Academic and Research Staff. Prof. John G. King Dr. John W. Coleman Dr. Edward H. Jacobsen. Norman D. Wittels

Similar documents
CHAPTER 4 OSCILLOSCOPES

INSTRUMENT CATHODE-RAY TUBE

2.2. VIDEO DISPLAY DEVICES

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

Teltron Delection Tube D

1. Check the accelerating voltage, must be at 200 kv (right screen), HT (µa) (left panel) at and Emission (left panel) at

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, CATHODE RAY TYPE 7AGP19

INSTRUMENT CATHODE-RAY TUBE

Understanding & Optimising Scanning Electron Microscope Performance

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

Quality produced by means of electron beam

Computer Graphics : Unit - I

IMPROVEMENTS IN LOW POWER, END-WINDOW, TRANSMISSION-TARGET X-RAY TUBES

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

The field cage for a large TPC prototype

CATHODE RAY OSCILLOSCOPE (CRO)

TOSHIBA Industrial Magnetron E3328

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

Elements of a Television System

In the tube collection there are several sensors designed for applications in some kinds of physics measurements or detection.

THE OPERATION OF A CATHODE RAY TUBE

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

Computer Graphics: Overview of Graphics Systems

The Cathode Ray Tube

2x1 prototype plasma-electrode Pockels cell (PEPC) for the National Ignition Facility

Display Systems. Viewing Images Rochester Institute of Technology

Screen investigations for low energetic electron beams at PITZ

LITE-ON TECHNOLOGY CORPORATION

JEM 3010 Manual (2011 Edition)

Filament Series Flexible Filament

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

THE OPERATION OF A CATHODE RAY TUBE

Instruments for Surface Science

RADIOGRAPHIC PERFORMANCE OF CYGNUS 1 AND THE FEBETRON 705

ET-5050x-BF1W Datasheet

B. TECH. VI SEM. I MID TERM EXAMINATION 2018

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

Types of CRT Display Devices. DVST-Direct View Storage Tube

3B SCIENTIFIC PHYSICS

Recent ITER-Relevant Gyrotron Tests

Focused Ion Beam System MI4050

Flash Single Color Datasheet

e-vap 3kW Evaporation Sources

These are used for producing a narrow and sharply focus beam of electrons.

Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS Effective Date: 10/06/2012 LITE-ON DCC RELEASE

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

CPI Gyrotrons For Fusion EC Heating

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

Particle-in-cell simulation study of PCE-gun for different hollow cathode aperture sizes

CHECKLIST FOR VERIOS OPERATION 1. GENERAL The SEM lab is used assuming "operating room" cleanliness, i.e., the SEM lab is a high visibility lab and

X-ray Tube Housing Assembly H1076X H1076Y Print No.HA Release Date:

L14 - Video. L14: Spring 2005 Introductory Digital Systems Laboratory

SE-SMD0603-PW65 SMD 0603 purweiss, wasserklar

INCA ENERGY EDS TRAINING. System Block Diagram. INCA Energy Software. Xiang Yang EM SMU. Navigators. Point & ID Navigator.

PLCC W 6000K Series Datasheet

Effect on Beam Current on varying the parameters of BFE and Control Anode of a TWT Electron Gun

CATHODE-RAY OSCILLOSCOPE (CRO)

Selection Criteria for X-ray Inspection Systems for BGA and CSP Solder Joint Analysis

ISOMET. Compensation look-up-table (LUT) and How to Generate. Isomet: Contents:

Characterizing the Electro-Optic Properties of a Microfabricated Mass Spectrometer

J.J. Thomson, Cathode Rays and the Electron

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

Brief Description of Circuit Functions. The brief ckt. description of V20 107E5 17 Monitor

Linear Probe Encoder Page 1 of 7. Description. Features

Mechanical aspects, FEA validation and geometry optimization

THE DIGITAL FLAT-PANEL X-RAY DETECTORS

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications

PLCC W 2 Series IEC White Datasheet

PLCC 5630B 0.5W High CRI Datasheet

PLCC W LC CRI80 Datasheet

JEM 2100 Manual. Operation and Basic Alignment Instructions. Check the vacuum levels (power supply closet) Column (blue scale): < 2.

PRODUCT GUIDE CEL5500 LIGHT ENGINE. World Leader in DLP Light Exploration. A TyRex Technology Family Company

THERMIONIC GUN CATHODE-GRID ASSEMBLY TEST PROCEDURE

3B SCIENTIFIC PHYSICS

E2V Technologies CX2668A, CX2668AX Air-Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

Brown, A., Merkert, J., & Wilson, R. (2014). Build your own particle accelerator. Science in School, (30),

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

PLCC Series 2835 SE PCT

Surface Analysis and Computer Technology. Optics and Power Supplies. ErLEED. User Manual 1.2

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

CHAPTER 4: HIGH ENERGY X-RAY GENERATORS: LINEAR ACCELERATORS. Jason Matney, MS, PhD

These tests will be repeated for different anode positions. Radiofrequency interaction measurements will be made subsequently. A.

PLCC Series 5630B HE High CRI

arxiv:hep-ex/ v1 27 Nov 2003

Through Hole Lamp Product Data Sheet LTW-42NDP4-HF Spec No.: DS Effective Date: 08/23/2011 LITE-ON DCC RELEASE

3528 1W 2 Series White (IP)

Modulation transfer function of a liquid crystal spatial light modulator

Reading. Displays and framebuffers. Modern graphics systems. History. Required. Angel, section 1.2, chapter 2 through 2.5. Related

Through Hole Lamp Product Data Sheet LTW-1KHDS5Z Spec No.: DS Effective Date: 10/19/2012 LITE-ON DCC RELEASE

CX1725W Liquid Cooled, Hollow Anode Two-Gap Metal/Ceramic Thyratron

Physics Requirements for the CXI Ion Time-of-Flight

PLCC Series W. Datasheet. Introduction : Feature and Benefits : Description : PLCC Series

3528 1W 3 Series White

INSTALLATION STATUS OF THE ELECTRON BEAM PROFILER FOR THE FERMILAB MAIN INJECTOR*

PLCC W CRI K Datasheet

Features 1.0 MIN. CATHODE LEAD. Sq Typ 0.50 ±0.10

Improvements in Gridless Ion Source Performance

IMPROVEMENTS IN THE CONSTRUCTION OF CATHODE.RAY TUBES

Transcription:

II. ELECTRON OPTICS Academic and Research Staff Prof. John G. King Dr. John W. Coleman Dr. Edward H. Jacobsen Graduate Students H. Frederick Dylla Bruce R. Silver Michael R. Graham Norman D. Wittels A. MODULAR PROGRAMMABLE ELECTRON BEAM SYSTEM FOR SPOT IRRADIATION IN SURFACE RESEARCH Joint Services Electronics Program (Contract DAAB07-74-C-0630) John W. Coleman, H. Frederick Dylla, Bruce R. Silver 1. Introduction The reasons for developing a modular programmable electron beam system for spot irradiation in surface research have been set forth by King and Weaver.1 The main reason is that the possibility exists for high-specificity binding sites for molecules, and thus it should be possible to stain cold surfaces with neutral molecules and then desorb the bound stain molecules with short pulses of highly localized heat or desorb them directly by electron stimulated desorption (ESD). 2 Broadly stated, the design goal is to maximize the current density that is available over a large range of voltage in a small scannable spot. Silver (see Sec. I-B) has calculated the dissipated energy density necessary to desorb small neutral atoms and molecules from biological material. The current density required in the probe is a strong function of the spot diameter because of thermal conduction in the specimen. For a 3 pm spot diameter at 10 kv, 0. 3 A/cm 2 is sufficient to desorb weakly bound molecules; in a 500 A spot, 500 A/cm 2 is needed. These values were recognized as being within the performance specifications for commercially available scanning electron microscope (SEM) systems, but because of the need for several such SEM systems to be used as blocks in larger research systems in our laboratory, the cost of buying and modifying commercial SEM equipment was prohibitive. The decision was thus made to design and build in-house the simplest possible modular system to do the required jobs. The resultant system is all-electrostatic and capable of forming spots down to a 3-pm diameter at working distances of a few centimeters. The instrument is now being used to desorb neutrals with the programmable spot. Operation of the electron beam system in a low-voltage mode for low-energy electron surface studies is also possible. A 1. 5 kv, 3 pm beam with a spot size of

(II. ELECTRON OPTICS) approximately 25 jim (formed without lens apertures) has been used in the scanning mode to obtain scanning desorption micrographs and scanning Auger micrographs of the surfaces of silicon crystals. In a nonscanning mode the beam is being used for selectedarea surface analysis by measurement of Auger electron spectra, electron energy-loss spectra, and ESD phenomena. This application is described in the report by H. F. Dylla (Sec. I-A) on the scanning desorption molecule microscope (SDMM). 2. General Design Aspects To be compatible with other building-block apparatus in our laboratory, such as ionizers, detectors, manipulators, etc., it was necessary to specify that the output end of the electron beam system fit into a cylindrical volume 4" diam (max) and 5" high (max) with focused spot position approximately 2" beyond the final deflector set. Furthermore, it was necessary to devise a universal flange not only to support the electron beam modular system in a horizontal or vertical position and provide for vacuum sealing but also to allow electrical feedthrough and shielding facilities. These considerations, as well as the overriding necessities of flexibility in use and operator safety, fairly well circumscribed the mechanical design. The electron optical design was based upon the need to control both spot size and electron flux over a wide range, and to program movement for the spot. To keep the system simple, we decided to have only two modules: an electron source module, and an electron control module. Figure II-1 summarizes the general design aspects. 3. Electron Source Module The electron source module is an electron gun designed to use either a thermionic V-filament or a Schottky thermionic field-enhanced (TF) point emitter. The advantages of the point emitter over the V-filament are decreased source size and increased maximum cathode current density, both by a factor of five to ten (see Dylla, Sec. I-A). The disadvantages of the point emitter over the V-filament are in the mechanical problems of fabrication, cathode-anode spacing, and alignment onto the axis of an optical system. With either a V- or a point filament, a choice of grid caps is available. The telefocus grid cap 3 requires only one bias potential (negative) relative to the cathode and is useful primarily for selecting an axial crossover for the primary electron beam when current into the crossover is of secondary interest to the position of crossover. The telefocus grid cap is thus of most use when the electron source module is to be used alone, e. g., to deliver a stationary collimated flood beam onto a relatively large specimen. The Braucks grid cap 4 requires two bias potentials (one positive, one negative) with

UNIVERSAL FLANGE Fig. II-1. Modular programmable electron beam system for spot irradiation in surface research, showing the assembly for double deflection SEM operation. ELECTRICAL CONNECTOR SPRING Fig. II-2. Electron source module with TF point and Braucks cap.

(II. ELECTRON OPTICS) respect to the cathode and allows control of the intensity in the directed beam and of the position of the crossover. In general, within the design parameters, an increase in the negative bias HVW causes a decrease in spot size, while an increase in the positive bias HVU causes an increase in spot current density. The Braucks cap is primarily of use when the beam is to be acted upon by one or more control modules. Figure II-2 shows the electron source module equipped with a TF point and a Braucks cap. The anode and gun-deflector set are invariant parts of the electron source module. 4. Electron Control Module The electron control module is a unitary lens + deflector package (Fig. 11-3). Its design was derived by requiring that within the mechanical limitations described here, the identical control module should be usable singly (as an objective lens) or doubly (as a condenser + objective electron optical column). Flanked on one side by a single deflector set and on the other by a double deflector set, the lens is a fully symmetric VACUUM FEEDTHROUGH ELECTRICAL CONNECTOR SPRING Fig. 11-3. Electron control module. electrostatic Einzel type, designed optimized at the following specifications: Type: electrostatic Einzel, fully Focal length: 5. 33 cm Throw from objective mid-plane: Working distance: 5 cm nominal symmetric 9 cm (max)

TF SOURCE HVW (NEGATIVE BIAS a NEGATIVE HIGH VOLTAGE) HVU (POSITIVE BIAS) ANODE GUN DEFLECTORS (X) (BEAM ALLIGNMENT) GUN DEFLECTORS (Y) (BEAM ALLIGNMENT) FLANGE BEAM PASSAGE _L_ 89cm LIMITING APERTURE PULSE DEFLECTOR (BEAM-BLANKING) APPARENT SOURCE SPRAY APERTURE CONDENSER (HVW) CONDENSER fcon 533cm MAGNIFICATION - -- co 0.015 1lO mcon= 015 89cm 8.9 CM INTERMEDIATE IMAGE CONDENSER DEF (X) (BEAM PROGRAMMING) CONDENSER DE F(Y) (BEAM PROGRAMMING) FLANGE BEAM PASSAGE OBJECTIVE DEF(X) (BEAM PROGRAMMING) 8.9 cm OBJECTIVE DEFR (Y) (BEAM PROGRAMMING OBJECTIVE MAGNIFICATION mob, 0.750 OBJECTIVE (HVW) fb 5.33cm SYSTEM DEF. (X) (BEAM ALIGNMENT) S SYSTEM DEF(Y) (BEAM ALIGNMENT) RASTER OVERALL 8.9 cm MAGNIFICATION SPECIMEN M 0.011 RAY DIAGRAM Fig. II-4. Use of the modular. programmable electron beam system in the SEM mode. One TF point electron source module is used with 2 electron control modules back-to-back. Control modules operate at HVW potential on the lens.

(II. ELECTRON OPTICS) Relative spherical aberration: 3. 5 (Cs/f) Relative chromatic aberration: 2. 5 (Cc/f) The aberration coefficients, C s and C c, are minimal for this type of lens. 5 5. Programmable Beam System Use Depending upon their assembly, the electron control module and the electron source module allow 12 possible systems ranging from a naked fixed-beam gun to a scanning electron microscope (SEM) system made up of gun, condenser lens, objective lens, and 5 sets of deflectors. In the SEM system, two-dimensional double deflection is possible, which allows raster formation at the specimen with minimum distortion in the spot because the beam itself always passes through the center of the lens used as the objective (Fig. II-4). Telecentric stops and other apertures may be placed in the system as shown. In one version of the scanning desorption molecule microscope, the programmable beam system for spot irradiation is used to heat a microvolume of biological material and evaporate sodium and potassium, which are ionized and detected. In these experiments, the sample is mounted on a thick (25 im) platinum ribbon so that no beam current is transmitted. SEM images using either absorbed or backscattered current are routinely used to position and tune up the beam. This will be described more fully in the doctoral thesis research of B. R. Silver. For these experiments, a useful beam has been obtained between 4 kv and 10 kv, with currents of 0. 1-1.0 A into a spot of (a) (b) Fig. 11-5. SEM image of platinum ribbon (lmm wide) behind a woven tungsten grid. (a) Current absorbed in ribbon. (b) Backscattered current.

(II. ELECTRON OPTICS) approximately 3 pm, the design value. The spot diameter is estimated from the image of a woven tungsten grid. Typical operating values are HVW 6.0 kv, filament current 2.2 A, bias resistor 3 MQ, HVU 170 V, dc deflection for gun alignment < ±50 V, absorbed current in specimen 0.5 pa, spot diameter = 3 p.m. Starting from any given setting for 3-pm resolution, the specimen current in general may be increased by decreasing the bias resistor, increasing HVU, or adjusting gun alignment, if the resulting broader spot is acceptable. A typical SEM image is shown in Fig. 11-5. References 1. J. G. King and J. C. Weaver, in H. E. Stanley (Ed.), Biomedical Physics and Biomaterials Science (The M. I. T. Press, Cambridge, Mass., 1972), p. 103. 2. H. F. Dylla, Quarterly Progress Report No. 110, Research Laboratory of Electronics, M.I.T., July 15, 1973, p. 1. 3. J. W. Coleman, Scientific Instruments News, RCA 5, No. 3, December 1960, p. 1. 4. F. W. Braucks, Optik 16, 304 (1959). 5. G. D. Archard, Brit. J. Appl. Phys. 7, 330 (1956).