ABB Instrumentation Operating Instructions Series Transmitters. Second Retransmission Output Supplement All Models.

Similar documents
Wall-/Pipe-Mount Level Indicator

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

ScreenMaster and ControlMaster Process recorders, controllers and indicator

MICROMASTER Encoder Module

4 Wiring Brochure Wiring and installation of specific control

CONTENTS. Table of Figures

This document courtesy of:

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

Signet 2250 Hydrostatic Level Sensor

COMMANDER 300 Universal Process Controller. Operating Instructions. Serial Data Communication Supplement A1 A2 L R ST M

TVAC20000 User manual

Installation Guide VL-MV10. Model No.

GaAs MULTI-CHIP MODULE MC-7883

Operation Manual for. SCU1 Signal Conditioning Unit

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

PicoScope 2000 Series PC Oscilloscopes

Function Manual SIMATIC HMI TP900. Operator Panel.

PicoScope 4000 Automotive PC Oscilloscopes

KHT 1000C HV-Probe Calibrator. Instruction Manual

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Level Measurement silometer FMC 420, FMC 423

PicoScope 3000 Series Automotive User guide

FIELD MOUNTED RATE TOTALISER MODEL 202D

Atlas SCR. User Guide. Thyristor and Triac Analyser Model SCR100

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Tube Roller Shakers. User Guide. Version 1.2

SCALE & WEIGHT DISPLAYS

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

Section C Recorders. DPR mm Digital Strip Chart Recorder

Installation Operation Maintenance

1 Suunto Cadence POD About Suunto Cadence POD INTRODUCTION INSTRUCTIONS MAINTENANCE

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Instructions. P MHz 1X/10X Passive Probe

Table of contents 1. INTRODUCTION GENERAL CONTENTS OF PACKAGE GENERAL USE OF THE EQUFLOW 6100 D/A CONVERTER STORAGE..

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

USERS MANUAL GR ONE 300 GR ONE 700 GR ONE 1400

BT Diverse Repeater. User Guide

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Part No./ 型号 : RGB-Controller-101

SIM 5 series Lamp Kit

PC-250. SMD Taped Parts Counter Operator s Manual. ISO 9001:2008 Certified. V-TEK, Incorporated 751 Summit Avenue Mankato, MN USA

SmartMix Manual V5350A

User s Manual Model WF100 Extension Cable for EXA100

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

HOME THEATER. HDMI Selector Switches. Vanco Part Numbers (5x1) (3x1) Technical Support

UNIGAS Hand-held combustion gas analyzer with 3 sensors

AWT150C/AWT150CS/ AWT151C CCD Camera

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Colour Explosion Proof Video Camera USER MANUAL VID-C

Sensopress LCD Special English

Gardner Liquid Color Standards Instruction Manual

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

MS2540 Current Loop Receiver with RS485 Communication

Electronic lubrication control unit

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

Total Chlorine Sensor

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Electronic converter for level transmitters MT03L Instructions manual

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL

Tube Rotator. User Guide. Version 1.2

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Level control. Disposing with care. Just scan QR Code and watch the Video. A video says more than a thousand words

Trusted 40 Channel 120 Vac Digital Input FTA

Operating Instructions

HulaMixer Sample Mixer

Operating instructions

KRF EMC Filters Installation, Operation and Maintenance Manual

Operating Instructions

8 Port HD/SD-SDI Switch

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

INSTRUCTION & INSTALLATION GUIDE

800 Displaying Series Flowmeter

Model KT 170 Cooling incubators with thermoelectric cooling

User Guide. Interton TV Streamer

Humidity and Temperature Controllers (Product Code To ) DTH-966 with HYGROTX

Process transmitter RMA422

Model KT 53 Cooling incubators with thermoelectric cooling

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

NEA WIRING CENTRE NEA HT 230V /24 V

DisplayPort to VGA Converter

ROBOT INTERFACE LIGHT

Level 2 Digital Electronics 2 ( )

multi-function meters

VGA to DVI Extender over Fiber SET

User Guide. HDMI Fiber Optic Extender. DVI-7350a

VGA / Audio Extender Single CAT5 / CAT6 with RGB Delay Control & EQ

APSPB PUSH BUTTON ZERO Installation Manual

innocon 6800D Online Luminescent Dissolved Oxygen Analyzer Opera ng Instruc on Dissolved Oxygen NORMAL REL 1 2 WASH 28.1 C jens WALL MOUNTING

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Elcometer Circular Ball Type. Drying Time Recorder. Operating Instructions

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

Operation Manual VMS 3.0 Video System

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

TECHNICAL MANUAL. Operating and Maintenance Instructions for

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

DATAGAUSS XL HARD DRIVE DEGAUSSER

Transcription:

4600 Series Transmitters Operating Instructions Second Retransmission Output Supplement All Models 4600 7.00 Monitoring ph A1 A2 7.00 Monitoring ph 4600 A1 A2 ABB Instrumentation

ABB INSTRUMENTATION The Company ABB Instrumentation is an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. The quality, accuracy and performance of the Company s products result from over 100 years experience, combined with a continuous program of innovative design and development to incorporate the latest technology. BS EN ISO 9001 St Neots, U.K. Cert. No. Q5907 Stonehouse, U.K. Cert. No. FM 21106 EN 29001 (ISO 9001) Lenno, Italy Cert. No. 9/90A The NAMAS Calibration Laboratory No. 0255 is just one of the ten flow calibration plants operated by the Company, and is indicative of ABB Instrumentation s dedication to quality and accuracy. 0255 Stonehouse, U.K. Use of Instructions Warning. An instruction that draws attention to the risk of injury or death. Note. Clarification of an instruction or additional information. Caution. An instruction that draws attention to the risk of damage to the product, process or surroundings. Information. Further reference for more detailed information or technical details. Although Warning hazards are related to personal injury, and Caution hazards are associated with equipment or property damage, it must be understood that operation of damaged equipment could, under certain operational conditions, result in degraded process system performance leading to personal injury or death. Therefore, comply fully with all Warning and Caution notices. Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of Technical Communications Department, ABB Instrumentation. Health and Safety To ensure that our products are safe and without risk to health, the following points must be noted: 1. The relevant sections of these instructions must be read carefully before proceeding. 2. Warning labels on containers and packages must be observed. 3. Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and in accordance with the information given. 4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure and/or temperature. 5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. Normal safe handling procedures must be used. 6. When disposing of chemicals ensure that no two chemicals are mixed. Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets (where applicable) may be obtained from the Company address on the back cover, together with servicing and spares information.

CONTENTS 1 INTRODUCTION Section Page CONTENTS... 1 1 INTRODUCTION... 1 2 ELECTRICAL CONNECTIONS... 2 2.1 Wall-/Pipe-mounted Instrument Connections... 2 2.2 Panel-mounted Instrument Connections... 3 3 PROGRAMMING... 4 3.1 4600 ph Transmitters... 5 3.2 4600 Conductivity Transmitters... 6 3.3 4600 Dissolved Oxygen Transmitters... 7 4 CALIBRATION... 8 4.1 Preparation... 8 4.2 Electrical Calibration Page... 8 This supplement provides additional information on the second retransmission output only, and is to be used in conjunction with the relevent 4600 series transmitter Operating Instructions below at the issue listed or later. ph/redox Transmitters 4630/35 and 4631/36 IM/4600 ph issue 10 Conductivity Transmitters 4620/25 IM/4600 CON issue 9 Conductivity Transmitters 4621/26 IM/4600 MEC issue 6 Conductivity Transmitters 4623/28 IM/4600 USP issue 2 Dissolved Oxygen Analyzers 4640/45 and 4642/47 IM/4600 DO issue 6 Low Level DO Analyzers 4641/46 IM/9437 issue 3 Turbidity Monitors 4670 IM/4670 issue 8 1

2 ELECTRICAL CONNECTIONS This section contains additional wiring information for the second retransmission output and must be used in conjunction with the electrical connection details given in Section 4 of the relevent Operating Instructions see page 1. Warning. Before making any connections, ensure that the power supply, any high voltage-operated control circuits and high common mode voltages are switched off. 2.1 Wall-/Pipe-mounted Instrument Connections Fig. 2.1 1 2 3 1 2 3 4 5 6 7 + N L + 4 5 6 Channel 1 Channel 2 Retrans. 2 Retrans. 1 Relay 1 Power Relay 2 Supply Retransmission 2 + Retransmission Output 2 Fig. 2.1 Second Retransmission Connections, Wall-/Pipe-mounted Instruments 2

2 ELECTRICAL CONNECTIONS 2.2 Panel-mounted Instrument Connections Fig. 2.2 Earth Stud 1 2 3 4 5 6 7 8 9 E N L 1 2 3 4 5 6 7 8 9 10 11 12 TBA TBB Retransmission Output 1 + 1 2 3 4 5 6 7 8 9 E N L 1 2 3 4 5 6 7 8 9 10 11 12 + Retransmission Output 2 Fig. 2.2 Second Retransmission Connections,Panel-mounted Instrument Connections 3

3 PROGRAMMING Access to Secure Parameters 00000 SECURITY CODE Language Page Set Up Parameters Page Set Up Outputs Page Set Up Retransmission 2 Set Up Parameter SET UP OUTPUTS SET UP RETRANS 2 RTX Type 4-20 0-20 0-10 ph CON DO and MEC * RTX O/P ph Red. TEMP * ** CON and MEC * RTX O/P CON TEMP ** DO * RTX O/P DO TEMP ** * Range as for Retransmission 1 ** Range see Table 3.1 Fig. 3.1 Second Retransmission Output Pages and Parameters Electrical Calibration Page ELECTRICAL CAL Adjust RTX Zero Adjust RTX Span Adjust RTX Zero2 Adjust RTX Span2 Return to Operating Page 4

3 PROGRAMMING 3.1 4600 ph Transmitters This section is applicable only to ph transmitters (Models 4630/4631 and 4635/4636). SET UP RETRANS 2 Retransmission 2 Page header RTX Type 4-20 0-20 0-10 RTX O/P ph Red. TEMP Retransmission 2 Output Current Range The retransmission 2 output can be selected from three ma current ranges to ensure compatibility with the peripheral device connected. Select the retransmission output current range required. Retransmission Output Assignment The retransmission output can be assigned to monitor Temperature and either ph or Redox (dependent upon the probe type selected see IM/4600 PH / Section 7.3 / Set Up Parameters Page. ph/red. range as for the Retransmission 1 Output. TEMP range as detailed in Table 3.1. Note. If the sensor type is set to 'Red.', the 'TEMP' option is not available see IM/4600 PH / Section 7.3 / Set Up Parameters Page. Select the retransmission output required. Return to top of page ELECTRICAL CAL Advance to Electrical Calibration Page. Instrument Type 4620/4625 Conductivity 4623/4628 USP Conductivity 4630/4635 ph 4631/4636 ph Water Wash 4640/4645 Dissolved Oxygen 4642/4647 DO Water Wash 4641/4646 Low Level DO 4621/4626 Multi-electrode Conductivity Units 0 to 250mS 250 to 500mS HCl H2SO4 0 to 5% NaOH 5 to 8% NaOH Temp Retransmission Range 0 to 100 C 0 to 40 C 0 to 60 C 0 to 100 C 0 to 50 C 0 to 50 C 0 to 50 C 0 to 100 C 0 to 50 C Table 3.1 Temperature Ranges 5

3 PROGRAMMING 3.2 4600 Conductivity Transmitters This section is applicable only to Conductivity transmitters (Models 4620/4625, 4623/4628 and 4621/4626). SET UP RETRANS 2 Retransmission 2 Page header RTX Type 4-20 0-20 0-10 Retransmission 2 Output Current Range The retransmission 2 output can be selected from three ma current ranges to ensure compatibility with the peripheral device connected. Select the retransmission output current range required. RTX O/P CON TEMP Retransmission Output Assignment The retransmission output can be assigned to monitor Temperature or Conductivity. CON range as for the Retransmission 1 Output. TEMP range as detailed in Table 3.1. Select the retransmission output required. Return to top of page ELECTRICAL CAL Advance to Electrical Calibration Page. 6

3.3 4600 Dissolved Oxygen Transmitters This section is applicable only to Dissolved Oxygen transmitters (Models 4640/4645, 4641/4646 and 4642/47). 3 PROGRAMMING SET UP RETRANS 2 Retransmission 2 Page header RTX Type 4-20 0-20 0-10 Retransmission 2 Output Current Range The retransmission 2 output can be selected from three ma current ranges to ensure compatibility with the peripheral device connected. Select the retransmission output current range required. RTX O/P DO TEMP Retransmission Output Assignment The retransmission output can be assigned to monitor Temperature or DO. DO range as for the Retransmission 1 Output. TEMP range as detailed in Table 3.1. Select the retransmission output required. Return to top of page ELECTRICAL CAL Advance to Electrical Calibration Page. 7

4 CALIBRATION Note. The instrument is calibrated at the Company prior to despatch and an electrical calibration should be carried out only if its accuracy is suspect. 4.1 Preparation Connect test equipment and carry out preparation as detailed in the relevent instrument Operating Instructions see page 1. 4.2 Electrical Calibration Page This section contains calibration details for the second retransmission output only see the relevent instrument Operating Instructions for the full calibration procedure. ELECTRICAL CAL Electrical Calibration Page Header Press the key to select the 'Adjust RTX Zero2' frame. Adjust RTX Zero2 Adjust Retransmission Zero 2 Using the and keys, adjust the milliammeter reading to 4mA. Note. The retransmission range selected in Section 3 does not affect the reading. Advance to the next parameter. Adjust RTX Span2 Adjust Retransmission Span 2 Using the and keys, adjust the milliammeter reading to 20mA. Note. The retransmission range selected in Section 3 does not affect the reading. Return to top of page Return to Operating page Return to the Operating Page. 8

PRODUCTS & CUSTOMER SUPPORT A Comprehensive Instrumentation Range Analytical Instrumentation Transmitters On-line ph, conductivity, and dissolved oxygen transmitters and associated sensing systems. Sensors ph, redox, selective ion, conductivity and dissolved oxygen. Laboratory Instrumentation ph and dissolved oxygen meters and associated sensors. Water Analyzers For water quality monitoring in environmental, power generation and general industrial applications including: ph, conductivity, ammonia, nitrate, phosphate, silica, sodium, chloride, fluoride, dissolved oxygen and hydrazine. Gas Analyzers Zirconia, katharometers, hydrogen purity and purge-gas monitors, thermal conductivity. Controllers & Recorders Controllers Digital display, electronic, pneumatic. Discrete singleloop and multi-loop controllers which can be linked to a common display station, process computer or personal computer. Recorders Circular and strip-chart types (single and multi-point) for temperature, pressure, flow and many other process measurements. Electronic Transmitters Smart & Analog Transmitters For draft, differential, gauge and absolute pressure measurement. Also, liquid level and temperature. Customer Support ABB Instrumentation provides a comprehensive after sales service via a Worldwide Service Organization. Contact one of the following offices for details on your nearest Service and Repair Centre. United Kingdom ABB Instrumentation Limited Tel: +44 (0)1480 475321 Fax: +44 (0)1480 470787 United States of America ABB Automation Inc. Instrumentation Division Tel: +1 215-674-6000 Fax: +1 215-674-7183 Italy ABB Instrumentation SpA Tel: +39 (0) 344 58111 Fax: +39 (0) 344 58278 Client Warranty Prior to installation, the equipment referred to in this manual must be stored in a clean, dry environment, in accordance with the Company's published specification. Periodic checks must be made on the equipment's condition. In the event of a failure under warranty, the following documentation must be provided as substantiation: 1. A listing evidencing process operation and alarm logs at time of failure. 2. Copies of operating and maintenance records relating to the alleged faulty unit. I to P Converters and Field Indicators Flow Metering Magnetic Flowmeters Electromagnetic, insertion type probes and watermeters. Turbine Flowmeters Wedge Flow Elements Mass Flow Meters Transmitters, sensors, controllers and batch/display units. Level Control Submersible, Capacitance & Conductivity. Pneumatic Instrumentation Transmitters Indicating Controllers Recording Controllers

IM/4600 RTX Issue 2 The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB 2000 Printed in UK (03.00) ABB Instrumentation Ltd St. Neots Cambs. England, PE19 3EU Tel: +44 (0) 1480 475321 Fax: +44 (0) 1480 217948 ABB Instrumentation Ltd Analytical & Flow Group Stonehouse, Glos. England, GL10 3TA Tel: +44 (0) 1453 826661 Fax: +44 (0) 1453 827856 ABB Automation Inc. Instrumentation Division 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215-674-6000 Fax: +1 215-674-7183 ABB Instrumentation SpA 22016 Lenno Como Italy Tel: +39 (0) 344 58111 Fax: +39 (0) 344 58278