Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Similar documents
Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement RF Capacitance switches

Level Measurement Continuous level measurement - Capacitance transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

Level Measurement Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

Level Measurement Continuous level measurement Radar transmitters

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Level Measurement Continuous level measurement - Radar transmitters

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Mechanical flow switch for On/Off control

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

TFRN Industrial RTD temperature sensor. CombiTemp TM

Level Measurement Continuous level measurement - Radar transmitters

2291 Guided Wave Radar Level Transmitter

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Flow Measurement SITRANS F M

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Flow Measurement SITRANS F M

Pressure transmitter For applications in hazardous areas Model IS-3

SITRANS F M. Transmitter MAG 5000/6000 4/33

TFRN Industrial RTD temperature sensor. CombiTemp TM

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

TFRH Hygienic RTD temperature sensor. CombiTemp TM

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Single Point Flow Monitor SW118 SW119

Bimetal Temperature Switch

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Capacitance Level Measurement Electronic insert FEC 12

Modular Lube Lubrication Systems System Controls

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Horn loudspeaker, Ex proof, short/long flare

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Rosemount 1151 Smart Pressure Transmitter

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

EXPlora. Introduction

Viper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Eddy Current Probe System

DMP 331i / DMP 333i LMP 331 i

Signet 2250 Hydrostatic Level Sensor

RMA42. Technical Information

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

APPLICATIONS. Automatic warehouse. Trasportation lines

Inductive sensor NI10-M18-Y1X-H1141

Level Measurement silometer FMC 420, FMC 423

Inductive sensor NI3-EG08K-Y1-H1341

Process transmitter RMA422

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Pendant Light Fitting IEC Series 6470/2

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

APPLICATIONS. Automatic warehouse. Trasportation lines

RSCC. Load cells. Special features. Data sheet

Liquid Level Sensor Type AKS 4100U

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

Quality products from a single source

EXLUX ECOLUX C-LUX 6480 Series

TFR5 Room or outdoor temperature sensor. CombiTemp TM

3 Cleaning. 4 Technical data

Linear flow controls VFC Linear flow controls with actuator IFC

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Inductive sensor BI1.5-EG08K-Y1

Sensor technologies Proximity sensors Series ST4. Brochure

Cylindrical Photoelectric Sensor CY-100 SERIES

CombiSeries. Making temperature, pressure and conductivity measurement safe and convenient.

ABB IEC International Pin and Sleeve

>Inductive and CATALOG. Capacitive Sensors

>Inductive and. REFERENCE guide. Capacitive Sensors


Liquid Level Sensor AKS 4100U

High Performance TOR-SPRING EMI/RFI Cord Grips

ATEX-manual for units

Liquid Level Sensor Type AKS 4100/4100U

Guided Radar (TDR) Level Transmitter for storage and process applications

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

EXLUX ECOLUX 6480 Series

Technical Information RIA45

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Type AKS 4100/4100U Coaxial D14 version

Transcription:

Siemens G 2009 Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits Easy installation with verification by built-in LED Low maintenance with no moving parts Sensitivity adjustment Integrated cable or PBT enclosure versions available Intrinsically Safe, Dust Ignition Proof and General Purpose options available pplication s short insertion length of 100 mm (4") and versatility in various applications and in vessels or pipes makes it a good replacement for traditional capacitance sensors. Its advanced tip-sensing technology provides accurate, repeatable switchpoint performance. The PPS (Polyphenylene sulfide) probe [optional PVDF (Polyvinylidene Fluoride)] is chemically resistant with an effective process operating temperature range from -30 to +100 C (-22 to +212 F) (7ML01), and -10 to +100 C (+14 to +212 F) (7ML610). The fully potted design ensures reliability in a vibrating environment such as agitated tanks up to 4 g. When used with a SensGuard protection cover, the CLS100 is protected from shearing, impact and abrasion in tough primary processes. The is available in three versions. The integral cable version has a stainless steel process and probe options of PPS or PVDF. The fully synthetic version has a thermoplastic polyester enclosure with a PPS process combined with a PPS probe. The standard enclosure version has a thermoplastic polyester enclosure with a stainless steel process in combination with a PPS or PVDF probe. Key pplications: liquids, slurries, powders, granules, food and pharmaceuticals, chemicals, hazardous areas installation /10 Siemens FI 01 2010

Siemens G 2009 Level instruments Technical specifications Mode of operation Measuring principle Input Measured variable Output Output signal larm output Switch output 1) Stainless steel process (integral cable or enclosure (7ML01) Inverse frequency shift capacitive level detection Change in picofarad (pf) 4 or 20/20 or 4 m 2-wire loop Solid-state: 30 V DC/ 30 V C, max. 82 m Fully synthetic process (enclosure version only) (7ML610) Inverse frequency shift capacitive level detection Change in picofarad (pf) 4 or 20/20 or 4 m 2-wire loop Max. switching voltage: 60 V DC/30 V C Max. switching current: 1 Fail-safe mode Min. or max. Min. or max. ccuracy Repeatability 2 mm (0.08") 2 mm (0.08") Rated operating conditions 2) Installation conditions Location Indoor/outdoor Indoor/outdoor mbient conditions mbient temperature Installation category -30 to +8 C (-22 to +18 F) I -10 to +8 C (+14 to +18 F) I Pollution degree 4 4 Medium conditions Relative dielectric contant ε r Min. 1. Min. 1. Process temperature Pressure (vessel) Degree of protection - Enclosure version - Integral cable version Cable inlet Design Material - Body (Enclosure - Lid (Enclosure - Integrated cable body (Integral cable -30 to +100 C (-22 to +212 F) -1 to +10 bar g (-14.6 to +146 psi g), nominal 2) -10 to +100 C (+14 to +212 F) -1 to +10 bar g (-14.6 to +146 psi g), nominal IP68/Type 4/NEM 4 IP68/Type 4/NEM 4 IP6/Type 4/NEM 4 ½" NPT (M20x1. optional) Enclosure/ Integral cable version Thermoplastic polyester Transparent thermoplastic polycarbonate (PC) 316L stainless steel ½" NPT (M20x1. optional) Fully synthetic version Thermoplastic polyester Transparent thermoplastic polycarbonate (PC) Sensor length (nominal) Process material of probe/wetted parts Connection (Enclosure 100 mm (4") 100 mm (4") Connection: 316L stainless steel; Process seal: FKM (optional FFKM); Sensor: PPS (optional PVDF) 3) Internal -point terminal block, ½" NPT wiring entrance, M20x1. optional Connection 4 conductors, (Integral cable WG), shielded, poly- 1 m (3.3 ft), 0. mm² (22 ester jacket Process Power supply ¾" NPT [(Taper), NSI/SME B1.20.1] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] PPS process and PPS sensor (Uni-Construction) Removable internal -point terminal block, ½" NPT wiring entrance, M20 x 1. optional ¾" NPT [(Taper), NSI/SME B1.20.1] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] Standard Intrinsically Safe 10 to 30 V DC (Intrinsically Safe barrier required) Certificates and approvals Stainless steel process (integral cable or enclosure (7ML01) General: CE, CS, FM, C-TICK Marine: Lloyds Register of Shipping, categories ENV1, ENV2, and ENV Dust Ignition Proof (barrier required): CS/FM Class II and III, Div. 1, Groups E, F, G T4 Intrinsically Safe (barrier required): CS/FM Class I, II and III, Div. 1, Groups, B, C, D, E, F, G T4 TEX II 1 GD 1/2GD EEx ia IIC T4 to T6 T107 C Overfill protection: WHG (Germany) Fully synthetic process (enclosure version only) (7ML610) General: CE, CS, FM, C-TICK Marine: Lloyds Register of Shipping, categories ENV1, ENV2, and ENV Dust Ignition Proof: TEX II 1D 1/ 3D T107 C Overfill protection: WHG (Germany) 1) When synthetic process version (7ML610) is used in wet locations, switching voltage of the relay is limited to 3 V DC/16 V C. 2) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /13. 3) When FFKM O-ring (Option 22) is selected, process temperature is restricted to -20 C (-4 F). Siemens FI 01 2010 /11

Siemens G 2009 Z Selection and Ordering data, stainless steel process C) 7 M L 0 1 - Compact 2-wire inverse frequency shift capacitance 0 7 7 77 switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam Process ¾" NPT [(Taper), NSI/SME B1.20.1] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), J JIS B 0202] pprovals General Purpose: CE, CS, FM, C-TICK CS/FM Class I, II and III, Div. 1, Groups, B, C, C D, E, F, G T4; TEX II 1 GD 1/2GD EEx ia IIC T4 to T6 T107 C 1) CS/FM Class II and III, Div. 1, Groups E, F, G 1) G Device version Integral cable version (PPS probe) 1 Enclosure version (PPS probe), ½" NPT cable inlet 3 Integral cable version with PVDF probe body Enclosure version with PVDF probe body 6 (½" NPT cable inlet) Enclosure version (PPS probe), 7 M20x1. cable inlet Enclosure version with PVDF probe body, 8 M20x1. cable inlet WHG approval, German overfill protection Not required 0 Required 1 Further designs Order code Please add "-Z" to and specify Order code(s). crylic coated, stainless steel tag [13 x 4 mm Y17 (0. x 1.7")]: Measuring-point number/identification (max. 20 characters) specify in plain text FFKM seal O-ring 2) 22 Inspection Certificate Type 3.1 per EN 10204 C12 Instruction manual Quick start manual, multi-language Note: due to TEX regulations one Quick start manual is included with every product. This device is shipped with the Siemens Milltronics manual CD containing TEX Quick Starts and instruction manuals. Optional equipment Sensguard, ¾" NPT (PPS) Sensguard, R 1" (BSPT) (PPS) Siemens Intrinsically Safe Barrier (DC powered), TEX II 1 G EEx ia ½" NPT cable gland, nickel plated brass, fits cable diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 C (-40 to +212 F), IP68 (General Purpose) M20x1. cable gland, P polyamide, TEX II 2G EEx e II, fits cable diameter 7 to 12 mm (0.28 to 0.47"), -20 to +70 C (-4 to +18 F), IP68 (General Purpose) 1) Barrier or Intrinsically safe power supply required for Intrinsically Safe protection 2) See Temperature restriction on page /13 C) Subject to export regulations L: N, ECCN: ER99 7ML1998-QJ81 7ML1830-1DL 7ML1830-1DM 7NG4122-110 7ML1830-1J 7ML1830-1JC Selection and Ordering data, PPS process C) 7 M L 6 1 0 - Compact 2-wire inverse frequency shift capacitance switch for level detection in constricted 0 7777 spaces, interfaces, solids, liquids, slurries and foam Process (PPS) ¾" NPT [(Taper), NSI/SME B1.20.1] (PPS probe body) R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] B (PPS probe body) pprovals General Purpose: CE, CS, FM, C-TICK TEX II 1D 1/3D T107 C C Versions/Options Enclosure version, PPS process, 1 ½" NPT cable inlet Enclosure version, PPS process, 2 M20x1. WHG approval, German overfill protection Not required 0 Required 1 Further designs Order code Please add "-Z" to and specify Order code(s). crylic coated, stainless steel tag [13 x 4 mm Y17 (0. x 1.7")]: Measuring-point number/identification (max. 20 characters) specify in plain text Instruction manual Quick start manual, multi-language 7ML1998-QJ81 Note: due to TEX regulations one Quick start manual is included with every product This device is shipped with the Siemens Milltronics manual CD containing TEX Quick Starts and instruction manuals. ccessories Sensguard, ¾" NPT (PPS) 7ML1830-1DL Sensguard, R 1" (BSPT) (PPS) 7ML1830-1DM Options Optional Sensguard dimensions /12 Siemens FI 01 2010

Siemens G 2009 Level instruments Characteristic curves P Example: Permitted operating pressure = 10 bar (14 psi) at 7 C -30 ºC (-22 ºF) T Pressure/Temperature Curve CLS100 (7ML01) Threaded Process Connections P = Permitted Operating Pressures T = Permitted Operating Temperature Process Pressure/Temperature derating curves Dimensional drawings dimensions Siemens FI 01 2010 /13

Schematics Integral Cable Version - Non Intrinsically Safe only Siemens G 2009 LOW/HIGH larm polarity as required for desired operation 4 to 20 m Loop larm Solid State Switch Version Rmax = Vsupply - 10 V 20 m V supply solid state switch, 30 V DC/C (peak) 82 m (max) Enclosure and Fully Synthetic Version 1 2 3 4 terminal operations m current loop (+V or -V) m current loop (+V or -V) ground solid state switch / relay* solid state switch / relay* black red cable equivalent red wire black wire cable shield wire wire V supply * switch/relay normally open in unpowered state * relay not available on IS version (7ML01) Note: When driving an inductive load (for example, an external relay), a protection diode must be connected in the correct polarity to prevent possible switch damage due to inductive spikes generated by switching the inductor (please refer to instruction manual). Intrinsically Safe Models - please follow local regulations and area classifications; refer to instruction manual for more details. s /14 Siemens FI 01 2010