Agilent N4876A 28 Gb/s Multiplexer 2:1

Similar documents
Agilent N4876A 28 Gb/s Multiplexer 2:1

Agilent N5183A MXG Microwave Signal Generator

Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

Keysight Technologies N4974A PRBS Generator 44 Gb/s. Data Sheet

Electrical and Optical Clock Data Recovery Solutions up to 32 Gb/s

Agilent E4887A HDMI TMDS Signal Generator Platform

Keysight Technologies M8048A ISI Channels

CAN/LIN Measurements (Option AMS) for Agilent s InfiniiVision Series Oscilloscopes

Keysight Technologies ad Integrated RF Test Solution

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Agilent Understanding the Agilent 34405A DMM Operation Application Note

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Exceptional performance

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Agilent 87405C 100 MHz to 18 GHz Preamplifier

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Agilent 83000A Series Microwave System Amplifiers

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

Agilent N4965A Multi-Channel BERT 12.5 Gb/s Data Sheet

Agilent Series Harmonic Mixers

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Keysight Technologies Achieve High-Quality Compliance Test Results Using A Top-Quality Test Fixture. Application Note

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

Agilent Series Preselected Millimeter Mixers

Keysight N1085A PAM-4 Measurement Application For 86100D DCA-X Series Oscilloscopes. Data Sheet

Agilent Technologies N5454A Segmented Memory Acquisition for Agilent InfiniiVision Series Oscilloscopes

Keysight Technologies N4917A Optical Receiver Stress Test Solution. Data Sheet Version 1.3 New: Extension to 8G Fibre Channel

Time-Saving Features in Economy Oscilloscopes Streamline Test

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Electrical Sampling Modules

Agilent ESA Series Spectrum Analyzers

Agilent M9362A-D01-F26 PXIe Quad Downconverter

Keysight N4965A Multi-Channel BERT 12.5 Gb/s. Data Sheet

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

Agilent Technologies Series of RF and Universal Frequency Counter/Timers. Family Overview

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster

46 GBaud Multi-Format Optical Transmitter

Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

FlexRay Physical Layer Eye-diagram Mask Testing

Keysight E4887A HDMI TMDS Signal Generator Platform. Data Sheet Version 2.1

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

Agilent E6701G GSM/GPRS and E6704A EGPRS Lab Applications

Arbitrary Waveform Generators AWGSYNC01 Synchronization Hub Datasheet

Full-featured CW Microwave Counters for Field, Factory or Lab

FlexRay Measurements (Option FLX) for Agilent s InfiniiVision Series Oscilloscopes

Agilent 11713A Attenuator/Switch Driver

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Single-Output 2000 W

Agilent CSA Spectrum Analyzer N1996A

Agilent Technologies Pulse Pattern and Data Generators Digital Stimulus Solutions

M809256PA OIF-CEI CEI-56G Pre-Compliance Receiver Test Application

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

Data Pattern Generator

Mixed Analog and Digital Signal Debug and Analysis Using a Mixed-Signal Oscilloscope Wireless LAN Example Application

Agilent E3238 VHF/UHF Voice Activity Detection System

R&S ZN-Z154 Calibration Unit Specifications

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

Agilent Test Solutions for HDMI Thorough characterization and validation of HDMI-based designs

Microwave Counter, Power Meter and DVM in One Portable Package

N4917BACA Optical Receiver Stress Test Solution 100 Gb/s Ethernet

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

R&S ZN-Z85 Switch Matrix Specifications

Selecting the Right Oscilloscope for Protocol Analysis Applications

Digital Storage Oscilloscopes 2550 Series


Optical Sampling Modules 80C01 80C02 80C07B 80C08C 80C10 80C11 80C12

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

Agilent 87075C Multiport Test Set Product Overview

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

serial cell generator & analyzer central line interface clk in** data in main out detect enable HP E4853A (**: opt 002)

Logic Analysis Fundamentals

Keysight Technologies ad Waveform Generation & Analysis Testbed, Reference Solution

Optical Sampling Modules 80C02 80C07B 80C08C 80C10 80C10B 80C11 80C12

Data Pattern Generator

A Simple, Yet Powerful Method to Characterize Differential Interconnects

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors

Evaluating Oscilloscope Vertical Noise Characteristics

Keysight Technologies N5998A HDMI Protocol/Audio/Video Analyzer and Generator

Agilent M9361A PXI Downconverter

PBR-310C E-BERT. 10Gb/s BERT System with Eye Diagram Tracer

32 G/64 Gbaud Multi Channel PAM4 BERT

Agilent 8153A Lightwave Multimeter Technical Specifications

Keysight Technologies Segmented Memory Acquisition for InfiniiVision Series Oscilloscopes. Data Sheet

Keysight Technologies Millimeter Wave Frequency Extenders From Virginia Diodes Inc. for the Keysight X-Series Signal Analyzers. Technical Overview

C-PHY Essentials Transmitter Test Solution TekExpress C-PHY Essentials Tx

Agilent E5100A Network Analyzer

R&S ZVA110 Vector Network Analyzer Specifications

Tektronix Video Signal Generators

Keysight Technologies Using Oscilloscope Segmented Memory for Serial Bus Applications. Application Note

Keysight Technologies Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details. Application Note

Keysight Technologies

Transcription:

Agilent N4876A 28 Gb/s Multiplexer 2:1 Data Sheet Revision 1.0 Features and Benefits Variable data rate up to 28.4 Gb/s Multiplexes two generator channels Front-end box for J-BERT or ParBERT Control via J-BERT or with stand-alone user interface via USB/LAN interface Small size

Applications Accurate characterization up to 28 Gb/s The N4876A 28 Gb/s Multiplexer allows to extend the pattern generator data rate of the J-BERT N4903B and ParBERT 81250A up to 28.4 Gb/s. Design and test engineers in the semiconductor, communications, storage and computer industry can now accurately characterize the next generation of serial interfaces operating at bit rates of up to 28.4 Gb/s. With its excellent performance the N4876A helps to optimize design margins by minimizing the influence of the test equipment on measurement results. The multiplexer is transparent to jitter, so when using it with the J-BERT N4903B, calibrated RJ and PJ can be generated. The small size allows locating the device under test closely to the s of the N4876A. Figure 1. The N4876A multiplexer offers excellent performance. The example shows a 28.4 Gb/s PRBS signal, using J-BERT s internal clock, PRBS15 and is captured with Agilent 86117A DCA-J Module Affordable path to 28 Gb/s pattern generation The N4876A multiplexer doubles the pattern generator data rate by multiplexing two pattern generator channels. The N4876A extends the variable generator data rate of J-BERT N4903B up to 28.4 Gb/s and of ParBERT 81250A up to 27.0 Gb/s. It s an affordable path to extend the operating rate up to 28.4 Gb/s by just adding the multiplexer front-end to a 12.5/13.5/14.2 Gb/s BERT pattern generator. Accurate eye, mask and jitter analysis The Agilent Infiniium DCA-J wide bandwidth oscilloscope offers the most precise waveform, eye, mask and jitter analysis of optical or electrical and advanced eye analysis options. J-BERT N4903B Up to 14.2 Gb/s data 2 4 6 8 Main data 1 3 5 7 clock N4876A Up to 28.4 Gb/s 1 2 3 4 5 6 7 8 9 Figure 2. Two generator channels are multiplexed by the N4876A, doubling the generator data rate and interleaving the pattern bits from aux data and main data input. Example shows setup with J-BERT N4903B. 2

J-BERT N4903B Clock Infiniium DCA-J 86100C data Main data clock N4876A Multiplexer Up to 28.4 Gb/s Transmitter under test Optical Or electical Figure 3. Transmitter test setup with N4876A, J-BERT N4903B and Infiniium DCA-J. J-BERT N4903B data N4876A Multiplexer Data clock Golden TX or Agilent E/O Up to 28.4 Gb/s Data to J-BERTED Attenuator Receiver under test 8164B Lightwave Measurement System Figure 4. Receiver Tolerance Test Setup with N4876A, J-BERT N4903B using error detector clocked from main clock out and undersampling technique. 3

Specifications N4876A Figure 5. Front panel view of N4876A. Table 1. Specifications for multiplexer s Output data rate Output format Output amplitude 1.25 Gb/s to 27.0 Gb/s (28.4 Gb/s when using J-BERT N4903B option D14) NRZ 0.05 V pp to 1.800 Vpp, 5 mv resolution Output voltage -2.00 V to + 3.00 V window External termination - 2.00 V to +3.00 V voltage Output transition times 10 ps typ. (20% - 80%) 15 ps typ. (10% - 90%) Differential skew 0 ps typ. Intrinsic jitter 1 ps rms typical with disabled jitter sources and J-BERT N4903B internal clock Jitter feed-through Transparent for timing jitter on clock (data must be provided accordingly). S.I. and ISI shall be added after multiplexer. Notice: after multiplexing 1UI will be 2 UI Variable Clk/2 jitter 45% to 55% or -10 ps to + 10 ps whatever is less. Notice: this means that eye 1 can be up to 10 ps longer/shorter than eye 2 Crossing point Adjustable 20% to 80% typical Outputs on/off Via J-BERT UI Interface Differential or single-ended, DC coupled, 50 Ω impedance Connectors 2.4 mm, female Table 2. Specifications for multiplexer inputs Input voltage data inputs Input format Input voltage clock input Interface Connectors Hi-level: 0 V nominal, max: +0.4 V Low-level: -0.8 V nominal, min.: -1.2 V, DC coupled Data: NRZ; Clock: RZ, full-rate 0.4 Vpp nominal, max: 800 mv in +/- 8V window, AC-coupled single-ended, 50 Ω input impedance SMA, female Target Applications for N4876A IEEE 802.3 ba 100GBASE-LR4, -ER4 interfaces operating at data rates of 25.78125 Gb/s OIF CEI backplanes operating between 19.9 and 28 Gb/s T11 16x or 32x Fibre Channel Clean generator for transmitter test Stressed generator for receiver tolerance testing Clock/2 jitter injection Figure 6. The N4876A allows generating bit streams where even bits have a longer (or shorter) pulse duration than odd bits. (Clock/2 jitter). Example is captured with Agilent 86118A and 86107A precision time base module. 4

Specifications N4876A Table 3. General characteristics Operating temperature Storage temperature Operating humidity Storage humidity Power requirements Physical dimensions Weight net Weight shipping Recommended recalibration period Warranty period 5 ºC to 40 ºC (-23 ºF to 104 ºF) Auto-adjustment required after warm-up. If operating temperature changes > 5 ºC auto adjustment is needed -40 ºC to +70 ºC (-65 ºF to 158 ºF) 95% relative humidity, non-condensing 50% relative humidity 100V to 240V +/-10%, 50 Hz to 60 Hz, 80 VA Bench top with bumper: 228 x 59 x 360 mm (9.0 x 2.3 x 14.2 in) Rack mount without bumper: ½ x 19 width, 1U height: 213 x 44.5 x 360 mm (8.4 x 1.8 x 14.2 in) 2,9 kg (6.4 lb) 5.5 kg (12.1 lb) 1 year recommended. For calibration services see ordering information 1 year return to Agilent. See ordering instructions for extended warranty Control and Programming The N4876A can be controlled via USB interface from J-BERT N4903B user interface or from a stand-alone user interface with programming examples. Figure 7. Controlling the N4876A multiplexer parameters from a stand-alone user interface. Remote control interfaces: Connectivity: USB 2.0, LAN (rear panel) Programming language: SCPI Via J-BERT N4903B: via USB, required SW rev. 6.7x or later Stand-alone user interface: System requirements: Microsoft Windows, Agilent IO library suite rev. 15.5, Microsoft.NET 2.0. Figure 8. Rear panel view of N4876A. 5

Specifications N4876A Ordering Information Regulatory standards: Safety: IEC61010-1:2001, EN61010-1:2001, CAN/CSA-C22 No 61010-04, UL 61010-1:2004 EMC: IEC 61326-1:2005, EN 61326-1:2006 Environmental: RoHS compliant Quality management: ISO 9001, ISO 14001 Specification assumptions: The specifications in this document describe the instruments warranted performance. Non-warranted values are described as typical. All specifications are valid in a range from 5 ºC to 40 ºC ambient temperature after a warm-up time of 30 minutes and after Auto-Adjustment. If not otherwise stated, all inputs and s need to be terminated with 50 Ω to GND. All specifications, if not otherwise stated, are valid using the recommended cable set N4910A (2.4 mm, 24 matched pair). Accessories included in N4876A-001: three 50 Ω terminations, three adapters 2.4 mm to 3.5 mm, USB cable, UK6 test report, USB stick with getting started guide, user software and documentation Table 4. Ordering information for N4876A 28 Gb/s Multiplexer 2:1 N4876A-001 Recommended accessories 2.4 mm matched cable pair N4910A Matched cable kit for N4915A-011 connecting N4876A with J-BERT N4903B (2 x 2.4 mm to SMA for data/aux data, 1x SMA to SMA for clk) Rack mount kit E5810A-100 Warranty and calibration services Return-to-Agilent On-site (US only) Productivity assistance Rack mount kit R1280,R1282 R1288A,R1298A R1380-N49xx E5810A-100 Recommended J-BERT configuration: N4903B with Option -C13, -002, -D14; Optional: -J10 (jitter sources) and all others Related Agilent Literature Table 6. Related literature for N4876A Publication title J-BERT N4903B Data Sheet 81250A ParBERT Data Sheet Pub number 5990-3217EN 5968-9188EN Learn more: www.agilent.com/find/n4876 www.agilent.com/find/contactus 6

www.agilent.com www.agilent.com/find/n4876 www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Latin America 305 269 7500 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 43 (0) 1 360 277 1571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2009 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2010 Printed in USA, June 21, 2010 5990-5247EN 7