100MHz 2[4] Channel Digital Oscilloscope HMO1022 [HMO1024]

Similar documents
350MHz 2[4] Channel Digital Oscilloscope HMO3522 [HMO3524]

Oscilloscopes. the new hmo 3000 SerieS 300 Mhz 400 Mhz 500 Mhz

Great Value in Test & Measurement. Mixed Signal Oscilloscopes HMO 3000 SerieS 300 MHz 400 MHz 500 MHz

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

Mixed Signal Oscilloscopes 300 MHz 400 MHz 500 MHz HMO3000 Series

HMO3000 Series Mixed Signal Oscilloscopes 300/400/500 MHz Bandwidth

Digital Storage Oscilloscopes 2550 Series

R&S HMO3000 Series Mixed Signal Oscilloscopes 300/400/500 MHz Bandwidth

SDS1000C Specifications

R&S HMO1002, R&S HMO1202 Two-channel digital oscilloscopes 50 MHz to 300 MHz bandwidth. Test & Measurement Product Brochure 02.01

R&S HMO1002 Digital Oscilloscope 50/70/100 MHz Bandwidth

R&S HMO3000 Series Mixed Signal Oscilloscopes 300/400/500 MHz Bandwidth

Spectrum Analyzer 1.6 GHz 3 GHz HMS-X

Max. sampling rate (realtime) channel. interleaved. 1 Gsample/s. interleaved. 2.5 Gsample/s per channel 5 Gsample/s. 5 Gsample/s per channel

R&S HMO Compact Series Mixed Signal Oscilloscopes 70/100/150/200 MHz Bandwidth

R&S HMO1002, R&S HMO1202 Two-channel digital oscilloscopes 50 MHz to 300 MHz bandwidth

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Product Brochure Test & Measurement. R&S HMO1002 Digital Oscilloscope 50/70/100 MHz Bandwidth

DataSheet. SDS1000DL Series Digital Oscilloscope

Agilent Technologies 54522A

Expect to Make Waves.

2016 RIGOL TECHNOLOGIES, INC.

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

ADS1000C, CAL / CML Series

Portable Performance for Debug and Validation

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

50 MHz Digital Storage Oscilloscope

SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz

DataSheet SDS1000CFL Series Digital Oscilloscope

ScopeMeter 190 Series Specifications

DataSheet SDS1000CML Series Digital Oscilloscope

MHz Digital Oscilloscope HMO Series 72x...202x

Digital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

250/350 MHz Digital Oscilloscope HMO Series

SDS1000CNL+ Series Digital Oscilloscope. DataSheet

WaveSurfer MXs. The Specs You Want The Features You Need 200 MHz to 1 GHz

Digital Oscilloscope. Characterisation, Measurement & Analysis

2 MHz Lock-In Amplifier

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

SX-METRO A software package to meet all your needs

R&S RTB2000 Digital Oscilloscope Specifications

What is oscilloscope? What an oscilloscope looks like. Oscilloscopes, accessories, applications Ján Šaliga

R&S RTM Digital Oscilloscope Specifications

~.Yr / 12. Offset range: ±2 V (2 mv/div to 200 mv/div), ±SO V (> 200 mv/div to 5 V/div) "digital storage oscilloscope" 13.

SDS1000DL+/CML+ Series Digital Oscilloscope. DataSheet

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

R&S RTC1000 Oscilloscope Specifications

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

WAVERUNNER 104XI AND 204XI


R&S RT-Zxx High-Bandwidth Probes Specifications

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Meeting your needs R&S RTO2000 Digital Oscilloscope

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE

4 MHz Lock-In Amplifier

PicoScope 6000 Series HIGH-PERFORMANCE USB OSCILLOSCOPES

Agilent Series Oscilloscopes

R&S RTB2000 Digital Oscilloscope Power of ten

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

5 Series MSO Serial Triggering and Analysis Applications 5-SRAUDIO, 5-SRAUTO, 5-SRCOMP, and 5-SREMBD Datasheet Serial triggering

High Speed Data Acquisition Cards

R&S RTM Digital Oscilloscope Scope of the art

Advanced Test Equipment Rentals ATEC (2832)

R&S RTB2000 Digital Oscilloscope Power of ten

3000 Series. PicoScope. USB oscilloscopes

Data Pattern Generator DG2020A Data Sheet

Agilent 6000 Series Oscilloscope Demo Guide

Programmable Power Supplies 188 W 384 W R&S HMP Series

PicoScope 3000 Series

GDB-03 Demo Module USER MANUAL GW INSTEK PART NO. 82DB-03000M01 ISO-9001 CERTIFIED MANUFACTURER

2000 Series. PicoScope. The compact alternative to a benchtop oscilloscope

DSO7032A Oscilloscope: 350 MHz, 2 channels

PicoScope 6407 Digitizer

R&S RT-Zxx High-Voltage and Current Probes Specifications

Agilent 54610B, 54615B and 54616B 500 MHz Oscilloscopes

R&S RTO Digital Oscilloscopes Scope of the art

2 MHz Lock-In Amplifier

WaveSurfer MXs-B and MSO MXs-B Oscilloscopes

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

User Manual. Digital Oscilloscope V1.9

Keysight Technologies CAN/LIN Measurements (Option AMS) for InfiniiVision Series Oscilloscopes

Using an oscilloscope - The Hameg 203-6

Agilent InfiniiVision 7000 Series Oscilloscopes

WaveSurfer 3000 Oscilloscopes 200 MHz 500 MHz

R3267/3273 Spectrum Analyzers

Transcription:

100MHz 2[4] Channel Digital Oscilloscope HMO1022 [HMO1024] HMO1024 Carrying Case HZO90 Component Tester/Bus Signal Ethernet/USB Dual-Interface HO730 (Option) R 2 GSa/s Real Time, Low Noise Flash A/D Converter (Reference Class) R 2 MPts Memory, Memory oom up to 50,000:1 R MSO (Mixed Signal Opt. HO3508) with 8 Logic Channels R Serial Bus Trigger and Hardware accelerated Decode incl. List View. Options: I 2 C + SPI + UART/RS-232, CAN/LIN R Automatic Search for User defined Events R Pass/Fail Test based on Masks R Vertical Sensitivity 1 mv/div. R 12 div. x-axis Display Range, 20 div. y-axis Display Range (VirtualScreen) R Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event R Component Tester, 6 Digit Counter, Automeasurement: max. 6 Parameters incl. Statistic, Formula Editor, Ratiocursor, FFT: 64 kpts R Fan: Silence redefined R 3 x USB for Mass Storage, Printer and Remote Control

100 MHz 2 [4] Channel Digital Oscilloscope HMO1022 [HMO1024] Firmware: 4.522 All data valid at 23 C after 30 minutes warm-up. Display Display: 16.5 cm (6.5") VGA Color TFT Resolution: 640 x 480 Pixel Backlight: LED 400 cd/m 2 Display area for traces: without menu 400 x 600 Pixel (8 x 12 div.) with menu 400 x 500 Pixel (8 x 10 div.) Color depth: 256 colors Intensity steps per channel: 0 31 Vertical System Channels: DSO mode CH 1, CH 2 [CH 1 CH 4] MSO mode CH 1, CH 2, LCH 0 7 (Logic Channels) [CH 1, CH 2, LCH 0 7, CH 4] with Option HO3508 Auxiliary input: Frontside [Rear side] Function Ext. Trigger Impedance 1 MΩ 13 pf ±2 pf DC, AC Max. input voltage 100 V (DC + peak AC) XYZ-mode: All analog Channels on individual choice Invert: CH 1, CH 2 [CH 1 CH 4] Y-bandwidth (-3 db): 100 MHz (5 mv 10 V)/div. 20 MHz (1 mv, 2 mv)/div. Lower AC bandwidth: 2 Hz Bandwidth limiter (switchable): approx. 20 MHz Rise time (calculated): <3.5 ns DC gain accuracy 2 % Input sensitivity: 13 calibrated steps CH 1, CH 2 [CH 1 CH 4] 1 mv/div. 10 V/div. (1 2 5 Sequence) Variable Between calibrated steps Inputs CH 1, CH 2 [CH 1 CH 4]: Impedance 1 MΩ II 14 pf ±2 pf DC, AC, GND Max. input voltage 200 V (DC + peak AC) Measuring circuits: Measuring Category I (CAT I) Position range: ±10 Divs Logic Channels: With Option HO3508 Select. switching thresholds TTL, CMOS, ECL, User -2 +8 V Impedance 100 kω <4 pf DC Max. input voltage: 40 V (DC + peak AC) Triggering Analog Channels: Automatic: Linking of peak detection and trigger level Min. signal height 0.8 div.; 0.5 div. typ. (1.5 div. at 2 mv/div.) Frequency range 5 Hz 150 MHz (5 Hz 30 MHz at 2 mv/div.) Level control range From peak- to peak+ Normal (without peak): Min. signal height 0.8 div.; 0.5 div. typ. (1.5 div. at 2 mv/div.) Frequency range 0 Hz 150 MHz (0 Hz 30 MHz at 2 mv/div.) Level control range -10 +10 div. Operating modes: Slope/Video/Logic/Pulses/Buses optional Slope: Rising, falling, both s CH 1, CH 2, Line, Ext., LCH 0 7 [CH 1 CH 4, Line, Ext., LCH 0 7] (Analog Channel) AC: 5 Hz 150 MHz DC: 0 150 MHz HF: 30 khz 150 MHz LF: 0 5 khz Noise rejection: selectable Video: Standards PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p Fields Field 1, field 2, both Line All, selectable line number Sync. Impulse Positive, negative s CH 1, CH 2, Ext. [CH 1 CH 4] Logic: AND, OR, TRUE, FALSE s LCH 0 7, CH 1, CH 2 [CH 1...CH 4] State LCH 0 7 X, H, L Duration 8 ns 2.147 s, resolution 8 ns Pulses: Positive, negative Modes equal, unequal, less than, greater than, within/without a range Range Min. 32 ns, max. 17.179 s, resolution min. 1 ns s CH 1, CH 2, Ext. [CH 1 CH 4] Indicator for trigger action: LED Ext. Trigger via: Auxiliary input 0.3 V 10 V pp 2 nd Trigger: Slope Rising, falling, both Min. signal height 0.8 div.; 0.5 div. typ. (1.5 div. at 2 mv/div.) Frequency range 0 Hz 150 MHz (0 Hz 30 MHz at 2 mv/div.) Level control range -10 +10 div. Operating modes after time 32 ns 17.179 s, resolution 8 ns after incidence 1 2 16 Serial Buses: Option HOO10 I 2 C/SPI/UART/RS-232 on Logic Channels and Analog Channels Option HOO11 I 2 C/SPI/UART/RS-232 on Analog Channels Option HOO12 CAN/LIN on Logic Channels and Analog Channels Horizontal System Domain representation: Time, Frequency (FFT), Voltage (XY) Representation Time Base: Main-window, main- and zoom-window Memory Zoom: Up to 50,000:1 Accuracy: 50 ppm Time Base: 2 ns/div. 50 s/div. Roll Mode 50 ms/div. 50 s/div. Digital Storage Sampling rate (real time): Memory: Operation modes: Resolution (vertical): Resolution (horizontal): Interpolation: Persistence: Delay pretrigger: posttrigger Display refresh rate: Display: Reference memories: 2 x 1 GSa/s, 1 x 2 GSa/s [4 x 1 GSa/s, 2 x 2 GSa/s] Logic Channels: 8 x 1 GSa/s 2 x 1 MPts, 1 x 2 MPts [4 x 1 MPts, 2 x 2 MPts] Refresh, Average, Envelope, Peak-Detect Roll: free run/triggered, Filter, HiRes 8 Bit, (HiRes up to 10 Bit) 40 ps Sinx/x, linear, Sample-hold Off, 50 ms 0 8 Million x (1/samplerate) 0 2 Million x (1/samplerate) Up to 2,000 waveforms/s Dots, vectors, persistence typ. 10 Traces Operation/Measuring/Interfaces Operation: Menu-driven (multilingual), Autoset, help functions (multilingual) Save/Recall memories: typ. 10 complete instrument parameter settings Frequency counter: 0.5 Hz 150 MHz 6 Digit resolution Accuracy 50 ppm Auto measurements: Amplitude, standard deviation, V pp, V p+, V p-, V rms, V avg, V top, V base, frequency, period, pulse count, t width+, t width-, t dutycycle+, t dutycycle-, t Rise10_90, t Fall10_90, t Rise20_80, t Fall20_80, pos. edge count, neg. edge count, pos. pulse count, neg. pulse count, trigger frequency, trigger period, phase, delay Measurement statistic: Min., max., mean, standard deviation, number of measurements for up to 6 Functions Cursor measurements: V, t, 1/ t (f), V to Gnd, Vt related to Trigger point, ratio X and Y, pulse count, peak to peak, peak+, peak-, mean value, RMS value, standard deviation Search functions: Search- and Navigation functions for specfic signal parameter Interface: Dual-Interface USB type B/RS-232 (HO720), 2 x USB type A (front- and rear side each 1 x) max. 100 ma, DVI-D for ext. Monitor Optional: IEEE-488 (GPIB) (HO740), Dual-Interface Ethernet/USB (HO730)

Display functions Marker: VirtualScreen: Busdisplay: Mathematic functions Number of formula sets: s: Targets: Functions: Display: Pass/Fail functions s: Type of test: Functions: up to 8 user definable marker for easy navigation; automatic marker using search criteria virtual Display with 20 div. vertical for all Math-, Logic-, Bus- and Reference Signals up to 2 busses, user definable, parallel or serial busses (option), decode of the bus value in ASCII, binary, decimal or hexadecimal, up to 4 lines; Table view of the decoded data 5 formula sets with up to 5 formulas each All Channels and math. memories Math. memories ADD, SUB, 1/ X, ABS, MUL, DIV, SQ, POS, NEG, INV, INTG, DIFF, SQR, MIN, MAX, LOG, LN, Low-, High-pass filter Up to 4 math. memories with label Analog Channels Mask around a signal, userdefined tolerance Stop, Beep, screen shot (screen print-out) and/or output to printer for pass or fail, event counting up to 4 billion, including the number and the percentage of pass and fail events General Information Component tester Test voltage: 10 V P (open) typ. Test current: 10 ma P (short) typ. Test frequency: 50 Hz / 200 Hz typ. Reference Potential: Ground (safety earth) Probe ADJ Output: 1 khz/1 MHz square wave signal ~1 V pp (ta <4 ns) Bus Signal : SPI, I 2 C, UART, Parallel (4 Bit) Internal RTC (Realtime clock): Date and time for stored data Line voltage: 100 240 V, 50 60 Hz, CAT II Power consumption: Max. 45 W, typ. 25 W [max. 55 W, typ. 35 W] Protective system: Safety class I (EN61010-1) Operating temperature: +5 +40 C Storage temperature: -20 +70 C Rel. humidity: 5 80 % (non condensing) Theft protection: Kensington Lock Dimensions (W x H x D): 285 x 175 x 140 mm Weight: <2.5 kg Accessories supplied: Line cord, Operating manual, 2 [4] Probes, 10:1/1:1 switchable (HZ154), CD, Software Recommended accessories: HOO10 Serial bus trigger and hardware accelerated decode, I 2 C, SPI, UART/RS-232 on Logic Channels and Analog Channels HOO11 Serial bus trigger and hardware accelerated decode, I 2 C, SPI, UART/RS-232 on Analog Channels HOO12 Serial bus trigger and hardware accelerated decode, CAN, LIN on Logic Channels and Analog Channels HO3508 Active 8 Channel Logic Probe HO730 Dual-Interface Ethernet/USB HO740 Interface IEEE-488 (GPIB) galvanically isolated HZO91 4RU 19" Rackmount Kit HZO90 Carrying Case for protection and transport HZO20 High voltage probe 1,000:1 (400 MHz, 1,000 V rms ) HZO30 Active probe 1 GHz (0.9 pf, 1 MΩ, including many accessories) HZO40 Active differential Probe 200 MHz (10:1, 3.5 pf, 1 MΩ) HZO41 Active differential Probe 800 MHz (10:1, 1 pf, 200 kω) HZO50 AC/DC Current probe 30 A, DC 100 khz HZO51 AC/DC Current probe 100/1,000 A, DC 20 khz HMO1022/HMO1024E/191212 C&E Subject to change without notice HAMEG Instruments GmbH DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08 HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49 (0) 6182 8000 Fax +49 (0) 6182 800100 www.hameg.com info@hameg.com

HOO10/HOO11 Serial Bus for all Oscilloscopes of the HMO Series HOO10/HOO11 Mixed Signal and Bus Display SPI Bus Trigger Setup I 2 C Bus Hex decoding on the Analog Channel I 2 C Bus ASCII and Binary R HOO10 via Analog Channels and/or Logic Channels, HOO11 via Analog Channels R I 2 C, SPI, UART/RS-232 Bus Trigger and Decode R Hardware accelerated Decode in Real Time R Color Coded Display of the Content for intuitive Analysis and easy Overview R More Details of the decoded Values become visible with increasing Zoom Factor R Bus Display with synchronous Display of the Data and, if selected, Clock Signal R Decode into ASCII, Binary, Hexadecimal or Decimal Format R Up to four Lines to comfortably show the decoded Values R Powerful Trigger to isolate specific Messages R Option for all Oscilloscopes of the HMO Series, retrofittable

HOO10/HOO11 I²C, SPI, UART/RS-232 Bus Analysis I 2 C Bus SPI Bus UART/RS-232 Bus Bus Configuration Bit/Baud rate up to 10 Mbit/s (HMO352x/2524), up to 5 Mbit/s (HMO72x 202x) up to 25 Mbit/s (HMO352x/2524), up to 12.5 Mbit/s (HMO72x 202x) 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 Baud, up to 62.5 Mbit/s (HMO352x/2524), up to 31 Mbit/s (HMO72x 202x) Number of Bit s 7 or 10 Bit for Address ID 8 Bit for Data 32 Bit for Data 8 Bit for Data 1, 1.5, 2 Bit for Stop Bit Polarity n/a Chip Select, positive or negative, or without Chip Select (2-wire SPI) Clock rising or falling edge Data High or Low active High or Low active Parity n/a n/a none, odd or even Trigger Event 7 or 10 Bit Address ID 7 or 10 Bit Address ID with 8 Bit Data Start, Stop, Restart missing Acknowledge Address ID without Acknowledge Data packets up to 32 Bit with positive or negative Chip Select or without Chip Select, (2-wire SPI) Data packets up to 8 Bit Input format Hexadecimal or Binary Hexadecimal or Binary Hexadecimal or Binary Hardware accelerated Decode Display Bus display, color coded for Bus display, color coded for Bus display, color coded for Read Address ID: Write Address ID: Start: Stop: ACK/NACK: Trigger Condition: Yellow Magenta Green/ Green Start: Stop: Trigger Condition: Green Start: Stop: Trigger Condition: Green Format Address ID: hexadecimal ASCII, binary, decimal, hexadecimal n/a ASCII, binary, decimal, hexadecimal n/a ASCII, binary, decimal, hexadecimal Differences HOO10/HOO11 Feature HOO10 HOO11 Logic Channels (LCH 0 LCH 15) as source for serial bus trigger and decode x - Analog Channels (CH 1 CH 4) as source for serial bus trigger and decode x x Time synchronous decode of two serial busses x - HOO10/HOO11E/191212 C&E Subject to change without notice HAMEG Instruments GmbH DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08 HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49 (0) 6182 8000 Fax +49 (0) 6182 800100 www.hameg.com info@hameg.com

HOO12 CAN/LIN Bus Analysis for all Oscilloscopes of the HMO Series HOO12 Mixed Signal and Bus Display CAN Bus Configuration CAN Bus list display CAN Bus HEX R CAN, LIN Bus Trigger and Decode R Hardware accelerated Decode in Real Time R Color Coded Display of the Content for intuitive Analysis and easy Overview R More Details of the decoded Values come visible with increasing Zoom Factor R Bus and List Display with synchronous Display of the Data R Decode into ASCII, Binary, Hexadecimal or Decimal Format R Up to four Lines to show the decoded Values R Powerful Trigger to isolate specific Messages R Option for all Oscilloscopes of the HMO Series, retrofittable

HOO12 CAN/LIN Bus Analysis Bus Configuration Bit rates Signal Type CAN Bus Pre-Defined or User-Select, 100 Bit/s 4 Mb/s (HMO352x /2524), 100 Bit/s 2 Mb/s (HMO72x 202x) CAN-L or CAN-H, Single Ended or Differential Probe (Analog Channels only) LIN Bus Pre-Defined or User-Select, 100 Bit/s 4 Mb/s (HMO352x /2524), 100 Bit/s 2 Mb/s (HMO72x 202x) n/a Sample Point Range 25 90 % n/a Threshold Pre-Defined or User-Select Pre-Defined or User-Select Polarity n/a High or Low Active Protocol Version n/a 1.x, 2.x, J2602, 1.x or 2.x Trigger Event Start of Frame (SOF), End of Frame (EOF) Error Frame Error condition: Stuff Bit Error, CRC Error, Not Acknowledge, Form Error Overload Frame Data Frame (11 or 29 Bit ID) Remote Frame (11 or 29 Bit ID) Identifier: 0, 1, X (Don t Care) Pattern, Trigger when =,, <, > Identifier and ID and 64 Bit data pattern (0, 1, X), trigger when =,, <, > Start of Frame (SOF), Wake Up Frame Error Frame Error condition: Checksum Error, Parity Error Synchronisation Error Identifier: 0, 1, X (Don t Care) Pattern, Trigger when =,, <, > Identifier and ID and 64 Bit data pattern (0, 1, X), trigger when =,, <, > Input format Hexadecimal or Binary Hexadecimal or Binary Hardware accelerated Decode Display Bus color coded for Start and End of Frame: brackets Data ID: Magenta, Remote ID: Yellow DLC:,, CRC: ACK: Green, Overload:, color coded for Start and End of Frame: brackets Break: Magenta, Synchronisation: Identifier: Yellow, Parity: Green, Checksum:,, Wake Up: Magenta Table Display of Bus 0 or 1 Frame Number State (Frame Type or Error Description) Start Time, Identifier, DLC, CRC, Data Display of Bus 0 or 1 Frame Number State (Frame Type or Error Description) Start Time, Identifier, Length, Checksum, Data Format Identifier & other: hexadecimal ASCII, binary, decimal, hexadecimal Identifier & other: hexadecimal Data & Checksum: ASCII, binary, decimal, hexadecimal HOO12E/191212 C&E Subject to change without notice HAMEG Instruments GmbH DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08 HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49 (0) 6182 8000 Fax +49 (0) 6182 800100 www.hameg.com info@hameg.com