Features low conversion loss, 6.05 db typ. good L-R isolation, 35 db typ, L-I, 30 db typ. wideband, 10 to 2000 MHz rugged shielded case

fco, MHz Nom. * Not for use with DC voltage at input and output ports 3dB 1dB F co F 20 F R E QUE NC Y F R 20dB Frequency (MHz)

Features wideband, 10 to 500 MHz. Applications military, hi-rel applications stabilizing generator outputs reducing amplitude variations

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

Keysight Technologies ad Integrated RF Test Solution

Limiter RLM Ω Broadband 950 to 2050 MHz. The Big Deal

No need for external driver, saving PCB space and cost.

Features excellent conversion loss, 6.0 db typ. high L-R isolation, 40 db typ. L-I isolation, 55 db typ. rugged welded construction

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

SP6T RF Switch JSW6-23DR Ω High Power 3W 5 to 2000 MHz. The Big Deal

Features low conversion loss, 6.11 db typ. excellent L-R isolation, 44 db typ. CONVERSION LOSS (db) Mid-Band m. Range f L. Conversion Loss (db)

Omega 4K/UHD Three-Input Switcher. Introduction. Applications. for HDMI and USB-C with HDBaseT and HDMI Outputs

ADE-R3GLH+ CONVERSION LOSS 50. ISOLATION (db) 10 LO= +7 dbm LO= +10 dbm LO=+13 dbm FREQUENCY (MHz) RF VSWR

Features low conversion loss, 5.94 db typ. aqueous washable J-leads for strain relief. CONVERSION LOSS (db) Mid-Band m. Range f L.

Features low conversion loss, 6.79 db typ. wideband, 1 to 1000 MHz. Applications HF/VHF/UHF cellular federal & defense communications

JD725A Cable and Antenna Analyzer - Dual Port

SMS3000X Series Spectrum Analyzer

LAVI-U252VH+ Performance Charts. LO=+18dBm LO=+21dBm LO=+24dBm. LO=+18dBm LO=+21dBm LO=+24dBm. LO=+18dBm LO=+21dBm LO=+24dBm

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

ThinkRF D GHz RF Downconverter

USB-TG124A Tracking Generator User Manual

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

GFT channel Time Interval Meter

Frequency Mixer wide band

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Extension kit for R&S Vector Network Analysers

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Full-featured CW Microwave Counters for Field, Factory or Lab

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

R-1580A Microwave Downconverter. Product Brochure

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Modular Block Converter Systems

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Ethernet to VGA over IP Converter

Advanced Test Equipment Rentals ATEC (2832)

DA E: Series of Narrowband or Wideband Distribution Amplifiers

R&S ZN-Z154 Calibration Unit Specifications

R&S ZVA110 Vector Network Analyzer Specifications

Monolithic Amplifier GVA-60+ Flat Gain, High IP to 5 GHz. The Big Deal

RF Semiconductor Test AXRF RF Port Upgrade Kits

R&S ZN-Z85 Switch Matrix Specifications

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

PicoScope 4000 Automotive PC Oscilloscopes

Synthesized Block Up- and Downconverter Indoor / Outdoor

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

HVWIP-Series (HVWIP-T + HVWIP-R)

GaAs MMIC Double Balanced Mixer

DSM GHz Linear Chirping Source

WaveNow USB Potentiostat / Galvanostat

DS2460Q QAM Analysis Meter

SSA3000X Series Spectrum Analyzer

VM3404H/VM3909H. 4 x 4 / 9 x 9 HDMI HDBaseT-Lite Matrix Switch EDID. VanCryst Professional A/V Solutions

GFT Channel Digital Delay Generator

R3267/3273 Spectrum Analyzers

RF2360 LINEAR GENERAL PURPOSE AMPLIFIER

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

PicoScope 3000 Series Automotive User guide

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

GaAs MMIC Double Balanced Mixer

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

PicoScope 2000 Series PC Oscilloscopes

FLAT DISPLAY TECHNOLOGY

Instruction Manual Model Block Up/Downconverter

PicoScope 6407 Digitizer

Driver circuit for MPPC

SSA3000X Series Spectrum Analyzer

DATENBLATT. SSA3000X-Serie. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.

Agilent 87075C Multiport Test Set Product Overview

RF1119ATR7. SP4T (Single Pole Four Throw Switch) Product Overview. Key Features. Functional Block Diagram. Applications. Ordering Information

Satellite Up- and Downconverter Indoor / Outdoor

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio

E4416A EPM-P Series Single Channel Power Meter

NI PXI/PXIe-2543 Specifications

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S HF907DC SHF Downconverter Specifications

Inmarsat Downconverter Narrowband Downconverter

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

ThinkRF R5500. Real-Time Spectrum Analyzer. 9 khz to 8 GHz / 18 GHz / 27 GHz. Product Brochure and Technical Datasheet. Featuring

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

R&S DST200 RF Diagnostic Chamber Specifications

AT450SAW Programmable Selective Amplifier

QPC6222SR GENERAL PURPOSE DPDT TRANSFER SWITCH. Product Overview. Key Features. Functional Block Diagram. Applications. Ordering Information

Product Introduction. Duplexer Box MN2555A. Signal Analyzer MS2830A. Ver.1.0

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

Advantech Proudly Presents Professional Monitor Series

Transcription:

USB / Ethernet Integrated Frequency Counter & Power Meter 50Ω -30 dbm to +20 dbm, 1 MHz to 6000 MHz The Big Deal Automatically synchronized power & frequency measurements USB and Ethernet control Includes GUI with measurement applications software, simplifying complex measurements Measurement speed 30ms CASE STYLE: JL2029 Installation CD Product Overview Mini-Circuits Integrated Frequency Counter & Power Meter is a pocket-sized (5.00 x 2.66 x 1.36 ) precision test device controlled via USB or Ethernet (HTTP and Telnet protocols) or operated as standalone test instrument. It simplifies test setups by enabling synchronized frequency and power measurements from a single device. The unit features an LCD display allowing convenient readings directly off the measurement head, while our user-friendly GUI software enables easy remote test management via USB or Ethernet. It comes supplied with Mini-Circuits GUI software, DLLs for programmers, user guide, programming instructions, and all the accessories needed for immediate use right out of the box (see page 8 for a complete list of included accessories). Key Features Feature Ethernet-TCP/IP- HTTP and Telnet Protocols (Supports DHCP and Static IP) USB control GUI program with USB and Ethernet interfaces Measurement Application GUI software built-in LCD character display Operates with external or internal reference No calibration required before taking measurement 5V power supply Advantages The integrated freq. counter & power meter can be controlled from any Windows, or Linux computer, or even a mobile device with a network connection and Ethernet-TCP/IP (HTTP or Telnet protocols) support. Using a VPN would allow remote control from anywhere in the world. User may also control the integrated freq. counter & power meter via USB connection. Plug-and- Play, no driver required. Compatible with Windows or Linux operating systems using 32 and 64 bit architecture (up to 24 sensors simultaneously). Allows quick and easy measurement, average measurements, data recording, and more. Automated measurement setups which allow the user to perform measurements on RF components such as Couplers, Filters, Amplifiers, etc., display numerical data and graphs, and analyze the data. LCD character display providing the frequency and power readings, as well as information on the unit s status. The can operate either synchronized with an external 10 MHz reference signal or independently, using its internal reference depending on user preference. The does not require any reference signal for calibration, reducing test time and simplifying operation. Powered via USB plug from PC, supplied AC adapter or from commercially available Power Over Ethernet (PoE) splitter with 5V output. Trademarks: Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Mac is a registered trademark of Apple Corporation. Pentium is a registered trademark of Intel Corporation. Neither Mini-Circuits nor the Mini-Circuits FCPM- 6000RC are affiliated with or endorsed by the owners of the above referenced trademarks Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation. Page 1 of 8

USB / Ethernet Integrated Frequency Counter & Power Meter 50Ω 1 MHz to 6000 MHz Product Features USB and Ethernet control Supports HTTP and Telnet network protocols Wide bandwidth, 1 to 6000 MHz Uses external or internal reference LCD character display 50 db Dynamic Range, -30 to +20 dbm Good VSWR, 1.1:1 typ. Fast measurement speed, 30 ms (power), 100 ms (freq). Automatic frequency calibration & temperature compensation Multi-sensor capability (up to 24) Built in Application Measurement software User-friendly Windows Graphical User Interface Supports a wide range of programming environments (See application note AN-49-001 for details) Typical Applications Production testing systems Field testing Remote location monitoring Automatic, scheduled data collection Evaluate high-power, multi-port devices with built-in virtual couplers/attenuators & other software tools CASE STYLE: JL2029 Model No. Description Price Qty. Integrated Freq. Counter $1495.00 ea. & Power Meter (1-4) Included Accessories USB-AC/DC-5 AC/DC 5V Adapter 1 USB-RJ45-CBL-7+ 6.6 ft Y data cable (USB & RJ45) 1 FCPM-CD Installation CD 1 RoHS Compliant See our web site for RoHS Compliance methodologies and qualifications Installation CD Mini-Circuits Program for Integrated Frequency Counter & Power Meters For programming instructions, see programming manual on Mini-Circuits website. For installation instruction and overview of functions, see user guide on Mini-Circuits website. Rev. OR M150845 EDR-11250 RAV 150426 Page 2 of 8

Electrical Specifications (CW) 1, -30 dbm to +20 dbm, 1 to 6000 MHz Parameter Dynamic range 2,3 @ 25ºC Freq. Range (MHz) Min. Typ. Max. Units 1-5700 -30 +20 5700-6000 -28 +20 @ 0ºC to 50ºC 1-6000 -27 +20 VSWR 1-6000 1.05 1.25 :1 Uncertainty of Power Measurement @ 25ºC Uncertainty of Power Measurement @ 0ºC to 50ºC @ -30 to +5 dbm 4,5 1-3000 ± 0.10 ± 0.30 db 3000-6000 ± 0.15 ± 0.30 db @ +5 to +15 dbm @ +15 to +20 dbm 1-3000 ± 0.15 ± 0.30 db 3000-6000 ± 0.15 ± 0.30 db 1-3000 ± 0.20 ± 0.40 db 3000-6000 ± 0.20 ± 0.40 db @ -30 to +5 dbm 4,5 1-3000 ± 0.25 db 3000-6000 ± 0.25 db @ +5 to +15 dbm @ +15 to +20 dbm 1-3000 ± 0.20 db 3000-6000 ± 0.20 db 1-3000 ± 0.35 db 3000-6000 ± 0.30 db Power Linearity @ 25ºC 1-6000 ± 3.0 % Power Resolution 1-6000 0.01 db Frequency Resolution 40-190 MHz 10 1-40 MHz 1 Frequency Uncertainty (@1 sec measurement sample time) 6 190-6000 MHz 100 1-40 MHz ±2 40-190 MHz ±20 190-1400 MHz ±200 1400-6000 MHz ±800 Averaging Range 1-6000 1-999 Frequency Aging Using int. Reference ±1.0 ppm/year Measurement Speed (for power meas.) @ Low Noise Mode 100 1-6000 @ Faster Mode 30 Sample time (for frequency meas.) 7 100 1000 3000 msec Input Impedance 50 Ω Reference In Frequency 10 MHz Reference In Impedance 50 Ω Reference In Power -5 +10 dbm Supply Voltage via USB port 1-6000 4.5 5 5.5 V Current (via USB port, in USB control) 1-6000 370 500 ma Current (via USB port, in Ethernet control) 1-6000 380 500 ma Ethernet communication Supports both Telnet and HTTP protocols over TCP/IP with dynamic(dhcp) or static IP 1 All specifications apply to continuous wave (CW) signals. 2 Maximum continuous safe operational power limit: +23 dbm. Performance is guaranteed up to +20 dbm. 3 The can operate down to -32 dbm, however performance is guaranteed only in the range specified in the table. 4 When using Faster mode at high frequencies below -20dBm, use of averaging is recommended to prevent noise errors. 5 When using Faster mode power reading below -20dBm, uncertainty value may increase by up to 0.2 db relative to Low noise mode power reading. 6 Accuracy shown using external 10 MHz reference synchronized to test signal. Using Internal Reference adds 2 ppm of tested frequency to the accuracy values shown. 7 Software function set by user, default option 1000 mec. dbm Hz Hz msec Page 3 of 8

Minimum System Requirements Parameter Interface Host operating system - USB control Host operating system - Ethernet control Hardware Y control cable for USB and Ethernet (supplied) USB HID or HTTP Get/Post or Telnet protocols Requirements Windows 32/64 Bit operating system: Windows 98, Windows XP, Windows Vista, Windows 7, Windows 8 Linux support: 32/64 Bit operating system Any Windows, Mac, or Linux computer with a network port and Ethernet-TCP/IP (HTTP or Telnet protocols) support Pentium II or better, RAM 256 MB Model to be used with the supplied control cable only Absolute Maximum Ratings Parameter Ratings Operating Temperature 0 C to 50 C Storage Temperature -30 C to 70 C V USB Max. 6 V DC Voltage @ RF port 15 V RF Power(CW) @ RF port +25 dbm DC Voltage @ Reference Input 25 V RF Power(CW) @ Reference Input +13 dbm Connections Reference Input (BNC-Female) Signal Input (N-Typ-Male) Power & Control (Push-Pull connector) Permanent damage may occur if any of these limits are exceeded. Operating in the range between operating power limits and absolute maximum ratings for extended periods of time may result in reduced life and reliability. Page 4 of 8

Typical Performance Curves VSWR VSWR (:1) 1.15 0 C 1.12 +25 C +50 C 1.09 1.06 1.03 UUncertainty (db) 0.2 0.1 0.0-0.1-0.2-0.3 Uncertainty of Power Measurement @ +25 C -30 dbm -10 dbm 0 dbm +5 dbm +10 dbm +15 dbm +20 dbm 1.00-0.4 Linearity @ 25 O C 8% 6% -30 to 0 dbm 0 to +20 dbm Linearity (%) 4% 2% 0% -2% -4% -27 Typ. Input Power Threshhold for Frequency Measurement @ +25 C 500 Uncertainty of Frequency Measurement@+25 C Power In (dbm) -30-33 -36 Uncertainty (Hz) 300 100-100 -30 dbm -20 dbm -10 dbm 0 dbm +5 dbm +15 dbm +20 dbm -39-300 -42-500 Page 5 of 8

Outline Drawing (JL2029) Note 8 inch Outline Dimensions ( mm ) A B C D E F G H J K L 5.00 2.66 1.36 1.31 0.50 2.300 0.18 4.000 0.50 81 20 (127.0) (67.6) (34.5) (33.3) (12.7) (58.42) (4.6) (101.60) (12.7) (2057) (508) 8 to be used with the supplied USB cable only. WT. GRAMS 500 Page 6 of 8

Connection diagrams Connection diagram for USB control RJ45 connector - Not in use for USB control Connect to D.U.T. Push-Pull connector USB-RJ45-CBL-7+ USB Type A plug - Connect to computer USB socket Reference input (connect to external reference if needed) Connection diagram for Ethernet control, using power adapter RJ45 connector - Connected to LAN network port Connect to D.U.T. Push-Pull connector USB Type A plug - Connect to USB-AC/DC-5 power adaptor Reference input (connect to external reference if needed) USB-RJ45-CBL-7+ USB-AC/DC-5 Connection diagram for Ethernet control, using PoE system Connect to D.U.T. Push-Pull connector USB-RJ45-CBL-7+ Note: Commercially available PoE splitter not supplied by Mini-Circuits Reference input (connect to external reference if needed) RJ45 connector - for LAN data PoE Splitter RJ45 connector - Connected to PoE/LAN port USB Type A plug - for +5V power only Page 7 of 8

Ordering Information Model Description Integrated Frequency Counter & Power Meter Included Accessories Part No. Description Europe & IL US UK Australia & China USB-AC/DC-5 AC/DC Power Adapter with US, EU, IL, UK, AUS, and China two pin power plugs 9. Operating temperature: 0 C to +45 C, AC Input: 100-240V, 47-63 Hz, DC Output 5±0.25 V, I Max =1A FCPM-CD Software CD USB-RJ45-CBL-7+ 10 6.6 ft (2 m) Y data cable with USB Type-A and RJ45 plug connectors 9 Power plugs for other countries are also available, if you need a power plug for a country not listed in the table please contact apps@minicircuits.com or check http://www.minicircuits.com/contact/offices.html for regional offices e-mail and phone numbers. 10 to be used with the supplied control cable only. Optional Accessories USB-AC/DC-5 (spare) USB-RJ45-CBL-7+ (spare) NF-SM50+ Description AC/DC 5V DC Power Adapter with US, EU, IL, UK, AUS, and China power plugs 6.6 ft (2 m) Y data cable with USB Type-A and RJ45 plug connectors N-Type Female to SMA Male Adapter (For mating with SMA devices). Calibration Description CAL- Calibration Service Click Here Additional Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, Standard Terms ); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits website at www.minicircuits.com/mclstore/terms.jsp Page 8 of 8