Copyright 2014 ZES ZIMMER Electronic Systems GmbH. LMG600 Series Introduction

Similar documents
MICROMASTER Encoder Module

R&S SMBV-Z1 Reference Frequency Converter Specifications

2 MHz Lock-In Amplifier

4 MHz Lock-In Amplifier

Versatile EMS and EMI measurements for the automobile sector

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Ensemble QLAB. Stand-Alone, 1-4 Axes Piezo Motion Controller. Control 1 to 4 axes of piezo nanopositioning stages in open- or closed-loop operation

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Industriefunkuhren. Technical Manual. OEM Sync-Module FE1000 (IRIG-B) ENGLISH

New Generation of MEA-Systems: MEA2100-System

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

SC26 Magnetic Field Cancelling System

Installation & Operational Manual

EDL8 Race Dash Manual Engine Management Systems

Major Differences Between the DT9847 Series Modules

HOBO H Energy Logger

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Synthesized Block Up- and Downconverter Indoor / Outdoor

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

PQ-Box 100 Quick Start Instructions

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels

DA E: Series of Narrowband or Wideband Distribution Amplifiers

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH)

LAUREL ELECTRONICS, INC.

Fluke 190-Series II Firmware Upgrade V11.44

2 MHz Lock-In Amplifier

DPD80 Visible Datasheet

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Single cable multiswich programmer PC102W

IP LIVE PRODUCTION UNIT NXL-IP55

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Noise Detector ND-1 Operating Manual

DPD80 Infrared Datasheet

imso-104 Manual Revised July 19, 2012

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

Experiment 13 Sampling and reconstruction

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

DIVERSITY DVB-T RECEIVER (DDR)

Choosing an Oscilloscope

R&S ZVA110 Vector Network Analyzer Specifications

CI-218 / CI-303 / CI430

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

imso-104 Manual Revised August 5, 2011

innovative technology to keep you a step ahead Tailored to Simplify Installation and Troubleshooting of RF Signals

Synthesized Block Up- and Downconverter

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

J6 User Manual. User Manual. Multi-Screen Splicing Processor J6. Xi an NovaStar Tech Co., Ltd. Rev1.0.1 NS

We bring quality to light. SNT 10 DC Power Supply

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Digital Storage Oscilloscopes 2550 Series

It will cause malfunction if the monitor is operating with unspecified power supply

CHAPTER 3 SEPARATION OF CONDUCTED EMI

FS3. Quick Start Guide. Overview. FS3 Control

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Multiband Noise Reduction Component for PurePath Studio Portable Audio Devices

R&S HF907DC SHF Downconverter Specifications

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Getting Started with the LabVIEW Sound and Vibration Toolkit

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

ENGINEERING COMMITTEE

HAL Series. Versatile range of production line testers.

CDMA2000 1xRTT / 1xEV-DO Measurement of time relationship between CDMA RF signal and PP2S clock

SHENZHEN H&Y TECHNOLOGY CO., LTD

E X P E R I M E N T 1

SingMai Electronics SM06. Advanced Composite Video Interface: DVI/HD-SDI to acvi converter module. User Manual. Revision th December 2016

DMC550 Technical Reference

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

DA : Series of Narrowband or Wideband Distribution Amplifiers

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

IP LIVE PRODUCTION UNIT NXL-IP55 USO RESTRITO. OPERATION MANUAL 1st Edition (Revised 2) [English]

Dac3 White Paper. These Dac3 goals where to be achieved through the application and use of optimum solutions for:

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Modular Block Converter Systems

DVI KVM Extender DVIVision 7.4

Pre-processing of revolution speed data in ArtemiS SUITE 1

MULTIMIX 8/4 DIGITAL AUDIO-PROCESSING

PT-TX400 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

HD-CM HORIZON DIGITAL CABLE METER

Manual FERROFISH A16 MK-II. advanced audio applications. professional 16 channel AD/DA converter

Agilent Technologies 54522A

R&S TS-PMB Switch Matrix Module High-density, 90-channel, full matrix relay multiplexer module

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

PicoScope 3000 Series Automotive User guide

ARCHITECTURAL AND ENGINEERING SPECIFICATION DIVISION - LEVEL 1 28 ELECTRONIC SAFETY AND SECURITY LEVEL ELECTRONIC SURVEILLANCE LEVEL

Gamma instabus. Technical product information

Standard RS232 RS ma

Transcription:

LMG600 Series Introduction

ZES ZIMMER The Touchstone in Power Analysis Precision in Power is the guideline of. ZES ZIMMER is a German high-tech company specialized in developing, manufacturing and distribution of precision instruments and systems for measuring electrical power, energy, harmonics, flicker and power quality. The company is based in Oberursel, Germany, and was founded in 1980 by Dipl.-Ing. Georg Zimmer. It is one of the technical leaders in the field of power analysis worldwide. ZES ZIMMER offers professional service and support to help customers optimize their applications. 2

A New Family of Power Analyzers LMG600 Multi-phase Precision Power Analyzers LMG640 /LMG610 Up to 1000V direct in 10 ranges Up to 32A direct in 14 ranges DC to 10Mhz Innovative DualPath architecture Sampling rate 1.2MS/s Modular 1-4 power channels / Single channel LMG670 Active power accuracy 0.015% rdg + 0.01% rng One power channel can be substituted with one process-signal-interface modular 3-7 power channels 3

LMG600 overview Precision power analyzer Measure View Store and Share 4

LMG600 overview Precision power analyzer Measure Capabilities Setup (configuration) Extend (CTs and PTs) 5

LMG600 overview Precision power analyzer Measure Capabilities Channels Filters DualPath Setup (configuration) Extend (CTs, PTs and PSI) 6

A/B/C-Channels 3 Types for Every Application Power analyzers are available in different accuracy classes, to allow the user to choose the right tool for the job at hand. After all, not all applications require maximum precision; often lower resolution and frequency range are sufficient. This is why the LMG600 series offers three different channel types, which can be combined in the same chassis without problems to ensure that you always have a measuring device tailored to your needs. Accuracy High-precision measurements at high bandwidth 0.025 0.04 Precise measurements on 50Hz applications Cost-effective broadband measurements 0.11 10 khz 500 khz 10 MHz Bandwidth 7

Power measurement channels 8

Channels Right Type for Every Application. Save Money Example: Electric Drive System 2-4 AC DC DC AC M C-channel A/B-channel A/B-channel 1) 2) 3) 1) Input of the converter: C1-channels are usually sufficient for this. 2) DC intermediate circuit: depending on the required level of precision, A1 or B1-channels are required, as the DC intermediate circuit exhibits significant residual ripple under certain circumstances. 3) Converter output: depending on the required level of precision, A1 or B1-channels only are to be used. 9

Filters. Accuracy without compromise In this menu the filters and wirings can be set. For several signals, it is necessary to fit filters or change the signal coupling/wiring to get the right values. You can adjust this settings separately for each group. You can select Single Path or Dual Path signal processing 10

DualPath Twice the Results, Half the Time Scope display of the voltages at the converter output. The wideband values ( ) show the PWM signal. The narrowband values ( ) are sinusoidal. 11

DualPath Twice the Results, Half the Time Simultaneous measurement in two bandwidths DualPath - No compromises, No doubt The LMG670 was the first power analyzer to have two A/D converters in two independent signal paths for each current and voltage channel. One for the filterless measurement of the wideband signal, and a second for the narrowband signal at the output of the anti-aliasing filter. The parallel processing of the digitized sample values gives the user access to both measurements of the same signal, without risking aliasing effects. This unique procedure has established itself for the complete LMG600 series. It avoids all of the downsides of previous approaches and guarantees the most precise result in the shortest time possible. The LMG600 series power analyzers get all necessary values in one shot. Fast. Reliable. No hassle. No compromises. No redundant work. 12

LMG600 overview Precision power analyzer Measure Capabilities Setup (configuration) Groups Sync Wiring Extend (CTs and PTs) 13

Group menu In this menu the filters and wirings can be set. For several signals, it is necessary to fit filters or change the signal coupling/wiring to get the right values. You can adjust this settings separately for each group. You can select Single Path or Dual Path signal processing 14

Channel menu Set up the measuring ranges. Select voltage and/or current input (direct or sensor input) and set up the ranges manually or automatically. 15

Measuring: 14 Current Ranges, 5 internal shunts Normal Current Measuring Ranges Direct Input 5 ma 10 ma 20 ma 40 ma 80 ma 150 ma 300 ma 600 ma 1.2 A 2.5 A 5 A 10 A 20 A 32 A 16

LMG600 overview Precision power analyzer Measure Capabilities Setup (configuration) Extend CTs PTs Other Signal I/F 17

Sensors: Wideband PT, Precision Current Transducers Precision high voltage divider HST for 3/6/9/12/30kV up to 300kHz, 0.05%. Negligible phase error, therefore best suited for wideband power measuring. Up to 20kV and 10kA DC/AC rms with best accuracy. Plug-and-Measure easy pre-configuration. Precise current transducers Prec. AC current transformer Clamp-on current sensor Prec. wideband current transformer Hall effect current sensors 18

Rear side interfaces: PSI Process-signal-interface: *occupies 1 slot otherwise available for 1 power measurement channel 8 digital inputs, 8 digital outputs, 2 fast analog inputs (150 ks/s, 15 khz bandwidth), 8 slow analog inputs (DC), 32 analog outputs, 2 frequency inputs (frequency, orientation, position; TTL, HTL or differential) 19

Application: Motor & Drive Total System Efficiency Components of the power measurement application with LMG670 1-or 3-phase source Frequency inverter Torque and speed sensory Motor Brake Power analyzer LMG670 20

LMG600 overview Precision power analyzer Measure View Stock Screens Custom Screens LMG Remote Store and Share 21

Default Screens In this screen all important values of the measured system can be read. Use the touch screen or soft keys to select few or manyvalues as well as the channel/s. Furthermore you can choose between measure values and harmonic analysis via soft key Display 22

Voltage and Current Screen In the Currentand Voltagescreen all important values of the current or voltage measurements can be read. You can also select between Normaland Harmonic display. 23

Power Screen In the Power screen all important values of the power measurements can be read. You can also select between Normaland Harmonicdisplay as well as many values 24

Energy Screen In the Energy screen all important values of the energy measurements can be read. Start, Stop and/or Reset your energy measurement. All channels can be started and stopped independently from each other. 25

Graph screens: Plot, Scope, Harmonics, Vector Up to 8 tracks can be graphically represented in one scope. In DualPathmode you can track narrow-and wideband signals simultaneously. Cursors can be used to obtain values at and between cursors. In Plottab you can plot measuring values. 26

LMG600 overview Precision power analyzer Measure View Stock Screens Custom Screens LMG Remote Store and Share 27

Customize a Screen Enter CUSTOM menu Pre-defined views for introduction and measuring examples. Use the first two views Introduction 1/2 and Introduction 2/2 to get a first impression. There are two basic editors: Tap shortto enter the content editor: show the grid, create boxes and add content Tap longto enter the layout editor: modify the layout, move/remove and/or resize boxes 28

Customize a Screen Enter View 6 Use the empty view to customize your own menu. First you will see soft keys to clear/load/save menus and/or to set the grid/background Now we want to build a custom menu step by step to display the power and efficiency of a variable frequency drive. First, enter the settings as marked to set the grid dimensions. 29

Customize a Screen Settings Set the grid dimensions as required. This can be specified by the required solution for the layout or the required number of parameters etc. Enter 12 rows and 24 columns. You will see the grid dimension inthe preview. 30

Customize a Screen Rename Give your own menu a name by pressing the soft key Rename. Enter a name for your custom menu. 31

Customize a Screen Set the title Enter the content editor to see the grid. Tap longer on the marked box to enter the layout editor. The box will be framed in red. Tap and hold one corner of the red framed box to resize it. Resize it as shown in the left lower screenshot. 32

Customize a Screen Set the title for the menu Leave the layout editor and to re-enter the content editor. Mark the resized box and press the soft key Add Textas marked in the screenshot. *A text in the custom menu can consist of standard html-notations. 33

Customize a Screen Complete the custom menu Add all the remaining graphs and subtitles as shown in the screenshot to your custom menu. To add graphs repeat the procedure as for adding measurands but select Add Graph instead in the content menu. In the content editor the scope source can be selected as well. The signals shown in the graphs need to be set in the GRAPH menu first. 34

LMG600 overview Precision power analyzer Measure View Stock Screens Custom Screens LMG Remote Store and Share 35

LMG Remote Benefits Control the LMG670 remotely from a Windows PC LMG Remote mimics the power analyzer itself down to the last detail Familiar operation of the measuring device from the PC Real-time display of all device functions Measuring device LMG670 Software on Windows PC 36

LMG Remote Storage menu stead of storing the measurement data (.zlr-file,.csv-file) on the device integrated HDD, LMG Remote allows the customer to store the files directly on the HDD of your Windows PC. 37

LMG Remote Interface settings on LMG670 Easy setup of the interface settings Set address masks as given from your administrator or select "DHCP on 38

LMG Remote Connection with LMG Remote Just type the IP-address of the measuring device and press Enter. Afterwards, you can start with your remote configuration and measurement. 39

LMG600 overview Precision power analyzer Measure View Store and Share Logging Networks Script Editor 40

LMG600 Data Storage - Create ZLR-file nter the Storage -menu and click enter File in the Log -card 41

LMG600 Data Storage - Create ZLR-file elect the storage location for the.zlr-file. Name the file and press Enter to get back to the Storage menu. 42

LMG600 Data Storage - Create ZLR-file ress Configure Values to select the single measurement values you want to store. You can also select the range in list-values like harmonics e.g. Press enter to get back in the menu. 43

LMG600 Data Storage - Create ZLR-file Press Create to start/stop continuous storage (one row per cycle) or press Once for single shots. 44

LMG600 Data Storage - Export CSV-file Press Export to enter the Export menu. You can add some or all stored valuesfor export. 45

LMG600 Data Storage - Export CSV-file ou can split the output file by file size or by the number of rows in each file etc. ress Enter for selecting the storage location. 46

LMG600 Data Storage - Export CSV-file Name the.csv-file and press Enter. Now you have exported your stored measurement data. 47

LMG600 overview Precision power analyzer Store and Share Logging Networks Gbit Ethernet USB storage Serial RS232 CAN Script Editor 48

LMG600 overview Precision power analyzer Measure View Store and Share Logging Networks Script Editor 49

Script Editor Powerful programming script environment for application computing on board. Full access to system information Create variables and equations for I/O control, Pass/Fail, reporting etc. 50

LMG600 overview Precision power analyzer Measure View Store and Share Harmonic and Flicker Compliance Testing 51

LMG600 with LMG Test Suite Measurement assembly according to EN61000-3 with LMG670 G ~ A G ~ A G ~ A EUT V V V AC source grid impedance NI2415-3 power analyzer LMG670 device under test 52

LMG600 with LMG Test Suite CE-Compliance The use of power electronics devices causes power or rather current depending noise on the grid or your network, which reduces the quality of your gridvoltage or interferes other connected devices. Therefore, electrical installations, systems and equipment must comply with the EU directives and regulations, when they are placed on the market within the EU. Other guidelines for electromagnetic compatibility and eco-design of energy-using products must be observed and fulfilled as well. 53

LMG600 with LMG Test Suite LMG Test Suite Only 4 steps for complete compliance test including result Setup File Test Report 54

LMG600 Series Key Features Harmonics Process Signals Custom menu Script Editor Flexible Filters Plug n Measure Synchronization With Interharmonics up to 400th order according EN61000-4-7 Torque/speed inputs fast & synchronous to rms power values Customize your own menu according your demands Convenient calculation of all derived variables Freely configurable in frequency, type and characteristics Adding sensors fast & conveniently while avoiding mistakes Up to 4 respectively 7 frequencies concurrently 55

LMG600 Series Key Features Flicker Sample Values Touchscreen Remote Control Memory Interfaces Interactions between grid and consumers acc. to EN61000-4-15 Hi-res sample values via interface Large 1024x600 display; rapid access to all important menu items Real-time display of all device functions via remote operation Internal storage even of long-term measurements Connectivity with GBit-Ethernet, USB2.0, RS-232 and DVI/VGA 56

Thank you for your attention! Questions? Robert Emerson ZES ZIMMER Inc. Sales and Application +1 760-550-9371 www.zes.com 57