Selected Problems of Display and Projection Color Measurement

Similar documents
DISPLAY WEEK 2015 REVIEW AND METROLOGY ISSUE

Using LightSpace CMS for User Created Calibration LUTs

Color measurement and calibration of professional display devices

KNOWLEDGE of the fundamentals of human color vision,

Issues in Color Matching Joel Barsotti, Derek Smith and L. A. Heberlein. doi: /j18278

specification display applications cronus spectrometer & colorimeter

[source unknown] Cornell CS465 Fall 2004 Lecture Steve Marschner 1

LCD and Plasma display technologies are promising solutions for large-format

Colour Matching Technology

Quato Intelli Proof Series. A comprehensive overview of the key benefits

Achieve Accurate Critical Display Performance With Professional and Consumer Level Displays

Visual Color Matching under Various Viewing Conditions

Measurement of Microdisplays at NPL

Common assumptions in color characterization of projectors

ICAC User Manual. ICAC - ( Intelligent Connection for Alignment & Calibration ) Setup Calibration Measurement USO RESTRITO. Version 14.2.

Calibration of Colour Analysers

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

Color Reproduction Complex

Using Low-Cost Plasma Displays As Reference Monitors. Peter Putman, CTS, ISF President, ROAM Consulting LLC Editor/Publisher, HDTVexpert.

Power saving in LCD panels

DCI Memorandum Regarding Direct View Displays

Murdoch redux. Colorimetry as Linear Algebra. Math of additive mixing. Approaching color mathematically. RGB colors add as vectors

DRAFT. Proposal to modify International Standard IEC

Setup Guide. Klein K-10CP Colorimeter. Rev. 1.1

specification MSE series MSE and MSE+ colorimeter

Color Reproduction Complex

Root6 Tech Breakfast July 2015 Phil Crawley

An Introduction to TrueSource

SURFACE MOUNT LED LAMP STANDARD BRIGHT PLCC-2

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

May 2014 Phil on Twitter Monitor Calibration & Colour - Introduction

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1210

Setup Guide. X-Rite i1display. Retail and OEM. Rev. 1.2

LaserPXIe Series. Tunable Laser Source PRELIMINARY SPEC SHEET

Comparison of SONY ILX511B CCD and Hamamatsu S10420 BT-CCD for VIS Spectroscopy

Remote Director and NEC LCD3090WQXi on GRACoL Coated #1

SURFACE MOUNT LED LAMP 0603 (0.8 mm Height)

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

NVLAP LAB CODE LM Test Report. For. EiKO Global, LLC. (Brand Name: EiKO) W. 84th St, Shawnee, KS USA

Setup Guide. SpectraCal C6 HDR2000 Colorimeter. Rev. 1.2

Color Nonuniformity in Projection-Based Displays: Analysis and Solutions

FSI Calibration Guide Using CR100 / LightSpace / BoxIO

BUREAU OF ENERGY EFFICIENCY

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires

User Manual OVP Raman

specification hyperion colorimeter

specification hyperion colorimeter

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

Performance Benchmarking of Wide Color Gamut Displays. 8 January 2016

User Calibration Software. CM-S20w. Instruction Manual. Make sure to read this before use.

Colorimetric Characterization of Three Computer Displays (LCD and CRT) Jason E. Gibson and Mark D. Fairchild January, 2000

SURFACE MOUNT LED LAMP FULL COLOR 1210

SURFACE MOUNT LED LAMP STANDARD BRIGHT 0606

Palette Master Color Management Software

Bringing Better Pixels to UHD with Quantum Dots

Methods for the Measurement of the performance of Studio Monitors

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

HDR & WIDE COLOR GAMUT

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1206 (Reverse Mount)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

ABSTRACT 1. INTRODUCTION 2. EXPERIMENTS. Corresponding author: +1 (518) ;

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

User requirements for a Flat Panel Display (FPD) as a Master monitor in an HDTV programme production environment. Report ITU-R BT.

Calibration Best Practices

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses. Unprecedented design freedom for solid state

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses

Presentation Monitoring Solutions. Curolux

Processing. Electrical Engineering, Department. IIT Kanpur. NPTEL Online - IIT Kanpur

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions

SpectraCal C6-HDR Technical Paper

Displays AND-TFT-5PA PRELIMINARY. 320 x 234 Pixels LCD Color Monitor. Features

Background Statement for SEMI Draft Document 5291A New Standard: TEST METHOD OF AMBIENT COLOR GAMUT FOR FPD UNDER INDOOR ENVIRONMENTS

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

Considerations for Blending LED Phosphors

High-resolution screens have become a mainstay on modern smartphones. Initial. Displays 3.1 LCD

ISO/IEC TR TECHNICAL REPORT

LCD MODULE SPECIFICATION

Background Statement for SEMI Draft Document 4759A NEW STANDARD: TEST METHOD OF PERCEPTUAL ANGLE FOR OLED DISPLAYS

Technical Developments for Widescreen LCDs, and Products Employed These Technologies

CLIPSTER. 3D LUT File Generation with the Kodak Display Manager. Supplement

Setup Guide. Color Volume Analysis Workflow. Rev. 1.2

V9A01 Solution Specification V0.1

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

Medical Imaging Working Group

User Manual February, 2011

Instruction Manual. 1 Page

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

Color Gamut Mapping based on Mahalanobis Distance for Color Reproduction of Electronic Endoscope Image under Different Illuminant

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

VeriLUM 5.2. Video Display Calibration And Conformance Tracking. IMAGE Smiths, Inc. P.O. Box 30928, Bethesda, MD USA

Understanding Human Color Vision

AND-TFT-64PA-DHB 960 x 234 Pixels LCD Color Monitor

LightLab I N T E R N A T I O N A L

ALS-PDIC17-77C/TR8. Surface - Mount Ambient Light Sensor. Features. Description. Applications

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

High-Definition, Standard-Definition Compatible Color Bar Signal

The XYZ Colour Space. 26 January 2011 WHITE PAPER. IMAGE PROCESSING TECHNIQUES

Transcription:

Application Note 27 JETI Technische Instrumente GmbH Tatzendpromenade 2 D - 07745 Jena Germany Tel. : +49 3641 225 680 Fax : +49 3641 225 681 e-mail : sales@jeti.com Internet : www.jeti.com Selected Problems of Display and Projection Color Measurement Minimum Optical Resolution of a Spectro radiometer for Laser Projection Measurement Device Comparability Color Mismatch of Monitors

Minimum Optical Resolution of a Spectro radiometer for Laser Projection Measurement The request for high resolution spectro radiometers becomes more and more popular especially due to the increased use of laser based projections. In this chapter, it will be investigated which optical resolution (FWHM) is necessary for a spectro radiometer to measure laser projection systems correctly with regard to the luminance and chromaticity. It can be distinguished between pure RGB lasers and the hybrid type with a blue laser and fluorescence material. Here the most critical case, a RGB laser projector will be investigated. First of all there will be discussed the definitions for the resolution of a spectro radiometer. There exist three different parameters with respect to the resolution which are sometimes mixed: The optical resolution, also called bandwidth or Full Width at Half Maximum (FWHM), is the real limiting resolution parameter. It describes the spectral widening of a very narrow spectral line, e.g. of a laser or a discharge lamp, caused by the optical system of the spectrograph. The digital resolution, also pixel resolution (nm/ pixel), is the spectral bandwidth which falls on one pixel of the spectrograph detector array. It should be at least 1/3 of the optical resolution, otherwise it will be the limiting factor. The calculated resolution value is the interpolated step with of the spectral calculation. Typical values used for spectro radiometers are 1 and 5 nm. 5 0% F W H M 5 28 52 9 5 3 0 5 31 53 2 8.4 8.5 / nm position on line array /mm pixel Fig. 1: Different resolution definitions of a peak Now we will consider a RGB laser projector, e.g. the NEC 1040L. Its light source is a combination of the three laser wavelengths of 460 nm (blue), 532 nm (green) and 637 nm (red). Copyright 2016 JETI Technische Instrumente GmbH 2

x Application note Selected Problems of Color Measurement The following diagrams show simulated white spectra of this projector when detected by a spectro radiometer with an optical resolution of 1, 5, 10 and 20 nm. Fig. 2: Simulated projector spectra with different optical resolution The following diagrams show the x and the y value calculated for the optical resolution of 1 to 20 nm in steps of 1 nm. It can be seen, that both chromaticity values are nearly constant or only slightly changing for an optical resolution of 1 to 4 5 nm. Hence a meter with a resolution of 4 5 nm is sufficient also for the calibration of laser projectors. But it has to be considered that there are many other influences on the measurement result which overlap this small change (see chapter 2). 0,3410 0,3400 0,3390 0,3380 0,3370 0,3360 0,3350 0,3340 0,3330 0,3320 0,3310 x (FWHM) 1 3 5 7 9 11 13 15 17 19 FWHM/ nm Fig. 3: Dependence of chromaticity x from the optical resolution (FWHM) Copyright 2016 JETI Technische Instrumente GmbH 3

y y Application note Selected Problems of Color Measurement 0,3500 y (FWHM) 0,3495 0,3490 0,3485 0,3480 0,3475 0,3470 0,3465 0,3460 1 3 5 7 9 11 13 15 17 19 FWHM/ nm Fig. 4: Dependence of chromaticity y from the optical resolution (FWHM) The following diagram shows the total xy shift of the same measurements and for the same change of the optical resolution. Chromaticity coordinates for different bandwidth 0,3500 0,3495 0,3490 0,3485 0,3480 0,3475 0,3470 123 456 7 8 9 10 11 12 13 14 15 16 17 18 19 20 0,3465 0,3460 0,3300 0,3320 0,3340 0,3360 x 0,3380 0,3400 0,3420 Fig. 5: Dependence of chromaticity xy from the optical resolution (FWHM in nm) Summarizing: It is not necessary to use a device with a higher optical resolution than 4 5 nm for this application. The same result is valid for non-laser projections and displays. Copyright 2016 JETI Technische Instrumente GmbH 4

Device Comparability There are several devices on the market for the measurement of color of self luminous objects, especially of monitors and projections. They are based either on the tristimulus technique (colorimeters) or on the spectral technique (spectro radiometers). An often discussed question is the comparability of the measuring results of different devices. It can be distinguished between two levels of comparability: between devices of the same model and between different models, especially between models of different manufacturers. The different models of one manufacturer are often calibrated in the same way and the manufacturer will take care about the comparability of his products, on one side by its measuring uncertainty calculations and on the other side by practical tests. The comparison of tristimulus and spectral measuring devices of different manufacturers can produce very different results depending from their parameters. E.g. if the deviation of the spectral responsivity of a colorimeter to the Color Matching Functions (CMF) is too high there will exist significant differences to the readings of a spectro radiometer, where the CMFs are stored in its software. The matching of the colorimeter to the spectro radiometer (profiling) will help, but only for the same shape of spectra. Additionally, it can be shown already theoretically that differences in parameters of devices of same technology will also result in different readings. Examples for such critical parameters are the optical resolution (see chapter 1) and the stray light behaviour. More influences are the status of calibration, in case of spectro radiometers for the wavelength axis as for the sensitivity axis as well. Category Examples Measuring equipment general Measuring equipment individual Individual errors Tristimulus/ Spectral Device parameters (CMF matching, Resolution, Dynamics, Straylight, Linearity,...) Calibration status of the probes (wavelength, sensitivity) Warm up time too short Ambient light (reflex) Individual sensitivity The following test is an example of comparing the measuring results of spectroradiometers (specbos 1211 (JETI), CR-250 (Colorimetry Research) and CS-2000 (Konica Minolta)), measuring a JVC LCD monitor with CCFL backlight. The diagrams show the deviations in Y, x and y of specbos 1211 and CR-250 to the readings of a CS- 2000 for different settings of the monitor: Copyright 2016 JETI Technische Instrumente GmbH 5

Fig. 6: CR-250, specbos 1211 and CS-2000 in front of an OLED monitor Fig. 7: Deviation of Lv of CR-250 and specbos 1211 readings to CS 2000 Copyright 2016 JETI Technische Instrumente GmbH 6

Fig. 8: Deviation of x (above) and y (below) of CR-250 and specbos 1211 readings to CS 2000 All three devices were properly calibrated and individual impacts were carefully avoided during the measurements. It can be seen that the deviation of x and y between the units is around 0.001 0.003 with some exceptions. For the white settings this will cause differences in CCT of 150 250 K. Copyright 2016 JETI Technische Instrumente GmbH 7

The differences in luminance readings are in the range of 1 % with two exceptions. Other comparisons during previous years show similar results. It can be summarized that the deviation of properly calibrated comparable devices are in the following ranges: up to 0.002.. 0.003 in xy therefore the differences in CCT are up to 150 K Lv in the 1... 2 % range The different readings are mainly caused by differences in o Wavelength fit o Level calibration o Spectrometer parameters (stray light, non linearity, bandwidth...) Color Mismatch of Monitors The following is an actual problem in OLED color adjustment: A precise calibration of such display can end with a slightly colored white appearance, mainly with a yellowish shade of color. A similar problem is already known for many years: Two monitors made by different display technologies might appear visually different after calibration. It is very difficult to match displays of different technologies, e.g. an LCD with LED backlight and one with CCFL backlight, to the same visual perception. Fig. 9: CCFL/ LCD (left) and Plasma monitor (right), both set to same xyy values Such problems arise due to the appearance of new display technologies during previous years. There exist two approaches to solve these problems and they will be summarized here: 1. Use other than the CIE 1931 Color Matching Functions (CMF) 2. Use an offset for the xy values The following figure shows typical white spectra of different display technologies: LCD with LED backlight Copyright 2016 JETI Technische Instrumente GmbH 8

LCD with CCFL backlight CRT OLED Fig. 10: White spectra of different displays It can be seen that there are spectra with wide peaks and spectra with wide and narrow peaks. Possible reasons of the problems are: The concept of Color Matching Functions does not simulate the human color vision correctly, e.g. the visual impression of broadband spectra is different than that of spectra with narrow band parts. The Color Matching Functions of 1931 do not correctly reproduce the human color vision. 1. New color matching functions The classical light and color measurement is based on the 2 standard observer of CIE 1931. These data are based on the measurements of two color scientists (W. David Wright and John Guild) and a very limited number of test persons. It quickly became clear that these data did not fully reproduce the visual perception of the human being. So the research on alternate functions started very soon and is continued till today. The only other standardized data are these of the 10 observer of 1964. Due to the fact that the angular subtense of a TV monitor is more close to 10 than to 2 under normal conditions these data work slightly better for the calibration than the 1931 data. Copyright 2016 JETI Technische Instrumente GmbH 9

z y x Application note Selected Problems of Color Measurement A better approach is to use the data of Judd, modified by Vos (Judd Vos CMFs). If they are appliedd they give a better visual agreement than both classical CIE data, especially when used on an OLED display. 2006/ 2015 the CIE published a new document No. 170 with a data set, which is based on the data of Stiles/ Burch (1959) with a modification by Stockman. They can be calculated for different angles between 2 and 10, but also for different observer ages. The CIE 170 data were modified afterwards by Schanda and Csuti (University of Veszprem, Hungary), they shifted values in the blue region by 6 nm. Recently Polster (TU Ilmenau, Germany) found a better agreement with human color vision for a shift of only 3 nm. Many of these data can be found here: http://www.cvrl.org One has to consider that all these data were developed based on experiments with LED illumination, but they can be used for all monitor calibrations too. The following diagrams show several CMFs, separated by x, y and z. 1,5 1 0,5 x 2 (CIE 1931) Judd-Vos 1978-2 1,5 1 0,5 0 380 430 480 530 580 630 680 730 780 Wavelength/ nm y 0 380 430 480 530 580 630 680 730 780-0,5 Wavelength/ nm Schanda/ Csuti Mod TU Ilmenau Mod 2 (CIE 1931) Judd-Vos 1978-2 Schanda/ Csuti Mod TU Ilmenau Mod 2,5 2 1,5 z 2 (CIE 1931) Judd-Vos 1978-2 1 0,5 0 380 430 480 530 580 630 680 730 780 Wavelength/ nm Schanda/ Csuti Mod TU Ilmenau Mod Fig. 11: Comparison of different Color Matching Functions Copyright 2016 JETI Technische Instrumente GmbH 10

The software JETI LiVal includes the following observer functions: Fig. 12: JETI LiVal and CalMAN Observer settings The application of a CMF changes the shape of the color diagram slightly: Fig. 13: xy color diagram based on CIE 1931 (left) and Polster (TU Ilmenau) 2 (right) Tests of several users showed the new CMFs are helpful for a better calibration of monitors, but they don t fully solve the problem. It is also not clear yet, which data are the best ones for all applications. Currently the user has to proceed his own tests. Of course the new CMFs cannot be used with colorimeters which are designed to reproduce the CIE 1931 data. But in this case approach 2 can be used. 2. Offsets for xy values This approach is easier and concerns the white and gray settings of the display only. The SMPTE document RP 2080-2:2014 recommends an offset for LED backlighted LCDs of -0.006 for x and of 0.011 for y. These values are based on tests with the Judd Vos data. For CRTs and plasma displays it is recommended to use the original CIE 1931 data. Sony recommends specific offset values for the equalization of different monitor types. The following table shows an example: Copyright 2016 JETI Technische Instrumente GmbH 11

Fig. 14: Example for offset data recommended by Sony (others are available) More information can be found here: https://pro.sony.com/bbsccms/assets/files/cat/mondisp/solutions/monitor_autowhiteadjustment_ manual.pdf The following figure shows a shifted white point for the calibration in CalMAN. Instead of the original D65 values slightly shifted xy data obtained by the Judd Vos modification can be used. Additionally, it is possible to use own xy data. Fig. 15: White point setting in CalMAN One can see that there is a multitude of possibilities and it is necessary to proceed own tests to find the best result for the application in hand. Copyright 2016 JETI Technische Instrumente GmbH 12

Sometimes it is necessary to match two displays of different technologies to the same colors. The problem of different visual color appearance arises especially when two monitors are placed side by side. If they are located at different positions it is much more difficult for the average observer to see a difference, because the eye proceeds an adaption for each viewing situation ( white balance ). The following procedure based on an xy offset was presented by Flanders Scientific: 1. Decide which of the two displays will serve as the primary reference (we will call this Monitor A). This reference device should be calibrated to a known standard. 2. Generate a flat white field test patch to both monitors. (90% white is recommended). 3. Provide a way for the color of the white field test patch to be adjusted ONLY on the secondary monitor (we will call this Monitor B). The best approach will vary depending on equipment in use, but can be as simple as adjusting RGB Gain controls on the unit. 4. Adjust Monitor B to perceptually match Monitor A on this one solid test patch. 5. After a perceptual match between the two is obtained use a color analyzer to measure the white point on Monitor B. Note this value for later use. 6. Profile Monitor B using LightSpace CMS (or CalMAN). If you obtained your perceptual match by adjusting gain controls on Monitor B make sure to set those back to default before profiling. 7. Once your profile is complete create your 3D calibration LUT as you normally would in LightSpace CMS (or CalMAN), with this one exception: instead of using the default target white point enter the x,y chromaticity values in the source window that you noted in step 5. This will generate a custom perceptual match 3D LUT for use on Monitor B. This approach ensures that the matched monitor get a regular calibration procedure as well. It gives a better performance than just shifting the white balance. More details can be found here: http://flandersscientific.com/techresources/perceptualcolormatchingusinglightspacecms.pdf Copyright 2016 JETI Technische Instrumente GmbH 13