EE201: Transmission Line Protection

Similar documents
EE028: Practical High Voltage Cable Jointing and Termination

Implementation of a High-Speed Distribution Network Reconfiguration Scheme by Greg Hataway, Ted Warren, and Chris Stephens.

RF (Wireless) Fundamentals 1- Day Seminar

Breaker-and-a-half Automatic reclosing and leader follower.

MICROMASTER Encoder Module

SIPROTEC 5 Application Note

DSIM-AF Installation Guide Revision B

Removal of Decaying DC Component in Current Signal Using a ovel Estimation Algorithm

PRE-INSTALLATION ELECTRICAL POWER GUIDE

NEW MEXICO STATE UNIVERSITY Electrical and Computer Engineering Department. EE162 Digital Circuit Design Fall Lab 5: Latches & Flip-Flops

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ECE 402L APPLICATIONS OF ANALOG INTEGRATED CIRCUITS SPRING No labs meet this week. Course introduction & lab safety

AUTOMATIC TRANSFER SWITCHES. Product Guide

Digital Logic. ECE 206, Fall 2001: Lab 1. Learning Objectives. The Logic Simulator

Fieldbus Testing with Online Physical Layer Diagnostics

Medium and High Voltage Circuit Breakers Characteristic Time Quantities of the Circuit Breaker with Applications

Automatic Transfer Switch Control PLC Operator s Manual

DSIM-GI Installation Guide Revision P

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH)

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

REFURBISHMENT OF SECONDARY SYSTEMS IN HIGH VOLTAGE SUBSTATIONS LESSONS LEARNED IN VENEZUELA

FINAL REPORT LOAD SHEDDING IN TASMANIA ON 20 DECEMBER 2016 REVIEWABLE OPERATING INCIDENT REPORT FOR THE NATIONAL ELECTRICITY MARKET

Using on-chip Test Pattern Compression for Full Scan SoC Designs

DIN Power Module - Phase Adaptive

V9A01 Solution Specification V0.1

Laboratory 1 - Introduction to Digital Electronics and Lab Equipment (Logic Analyzers, Digital Oscilloscope, and FPGA-based Labkit)

LAB 3 Verilog for Combinatorial Circuits

Toronto Hydro - Electric System

Telephony Training Systems

EG4015. Digital Generator Governor Controller User Manual

LAB 3 Verilog for Combinational Circuits

Session 1 Introduction to Data Acquisition and Real-Time Control

Benchmark and Benchmark Platinum Electrical Power Guide

COMPUTER ENGINEERING PROGRAM

The Newsletter of Delta Automation Inc.

TABLE OF CONTENTS. Instructions:

HITACHI. VisionCube. Service Manual

INSTRUCTION MANUAL AUTORECLOSING RELAY GRR100 - B

ex 800 Series ematrix System

PRINCIPLES AND APPLICATIONS

Telephony Training Systems

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

DLP600M 6+1 Relay Module for Heating and Cooling Plants

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

LABORATORY EXPERIMENTS IN DISTANCE LEARNING

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

ENGG2410: Digital Design Lab 5: Modular Designs and Hierarchy Using VHDL

FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd.

INSTRUCTION MANUAL BREAKER FAILURE RELAY GRC100

Instruction Manual. DLP-C Digital Line Protection. GE Power Management

MANAGING POWER SYSTEM FAULTS. Xianyong Feng, PhD Center for Electromechanics The University of Texas at Austin November 14, 2017

SAPLING MASTER CLOCKS

Practical Exercise Look at the circuit diagram shown. What will happen in this circuit if switch S2 is pressed momentarily?

DLP200M 2 Relay Module for Heating and Cooling Plants

Course Outline Cover Page

Mitigation of Cascading Outages and Prevention of Blackouts:System-Wide Corrective Control

TEAMS Competition 2014

MICROFOCUS X-RAY SOURCE PROJECT*

MSC+ Controller. Operation Manual

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

CITY OF LOS ANGELES CIVIL SERVICE COMMISSION CLASS SPECIFICATION POSTED JUNE VIDEO TECHNICIAN, 6145

Introduction To LabVIEW and the DSP Board

CARLETON UNIVERSITY. Facts without theory is trivia. Theory without facts is bull 2607-LRB

3200NT System 14. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Cable Broadband Premises Installation and Service

DX-10 tm Digital Interface User s Guide

Modbus for SKF IMx and Analyst

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

APPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them.

Get a 360 view on Power Supplies

LABORATORY EXPERIMENTS IN DISTANCE LEARNING

#P46. Time Domain Reflectometry. Q: What is TDR and how does it work?

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

T +31 (0) F

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

3AH3 Vacuum Circuit-Breakers

Testing Digital Systems II

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Dimming actuators GDA-4K KNX GDA-8K KNX

Previous Lecture Sequential Circuits. Slide Summary of contents covered in this lecture. (Refer Slide Time: 01:55)

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

DMC550 Technical Reference

Excel recommends Fluke Networks, this section is written around the use of this range of test equipment.

StepArray+ Self-powered digitally steerable column loudspeakers

Switching Power Module

FORENSIC CASEBOOK. By Bob Huddleston, Eastman Chemical Co. One of the most common. reasons for marriage failure

Understanding. Here s an examination of high-frequency pathological signal transmission issues in today s high-bandwidth equipment.

SAPLING WIRED SYSTEM

VLSI Test Technology and Reliability (ET4076)

Adding Analog and Mixed Signal Concerns to a Digital VLSI Course

CDP-0, CDP-G, CDP-DUO INSTRUCTION MANUAL (M B)

EC456 Power System Protection Lab #1 Overcurrent Protection Relay

BER MEASUREMENT IN THE NOISY CHANNEL

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Sentinel I24 Digital Input and Output Configuration

Integration Note. Any feature not specifically noted as supported should be assumed to be unsupported.

ELEC 310 Digital Signal Processing

Improved Synchronization System for Thermal Power Station

Transcription:

EE201: Transmission Line Protection EE201 Rev.001 CMCT COURSE OUTLINE Page 1 of 5

Training Description: Engineers and power system consultants who need a comprehensive understanding of the challenges and solutions for protecting high-voltage power transmission lines is a must attend this course. This intensive training provides an in-depth study of the methods used in designing protection systems for high-voltage power transmission lines. The course provides advanced guidelines for relay application and settings for transmission lines, including series-compensated lines. It also reviews time-domain ultra-highspeed line protection principles. The course covers the application and settings of power swing blocking and out-of-step tripping functions. Training Objective: By the end of the training, participants will be able to: Learn how to correctly configure the D60 and ALPS Distance relays the L90 line current differential and L60 LinePhase Comparison Describe the protection requirements of modern power transmission lines Identify the protection and fault location methods to apply in modern transmission lines Identify the strengths and limitations of available tools to protect transmission lines against phase-to-phase and phase-to-ground faults Define and address protection problems for high-voltage transmission lines Implement modern directional and distance elements into existing protection Select the best pilot protection schemes for transmission lines Implement directional comparison pilot and line differential protection schemes Explain the effects of reclosing (three-pole and single-pole) and breaker failure protection to preserve the stability of high-voltage transmission systems Training Designed for: This course is intended Electrical maintenance and engineering personnel who wish to gain a better understanding of Transmission Line protection and the procedures to install and configure the Transmission Line Protection Relays. Training Program: DAY ONE: PRE-TEST Introduction Transmission Line Fundamentals Relaying basics Circuit Breakers Primary and Backup relaying Introduction to Symmetrical component EE201 Rev.001 CMCT COURSE OUTLINE Page 2 of 5

Current Transformers Potential Transformers DAY TWO: Introduction to the Universal Relay Universal Relay Hardware overview o UR Modular concept o Family members o Hardware configuration Mechanical installation Options and ordering EnerVista UR Setup Software Settings o Production Setup o System Setup Commands o Virtual Inputs o Clear records o Set date and time Actual Valves o Front Panel o Status and Metering o Status and Metering Lab DAY THREE: Introduction to FlexLogic o Logic Gates Programing Flexlogic equations Oscillography and Event Log Lab Fault Diagnostic Lab Saving/loading setting files Maintenance procedures Adding/Removing modules DAY FOUR: L60/L90 Relays Grouped Elements Phase Differential protective theory Protection element calculations for a typical L60 application and demonstration Lab Line Current Differential theory Protection element calculations for a typical L90 application L90 demonstration Lab DAY FIVE: D60 ALPS Relays Introduction to Transmission Lines Distance protection theory EE201 Rev.001 CMCT COURSE OUTLINE Page 3 of 5

Stepped distance Zone I extended Pilot aided schemes: DUTT, PUTT, POTT, HYBRID POTT, Directional-blocking Power swings D60 overview Protection element calculations for a typical D60 application and demonstration Lab ALPS overview Hardware overview Mechanical overview Mechanical and wiring instructions Protection element overview Configuration software Communication testing Relay maintenance Course Conclusion POST-TEST and EVALUATION Training Requirement: Hand s on practical sessions, equipment and software will be applied during the course if required and as per the client s request. Training Methodology: This interactive training course includes the following training methodologies as a percentage of the total tuition hours:- 30% Lectures, Concepts, Role Play 30% Workshops & Work Presentations, Techniques 20% Based on Case Studies & Practical Exercises 20% Videos, Software & General Discussions Pre and Post Test Training Certificate(s): Internationally recognized certificate(s) will be issued to each participant who completed the course. Training Fees: As per the course location - This rate includes participant s manual, hand-outs, buffet lunch, coffee/tea on arrival, morning & afternoon of each day. EE201 Rev.001 CMCT COURSE OUTLINE Page 4 of 5

Training Timings: Daily Timings: 07:45-08:00 Morning Coffee / Tea 08:00-10:00 First Session 10:00-10:20 Recess (Coffee/Tea/Snacks) 10:20-12:20 Second Session 12:20-13:30 Recess (Prayer Break & Lunch) 13:30-15:00 Last Session For training registrations or in-house enquiries, please contact: Aisha Relativo: aisha@cmc-me.com Tel.: +971 2 665 3945 or +971 2 643 6653 Mob.: +971 52 2954615 Training & Career Development Department EE201 Rev.001 CMCT COURSE OUTLINE Page 5 of 5