Item no. 99904840 Connector type F-56-ALM 4,9/8,4 For cable Draka Coax10 AD 10 S (@10 C increase) Cabledata <2 mω/m @ 5-30MHz <0,1 mω/item @ 5-30MHz Shielding Effectiveness(CoMeT) 128 db @ 30-862MHz 0.3-500 MHz -35 db -37,3 db 0.3-500 MHz -0,06 db -0,01 db 500-860 MHz -30 db -32,4 db 500-860 MHz -0,07 db -0,02 db 860-1000 MHz -28 db -30,9 db 860-1000 MHz -0,07 db -0,02 db 1000-1750 MHz -23 db -25,6 db 1000-1750 MHz -0,08 db -0,03 db 1750-2150 MHz -21 db -23,8 db 1750-2150 MHz -0,09 db -0,04 db 2150-3000 MHz -20 db -22,2 db 2150-3000 MHz -0,11 db -0,06 db Installing -5 to +50 C 3rd Order (@2x100mW) 140 dbc 90 dbm Resistance (@ 1 A DC) Cabledata Overall 230 N Base Material DC Test Voltage Cabledata Test performed by Florian Lütscher Date of release February 02, 2005 C:\temp\notesC8387A\99904840.doc Form 041 rev 1
Item no. 99909441 Connector type F-56-CX3 4,9 For cable DRAKA COAX10 AD 10 S (@10 C increase) Cabledata <3 mω/m @ 5-30MHz <0,1 mω/con. @ 5-30MHz Shielding Effectiveness(CoMeT) 110 db @ 30-862MHz 0.3-500 MHz -38 db -41,0 db 0.3-500 MHz -0,06 db -0,01 db 500-860 MHz -37 db -39,1 db 500-860 MHz -0,06 db -0,01 db 860-1000 MHz -37 db -39,1 db 860-1000 MHz -0,06 db -0,01 db 1000-1750 MHz -37 db -39,1 db 1000-1750 MHz -0,07 db -0,02 db 1750-2150 MHz -31 db -33,8 db 1750-2150 MHz -0,07 db -0,02 db 2150-3000 MHz -21 db -24,1 db 2150-3000 MHz -0,08 db -0,03 db Installing -5 to +50 C 3rd Order (@2x100mW) 140 dbc 90 dbm Sealing Test (IEC IP-code) IP X8 30 meter / 8 hours Resistance (@ 1 A DC) Cabledata Overall 250 N Base Material DC Test Voltage Cabledata O-rings EPDM Test performed by Jan M. Clausen Insulators POM (Delrin) Date of release February 01, 2005 C:\temp\notesC8387A\99909441.doc Form 041 rev 1
Item no. 99901410 Connector type F-56-ALM 4,9/8,4 For cable Draka Coax10 AD 10 S Shielding Effectiveness(CoMeT) Cabledata <3 mω/m @ 5-30MHz <0,1 mω/item @ 5-30MHz >120 db @ 30-862MHz (RF Analyzer HP 8753C) Better than Typical Better than Typical 0.3-500 MHz -40 db -43,8 db 0.3-500 MHz -0,05 db -0,01 db 500-860 MHz -36 db -39,7 db 500-860 MHz -0,05 db -0,01 db 860-1000 MHz -35 db -38,4 db 860-1000 MHz -0,05 db -0,01 db 1000-1750 MHz -29 db -32,2 db 1000-1750 MHz -0,05 db -0,01 db 1750-2150 MHz -27 db -30,0 db 1750-2150 MHz -0,05 db -0,01 db 2150-3000 MHz -23 db -25,8 db 2150-3000 MHz -0,05 db -0,01 db Installing -5 to +50 C 3rd Order Product(@2x 100mW) 140 dbc 90 dbm Resistance max. @ 1 A DC Cabledata Overall 200 N Base Material Inner AC Test Voltage Cabledata Inner Test performed by Florian Lütscher Date of release August 27, 2004 C:\temp\notesC8387A\99901410.doc Form 041 rev 0
Item no. 99905140 Connector type F-56-UNIV 4,9/8,4 STANDARD ITEM For cable Draka Coax10 AD 10 S Shielding Effectiveness(CoMeT) Cabledata <3 mω/m @ 5-30MHz <0,1 mω/item @ 5-30MHz >120 db @ 30-862MHz 0.3-500 MHz -39 db -42,0 db 0.3-500 MHz -0,06 db -0,01 db 500-860 MHz -35 db -38,3 db 500-860 MHz -0,06 db -0,01 db 860-1000 MHz -33 db -36,6 db 860-1000 MHz -0,06 db -0,01 db 1000-1750 MHz -28 db -31,6 db 1000-1750 MHz -0,07 db -0,02 db 1750-2150 MHz -27 db -29,7 db 1750-2150 MHz -0,07 db -0,02 db 2150-3000 MHz -22 db -25,6 db 2150-3000 MHz -0,08 db -0,03 db Installing -5 to +50 C 3rd Order Product(@2x 100mW) 140 dbc 90 dbm Resistance max. @ 1 A DC Cabledata Overall 250 N Base Material Inner DC Test Voltage Cabledata Inner Test performed by Florian Lütscher Date of release October 06, 2004 C:\temp\notesC8387A\~0938207.doc Form 041 rev 0
Item no. 99909306 Connector type GF-UE-6 Ultra Ease For cable Draka Coax 10 AD 10 S FRNC-C Shielding Effectiveness (CoMeT) 6 A <1,3 mω/m @ 5-30MHz 0,05 mω/con. @ 5-30MHz 130 db @ 30-862MHz 0.3-500 MHz -38 db -40,5 db 0.3-500 MHz -0,06 db -0,01 db 500-860 MHz -33 db -36,1 db 500-860 MHz -0,06 db -0,01 db 860-1000 MHz -32 db -34,8 db 860-1000 MHz -0,06 db -0,01 db 1000-1750 MHz -26 db -28,8 db 1000-1750 MHz -0,06 db -0,01 db 1750-2150 MHz -24 db -26,2 db 1750-2150 MHz -0,07 db -0,02 db 2150-3000 MHz -20 db -23,7 db 2150-3000 MHz -0,07 db -0,02 db Installing -5 to +50 C 3rd Order Product(@2x 100mW) 147 dbc 93 dbm Sealing Test (IEC IP-code) see remarks Resistance max. @ 1 A DC Cabledata Overall 270 N Base Material Body Parts C36000 Brass Alloy Inner Dielectric Strength Body Parts Nickel / Bright Acid Tin AC Test Voltage 3 KV Inner Test performed by Jan M. Clausen Insulators POM Date of release May 24, 2004 1meter / 24 hours with G-SR-1/2 SEAL RING 99900900 O:\Mm\Draka\Datablade\Coax 10 AD 10 S FRNC-C\99909306.doc Rev. 020403
Item no. 99909484-01 Connector type IECM-56-CX3 4,9 For cable Draka Coax 10 AD 10 S Shielding Effectiveness (CoMeT) 3 A 7,2 mω/m @ 5-30MHz 0,2 mω/con. @ 5-30MHz 98 db @ 30-862MHz (RF Analyzer HP 8719D / 8714C) Better than Typical Better than Typical 0.3-500 MHz -25 db -28,5 db 0.3-500 MHz -0,15 db -0,10 db 500-860 MHz -20 db -23,3 db 500-860 MHz -0,20 db -0,15 db 860-1000 MHz -19 db -22,1 db 860-1000 MHz -0,21 db -0,16 db 1000-1750 MHz -17 db -19,8 db 1000-1750 MHz -0,33 db -0,28 db 1750-2150 MHz -15 db -18,2 db 1750-2150 MHz -0,43 db -0,38 db 2150-3000 MHz -11 db -14,1 db 2150-3000 MHz -0,70 db -0,65 db Installing -5 to +50 C 3rd Order Product (2x100mW) 140 dbc +90 dbm (@ 500 V) >200 GΩ Sealing Test see remarks Resistance max. @ 1 A DC 1,2 mω Overall 275 N Base Material Inner Brass CuZn39Pb3 / Beryllium copper AC Test Voltage 2,0 KV Inner Nitin-6 Test performed by Jan M. Clausen Insulators Delrin Date of release January 14, 2005 Water tightness and better Screening results can be achieved with accessory 99900569 or 99900570-01, which contains nut and O-ring. Datasheet with this combination is available on request. ISO 9001 certified O:\TestAfd\DATABLAD\Nye\Draka\Coax10 AD 10 S\99909484-01.doc Rev. 020403
Item no. 99909494 Connector type IECF-56-CX3 4,9 For cable Draka Coax 10 AD 10 S Shielding Effectiveness (CoMeT) 3 A 6,0 mω/m @ 5-30MHz 0,2 mω/con. @ 5-30MHz 93 db @ 30-862MHz (RF Analyzer HP 8719D / 8714C) Better than Typical Better than Typical 0.3-500 MHz -22,5 db -24,9 db 0.3-500 MHz -0,10 db 0,05 db 500-860 MHz -18,0 db -20,3 db 500-860 MHz -0,13 db 0,08 db 860-1000 MHz -17,0 db -19,5 db 860-1000 MHz -0,15 db 0,10 db 1000-1750 MHz -13,5 db -15,7 db 1000-1750 MHz -0,22 db 0,17 db 1750-2150 MHz -12,5 db -14,7 db 1750-2150 MHz -0,25 db 0,20 db 2150-3000 MHz -11,0 db -13,8 db 2150-3000 MHz -0,31 db 0,26 db Installing -5 to +50 C 3rd Order Product (2x100mW) 110 dbc +75 dbm (@ 500 V) >200 GΩ Resistance max. @ 1 A DC 2,7 mω Overall 275 N Base Material Inner Tin Bronze / Beryllium copper AC Test Voltage 2,0 KV Inner Nitin-6 Test performed by Troels V. Kristensen Insulators Delrin Date of release February 20, 2003 ISO 9001 certified O:\Mm\Draka\Datablade\Coax10 AD 10 S\99909494\99909494.doc Rev. 020403
Item no. 99498740 Connector type 3.5/12M-56-EPA 4,9/8,1.360" For cable Draka Coax 10AD10S Shielding Effectiveness(CoMeT) 8 A <1 mω/m @ 5-30MHz <0,1 mω/con. @ 5-30MHz >120 db @ 30-862MHz (RF Analyzer HP 8719D / 8714C) Better than Typical Better than Typical 0.3-500 MHz 37 db -40,4 db 0.3-500 MHz -0,06 db -0,02 db 500-860 MHz 35 db -37,7 db 500-860 MHz -0,06 db -0,02 db 860-1000 MHz 34 db -37,1 db 860-1000 MHz -0,07 db -0,02 db 1000-1750 MHz 32 db -34,7 db 1000-1750 MHz -0,08 db -0,03 db 1750-2150 MHz 27 db -29,5 db 1750-2150 MHz -0,08 db -0,03 db 2150-3000 MHz 20 db -22,6 db 2150-3000 MHz -0,09 db -0,04 db Installing -5 to +50 C 3rd Order Product(@2x 1W) 140 dbc 90 dbm -40 to +85 C Storing -40 to +85 C Insulation Resistance (@ 500 V) >29,99 GΩ Sealing Test (IEC IP-code) IP X7 Resistance max. @ 1 A DC 1,2 mω Overall 250 N Base Material Inner Tin Bronze AC Test Voltage 2,5 KV Inner Nitin-6 O-rings EPDM Test performed by Troels V. Kristensen Insulators PE / PP with Glass Date of release July 21, 2004 C:\temp\notesC8387A\99498740.doc Form 041 rev 0
Item no. 99909475 Connector type BNCM-56-CX3 4,9 For cable Draka Coax10 AD 10 S (@10 C increase) 3 A Shielding Effectiveness(CoMeT) 75 db @ 30-862MHz 0.3-500 MHz -38 db -40,8 db 0.3-500 MHz -0,08 db -0,03 db 500-860 MHz -33 db -36,2 db 500-860 MHz -0,09 db -0,04 db 860-1000 MHz -32 db -35,0 db 860-1000 MHz -0,10 db -0,05 db 1000-1750 MHz -22 db -24,6 db 1000-1750 MHz -0,12 db -0,07 db 1750-2150 MHz -19 db -22,0 db 1750-2150 MHz -0,14 db -0,09 db 2150-3000 MHz -18 db -21,8 db 2150-3000 MHz -0,19 db -0,14 db Temperature Installing -5 to +50 C -40 to +70 C Storing -40 to +70 C Insulation Resistance (@ 500 V) >29,99 GΩ Resistance (@ 1 A DC) 1,5 mω Overall 250 N Base Material / Copper / POM Brass CuZn39Pb3 / Beryllium copper / Nickel DC Test Voltage 3,5 KV Nitin-6 / Tin Test performed by Florian Lütscher Insulators PTFE (Teflon) / PE Date of release December 17, 2004 O:\TestAfd\DATABLAD\CX3\Draka\Coax10 AD 10 S\99909475.doc Form 041 rev 1