Installation Guide. CTI/16 RS422/BBV Coax Telemetry Interface 16 channel. Building Block Video Ltd., Diplocks 17 Apex Park Industrial Estate,

Similar documents
Installation Guide. CTI/16 RS422/BBV Coax Telemetry Interface 16 channel. Building Block Video Ltd., Diplocks 17 Apex Park Industrial Estate,

Installation Guide. CTI/8 RS422/BBVCoax Telemetry Interface 8 channel. Building Block Video Ltd., 17 Apex Park,

Installation Guide. CTI/1 RS422/BBV Coax Telemetry Interface Single Channel

BBV REAL TIME HQ DISPLAY QUAD MANUAL

Installation Guide RX10X. Multi Protocol Dome Interface Receiver

Telemetry Receiver Installation Guide

Telemetry Receiver Installation Guide

Rx400DC TELEMETRY RECEIVER INSTALLATION GUIDE

SCT CAMERA CONTROL CODE TRANSLATOR AD MANCHESTER to PELCO RS-422 Ver. 1.51

Model: AV D Keyboard Controller. User Manual. Please Read this User Manual throughout before using.

SY-HDBT-100 Extender Set

KBC1 / KBC2. Installation and Operation Guide

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

Active UTP Transceiver Hub Installation Guide

AU-A300 Integrated 2 Channel Zone Amplifier OPERATION MANUAL

CMLUX-4H4CAT. 4 by 4 HDMI V1.3 over CAT 6 Matrix with IR Return Control. Operation Manual CMLUX-4H4CAT

Quick Operation Guide of LTN7700/7600 Series NVR

ARS x4 MATRIX SWITCHER Instruction Manual

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

Model 1421 Distribution Amplifier

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

EL-5500 Advanced HDMI/VGA Presentation Switch OPERATION MANUAL

User Manual POE. Twisted Pair POE Extender

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

SY-HDBT-SLIM-100S Extender Set

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

PRO-SDI44/84/124/164. 4x4/8x4/12x4/16x4 3G-SDI Matrix Switchers OPERATION MANUAL

High Definition Digital Video Tracking Matrix Switcher

Active UTP Transceiver Hub

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

CMSDI G-SDI Matrix

CP-255ID CV, SV, VGA and DVI to DVI Scaler / Converter OPERATION MANUAL

SIMATRIX NEO V2 Modular Video Matrix

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

MS2540 Current Loop Receiver with RS485 Communication

ZIG-POC-100. HDBaseT HDMI Extender

ZIG-POEPRO-70A. HDBaseT HDMI Extender

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

.Power Distribution Center. PD-1. Instruction Manual

EGE-IR Bi-directional Infrared Matrix

PU-4H4HBT 4 x 4 HDMI HDBaseT Matrix (inc. PoE) OPERATIONS MANUAL

NS-3 RF Noise Source Operation Manual

Marshall Electronics. Broadcast A/V Division VAC-HT12-KIT. 4K HDBaseT Extender Kit. User Manual

DIGI-BSR-4K Installation Guide

OWNER S MANUAL. HDBaseT EXTENDER B-500-EXT-330-RS-IP

CP-255ID Multi-Format to DVI Scaler

Salient Systems June, N Mopac Expy, Bldg 3, Ste 700 Austin, Texas FAX

E3/DS3 Fibre Extender

HDBaseT Extender Set 100m User Guide

Quick Installation Guide

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

User Manual TP422P-4K. Ultra-thin HDBaseT Extender. All Rights Reserved. Version: TP422P-4K_2016V1.1

-TECH DIGITAL. Explore The High DefinitionWorld. Website: Hot Line: [US] USER MANUAL

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX

Monochrome Video Monitors

VGA & RS-232 & Audio CAT5 Extender with RGB Delay Control Quick Installation Guide

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

CH-2538TXWPKD 4K UHD HDMI/VGA over HDBaseT Wallplate Transmitter. CH-2527RX 4K UHD HDMI over HDBaseT Receiver. Operation Manual

EFFECTIVE CCTV, HONESTLY PRICED.

Salient Systems July, N. MoPac Expy. Building 3, Suite 700 Austin, TX FAX

CH-1602TX & CH-1602RX HDMI/Audio over CAT5e/6/7 Extender with 48V PoE

HVWIP-Series (HVWIP-T + HVWIP-R)

TBC & Matrix Switcher TBC-5000 Instruction Manual

AMU2-2MHD+ Audio monitoring Unit

Wireless 1080P HDMI Video Kit - Mid-Range

Operating Instructions

PU-507-KIT. v1.4 HDMI over Single CAT5e/6 HDBaseT 5Play, Single LAN, Set (up to 100m) OPERATION MANUAL

PU-304-KIT Digital Audio over CAT6 Extender TXRX Set OPERATIONS MANUAL

Stratos Duo RGB. User Manual. Order code: EQLED371

Instructions Manual

HDBaseT EXTENDER B-600-EXT-330-RS-IP INSTALLATION MANUAL

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

switching, distribution, interfacing and control products for computer graphic, multi-media and audio visual systems integration

4 Channel Video and IP Over Fiber Extender Kit with RS485 Data. User Manual L-4VID-1IP-FE-TX-RX

Model: UHD41-ARC. Installation Guide

CH-1605RXV 4K UHD+ HDMI over HDBaseT 2.0 Receiver (PD) with HDR/ARC

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Multi-Channel Passive Transceiver Hubs Installation Sheet

Operating Manual. CAT5 Audio Balun KD-CAT5XST

CS-801H HD High Resolution Scaler with 3D

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

CDVI-1109TXC & RXC DVI over CAT5e/6/7 with LAN/PoC/IR Extender

3GSDI Audio Embedder

Users Manual. altus VTR/DDR Controller HT201, HT211, HT212. Software version: 3.0

VGA, Audio & RS-232 Serial with IR Pass-Thru over Single CAT5 /RJ45 Extender Kit

User Manual. HDBaseT Receiver CMHDBTBRX. Front View Panduit Dr, Tinley Park, IL (708)

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

VG A 88 VGA88. 8x8 VGA Matrix Switcher. VGA88 manual.indd 1 12/3/07 2:24:47 PM

HDMI Over CAT5 Receiver at 50 Meters

PoE Over Coax Extender Kit

CohuHD TM Products 9300 SERIES INSTALLATION AND OPERATION MANAUL. Local Control Panel. Figure 1. icontrol. Technical Manual 6x-1034G

ITC-200B Quick Start Guide

PU-607BD-TX HDMI over Single CAT5e/6/7 HDBaseT Bi-directional PoE Transmitter

ANI-PiP-LITE. HDMI 2x1 Multi-Viewer with PIP INSTRUCTION MANUAL. A-NeuVideo.com Frisco, Texas (469) AUDIO / VIDEO MANUFACTURER

DCP100 Digital Control Programmer Specifications

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

CH-507TX & RX HDMI to CAT5e/6 with LAN/IR/RS-232

Transcription:

CTI/16 RS422/BBV Coax Telemetry Interface 16 channel Installation Guide Building Block Video Ltd., 17 Building Apex Park, Block Video Ltd Diplocks 17 Apex Park Industrial Estate, Hailsham, Diplocks Industrial East Sussex, Estate BN27 3JU UK. Tel: Hailsham, +44(0)1323 East Sussex, 842727 BN27 3JU, UK Fax: Tel: + +44(0)1323 1323842728 842727 Support: Fax: + 44 +44(0)1323 842728 444600 www.bbvcctv.com Support: + 44 (0) 1323 444600 www.bbvcctv.com

Contents Pre-installation checks & safety procedures 4 Introduction 5 Unpacking 5 Technical Specification 6 CTI/16 & CTI/8 Software version history 6 Test Mode 7 Setting the protocol & baud rate 8 Address setting 9 Advanced features table 10 CTI/16 Connection details 11 Diagnostic LEDs 12 Intellex DVR controlling domes up the coax via CTI/16 telemetry interface 13 DVX to CTI/16 driving RX100/VCL 14 Vicon matrix controlling CTI/16 with 360 Vision domes 15 2060 Dennard domes with up the coax control & 4 local alarms 16 Philips Bi-Phase matrix to CTI/16 driving an RX55X 17 CTI16 Manual V15.4 April 2014 Page 3/20

PRE-INSTALLATI CHECKS AND SAFETY PROCEDURES Unpacking - Inspect the packaging for signs of damage. If damage has occurred, advise the carrier and/or the suppliers immediately. Unpack the receiver carefully and check that all the items are present and correct (see checklist on box). If any item is missing contact the supplier. Retain packaging - The shipping carton is the safest container in which to transport the unit. Retain undamaged packaging for possible future use. IMPTANT SAFETY PRECAUTIS Read & retain instructions - All relevant safety, installation and operating instructions should be read & retained before attempting to install, connect or operate the unit. Water and moisture - Do not expose the internal electronics of this unit to water or dampness. Power sources - This unit should be operated only from the supplied power supply. Servicing - Servicing of the unit should only be undertaken by qualified service personnel. Damage requiring service - Servicing by qualified personnel should be carried out under the following conditions: (a) When the power supply cord or plug is damaged; (b) If liquid has been spilled, or objects have fallen into, the unit; (c) If the internal electronics of the unit have been exposed to rain or water; (d) If the unit does not operate normally by following the operating instructions. (e) If the unit has been dropped or the enclosure is damaged; Replacement parts - If replacement parts are required, ensure that only replacement parts recommended by the product manufacturer are used. Safety check - Upon completion of any service or repairs to the unit, safety checks should be performed to ensure that the unit is in proper operating condition. Coax grounding - If an outside cable system is connected to the unit, be sure the cable system is grounded. Pre-installation checks - It is recommended that the unit be bench-tested prior to installation on the site. Adhere to Safety Standards - All normal safety precautions as laid down by British Standards and the Health and Safety at Work Act should be observed. WARNING TO PREVENT DANGER OF FIRE SHOCK, DO NOT EXPOSE THE INTERNAL COMPENTS OF THIS EQUIPMENT TO RAIN MOISTURE. CTI16 Manual V15.4 April 2014 Page 4/20

INTRODUCTI GENERAL The CTI/16 is designed to provide conversion from RS422/485 data to BBV Coax Telemetry based systems. Up the Coax telemetry allows upgrading of static cameras to PTZ without the need for additional cabling. One RS422/485 input that is dipswitch selectable. The Baud Rates & Parity for Pelco P/D & Vicon Protocols are variable. Sixteen individual outputs are provided. Each output connects to a single receiver. Each unit is supplied with a break out box and 0.5mtr Cat 6 patch cable. Multiple CTI/16 can be cascaded together giving up to 256 camera outputs. Please Note: Camera address will be limited to the maximum number supported by the individual protocol. Please note: Menu Access commands of cameras can vary between control equipment even if using the same protocol. For Example: In Pelco D protocol - dome menu access commands can be either Goto Preset 95 or Save Preset 95. Enter = Goto Preset 1 or Iris Open / Close Protocols currently supported are: BBV, Pelco P/D, Pelco P DM, VCL, Dennard, Philips, Sensormatic RS422, Molynx, Vicon. The CTI/16 has been tested with the BBV FBM/256 Matrix & Starcard Converter, BBV TX1500/96 Matrix & Starcard Converter, Pelco KBD300, DM DS2, VCL VCTM16 Matrix & Maxcom 8 Matrix & Keyboard, Philips Allegiant 32 Camera Matrix LTC8301/50 & Bi Phase to RS232 Converter LTC8780/50, American Dynamics Intellex LT V4 Software, Molynx TTX600 Keyboard & TTX6164T Matrix and Vicon VI411-DVC Keyboard Unpacking Inspect the packaging for signs of damage. If damage has occurred, advise the carriers and/or the suppliers immediately. Unpack the interface carefully and check all the items are included: CTI/16 RS422/BBV Coax Telemetry Interface 16 channel X CAT6 patch cable X Break out box X Mounting brackets X 9 to 12Vdc PSU X Manual X CTI16 Manual V15.4 April 2014 Page 5/20

Technical Specification Power Requirements Inputs 9 to 12Vdc PSU 500mA 2 Wire RS485, 2 Wire RS422 Simplex and 4 Wire Full Duplex (switch selectable input protocol) Maximum Cable Distance Belden 8723 = 1200m Outputs Supported Protocols 16 x BBV Coax Telemetry Maximum Cable Distance BBV422 9600 Pelco P 2400, 4800 & 9600 Pelco P DM 2400, 4800 & 9600 Pelco D 2400, 4800 & 9600 VCL 9600 Dennard 9600 Philips 9600 Sensormatic 4800 Molynx 9600 Vicon 4800, 9600, 19200 RG59 = 250m CT125 = 500m Facilities LED as power indication Boxed Dimensions Installation Supplied in 19 1 U rack mountable case Length 425mm Depth 110mm Height 43mm The unit is designed to either be fitted into a 19 rack or wall mounted via the fixing brackets supplied CTI/16 Manual & Software Version History Version 15.4 April 2014-1. Updated layout to Protocols pages 5&6-2. Visio drawings updated from Rx100 to Rx10X Version 15.2 June 2010-1. Change to the Test mode page Version 15A June 2010-1. Change to the Sensormatic commands on page 9 Version 15 11 December 2009-1. Added Test feature. Pan Left & Right via dipswitches Version 1 8 May 2008-1. CTI/8 Released Version 13 15 October 2007-1. Bug fix for address 27 in Dennard RS485 Protocol Version 12 10 October 2007-1. Bug fix for address 2 & 3 in Dennard RS485 Protocol Version 11 3 September 2007-1. Updated Support of VCL Telemetry from Maxcom 8 Matrix -2. Manual Update Version 10 15 August 2007-1. Bug fix of VCL Telemetry from Maxcom 8 Matrix Version 9 10 July 2007-1. Updated Support of VCL Telemetry from Maxcom 8 Matrix Version 8 17 March 2007-1. Updated support of Hash Command release time -2. Manual update. Version 7 13 February 2007-1. Added continuous sending of telemetry for legacy coax receivers Version 6 8 January 2007-1. Molynx Protocol Speed table recalibration Version 5 11 December 2006-1. Bug fix for Accumulative Delays in Pelco P & D and Dennard RS485 Routines - 2. Updated watchdog routine - 3. Added support for Sensormatic RS422 Protocol - 4. Added support for Molynx RS485 Protocol - 5. Added support for Vicon RS485 Protocol variable Baud Rate Version 4 18 November 2005-1. Added support for Pelco P/D Protocol variable Baud Rate & Parity settings. - 2. Added support for Pelco P DM Auxiliary outputs. Version 3 27 June 2005-1. Added support for Dennard 2050 Protocol. Version 2 25 May 2005-1. Added support for Philips RS485 Protocol. Version 1 11 November 2005-1. CTI/16 Released Support of BBV, Dennard, Philips, Pelco P & D and VCL RS485 input protocols converting to BBV Coax output protocol. CTI16 Manual V15.4 April 2014 Page 6/20

Test Mode This feature enables the Camera to be driven left or right from the Coax Telemetry Interface directly SW2 Sets Test Mode SW1 Sets Camera Number & Direction 7 = Pan Left 8 = Pan Right SW1 Cam 1 Pan Left SW1 Cam 2 Pan Left SW1 Cam 3 Pan Left SW1 Cam 4 Pan Left SW1 Cam 5 Pan Left SW1 Cam 6 Pan Left SW1 Cam 7 Pan Left SW1 Cam 8 Pan Left SW1 Cam 9 Pan Left SW1 Cam 10 Pan Left SW1 Cam 11 Pan Left SW1 Cam 12 Pan Left SW1 Cam 13 Pan Left SW1 Cam 14 Pan Left SW1 Cam 15 Pan Left 1 2 3 4 5 5 6 7 7 8 SW1 Cam 16 Pan Left CTI16 Manual V15.4 April 2014 Page 7/20

Setting the Protocol and baud rate The CTI/16 will only output BBV Coax Telemetry on the 16 Coax output channels The CTI/16 supports various RS422/485 input Protocols SW2 Sets Protocol & Baud Rate SW1 Sets Address & Parity 7 & 8 OFF = None Parity 7 & 8 = Odd Parity 7 OFF & 8 = Even Parity Input Termination SW2 BBV 9600 N 8 1 SW2 Pelco P 9600 N 8 1 SW2 Pelco P 4800 N 8 1 SW2 Pelco P 2400 N 8 1 SW2 Pelco P DM 9600 N 8 1 SW2 Pelco P DM 4800 N 8 1 SW2 Pelco P DM 2400 N 8 1 SW2 Pelco D 9600 N 8 1 SW2 Pelco D 4800 N 8 1 SW2 Pelco D 2400 N 8 1 SW2 VCL 9600 N 8 1 SW2 Dennard 9600 N 8 1 SW2 Philips 9600 N 8 1 SW2 Sensormatic 4800 N 8 2 SW2 Molynx 9600 E 8 1 1 2 3 4 5 5 6 7 7 8 SW2 Vicon 19200 N 8 1 SW2 Vicon 9600 N 8 1 SW2 Vicon 4800 N 8 1 CTI16 Manual V15.4 April 2014 Page 8/20

SW1 Sets Address Address Settings The CTI/16 supports a maximum of 256 addresses A maximum of 16 x CTI/16 can be cascaded together N.B. Refer to input Protocol documents for maximum address supported i.e. Pelco P max addr = 32 Address Range 1-16 Address Range 17-32 Address Range 33-48 Address Range 49-64 Address Range 65-80 Address Range 81-96 Address Range 97-112 Address Range 113-128 Address Range 129-144 Address Range 145-160 Address Range 161-176 Address Range 177-192 Address Range 193-208 Address Range 209-224 Address Range 225-241 Address Range 242-256 CTI16 Manual V15.4 April 2014 Page 9/20

Advanced Features Table BBV COAX OUTPUT BBV Tx1500 1# 2# 3# 4# START 1 PATROL START 2 PATROL 1# 2# 3# 4# 1 PATROL 2 PATROL START AUTOPAN AUTOPAN PELCO SAVE PRESET 95 PRESET 61 PRESET 33 PRESET 62 PRESET 94 PRESET 63 PRESET 64 PRESET 66 PRESET 67 PRESET 68 VCL PRESET 95 PRESET 61 PRESET 62 PRESET 63 PRESET 64 PRESET 66 PRESET 67 PRESET 67 DENNARD SAVE PRESET 95 PRESET 61 PRESET 33 PRESET 62 PRESET 94 PRESET 63 PRESET 64 PRESET 66 PRESET 67 PRESET 67 PHILIPS AUX 46 PRESET 61 AUX 63 PRESET 62 AUX 100 /OFF PRESET 63 SET 899 PRESET 64 PRESET 66 PRESET 67 PRESET 67 SENSMATIC START PATTERN 3 REPEATED 5 TIMES FOLLOWED BY SAVE PRESET 1 PRESET 61 SEE note 1 START PATTERN 3 REPEATED 5 TIMES FOLLOWED BY SAVE PRESET 1 PRESET 62 SEE note 1 START PATTERN 3 REPEATED 5 TIMES FOLLOWED BY SAVE PRESET 1 PRESET 63 SEE note 1 START PATTERN 3 REPEATED 5 TIMES FOLLOWED BY SAVE PRESET 2 PRESET 64 SEE note 1 PRESET 71 PRESET 72 PRESET 73 MOLYNX AUX 1 PRESET 61 AUX 2 PRESET 62 HOME PRESET 63 CAMERA On/Off PRESET 64 PRESET 66 PRESET 67 PRESET 67 VIC SAVE PRESET 94 95 PRESET 61 PRESET 62 PRESET 63 PRESET 64 PRESET 66 PRESET 67 PRESET 67 NOTE1. 5min time out / Goto Preset 6 to Cancel When using BBV422 & Pelco P you can toggle wash, wipe & lights with Goto Preset commands: Preset 81 Wash on, Preset 82 Wash off, Preset 83 Wipe on, Preset 84 Wipe off, Preset 85 Lights on & Preset 86 Lights off. CTI16 Manual V15.4 April 2014 Page 10/20

CTI/16 Connection Details The CTI/16 unit is supplied with a Cat 6 Patch cable and a Break Out Box. GREEN RED TXB (FROM Controller) = 5 (CAT5) WHITE/BLUE 4 = TXA (FROM Controller) (CAT5) BLUE YELLOW BLACK Connection information RXB (TO Controller) = 6 (CAT5) GREEN BROWN ANGE 3 = RXA (TO Controller) (CAT5) WHITE/GREEN TXA (FROM Controller) DATA + from the DVR/ MATRIX to CTI16 Gnd = 7 (CAT5) WHITE/BROWN 2 =NC (CAT5) ANGE TXB (FROM Controller) DATA - from the DVR/ MATRIX to CTI16 WHITE BLUE RXA (TO Controller) DATA + to the DVR/ MATRIX from CTI16 Gnd = 8 (CAT5) BROWN 1 =NC (CAT5) WHITE/ANGE RXB (TO Controller) see RS422 NOTE DATA - to the DVR/ MATRIX from CTI16 RJ45 Surface Socket FARNELL No 454-485 RS422 NOTE Some systems require RS422 FULL DUPLEX before they will work. Some Sensormatic systems require a 4 Wire connection. CTI16 Manual V15.4 April 2014 Page 11/20

POWER INPUT 9-12 DC 500mA POWER LED RS422/485 PT Diagnostic LEDs SW2 BBV422 SW1 Address Range 1-16 SW1 SW2 LD10 J19 LD10 LD8 LD7 LD6 LD5 LD4 LD3 LD2 LD1 J9 SW1 SW2 02008 iss 3 Bit 7 Tx Termination Bit 8 Rx Termination BBV LD 1-8 If there are no video sources you will see LD1 to 8 flash in sequence. When a video source is applied to either input the associated LED will be on constantly. LD 10 LD10 will flash when the CTI/16 is sending data to the coax driver chips, even if there are no video sources. This is a good way to test if the CTI/16 is connected and configured correctly. CTI16 Manual V15.4 April 2014 Page 12/20

Sensormatic Borsatec BT2790FF VIDEC Dennard Domes Panasonic LG Domes CBC C-View Samsung CBC C-All View JVC TX_C676 Pelco Domes Pelco Esprit Bosch Domes Vicon Surveyor VCL Honeywell Vista Powerdome Please note this is a small selection of the domes that can be controlled by the BBV Rx10X. For a full list of dome please refer to the BBV website www.bbvcctv.com. It is important that the Rx10X must be close to the dome within 5 meter is recommended. The CTI Card can control the full range of BBV Coax Receivers Rx200 AC output, Wash, Wipe, Lights for static cameras Rx300 AC output, Pan/Tilt/Zoom/Focus + choice of Wash, Wipe, Lights or Autopan, Random Pan. Rx400P AC output, Pan/Tilt/Zoom/Focus/Iris, Wash, Wipe, Lights, Autopan, 16 presets, Preset patrol Rx45X Advanced Telemetry Receiver fixed speed AC P/T head. 16 presets, 8 alarm inputs, OSD programming menu. Remote gain control. Selectable between 230Vac or 110Vac supply. 12Vdc 500mA camera supply output. Links selectable mains or 24Vac output. Wash, Wipe, Lights and Autopan outputs. Rx55X As Rx45X to drive 24Vdc high/variable speed P/T head. Wash, Wipe and Lights outputs. RS485 to Dome Rx10X Per Dome Coax from Dome RG59 <250M CT125 <500M Edgeport/1 USB Converter CTI16 16 Camera Coax Telemetry Interface RL HT OI X BBV Intellex Kit CTI16 Manual V15.4 April 2014 Page 13/20

DVX to CTI/16 driving Rx10X PC with DVX Viwer LAN IP SWITCH LAN Rx10X Rx10X to Dome Max Distance 5mtrs DVX Max Distance Coax RG59=250mtrs CT125=500mtrs VCL Dome Pelco D 2400 N 8 1 RS422 Simplex Pelco D 2400 E 8 1 RS422 Simplex Twisted Pair RS422 Simplex CTI/16 Coax CTI16 Manual V15.4 April 2014 Page 14/20

VIC MATRIX CTROLLING CTI16 WITH 360 VISI DOMES Coax Distance 250M RG59 500M CT125 VIC SIMPLEX COAX VIC KEYBOARD NETWK CTI16 Manual V15.4 April 2014 Page 15/20

2060 Dennard Domes with up the coax control and 4 local alarms Rx10X/WBX 250M RG59 / 500M CT125 RS422 9 10 11 12 13 14 15 16 B-BUS PT BBV SUPPLY LY 9VDC 500mA MAX CTI16 control to Domes BiPHASE RS232 kit LTC8780/50 CTI16 Manual V15.4 April 2014 Page 16/20

Philips Bi-Phase Matrix to CTI/16 driving Rx55X Bi-Phase Coax Bi-Phase Rx55X Multiple protocol telemetry receiver Philips G3 Dome Coax RS232 Philips Bi-Phase Matrix X T X RS232 kit R Max Distance Coax RG59=250m CT125=500m CTI/16 RS422 SIMPLEX Philips Kbd Coax CTI16 Manual V15.4 April 2014 Page 17/20

13 12 12 Control Location Up to 250m RG59 Up to 500m CT125 Camera Location BBV CTI/16 NOT USED GND NOT USED GND NOT USED ANGE NOT USED Pins Facing away from you DATA + DATA - GREEN RED YELLOW BLACK WHITE BROWN BLUE BBV VA1 X DATA - n X DATA + n B DATA - n BBV Rx10X GND. B DATA + n CAMERAS VCL MAXCOM8 11 10 9 8 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 ALARM INPUTS Twisted Pair Plug 1 MIT TWISTED PAIR 12V DC RS232 KBD1 PA7020C 20" C o lo r M o n ito r CTI16 Manual V15.4 April 2014 Page 18/20

CTI16 Manual V15.4 April 2014 Page 19/20

Extend your BBV Warranty from 12 months to 3 years As of the 1 st September 2008 BBV have offered our customers the opportunity to extend the standard 12 month warranty to 3 years. You must register for the extended warranty within 12 months of the date of manufacture. How to register for the 3 year warranty Registering for the new, longer 3 year warranty term is quick and easy. Either: Complete the warranty application card that comes in the box with your BBV product, and return it FREEPOST to BBV: BBV 3 Year Warranty If this card is returned with the serial number of the product and the Installation company details BBV will extend the warranty period from 12 Months to 36 Months. Number of Units, Start Serial No. Final Serial No. Contact Name. Company Name. Please could you send me information Phone Number. especially on: Site Name. Rx100s Address 1. Rx45x & Rx55x Address 2. FBM Video Matrices Address 3. Tx1500 Video Matrices Post Code. Starcard & Starcard Converters e-mail address. BBV Quad Do you read. Pick A Point I do not require any other further product information, Please refer to WWW.BBVCCTV.COM for terms, conditions & exclusions VAT Reg. No. 621758439 Registered in England No. 2852921 Registered office: 17 Apex Park Diplocks Way Hailsham East Sussex UK BN27 3JU Or alternatively: Register online at: www.bbvcctv.com Simply enter your details on the Warranty Cover page. CTI16 Manual V15.4 April 2014 Page 20/20