NEW ELLIPSOIDAL LASER AT THE UPGRADED PITZ FACILITY

Similar documents
Design Studies For The LCLS 120 Hz RF Gun Injector

RUNNING EXPERIENCE OF FZD SRF PHOTOINJECTOR

TESLA FEL-Report

High QE Photocathodes lifetime and dark current investigation

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

Photoinjector Laser Operation and Cathode Performance

The FLASH objective: SASE between 60 and 13 nm

Report on the LCLS Injector Technical Review

Detailed Design Report

First Results and Future of the Photo Injector Test Facility at DESY Zeuthen PITZ. introduction first measurements future schedule

Results of recent photocathode studies at FLASH. S. Lederer, S. Schreiber DESY. L. Monaco, D. Sertore, P. Michelato INFN Milano LASA

DARK CURRENT IN SUPERCONDUCTING RF PHOTOINJECTORS MEASUREMENTS AND MITIGATION

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

STATUS OF THE SwissFEL C-BAND LINAC

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

Cathode Studies at FLASH: CW and Pulsed QE measurements

Summary of the 1 st Beam Line Review Meeting Injector ( )

Summary of recent photocathode studies

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

CLIC Feasibility Demonstration at CTF3

The PEFP 20-MeV Proton Linear Accelerator

RF considerations for SwissFEL

Current status of XFEL/SPring-8 project and SCSS test accelerator

SIMULTANEOUS OPERATION OF THREE LASER SYSTEMS AT THE FLASH PHOTOINJECTOR

Dark current and multipacting trajectories simulations for the RF Photo Gun at PITZ

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

Activities on FEL Development and Application at Kyoto University

Behavior of the TTF2 RF Gun with long pulses and high repetition rates (TESLA note )

New Filling Pattern for SLS-FEMTO

Screen investigations for low energetic electron beams at PITZ

EUROFEL-Report-2007-DS EUROPEAN FEL Design Study

High Rep Rate Guns: FZD Superconducting RF Photogun

KARA and FLUTE RF Overview/status

Present Status and Future Upgrade of KEKB Injector Linac

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

Simulations on Beam Monitor Systems for Longitudinal Feedback Schemes at FLASH.

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera

Technology Challenges for SRF Guns as ERL Source in View of BNL Work

LCLS Injector Technical Review

Status of RF Power and Acceleration of the MAX IV - LINAC

SLAC R&D Program for a Polarized RF Gun

SPEAR 3: Operations Update and Impact of Top-Off Injection

PROJECT DESCRIPTION. Longitudinal phase space monitors for the ILC injectors and bunch compressors

First operation of cesium telluride photocathodes in the TTF injector RF gun

XFEL High Power RF System Recent Developments

Digital BPMs and Orbit Feedback Systems

Photocathodes FLASH: Quantum Efficiency (QE)

Production of quasi-monochromatic MeV photon in a synchrotron radiation facility

Pulses inside the pulse mode of operation at RF Gun

Intra-train Longitudinal Feedback for Beam Stabilization at FLASH

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Low Level RF for PIP-II. Jonathan Edelen LLRF 2017 Workshop (Barcelona) 16 Oct 2017

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

POLARIZED LIGHT SOURCES FOR PHOTOCATHODE ELECTRON GUNS AT SLAC?

4.4 Injector Linear Accelerator

Recent APS Storage Ring Instrumentation Developments. Glenn Decker Advanced Photon Source Beam Diagnostics March 1, 2010

5 Project Costs and Schedule

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

FIRST SIMULTANEOUS TOP-UP OPERATION OF THREE DIFFERENT RINGS IN KEK INJECTOR LINAC

Photo cathode RF gun -

STATUS AND COMMISSIONING RESULTS OF THE R&D ERL AT BNL*

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

Development of high power gyrotron and EC technologies for ITER

The Elettra Storage Ring and Top-Up Operation

45 MW, 22.8 GHz Second-Harmonic Multiplier for High-Gradient Tests*

Studies on an S-band bunching system with hybrid buncher

Status of CTF3. G.Geschonke CERN, AB

Summary report on synchronization, diagnostics and instrumentation

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

PoS(EPS-HEP2015)525. The RF system for FCC-ee. A. Butterworth CERN 1211 Geneva 23, Switzerland

Drive Laser Operations

Implementation of the feed forward correction for the FLASH photo injector laser and future plans for a feedback system

News from HZB / BESSY Wolfgang Anders at ESLS-RF Meeting September 2010 Trieste

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

Basic rules for the design of RF Controls in High Intensity Proton Linacs. Particularities of proton linacs wrt electron linacs

RF Design of the LCLS Gun C.Limborg, Z.Li, L.Xiao, J.F. Schmerge, D.Dowell, S.Gierman, E.Bong, S.Gilevich February 9, 2005

LLRF at SSRF. Yubin Zhao

THE NEXT LINEAR COLLIDER TEST ACCELERATOR: STATUS AND RESULTS * Abstract

Suppression of Timing drift between laser and electron beam driven photo-cathode RF gun

Diamond RF Status (RF Activities at Daresbury) Mike Dykes

The TESLA RF System. S. Choroba. for the TESLA Collaboration. DESY Notkestr. 85, D Hamburg, Germany

Nick Walker DESY MAC

Compact, e-beam based mm-and THzwave light sources

Operation of CEBAF photoguns at average beam current > 1 ma

The ESS Accelerator. For Norwegian Industry and Research. Oslo, 24 Sept Håkan Danared Deputy Head Accelerator Division Group Leader Beam Physics

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

Advanced Photon Source - Upgrades and Improvements

Linac 4 Instrumentation K.Hanke CERN

Research and Development on Superconducting Radio-Frequency Technology for Electron Linear Accelerators. Deliverable

BUNCH-COMPRESSOR TRANSVERSE PROFILE MONITORS OF THE SwissFEL INJECTOR TEST FACILITY

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

P. Emma, et al. LCLS Operations Lectures

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

SRF GUN DEVELOPMENT OVERVIEW

Magnetized-Beam Formation and Beam-Beam Kicker for Electron Cooling

Transcription:

Proceedings of FEL05, Daejeon, Korea NEW ELLIPSOIDAL LASER AT THE UPGRADED PITZ FACILITY J. Good #, G. Asova, M. Bakr, P. Boonpornprasert, M. Gross, C. Hernandez-Garcia, H. Huck, I. Isaev, D. Kalantaryan, M. Khojoyan, G. Kourkafas, M. Kraslinikov, D. Malyutin $, D. Melkumyan, A. Oppelt, M. Otevrel, Y. Renier, T. Rublack, F. Stephan, G. Vashchenko, Q. Zhao, Deutsches Elektronen-Synchrotron, Zeuthen, Germany I. Hartl, S. Schreiber, Deutsches Elektronen-Synchrotron, Hamburg, Germany A. Andrianov, E. Gacheva, E. Khazanov, S. Mironov, A. Poteomkin, V. Zelenogorsky, Institute of Applied Physics, IAP, Nizhny Novgorod, Russia E. Syresin, JINR, Dubna, Moscow Region, Russia O. Lishilin, G. Pathak, Hamburg University, Hamburg, Germany Abstract High brightness photoinjectors for superconducting linac-based FELs are developed, optimized and characterized at the Photo Injector Test facility at DESY in Zeuthen (PITZ). Last year the facility was significantly upgraded with a new prototype photocathode laser system capable of producing homogeneous ellipsoidal pulses. Previous simulations have shown that the corresponding pulses allow the production of high brightness electron bunches with minimized emittance. Furthermore, a new normal conducting RF gun cavity was installed with a modified two-window waveguide RF feed layout for stability and reliability tests, as required for the European XFEL. Other relevant additions to the facility include beamline modifications for improved electron beam transport through the PITZ accelerator, refinement of both the cooling and RF systems for improved parameter stability, and preparations for the installation of a plasma cell. This paper describes the facility upgrades and reports on the operational experience with the new components. ELLIPSOIDAL LASER SYSTEM Previously reported [] low emittance beams were obtained using a flat-top temporal laser profile with 60 MV/m in the RF gun, and more recently new measurements have been taken with a Gaussian temporal laser profile and 53 MV/m []. Also recently it was found that the transverse halo of the laser must be taken into account [3]. In earlier simulations it was found that uniform ellipsoidal charge distributions with sharp charge transition boundaries would produce even higher beam quality. Furthermore, it was shown that such electron bunches are also less sensitive to machine parameter jitter [4] and therefore increase the reliability and stability - crucial parameters for single-pass FELs such as FLASH and the European XFEL. # james.david.good@desy.de on leave from BAS INRNE, 784 Sofia, Bulgaria on leave from Assiut University, 755 Assiut, Egypt on leave from JLab, Newport News, VA 3606, USA on leave from IMP/CAS, 730000 Lanzhou, China $ now at Helmholtz-Zentrum Berlin, Berlin, Germany now at Synchrotron SOLEIL, Paris, France Naturally, a homogenous ellipsoidal photocathode laser pulse can be used to produce such charge distributions. Consequently, such a laser system has been developed for PITZ by the Institute of Applied Physics in Nizhny Novgorod, under the framework of a joint German- Russian research activity [5]. The system produces quasi-ellipsoidal laser pulses in the infrared through spectral amplitude-phase masking. WP half-wave plates, CL cylindrical lens, FR Faraday rotator, CW calcite wedge, diffraction gratings Diff.gr. Figure : Schematic overview of the 3D shaper. The shaper consists of two diffraction gratings, two Spatial Light Modulators, and various optical elements (Fig. ). A chirped infrared laser pulse is transformed into the spectral domain with a diffraction grating and imaged onto Spatial Light Modulators (SLMs) whereupon masks such as in Fig. are applied. The beam is then recombined via another grating, rotated 90º about its propagation axis, and passed back through the shaper again. This shapes the perpendicular transverse axis and produces a quasi-ellipsoidal distribution. Finally, the beam is converted from infrared to the ultraviolet via nonlinear 4 th harmonic frequency conversion. Simulations have been done to produce the mask in Fig. a) which is expected to roughly produce the quasiellipsoidal distribution in Fig. b). Simulations have shown that these improved laser pulses have the potential to further reduce the emittance of the generated electron bunches at PITZ [4]. 439

Proceedings of FEL05, Daejeon, Korea a) NEW GUN AND RF FEED SYSTEM During the summer/autumn of 04 the RF feed system and the gun at PITZ were replaced (Fig. 4). Gun 4.4 was exchanged with a Gun 4., while the RF feed changed from a single Thales RF window layout [6] to a double RF window-pair layout [7]. This was owing to high-load induced damage of the Thales window. Naturally, sharing of the load across two windows has reduced both the potential damage to the components and the likelihood of interruptive instances, thereby improving stability and reliability of the system. b) Figure : a) The corresponding normalized amplitude and phase masks. b) Temporal slices of a simulated quasiellipsoidal laser pulse. t=0 ps corresponds to the temporal center of the laser pulse. The laser pulses are characterized by a cross-correlator coupled camera in the infrared (Fig. 3) prior to frequency conversion to the ultraviolet. Owing to the non-linarites inherent to the conversion process a UV:IR scanning cross-correlator is planned in order to fully characterize the shaped UV pulses. The first photoelectrons were produced with this system in spring and captured with a Faraday cup. The beamline and system are currently undergoing testing, commissioning, and further improvements. Figure 4: New gun interlock and RF distribution scheme. However, the nominal operation target of FLASH and XFEL has not been reached owing to limitations of the gun itself. This can be attributed to the gun s troubled history [7]. Reduction of the operating power to 5 MW has shown a remarkable improvement in gun stability. RF GUN STABILITY Figure 3: Cross-correlation measurement of a shaped pulse produced in the lab. Shown are ~50 fs time slices of the transverse distributions of the shaped laser pulse taken at.7 ps intervals throughout the entire pulse duration of 3.6 ps. One of the main tasks of PITZ is demonstration of stable operation of the RF gun at the European XFEL injector specifications. The specifications are an RMS amplitude jitter of less than 0.0% as well as an RF phase RMS jitter smaller than 0.0 deg. These challenging stability requirements have to be achieved within the RF pulse and from pulse-to-pulse. 440

Proceedings of FEL05, Daejeon, Korea Nominal RF pulses of 650 us flattop length at ~6.4 MW peak power in the gun cavity and 0 Hz repetition rate have to be stably supported for the European XFEL RF gun. For the initial start-up conditions a reduced peak power of 4.5-5 MW is foreseen. A new low-level RF (LLRF) system has been implemented at PITZ since November 04. It is based on μtca [8] technology and imparts an increased measurement sampling rate within the RF pulse as well as extended feedback (FB) tools permitting improved regulation of the amplitude and phase of the RF gun. Another tool to stabilize the normal conducting RF gun is the water cooling system (WCS). High temperature stability of the gun cavity is realized by heat transport control. The WCS implemented at PITZ currently has two functional modes: operation (WCS=oper) and stabilization (WCS=stab). The former actively regulates the gun s water circuit through valve-controlled mixing of cold water into the loop. Whereas, the latter employs a heat exchanger to regulate the closed warm water loop thereby reducing flow perturbations. Results of the stability measurements based on the statistical analysis of 800 subsequent RF pulses are shown in Fig. 5, where RMS phase and amplitude jitters within the RF pulse are plotted for various WCS and FB modes. These measurements have been performed for the peak RF power in the gun of 4.5 MW and 640 μs RF pulse duration. and significant reduction of the phase jitter (~75%). However, further improvements to the RF gun stability have to be implemented (factor 5 for the phase and factor for the amplitude) in order to achieve the European XFEL injector specifications. The RF stability measurements were cross-checked with electron beam measurements based on the fluctuations of the electron bunch charge as a function of the RF gun launch phase. The analytic approach used to fit the measured mean charge <Q> and charge fluctuations Q assumed three independent and normally distributed sources of charge fluctuation: phase jitter, laser pulse energy fluctuations, and electronic noise of the charge measurement device (Faraday cup). It is also presumed that the temporal profile of the photocathode laser pulse is Gaussian as it was in the measurements. In order to minimize the influence of the space charge effect the space charge density at the cathode was reduced by decreasing the photocathode laser fluence. An example of the measured <Q> and Q together with fitted curves are shown in Fig. 6. The phase RMS jitter obtained from these fits is plotted in Fig. 5. Figure 5: RF gun stability measurements. The RMS phase and amplitude jitter is plotted at left and right axis correspondingly for two regimes of the WCS and deactivated/activated LLRF feedback (measurements S5, S7 and S8). Results of the correspondent beam-based measurements are shown with markers. The horizontal position of these points corresponds to the time of the first electron bunch within the RF pulse. As can be seen from these measurements, without feedback switching the WCS from operation mode to the stabilization mode improves the amplitude stability by a factor of 3 and the phase jitter is reduced by ~0%. Whereas, application of the LLRF feedback results in further reduction of the amplitude jitter by a factor of ~3 Figure 6: Beam based measurements of the RF gun stability. Measured mean charge and its analytical fit are plotted at the left axis. Charge fluctuations together with fits for three cases of WCS and FB (measurements S5, S7 and S8) are plotted at right axis. PHOTOEMISSION STUDIES One of the many areas of interest is the charge production behaviour of the Cs Te cathodes used in both FLASH and PITZ. While significant amounts of charge can be extracted from the cathodes it has been observed that the quantum efficiency (QE) of the cathode constantly decreases as a function of time (~ year) before partially recovering (Fig. 7) [9]. 44

Proceedings of FEL05, Daejeon, Korea Figure 7: Quantum Efficiency of FLASH s Cs Te Cathode 68.3 during 03/04. To investigate this behaviour one of the measurement programs embarked upon has been to map the QE over the surface of the cathode as a function of time. It was seen that the QE consistently degrades across the entire surface of the cathode, within a period of one month, despite charge extraction occurring primarily at the centre. The evolution of existing defects and the formation of new ones can also be observed (Fig. 8). On longer time scales, on another cathode at PITZ, effects similar to those measured at FLASH have been observed. Similarly, another unexplained aspect of charge extraction from the cathode was the increase of photoemission with laser pulse energy contrary to previous simulations (Fig. 9). According to simulation a uniform (flat-top) transverse laser profile, the extracted charge should saturate beyond certain laser pulse energy, corresponding to specific beam parameters and gun operating settings. However, in reality the photocathode laser does not have a perfect flat-top transverse profile. Therefore a detailed investigative measurement program was begun to fully characterize the transverse profile of the laser and to produce a comparative set of photoemission data [3]. Cathode#679.; QE(BSA=.mm)=0.% [05069N] Y (mm).5 0.5 0-0.5 - -.5 - -.5 - - 0 3 X (mm) Cathode#679.; QE(BSA=.mm)=7.8% [05070N] Y (mm).5.5 0.5 0-0.5 - -.5 - -.5 - - 0 X (mm) Figure 8: Evolution of cathode surface QE over one month. 44 % % 0 9 8 7 6 5 4 3 0 9 8 7 6 5 4 3 Figure 9: Extracted charge and expected charge given by simulation of a homogenous, transversely flat-top laser pulse (red) and the same distribution with a photonic halo (blue), and measurement of charge actually extracted (green). The resulting simulations have shown that the previously observed discrepancy can be easily explained by rising Gaussian edges of the transverse laser profile generating a halo of charge around the core beam. Furthermore, this effect is constantly more pronounced across all gun gradients for more narrow transverse profiles where the ratio of core:halo area is decreased. FURTHER FACILITY DEVICES Additionally, commissioning of a transverse deflecting cavity (TDS) started in July 05. The preliminary results are promising [0] as beam measurements are in good agreement with RF readings However, full operation of the device was limited by high reflection in the waveguide line. A plasma cell was constructed in 03 for doing proof of concept measurements for the AWAKE experiment at CERN []. The device consists of a heatpipe oven for the vaporization of lithium, Kapton foil windows to separate the volume from the beamline vacuum, and a 93nm ionizing laser to produce the plasma. The chamber has recently undergone successful mechanical, vacuum, and thermal stress tests and was placed into the beamline for the first time in July.

Proceedings of FEL05, Daejeon, Korea SUMMARY AND OUTLOOK Preparatory simulations were done for the new ellipsoidal photocathode laser system. This has yielded trial phase-amplitude masks which have been tested and characterized with a scanning IR cross-correlator coupled camera. Photoelectrons have been generated with the system and development is ongoing. The RF system has shown itself to be very reliable under a two RF window-pair solution and has been operated at full XFEL RF specifications without issue. The RF system will be fully assessed with the newly manufactured gun 4.6 which is planned to be installed until the end of 05. The phase and amplitude regulation of the RF gun has been improved by switching the LLRF to a μtca-based system and by further improvement of the gun s water cooling system. Photoemission studies have been performed and it was also determined by simulation, and confirmed by experimental data, that the irregularities of the transverse laser profile on the cathode have to be fully included in simulation. Finally, the Transverse Deflecting Structure is in the commissioning phase and is expected to deliver extended diagnostic capability and insightful experimental data. Also experiments with a plasma cell have started to do proof-of-principle experiments in the field of particle beam driven plasma wakefield acceleration. REFERENCES [] M. Krasilnikov et al., Experimentally minimized beam emittance from an L-band photoinjector, PRST AB 5, 0070 (0). [] G. Vashchenko et al., Emittance Measurements of the Electron Beam at PITZ for the Commissioning Phase of the European X-FEL, these proceedings (MOD04), FEL 5, Daejeon, Korea. [3] C. Hernandez-Garcia et al., "Studies on charge production from CsTe photocathodes in the PITZ L-band normal conducting radio frequency photo injector," in preparation, to be submitted to Phys. Rev. ST Accel. Beams. [4] M.Khojoyan et al., Optimization of the PITZ photo injector towards the best achievable beam quality,proc. FEL04, Basel, Switzerland (04). [5] T.Rublack, First Results Attained with the Quasi 3-D Ellipsoidal Photo Cathode Laser Pulse System at the High Brightness Photo Injector PITZ, IPAC 5, Richmond, VA, USA (05). [6] M.Otevrel et al., Report on Gun conditioning activities at PITZ in 03, Proc. IPAC 4, Dresden,Germany (04). [7] A. Oppelt et al., Facility Upgrade at PITZ and First Operation Results, IPAC 5, Richmond, VA, USA (05). [8] M.Hoffmann et al., Operation of Normal Conducting RF Guns with MTCA.4, IPAC 5, Richmond, VA, USA (05). [9] S. Schreiber and S. Lederer, Lifetime of CsTe Cathodes Operated at the FLASH Facility, these proceedings (TUP04), FEL 5, Daejeon, Korea. [0] H. Huck et al., First Results of Commissioning of the PITZ Transverse Deflecting Structure, these proceedings (MOP039), FEL 5, Daejeon, Korea. [] M. Gross, et al., Preparations for a plasma wakefield acceleration (PWA) experiment at PITZ, Nuclear Instruments and Methods in Physics Research A 740 (04), pp. 74-80. 443