionally reduced (see diagram). If CV5 is set to 0 the decoder will use 55 for maximum speed. Always make sure CV5 is greater than CV6 to avoid erratic operation. Vmid - CV6: CV6 determines how the motor responds through its middle speed ranges to advancement of the throttle. If you set CV6 lower than half the maximum speed you ll have smaller increases in motor speed through the lower speed ranges. Then, as you hit the upper speed ranges there will be larger increases between speed steps. In the diagram below you can see this best illustrated by the customized line. If you set Vstart larger than 0 you ll will most likely want to raise Vmid so a reasonable slope is maintained in the speed curve. If CV6 is set to 0 the decoder will use 7 as the value. If you use high values in CV7 you will want to increase CV6 by a proportional amount to keep a smooth acceleration curve. Reverse trim (also forward trim) - CV95: Values from -7 make decoder run faster in reverse than forward. is one speed step faster in reverse, is two steps faster, etc. Values from 9-55 make decoder run faster in forward than reverse. 9 is one speed step faster in forward, 30 is speed steps faster, etc. 0 and add nothing to either direction. 55 factory default 9 Vmax customized Voltage 06 Vstart Vmid Motor 'Speed Curve' 000 3 6 96 Speed steps Last revised: March 006 D0SR Page 3

Function mapping and effects programming examples Ditch lights: What we want to do: Use outputs 3 and (violet and brown wires) for the left and right ditch lights They will be controlled by F which is the HORN button on most DCC systems They should continue flashing for 5 seconds after the HORN button is released How to do it: Program outputs 3 and to both be activated by F. Set the F mapping CV (CV36) to (0C hex). We get the value of by adding the bit weights for output 3 and output on the F line of the CV mapping table on page 5. Program outputs 3 and for ditch light operation. Set CV3 to 56 and CV to 60. Using these values the lights will be qualified by the headlight AND function. The headlight must be on for the ditch lights to be activated by F. Type ditch lights are on constantly on when the headlight is on and alternately flash when the horn is blown. Type ditch lights are normally off until the horn is blown. This example is for the more common Type. If you prefer Type use EFX values 5 and instead of 60 and 56. CV sets the amount of time the ditch lights stay flashing after the horn (F) is deactivated. The time is measured in / second intervals, for a hold time of 5 seconds put a value of 0 in the CV. One last thing: Set CV35 to 0 so output is not also controlled by F3. Mars Light: What we want to do: Use output (green wire) for the Mars light. It is to be on in the forward direction only How to do it: Output is already activated by F (factory default setting of CV35=). Configure output as a forward only Mars light. Set CV to 9. We get the value of 9 by using (Mars Light) plus (output operates only in forward direction) Rule 7 lighting: What we want to do: Use output (white wire) for the Headlight Headlight is to be on bright in both directions of travel We also want to dim the headlight How to do it: Output is already activated by F0 (factory default setting of CV33 =). Configure output as a standard output, on in both directions, yet dimmable when F is activated. Set CV0 to 3 (0 hex). You can optionally set CV0 to 36 is you want F to control the dimming instead of F. Switcher: What we want: Headlights that dim in the opposite direction that the locomotive is travelling Use output (white wire) as Headlight and 7 (yellow wire) as Rearlight How to do it: Output and 7 are already activated by F0 due to the factory default settings. Configure output as bright in forward dim in reverse. Set CV0 to (C hex) Configure output as bright in reverse dim in forward. Set CV6 to 0 ( hex) Last revised: March 006 D0SR Page

Description of EFX configuration CVs CV0 - Lighting effect configuration for output (white wire). CV - Lighting effect configuration for output (green wire). CV - Lighting effect configuration for output 3 (violet wire). CV3 - Lighting effect configuration for output (brown wire). CV - Lighting effect configuration for output 5 (white/yellow wire). CV5 - Lighting effect configuration for output 6 (white/green wire). CV6 - Lighting effect configuration for output 7 (yellow wire). CV7 - Lighting effect configuration for output (solder pad). Output 9 has no lighting effects - it is standard on/off control Each output wire can select from 5 different lighting effects by using its associated EFX configuration CV. Pick the value for the CV from the table below, add or if you want the effect to be directional (footnotes and 3), then add if you are using a white LED for the effect. Ditch lights should not be made directional, they re not dierectional in real life. bit weight 6 3 6 bit name LED --- Effect configuration REV FWD 3 Value for CV 0 6 0 3 36 0 5 56 60 Description of lighting effect Standard on/off function output Firebox flicker (brighter when accelerating) Mars light Rotary Beacon Gyralight Double Strobe Strobe A Strobe B (alternates with Strobe A) Dim when F0 and F on, otherwise bright Dim when F0 and F on, otherwise bright Dim in forward, bright in reverse Dim in reverse, bright in forward Type Right Ditch light, effect on if F on, output off otherwise Type Left Ditch light, effect on if F on, output off otherwise Type Right Ditch light, effect on if F0 and F on, bright if F0 on and F off, off if F0 off Type Left Ditch light, effect if F and F0 on, bright if F0 on and F off, off if F0 off Hex (for Digitrax users) 0 0C 0 C 0 C 30 3 3 3C - Functions are designed to use -6 volt 30-0ma incandescent lamps. If you are using a white LED (with K limiting resistor) add to the CV value. - If you want the function to be active only in the reverse direction add to the CV value 3 - If you want the function to be active only in the forward direction add to the CV value Last revised: March 006 D0SR Page 5

Description of function mapping CVs: Function mapping can change which output wire(s) are controlled by a function command from your handheld cab. It is possible to have one command control several outputs. In the tables below each row corresponds to a function mapping CV and each column indicates an output number. A under an output number means that output will be controlled by the function corrsponding to the row. In the table below the factory value of CV33 is which means F0 will control Output #. The tables below show the original factory settings for each mapping CV. The NMRA recommended practices do not provide for mapping all functions to all outputs. The tables below are the prescribed function mapping dictated by NMRA RP-9... Note: In this decoder CV33 and CV3 operate identically. They are not directional...directionality is provided in the EFX configuration CV for each output. Factory default function mapping values OUTPUT NUMBER 9 7 6 5 3 Solder pad Solder pad Yellow wire White/Green White/Yellow Brown wire Violet wire Green wire White wire CV33 F0 Fwd 6 3 6 CV3 F0 Rev 6 3 6 CV35 F 6 3 6 CV36 F 6 3 6 CV37 F3 6 3 6 CV3 F 3 6 CV39 F5 3 6 CV0 F6 3 6 CV F7 CV F CV3 F9 CV F0 CV5 F CV6 F Recommend dropping resistors if using.5 volt bulbs Track Voltage Bulb Current.5 3 3.5.5 5 5.5 6 Wattage 5ma 60 60 70 750 0 0 90 90 ¼ watt 30ma 330 360 360 390 390 30 30 70 ½ watt 0ma 0 70 70 300 300 300 330 330 watt 50ma 00 00 0 0 0 0 70 70 watt 60ma 60 0 0 00 00 00 0 0 watt 0ma 0 30 30 50 50 60 60 60 watt Last revised: March 006 D0SR Page 6

CV 3 5 6 7 9 3 9 30 33 3 35 36 37 3 39 0 3 5 6 67 6 69 70 7 7 73 Default value Description CV Default value Description Factory default values for decoder Configuration Variables (CVs) decimal hex decimal hex 3 03 short address 7 0 0 alt spd table step 0 00 start voltage 75 0 0 alt spd table step 9 0 00 acceleration 76 0 0 alt spd table step 0 0 00 deceleration 77 0 0 alt spd table step 0 00 Maximum speed 7 0 0 alt spd table step 0 00 Mid speed 79 0 0 alt spd table step 3 9 C0 long address high byte 0 0 0 alt spd table step 0 00 long address low byte 0 0 alt spd table step 5 0 00 consist address 0 0 alt spd table step 6 55 FF consist functions F-F 3 0 0 alt spd table step 7 63 3F consist function FLF,FLR 0 0 alt spd table step 0 00 acceleration adjust 5 0 0 alt spd table step 9 0 00 deceleration adjust 6 0 0 alt spd table step 0 0 decoder configuration 7 0 0 alt spd table step 0 00 reset register 0 0 alt spd table step 0 Output(s) controlled by F0 9 0 0 alt spd table step 3 6 0 Output(s) controlled by F0 90 0 0 alt spd table step 0 Output(s) controlled by F 9 0 0 alt spd table step 5 0 Output(s) controlled by F 9 0 0 alt spd table step 6 Output(s) controlled by F3 93 0 0 alt spd table step 7 0 Output(s) controlled by F 9 0 0 alt spd table step 0 Output(s) controlled by F5 95 0 0 Reverse trim 6 0 Output(s) controlled by F6 6 0 0 Kick rate 0 Output(s) controlled by F7 7 0 0 Kick strength 0 0 Output(s) controlled by F 0 Ditch light hold time 0 0 Output(s) controlled by F9 9 55 FF EFX page access 0 0 Output(s) controlled by F0 0 0 Output EFX generator 0 0 Output(s) controlled by F 0 0 Output EFX generator 0 0 Output(s) controlled by F 0 00 Output 3 EFX generator 0 0 alt spd table step 3 0 00 Output EFX generator 0 0 alt spd table step 0 00 Output 5 EFX generator 0 0 alt spd table step 3 5 0 00 Output 6 EFX generator 0 0 alt spd table step 6 6 0 Output 7 EFX generator 0 0 alt spd table step 5 7 0 00 Output EFX generator 0 0 alt spd table step 6 0 0 alt spd table step 7 Table of commonly used values for CV9 Value for CV9 decimal hex 0 6 6 6 3 3 6 50 3 5 36 Long/Short Address Short Short Short Short Long Long Long Long Uploadable/Factory Speed table Factory Factory Uploadable Uploadable Factory Factory Uploadable Uploadable Analog (DC) operation no yes no yes no yes no yes Speed mode / / / / / / / / Hex numbers are provided for early Digitrax users Notes: If you want to reverse the direction of travel on DCC increase the value for CV9 by one (this also reverses all directional lighting). If you want to reverse the DC direction reverse the track pickup wires. Last revised: March 006 D0SR Page 7

Configuration Variables used by V3.5 Decoders CV Short decoder address; -7 valid CV Start Voltage (useful range 0-00) CV3 Acceleration rate (each unit = 7mS between speed steps) 55 max. CV Deceleration rate (each unit = 7mS between speed steps) 55 max. CV5 Vmax, speed at highest speed step. 0=use factory default of 55 CV6 Vmid, speed (on a scale of -55) at speed step 7,,or 63. 0=use default of 7 CV7 Decoder version number. This decoder is 35 which means version 3.5 CV Manufactuer ID. NCE = (0B hex) CV Packet timeout value (in ½ second increments) Time the decoder will wait before braking to a stop after running into a section of track with DC power. 0=Don t brake CV5 Decoder programming lock KEY. This CV is always programmable even when locked CV6 Decoder programming lock ID. When CV5=CV6, programming is unlocked and the decoder will respond to programming commands. If CV5 is not equal to CV6 then decoder programming is locked and it will not program (except CV5) or read. CV7 High byte of long ( digit) address - bit 6,7 always= - bits 0-5 are upper 6 bits of address CV Low byte of long ( digit) address CV9 Consist address. (0 or = no consist active) - bits 0-6 short consist address (-7 valid) - bit 7 0= direction is normal, = direction is reversed CV Functions active in consist mode. Bit 0 controls F,bit =F, bit =F3, etc. - bit 0 - =function can be controlled at consist address, 0 = no consist control CV Functions active in consist mode. Bits 0, control FLF and FLR respectively each bit =function can be controlled at consist address, 0 = no consist control CV9 - bit 0 = direction of operation is reversed, 0= direction is normal - bit = speed mode (always enabled) - bit = analog operation mode enabled, 0 = disabled - bit = alternate speed table active, 0= use table defined by CV,5,6 - bit 5 = use long address in CV7/, 0= use short address CV - bits 3,6,7 are ignored by the decoder CV30 Set this CV to on the programming track and the decoder will reset to factory settings. CV33-CV6 function mapping CVs for F0-F CV67-CV9 Uploadable speed table steps - ( speed mode calculates intermediate steps) CV95 Reverse trim, values -7 add to reverse speed, values 9-55 add to forward speed CV6 Torque kick rate - number of 6ms periods in a row that motor is kicked with voltage pulse CV7 Torque kick strength - how much voltage is used to kick the motor at slow speeds. Reduces to 0 as speed is increased. CV Ditch light hold time (in ¼ second increments) after F goes off. CV0-CV Effects configuration registers for outputs - CV NOTES: All CV numbers not listed above are ignored. This decoder supports all DCC programming methods. Formula for computing the long address if using a Lenz System: If using a Lenz SET0, SET0, SET90, SET00 or other entry level system, use paged programming mode and see the note below for programming long addresses. CV7 = 9 + (the whole number portion of the long address divided by 56) CV = the remainder of the long address divided by 56 CV9 = 3 if analog mode disabled, 3 if analog mode enabled Decoder Warranty This decoder is fully factory tested and warranted against manufacturing defects for a period of year. As the circumstances under which this decoder is installed can not be controlled, failure of the decoder due to installation problems can not be warranted. This includes misuse, miswiring, operation under loads beyond the design range of the decoder or short ciruits in the locomotive manufacturer s factory wiring. If the decoder fails for non-warranted reasons NCE will replace D0 decoders, no questions asked, for $5 U.S. plus $ shipping. For warranty or non-warranty replacement send the decoder (and any payment, if required) to: NCE Warranty Center 99 Ridge Road Webster, New York 50 Bar Code The terms Silent Running, Powerhouse Pro, Power Pro, Powerhouse Digital Command Control, ProCab, Smartcab, Switch-It, Snap-It, the NCE logo with Power of DCC slogan and EFX are trademarks of NCE Corporation. Digitrax is a trademark of Digitrax Inc. Last revised: March 006 D0SR Page