Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Similar documents
Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

3 Cleaning. 4 Technical data

Guide for installers. METTLER TOLEDO MultiRange Explosion proof weighing system with IND226x weighing terminal.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Viper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge

Inductive sensor With analog output BI15-M30-LI-EXI

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08K-Y1

Operating instructions

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

User manual Version Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../...

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

RSCC. Load cells. Special features. Data sheet

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

DMP 331i / DMP 333i LMP 331 i

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Actuators IC 20, IC 40

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

S6-R READER. Installation and Operating Instructions

EXPlora. Introduction

Colour Explosion Proof Video Camera USER MANUAL VID-C

OM2000N INSTALLATION MANUAL

Process transmitter RMA422

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

Capacitance Level Measurement Electronic insert FEC 12

Installation instructions Ex frames

Installation instructions Cable transit device Roxtec RS ES Ex

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

MODEL HS35 DRAWWORKS OPTICAL ENCODER

Linear flow controls VFC Linear flow controls with actuator IFC

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

e 835 Instruction manual Stage Microphones

Pendant Light Fitting IEC Series 6470/2

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

CERTIFICATE of EU TYPE-EXAMINATION

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Installation instructions Roxtec RS ES Ex

Linear flow control with actuator IFC

Model ED 400 Drying and heating chambers Classic.Line with natural convection

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Horn loudspeaker, Ex proof, short/long flare

STC 160 Head-End Station Quad modulators

e 935 Instruction manual Stage Microphones

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

LED control gear Compact fixed output

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Pressure transmitter For applications in hazardous areas Model IS-3

ERbic Bus Interface Connector System. Catalog E /06 Edition 4

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

TRF STEP-DOWN TRANSFORMER USER MANUAL

4 Wiring Brochure Wiring and installation of specific control

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

DALI TOUCHPANEL BASIC TW. Operating and control unit

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

e 609 silver Stage Microphones

MKE 2 Gold. Instruction manual

PROPORTIONAL VALVES Sentronic plus

E15X-SUB Manual (1.2 EN)

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

Tube Rotator. User Guide. Version 1.2

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

EGM Einthoven Goldberger Module Type 701

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

Product Operation Manual

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Model KT 53 Cooling incubators with thermoelectric cooling

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

MKH 8060 Directional studio microphone

Model KBF 115 Constant climate chambers with large temperature / humidity range

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

Eddy Current Probe System

R&S AMU-Z7 Analog I/Q Combiner Technical Information

Pendant Light Fittings Series 6050

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Transcription:

Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support

System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the System solution Point Ex... 5 2.2 Typical configurations... 5 2.3 Description of the components... 6 3 Installation... 7 3.1 Setting up System solution Point Ex... 7 3.2 Equipotential bonding... 9 3.3 Connecting power supply... 9 3.4 Configuration... 9 3.5 Corner adjustment... 9 4 Making connection cables... 11 5 Technical data... 12 5.1 General technical data... 12 5.2 Intrinsically safe characteristic values of the Point Ex A/D converter... 13 5.3 Dimensional drawing... 13 6 Accessories... 14 7 Disposal... 15 Guide for installers 22010342C 11/03 3

Safety precautions System solution Point Ex 1 Safety precautions The System solution Point Ex is approved for operation in Zone 1 and 21 hazardous areas. Particular care is required when using weighing systems with the System solution Point Ex in hazardous areas. The code of practice is oriented to the "Safe Distribution" concept drawn up by METTLER TOLEDO. Competence Ex approval Operation Installation The System solution Point Ex may only be installed, maintained and repaired by authorised METTLER TOLEDO service personnel. No modifications may be made to the terminal and no repair work may be performed on the modules. Any weighing cells or system modules that are used must comply with the specifications contained in the installation instructions. Noncompliant equipment jeopardises the intrinsic safety of the system, cancels the "Ex" approval and renders any warranty or product liability claims null and void. The safety of the weighing system is only guaranteed when the weighing system is operated, installed and maintained in accordance with the respective instructions. Also comply with the following: the instructions for the system modules and weighing cells the regulations and standards in the respective country the statutory requirement for electrical equipment installed in hazardous areas in the respective country all instructions related to safety issued by the owner The explosion-protected weighing system must be checked to ensure compliance with the requirements for safety before being put into service for the first time, following any service work and every 3 years, at least. Prevent the build-up of static electricity. Always wear suitable working clothes when operating or performing service work in an hazardous area. Do not use protective coverings for the devices. Avoid damage to the system components. Only install or perform maintenance work on the weighing system in the hazardous areas if the following conditions are fulfilled: the intrinsically safe characteristic values and zone approval of the individual components are in accord with one another the owner has issued a permit ("spark permit" or "fire permit") the area has been rendered safe and the owner's safety co-ordinator has confirmed that there is no danger the necessary tools and any required protective clothing are provided (danger of the build-up of static electricity) The certification papers (certificates, manufacturer s declarations) must be present. Lay cabling securely so that it does not move and effectively protect it against damage. Only route cables into the housing of the system modules via the suitable cable gland and ensure proper seating of the seals. 4 Guide for installers 22010342C 11/03

System solution Point Ex System overview 2 System overview 2.1 Using the System solution Point Ex The System solution Point Ex is used for connecting intrinsically safe weighing cells or weighing platforms with intrinsically safe weighing cells. Tasks of the System solution Point Ex Application examples Conversion of analogue signals into digital signals Power supply for analogue weighing cells Expansion of DMS weighing platform conversion kits with analogue/digital electronics Construction of special scales, e.g. container scales, consisting of several DMS weighing cells and a container placed on top 2.2 Typical configurations 2.2.1 System solution Point Ex, weighing terminal IND560x, APS768x and DMS weighing cells Weighing cell 1* Point Ex System solution Weighing cell 2* Weighing cell 3* Weighing cell 4* * Minimum supply impedance of 87 The weighing cells must be approved for the hazardous area. The intrinsically safe characteristic values must be in agreement with those of the Point Ex system solution. Guide for installers 22010342C 11/03 5

System overview System solution Point Ex 2.2.2 System solution Point Ex, ID... weighing terminal and DMS weighing cells Hazardous area Safe area Weighing cell 1* Weighing cell 2* Weighing cell 3* System solution Point Ex Ex-i max. 100 m PSU Slotcard Point-Ex CL RS IDNet ID Terminal Weighing cell 4* alternatively * Weighing cells must be approved for the hazardous area. The intrinsically safe characteristic values must be in agreement with those of the Point Ex system solution. 2.3 Description of the components System solution Point Ex APS768x / PSU power supply unit IND560x weighing terminal Weighing cells Ignition protection type EN II 2G Ex ia IIC T4 Gb II 2D Ex tc IIIC IP67 T75 C Db Ignition protection type FM IS Class I, II, III; Division 1 Group A, B, C, D, E, F, G / T4 Temperature range 20 C to +60 C Protection type IP68 Connection cable 5 m See APS768x / PSU guide for installers. See IND560x installation manual. See prototype test certificate of weighing cells. 6 Guide for installers 22010342C 11/03

System solution Point Ex Installation 3 Installation 3.1 Setting up System solution Point Ex 3.1.1 Preparing System solution Point Ex EXPLOSION HAZARD Explosion hazard because not sufficiently dustproof! If the System solution Point Ex power supply unit is used in dust explosion hazard areas ensure that the degree of protection IP6x is ensured. In this respect ensure the correct position of the seals and the maximum tightening torque of the screwed connection. During every maintenance interval check the respective tightening torque and tighten if necessary. Screw M4 x 0.7 M12 x 1.5 M16 x 1.5 Max. tightening torque 1.2 Nm 4.0 Nm 2.0 Nm 1. Open cover of the System solution Point Ex by loosening the 12 screws. 2. Ensure that Point Ex mode is set. The respective mode must be identified on the PCB. 3.1.2 Connecting DMS weighing cells 70 6 6 Preparing cell cable 1. Strip cable end approx. 70 mm. 2. Shorten cable shield to 6 mm. 3. Strip the wire ends approx. 6 mm and twist them. 4. Push on the wire end ferrules and press them on firmly with a pair of crimping pliers. Attaching cable gland to cell cable Note Measures for shielding against incoming and outgoing interference are especially important with longer cell cables. The maximum interference immunity classes will only be achieved with careful and proper installation and wiring of all connected peripherals and weighing platforms. For this purpose, it is extremely important to connect the shielding on both sides in a professional manner. The CE-conformity of the entire system is the responsibility of the person commissioning the device. Guide for installers 22010342C 11/03 7

Installation System solution Point Ex Union nut Molded seal Metal housing Shield Seal Counter nut 1. Slide the union nut and moulded seal over the prepared cable. 2. Place cable shield over the contact. 3. Screw in metal housing with union nut. Connecting cell cable to the System solution Point Ex 1. Screw cable to the housing. Ensure proper seating of seal when doing so! 2. Identify weighing cells (1 to 4). 3. Connect weighing cell cables in accordance with the drawing on the System solution Point Ex. For 6-conductor weighing cells with a Sense connection, lead the Sense connections from each of two weighing cells to one terminal if necessary. Sense connection Weighing cell 4 Weighing cell 3 Weighing cell 2 Weighing cell 1 + + Sense Sense Power Signal + + Connecting System solution Point Ex to PSU Connecting System solution Point Ex to IND560x and APS768x See control drawings 22006477 in the PSU guide for installers (ME-22006472). See control drawing 22006397 in the APS768x guide for installers (ME- 22021223). 8 Guide for installers 22010342C 11/03

System solution Point Ex Installation 3.2 Equipotential bonding Equipotential bonding must be installed by an electrician authorised by the owner. METTLER TOLEDO Service only has a monitoring and consulting function here. Connect equipotential bonding (PA) of all devices (power supply unit, weighing terminal and weighing platform) in accordance with the terminal diagram and the country-specific regulations and standards. In the process it must be ensured that all device housings are connected to the same potential via the PA terminals no circulating current flows via the cable shielding for intrinsically safe circuits the neutral point for equipotential bonding is as close to the weighing system as possible 3.3 Connecting power supply See APS768x guide for installers. 3.4 Configuration The configuration of the System solution Point Ex is described in the service manual for the Point A/D converter. 3.5 Corner adjustment Corner compensation must be performed after configuration and calibration of the weighing system. 3.5.1 Checking the cornerload Checking of a multi-sensor weighing platform with four weighing cells is described in the following. 1. Place the test weight (1/3 of maximum load) in the center of the load plate and tare. 2. Load test weights in succession in the middle of each of the four quadrants, and note absolute value with sign. Adjustment is required for deviations greater than the permissible verification error limit. Guide for installers 22010342C 11/03 9

Installation System solution Point Ex 3.5.2 Adjusting corners Notes Begin the adjustment at the corner with the greatest deviation. The adjustment of weighing cell 1 occurs at the potentiometer pair 1, cell 2 at pair 2, etc. Potentiometer pair 4 Potentiometer pair 3 Hook switches Potentiometer pair 2 Potentiometer pair 1 Weighing cell 4 Weighing cell 3 Weighing cell 2 Weighing cell 1 1. Switch off weighing system. 2. Open all hook switches. 3. Move all potentiometers to the middle position. 4. With a positive deviation: Turn both potentiometers the same number of rotations to the right. With a negative deviation: Turn both potentiometers the same number of rotations to the left. 5. After completing corner adjustment, screw the cover of the system solution back on. Ensure proper seating of seal when doing so. 10 Guide for installers 22010342C 11/03

System solution Point Ex Making connection cables 4 Making connection cables EXPLOSION HAZARD Take the parameters of the cable used into consideration when checking the intrinsically safe parameters. Use only cables approved for use in the hazardous area. EXPLOSION HAZARD Explosion hazard because not sufficiently dustproof! If the System solution Point Ex power supply unit is used in dust explosion hazard areas ensure that the degree of protection IP6x is ensured. Customer-specific weighing platform cables for intrinsically safe circuits must be fabricated as follows: Cable Dim. A (system solution) Dim. B Max. (IND560x/PSU) length System solution 3 x 2 x 0.75 mm 2 80 mm 1 215 mm 1 20 m 1 Point Ex IND560x System solution Point Ex PSU 3 x 2 x 0.75 mm 2 80 mm 1 215 mm 1 100 m 1 Wire end ferrules with plastic collar, crimp connection Earthing cable gland A Cable as per country-specific regulations for intrinsically-safe circuits Push sleeve over wires and shield Cable shield B 1. Cut cable to length and strip cable ends according to dimension A/B. 2. Shorten shield on both sides to 10 mm. 3. Strip wire ends. 4. Crimp wire end ferrules onto wire ends with a crimping tool. 5. Push second rear section of earthing cable gland onto cable. 6. Push sleeve over wires and shield. Fold over cable shield. 7. Push on front section of cable gland and screw onto rear section. Guide for installers 22010342C 11/03 11

Technical data System solution Point Ex 5 Technical data 5.1 General technical data Metrological data Input signal range Supply voltage Weighing platform impedance Smallest perm. verif. incr. Fraction of the error limit (P i ) 0 to 3 mv/v 6 V 87.5 to 1100 in conjunction with PSUx and supply through U6 87.5 to 1100 in conjunction with PSU/..-Ex and the Point-Ex slotcard 250 to 1100 in conjunction with PSU/..-Ex and the TBrick-Ex slotcard 0.40 V/e 0.5 Number of weighing cells max. 4 Number of verifiable increment values max. 7500 e Scales configuration Single range (SR) Multi-range (MR), max. three areas Multi-interval (MI), max. three intervals Temperature range Verification class III 10 C to +40 C Housing Housing protection type Metric terminal box IP68 Housing type Chrome-nickel-steel (1.4301) Operating modes Point Ex mode Connection of U1 (5) and U2 (10) Optional mode Connection of U1 (5) The mode is set at the factory and is identified on the PCB. Weight (incl. cables) Application location Ex-i connection cable Dimensions L x W x H Relative humidity net 1.7 kg to be used only in interiors From the factory 5 m long cable enclosed, on both sides cable gland M16x1.5 preassembled. If required longer cable possible, see chapter 4. 350 x 84 x 44 mm (without connection parts) 20 % 80 %, non-condensing 12 Guide for installers 22010342C 11/03

System solution Point Ex Technical data 5.2 Intrinsically safe characteristic values of the Point Ex A/D converter Input voltages U i I i P i C i L i U1 (5) 8.7 V 250 ma 1.2 W U2 (10) 12.7 V 330 ma 2.0 W 50 nf Interface signals U i I i P i C i L i RXD (6) 15 V 74 ma 0.8 W 10 nf TXD (7) 15 V 74 ma 0.8 W 10 nf Output values of weighing cell connection U o I o P o C o L o (EX+) 8 V 250 ma 1.2 W 100 nf 300 H 5.3 Dimensional drawing Metric terminal box 84 44 315 350 320 50 Dim. in mm Guide for installers 22010342C 11/03 13

Accessories System solution Point Ex 6 Accessories Graphic Designation Order No. Cable For intrinsically safe circuits, Ex-i 3 x 2 x 0.75 mm 2, shielded, 100 m 00 504 638 Wire end ferrules H 0.75 / 13, with plastic collar, 100 pcs. 00 504 639 Cable coupler M16 x 1.5 EEx e II, 6 pcs. 22 006 708 For spare parts, see the service manual of the Point A/D converter. 14 Guide for installers 22010342C 11/03

System solution Point Ex Disposal 7 Disposal In conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE), this device may not be disposed of in domestic waste. This also applies to countries outside the EU as per their specific regulations. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environmental protection. Guide for installers 22010342C 11/03 15

*22010342C* 22010342C Subject to technical changes Mettler-Toledo (Albstadt) GmbH 11/03 Printed in Germany 22010342C Mettler-Toledo (Albstadt) GmbH D-72458 Albstadt Tel. ++49-7431-14 0, Fax ++49-7431-14 232 Internet: http://www.mt.com