ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

Similar documents
Wall-/Pipe-Mount Level Indicator

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

ABB Instrumentation Operating Instructions Series Transmitters. Second Retransmission Output Supplement All Models.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Level Measurement silometer FMC 420, FMC 423

Process Transmitter RMA 422

UNIGAS Hand-held combustion gas analyzer with 3 sensors

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Model JDF Field Indicator

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

SQM40/41 Actuators for air and gas dampers

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Process transmitter RMA422

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Panel-mounting Thermostats EM Series

Capacitance Limit Detection nivotester FTC 420/421/422

Pendant Light Fitting IEC Series 6470/2

Modular Lube Lubrication Systems System Controls

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Single Point Flow Monitor SW118 SW119

Safety Light Curtain Orion1 Extended

02/11/2015

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Display Information Type Backlit blue on white STN Type

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

DCP100 Digital Control Programmer Specifications

263 Series LED Bargraph Indicator and Controllers

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

2291 Guided Wave Radar Level Transmitter

TFR5 Room or outdoor temperature sensor. CombiTemp TM

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

INST No.CP CP Computing unit. Instruction Manual. Important Notice. Keep this manual with due care after understanding operation.

Actuators IC 20, IC 40

DATA SHEET Panorama Rudder Indicator, TRI-2

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Magnecraft Power Relays

Model IQ4-PC User Manual Revision Date:

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Micro-DCI 53ML5100 Manual Loader

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Dissolved Oxygen Transmitter

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

SCALE & WEIGHT DISPLAYS

CONDITIONER TERMINAL BLOCK 8 ISOLATED ANALOG INPUTS STB 582

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Lt DELTA USA, Inc

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

LED Driver Compact fixed output

Dissolved Oxygen Transmitter

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

DMP 331i / DMP 333i LMP 331 i

General Specifications

LAUREL ELECTRONICS, INC.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Micro-Machined Silicon Transducers

LED Driver Compact fixed output

Digital output modules

Liquid Level Sensor Type AKS 4100U

RMA42. Technical Information

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Linear flow controls VFC Linear flow controls with actuator IFC

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

LED Driver Linear / area fixed output

SPECIFICATION NO NOTE

Linear flow control with actuator IFC

Capacitive sensor BCT5-S18-UP6X2T-H1151

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

FLOMAT Electromagnetic Insertion Flowmeter

Set Point Controller OC557. Operator s Manual

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

TFRN Industrial RTD temperature sensor. CombiTemp TM

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

AS09..S 3-pole Contactors - Spring Terminals

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Transcription:

ABB MEASUREMENT & ANALYTICS DATA SHEET AZ00 series Zirconia oxygen analyzer for small boiler applications

AZ 00 SE RIE S Z I RCON I A OX YG EN ANALY ZE R FOR SMALL BOILE R APPLIC ATIONS DS/AZ00-E N RE V. I Measurement made easy Economic, efficient and environmentally friendly combustion control Ideal for small gas/oil fired boilers Cost-effective solution for OEM outlets with a quick return on end-user investment Continuous on-line measurement at less than the price of a spot check portable instrument Provides EN400 performance data at an affordable price NEMA 4X / IP66 protection for the probe Linear or logarithmic ranges 0 to 5 % up to 0 to 5 % linear decades logarithmic from 0.0 to 5 % Comprehensive diagnostics and built-in software protection ensures security and confidence in operation

AZ00 SERIES ZIRCONIA OXYGEN ANALYZER FOR SMALL BOILER APPLICATIONS DS/AZ00-EN REV. I Introduction The AZ00 Zirconia Oxygen Analyzer is a versatile system designed primarily for the OEM boiler and burner controls market. The system is a low-temperature type designed to work in process temperatures up to 800 C (47 F) and with a maximum sensor mounting flange temperature of 400 C (75 F). The analyzer provides oxygen computation, with readout and retransmission, based on the probe mv output signal. The output signal (E mv) is Nernstian in form and follows the equation: E (mv) = 0.0496T(log0 P0 / P) ± CmV Where: T = Absolute temperature P0 = Reference O partial pressure P = Sample O partial pressure C = Cell constant (mv zero offset) 0.0496 = Faraday s gas constant Probe design The probe uses the proven and innovative ABB electrode and cell design technology which has been so reliable in other ABB zirconia probe designs. The flexible probe design gives a range of intake tube lengths to suit all applications and an optional filter/flame arrester making it safe for use where groups IIB and IIC gases may occur in the process being measured. The probe has options of male thread NPT or BSPT mountings. As with all previous ABB designs of low temperature probes, the AZ00 probe is site-serviceable. Transmitter design The transmitter has, as standard, high/low alarm relays and a single linear or logarithmic isolated retransmission. Display features include %O, cell temperature, heater control output, cell mv, alarm set points, calibration sequence diagnostics and output settings. At system startup the transmitter controls the level of power to the mains-powered heater within the probe to eliminate the risk of thermal shock to the sensor. Based on the proven 4600 Series of transmitters, the AZ00 transmitters are environmentally protected to NEMA 4X (IP65)*, and meet the requirements EN66 for industrial locations. The AZ00 transmitters have a green, backlit LCD display and four tactile membrane switches for operation and programming. The measured value display is a 5-digit, 7-segment LCD, while the information display is a 6-character, single line, dot-matrix. The information display can be user-programmed for display in English, French, German or Spanish. The switch enables movement from the Operating Page to the oxygen calibration sequence. Use of the appropriate security code allows further access to the pages for Setup Outputs and Electrical Calibration. The switch is used to select the various programming pages, while the and switches change the programmable values. * Refer to Specification Transmitter for full details. As the sensor housing is located on the outside of the duct wall, diffusion of reference air into the sensor housing is sufficient; thus eliminating the need for an air pump or instrument air supply. The reference air diffuses into the housing through a porous membrane which restricts entry to air only and maintains the IP66 (NEMA 4X) protection.

4 AZ00 SERIES ZIRCONIA OXYGEN ANALYZER FOR SMALL BOILER APPLICATIONS DS/AZ00-EN REV. I Specification transmitter Display Measured value 5-digit x 7-segment, backlit LCD Information 6-character, single-line, dot-matrix, backlit LCD Parameters % O (0 to 5 %) Cell temperature Cell mv Two alarm set points Alarm can be configured as a general alarm for any of the following: THC open circuit + check THC open circuit, short circuit or reversed Cell warming up Calibration failed Cell stability check Power failure Accuracies Oxygen concentration (display and retransmission) % of reading or ±0.% O (whichever is the greater) Display resolution ± digit Environmental data Operating temperature limits 5 to 55 C ( to F) all functions 0 to 70 C ( 4 to 58 F) retransmission Storage temperature 5 to 75 C ( to F) Operating humidity limits Up to 95 % RH non-condensing Power supply Voltage requirements 00 to 0 V, 00 to 60 V 50 / 60 Hz Nom. 5 / 0 V AC 50 / 60 Hz Power consumption (total system) VA at start up (sensor) 6 VA at start up (transmitter) 47 VA operational Insulation Mains to earth (line to ground) kv RMS Outputs and set points No. of relays Two Relay contacts Single pole changeover Rating A 50 V AC A 50 V DC Loading (non-inductive) 750 VA 0 W Loading ( inductive) 75 VA W Insulation kv RMS contacts to earth (ground) No. of alarm set points Two Set point adjustment Programmable Set point hysteresis ± % of set point (fixed) Local set point annunciation Red LED Retransmission One fully isolated retransmission output Linear output Range 0 to 5 % O programmable Minimum span 5 % Logarithmic output Range 0. to 5 % O programmable Minimum span any decades in range Output current 0 to 0 ma, 0 to 0 ma or 4 to 0 ma user-programmable Resolution 0. % at 0 ma, 0.05 % at 0 ma Max. load resistance 750 Ω ( 0 ma max.) Output loop test Output loop test at 0 %, 5 %, 50 %, 75 % and 00 % of output span

AZ00 SERIES ZIRCONIA OXYGEN ANALYZER FOR SMALL BOILER APPLICATIONS DS/AZ00-EN REV. I 5 Mechanical data Mounting options Wall-mount Post-mount Panel-mount Protection to NEMA 4X (IP65) Wall / post mount transmitter Panel-mount transmitter (front only) Overall dimensions Wall-mount transmitter: 60 wide x 4 high x 68 mm deep (6. wide x 8.4 high x.68 in. deep) Panel-mount transmitter: 96 x 96 x 9 mm deep (.78 x.78 x 7.5 in. deep) Weight Wall-mount transmitter.0 kg (4.4 lb) Panel-mount transmitter.5 kg (. lb) Post-mount kit.5 kg (. lb) System Accuracy Display % of reading or ±0. % O (whichever is the greater), for 0 C (86 F) ambient temperature change Retransmission % of reading or ±0. % O (whichever is the greater), for 0 C (86 F) ambient temperature change Error due to power supply variation <0. % O for ±0 % variation from normal supply voltage Error due to flue wall temperature change 0.07 % of reading/ C (0.008 % of reading/ F) * for point calibration against certified test gases

6 AZ00 SERIES ZIRCONIA OXYGEN ANALYZER FOR SMALL BOILER APPLICATIONS DS/AZ00-EN REV. I Specification Probe Environmental data Process gas temperature 0 to 800 C ( 4 to 47 F) Maximum sensor flange temperature 400 C ( 75 F) Ambient air temperature 0 to 70 C ( 4 to 58 F) Environmental protection NEMA 4X / IP66 ( hose down) Electrical data Signal cable 6-way, multicore, screened cable with copper conductors available in standard lengths of 5, 50 or 00 m (8.5, 6.5 or 5 ft.) Thermocouple NiCr/NiAl Pt.4 BS497 Type K Mechanical Data Insertion lengths 00, 50, 500 or 650 mm (7.9,.8, 9.7 or 5.6 in.) Response time s Time to t90 5s (typical) Mountings in. NPT, in. BSPT or Adapter/ Standoff spool to suit the 0.4m ZFG mounting plate Overall dimensions See page 8 Weight Probe complete with mounting flange and the following length intakes: 00 mm (7.9 in.) 4.8 kg (0.6 lb) 50 mm (.8 in.) 5. kg (. lb) 500 mm (9.7 in.) 5.4 kg (.9 lb) 650 mm ( 5.6 in.) 5.7 kg (.5 lb) Serviceability Site-serviceable (replaceable sensor / oven assembly, filter / flame arrester and intake tubes)

AZ00 SERIES ZIRCONIA OXYGEN ANALYZER FOR SMALL BOILER APPLICATIONS DS/AZ00-EN REV. I 7 Electrical connections Probe Transmitter (wall-mount shown for example only) Scr + Cell Ctrl TB + 4567 THC+ Com Cell+ White Black Red + THC Cell THC ACJC Common Screen Blue Brown Red White Green Black ACJC Green Link TB TX + TX Cell heater control Brown Blue HTR N Green/Yellow HTR 5V Blue Brown 0V Retransmission output + Screen Relay NC C NO NC C NO Relay N G/Yellow Blue TB7 L Brown TB 4567 White THC+ Black Com Red Cell+ ACJC Green Link Note. The probe and transmitter earth must be common at the junction box Mains supply connections Retransmission + output Screen NC Relay C NO NC Relay C NO NC = normally closed C = common NO = normally open A 4 5 6 7 8 9 E N L TB RX + RX Cell heater control Brown Brown Blue Blue G/Yellow Mains supply junction box Mains power Screen Blue Brown Link Green Red Black White B Green/Yellow 4 5 6 7 8 9 0 + N Blue TB7 Screen L Brown Cell heater control To probe Mains supply Mains supply To probe Wall- /Pipe-mounted transmitter connections Panel-mounted transmitter connections System connections

8 AZ00 SERIES ZIRCONIA OXYGEN ANALYZER FOR SMALL BOILER APPLICATIONS DS/AZ00-EN REV. I Overall dimensions Dimensions in mm (in.) 60 (6.) 68 (.68) Dimensions in mm (in.) +0.8 +0.0 96 (.78) 9 (.6 ) 0.0 0.0 96 (.78) Panel cut-out +0.8 9 0.0 +0.0 (.6 ) 0.0 50 (9.84) 4 (8.4) (9.) (0.47) 9 (7.5) 69 (.7) Wall-mount transmitter Panel-mount transmitter Dimensions in mm (in.) Nominal insertion length 00, 50 or 650 (7.87,.78 or 5.6) 4 (.4) 70 (0.6) (0.5) 00 Sq Ø 95 (.7) (.9) Ø 7 (5) Ø.5 in. NPS SCH5 (Ø 4.6 mm) Mounting adapter in. NPT or in. BSPT taper thread Probe

AZ00 SERIES ZIRCONIA OXYGEN ANALYZER FOR SMALL BOILER APPLICATIONS DS/AZ00-EN REV. I 9 Ordering information AZ00 series zirconia oxygen analyzer for small boiler applications AZ X X/ X X X X X X Probe Not required No purge with arrester Sample tube length 00 mm (7.9 in.) 50 mm (.8 in.) 500 mm (9.7 in.) 650 mm (5.6 in.) Probe mount Not required in. NPT in. BSP Transmitter Not required 0 V wall-mount 0 V post-mount 0 V panel-mount 5 V wall-mount 5 V post-mount 5 V panel-mount Signal cable Not required 0 m (.8 ft.) 5 m (8 ft.) 50 m (64 ft.) 00 m (8 ft.) (maximum) Approvals CE only 0 Language English German French Spanish Configuration ABB (Standard) 0 0 4 0 0 4 5 6 0 4 4 Sales Service

0 AZ00 SERIES ZIRCONIA OXYGEN ANALYZER FOR SMALL BOILER APPLICATIONS DS/AZ00-EN REV. I Notes

AZ 00 S E RIE S Z I R CON I A OX YG EN ANALY ZE R FOR SMALL BOILE R APPLIC ATIONS DS/AZ00-E N RE V. I

ABB Limited Measurement & Analytics Oldends Lane, Stonehouse Gloucestershire, GL0 TA UK Tel: +44 (0)45 86 66 Fax: +44 (0)45 89 67 ABB Inc. Measurement & Analytics 5 E. County Line Road Warminster, PA 8974 USA Tel: + 5 674 6000 Fax: + 5 674 78 abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 07 ABB. All rights reserved. DS/AZ00-EN Rev. I.07