Trusted TMR I/O SmartSlot Slot Cables

Similar documents
Trusted 40 Channel Analogue Input FTA

Trusted 40 Channel 120 Vac Digital Input FTA

Trusted 40 Channel 120 Vac Digital Input FTA

Backlight Replacement

Industrial Monitor Update Kit

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Amplified TV Antenna VIDEO. Band Separator. Matching Transformer. 120 VAC, 60 Hz to 12 VDC, 200mA Wall Adapter ANT200

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

User Guide. HDMI Fiber Optic Extender. DVI-7350a

Model /29S RF Splitter

QDA4-44 RF Amp/Combiner

Model Camera System (CCTV) User Manual

Active UTP Transceiver Hub Installation Guide

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

SATRI AMPLIFIER AMP-51R. Owner s Manual

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Instructions. P MHz 1X/10X Passive Probe

GuardPLC Certified Function Blocks -- Basic Suite

Spectra Batten (Order code: LEDJ95)

SLC Channel Thermocouple/mV Input Module

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

QCA9-33 Active Combiner

SignalOn Series. L-Band Splitter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

llen-bradley 194R-HM4-NFPA3

32 Channel CPCI Board User Manual


TVAC20000 User manual

CU103 User Manual. Contents

The tracer - A dual range tester for semiconductors and other components.

9" B/W MONITOR CEM-09/09A-2 12" B/W MONITOR CEM-12/12A-2 OPERATION MANUAL

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Model 1421 Distribution Amplifier

SDP-RFD AC-3 /RF DEMODULATOR (120V/230V) INSTALLATION/ TECHNICAL MANUAL

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Stratos Duo RGB. User Manual. Order code: EQLED371

Traditional RF Splitter/Combiner and Directional Coupler User Manual

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

Signalling Cable Equivalent Sizes

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

SQM40/41 Actuators for air and gas dampers

Traditional RF Splitter/Combiner and Directional Coupler User Manual

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Installation Guide VL-MV10. Model No.

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

Assembly Instructions

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

PROFESSIONAL 2 CHANNEL SOLID-STATE MIC / LINE PREAMPLIFIER USER S MANUAL

INSTRUCTION MANUAL. ANI-1x2COMPDA. 1x2 Component Video(RCA) Splitter Distribution Amplifier w/ Digital Coaxial/Optical Audio

Power Injector 1520 Series

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

BNC-2090A QUICK START GUIDE. Rack-Mount Connector Accessory for E/M Series DAQ Devices

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

SW 50. Powered Subwoofer with Built-in Stereo Crossover

Telemetry Receiver Installation Guide

Identification - electrical services

Active UTP Transceiver Hub

KODAK Video Monitor CFH-V10

MS2540 Current Loop Receiver with RS485 Communication

Monochrome Video Monitors

TeamWork Installation Guide

.Power Distribution Center. PD-1. Instruction Manual

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

Fusion 120 Zoom. User Manual. Order code: EQLED068

HD Digital MPEG2 Encoder / QAM Modulator

1 Channel VGA Over Fiber Transmitter and Receiver Extender. User Manual L-1VGA-FE

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

HD Digital MPEG2 Encoder / QAM Modulator

TP HDMI OVER ANYWIRE TRANSMITTER

ORDER CODE: EQLED65 USER MANUAL

Document Part Number: Copyright 2010, Corelis Inc.

SAFETY INFORMATION. 7. Do not force switched or external connections in any way. They should all connect easily, without needing to be forced.

FD Trinitron Colour Television

apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

SYNC/VIDEO, SYNC FOR MULTI-TASKER MATRIX SWITCHER USER S GUIDE

SC-C1M SiriusConnect TM Vehicle Tuner

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

OPERATING INSTRUCTIONS TOM-0431IP

4 Wiring Brochure Wiring and installation of specific control

LEGEND L6. # Designed and engineered in the U.K. 6 Modules Just 3U

HDBaseT Extender Set 100m User Guide

DMX Operator 192-channel lighting controller

TECHCONNECT OWNERS MANUAL

Model Number Structure

Operating Instructions Dimmer for V Incandescent Lamps

FB10000 Error Messages Troubleshooting

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

User Guide. HDMI Active Cable Extender. DVI-7370c

Colour Explosion Proof Video Camera USER MANUAL VID-C

Installation Guide. Cellular Plug-in for Inverters with SetApp. Version 1.1

apple Service Source Apple Studio Display 17" LCD (ADC) Updated 6 Decenber Apple Computer, Inc. All rights reserved.

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

Transcription:

PD-TC500 Trusted Trusted TMR I/O SmartSlot Slot Cables Product Overview This document provides detailed information for the types of Trusted input/output (I/O) Cables available within the SmartSlot group. These types of cable provide connection facilities between the Trusted analogue and digital input/output modules, and Trusted Field Termination Assemblies (FTAs) or Trusted Versatile Field Termination Assemblies (VFTAs) as required. Cables are also available with a flying lead at one end to allow connection to conditioned terminals. The types of Trusted I/O SmartSlot Cables currently available are listed in Table 1 on page 4. The cables are manufactured to user s requirements, therefore length and type of cable insulation must be specified. Length must be specified to the nearest 0.5 m in the format xmx, e.g. 2m0 for a cable length of 2.0 m. This detail must be added to the end of the part number. Note that some cable lengths are preferred options and may be easier to obtain; please refer to Rockwell Automation for details. The type of cable insulation forms part of the cable part number and is denoted by 01 for Poly-Vinyl-Chloride (PVC), or 02 for Low Smoke Low Halogen (LSLH). 02 is also flame retardant to IEC 60332-3 Cat A. Note also that 02 may be a preferred option. When ordering cables, it is recommended that the user supplies the details as shown in Table 1. The maximum recommended I/O cable length is 15 m. Cables longer than this may be specified if necessary but may suffer from voltage drop, offset, crosstalk and noise and will present materials handling problems. Internal cables are designed for cables where they are terminated in adjacent enclosures. If the cable needs to leave the enclosure environment, the external cable has more protection. Note that the external cables are not armoured and are not suitable for truly external use and must still be treated with care. These cables will need protection when drawn through a cable route, and should also not be pulled by the connector(s). They should enter cabinets through transit/compression blocks and cannot be glanded. The SmartSlot cables described in this document allow hot-swap modules to be sited in separated slots as required, linked with a SmartSlot jumper cable. For Companion Slot cables, allowing hot-swap modules to be sited in adjacent slots using a double width chassis socket, please refer to PD_TC200. Rockwell Automation Publication PD-TC500 Issue 14

Trusted This document describes cables for Triple Modular Redundant (TMR) modules (typically 40 channel). For dual modules (typically 60 channel), please refer to PD_TC600 (SmartSlot) and PD_TC700 (Companion Slot). For details of the TC-306, TC-308 and TC-310 jumper cables, please refer to PD_TC300. PD-TC500 Rockwell Automation Publication PD-TC500 Issue 14

Trusted TMR I/O SmartSlot Cables PREFACE PREFACE In no event will Rockwell Automation be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples given in this manual are included solely for illustrative purposes. Because of the many variables and requirements related to any particular installation, Rockwell Automation does not assume responsibility or reliability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, with respect to use of information, circuits, equipment, or software described in this manual. All trademarks are acknowledged. DISCLAIMER It is not intended that the information in this publication covers every possible detail about the construction, operation, or maintenance of a control system installation. You should also refer to your own local (or supplied) system safety manual, installation and operator/maintenance manuals. REVISION AND UPDATING POLICY This document is based on information available at the time of its publication. The document contents are subject to change from time to time. The latest versions of the manuals are available at the Rockwell Automation Literature Library under "Product Information" information "Critical Process Control & Safety Systems". TRUSTED RELEASE This technical manual applies to Trusted Release: 3.6.1. LATEST PRODUCT INFORMATION For the latest information about this product review the Product Notifications and Technical Notes issued by technical support. Product Notifications and product support are available at the Rockwell Automation Support Centre at http://rockwellautomation.custhelp.com At the Search Knowledgebase tab select the option "By Product" then scroll down and select the Trusted product. Some of the Answer ID s in the Knowledge Base require a TechConnect Support Contract. For more information about TechConnect Support Contract Access Level and Features please click on the following link: https://rockwellautomation.custhelp.com/app/answers/detail/a_id/50871 This will get you to the login page where you must enter your login details. Rockwell Automation Publication PD-TC500 Issue 14 i

PREFACE Trusted TMR I/O SmartSlot Cables IMPORTANT A login is required to access the link. If you do not have an account then you can create one using the "Sign Up" link at the top right of the web page. DOCUMENTATION FEEDBACK Your comments help us to write better user documentation. If you discover an error, or have a suggestion on how to make this publication better, send your comment to our technical support group at http://rockwellautomation.custhelp.com ii Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables PREFACE SCOPE This manual specifies the maintenance requirements and describes the procedures to assist troubleshooting and maintenance of a Trusted system. WHO SHOULD USE THIS MANUAL This manual is for plant maintenance personnel who are experienced in the operation and maintenance of electronic equipment and are trained to work with safety systems. SYMBOLS In this manual we will use these notices to tell you about safety considerations. SHOCK HAZARD: Identifies an electrical shock hazard. If a warning label is fitted, it can be on or inside the equipment. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which can cause injury or death, property damage or economic loss. ATTENTION: Identifies information about practices or circumstances that can cause injury or death. CAUTION: Identifies information about practices or circumstances that can cause property damage or economic loss. BURN HAZARD: Identifies where a surface can reach dangerous temperatures. If a warning label is fitted, it can be on or inside the equipment. This symbol identifies items which must be thought about and put in place when designing and assembling a Trusted controller for use in a Safety Instrumented Function (SIF). It appears extensively in the Trusted Safety Manual. IMPORTANT NOTE TIP Identifies information that is critical for successful application and understanding of the product. Provides key information about the product or service. Tips give helpful information about using or setting up the equipment. Rockwell Automation Publication PD-TC500 Issue 14 iii

PREFACE Trusted TMR I/O SmartSlot Cables WARNINGS AND CAUTIONS WARNING: EXPLOSION RISK Do not connect or disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations or equivalent AVERTISSEMENT - RISQUE D EXPLOSION Ne pas connecter ou déconnecter l équipement alors qu il est sous tension, sauf si l environnement est exempt de concentrations inflammables ou équivalente MAINTENANCE Maintenance must be carried out only by qualified personnel. Failure to follow these instructions may result in personal injury. CAUTION: RADIO FREQUENCY INTERFERENCE Most electronic equipment is influenced by Radio Frequency Interference. Caution should be exercised with regard to the use of portable communications equipment around such equipment. Signs should be posted in the vicinity of the equipment cautioning against the use of portable communications equipment. CAUTION: The module PCBs contains static sensitive components. Static handling precautions must be observed. DO NOT touch exposed connector pins or attempt to dismantle a module. iv Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables PREFACE ISSUE RECORD Issue Date Comments 7 Sep 05 Format 8 Aug 06 Free wire idents 9 Apr 07 Added TC-521 10 Sep 07 Corrections 11 Dec 07 Flame retardance 12 Aug 08 8424 cables 13 Apr 10 Fig 11 change 14 Apr 16 Rebranded, reformatted and corrected for typographical errors Rockwell Automation Publication PD-TC500 Issue 14 v

PREFACE Trusted TMR I/O SmartSlot Cables Page intentionally left blank vi Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables Table of Contents Table of Contents 1. SmartSlot Cable Types and Selection Guides... 3 2. I/O SmartSlot Cable Type TC-501... 7 3. I/O SmartSlot Cable Type TC-502... 9 4. I/O SmartSlot Cable Type TC-503... 11 5. I/O SmartSlot Cable Type TC-504... 13 6. I/O SmartSlot Cable Type TC-505... 15 7. I/O SmartSlot Cable Type TC-506... 17 8. I/O SmartSlot Cable Type TC-507... 19 9. I/O SmartSlot Cable Type TC-508... 21 10. I/O SmartSlot Cable Type TC-509... 23 11. I/O SmartSlot Cable Type TC-510... 25 12. I/O SmartSlot Cable Type TC-511... 27 13. I/O SmartSlot Cable Type TC-512... 29 14. I/O SmartSlot Cable Type TC-515... 31 15. I/O SmartSlot Cable Type TC-516... 33 16. I/O SmartSlot Cable Type TC-517... 35 17. I/O SmartSlot Cable Type TC-518... 37 18. I/O SmartSlot Cable Type TC-521... 39 19. I/O SmartSlot Cable Type TC-523... 41 Rockwell Automation Publication PD-TC500 Issue 14 1

Table of Contents Trusted TMR I/O SmartSlot Cables Page intentionally left blank 2 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 1. SmartSlot Cable Types and Selection Guides 1. SmartSlot Cable Types and Selection Guides The types of Trusted I/O SmartSlot Cables currently available are listed in Table 1 below Cable Type TC-501-01-xmx TC-501-02-xmx TC-502-01-xmx TC-502-02-xmx TC-503-01-xmx TC-503-02-xmx TC-504-01-xmx TC-504-02-xmx TC-505-01-xmx TC-505-02-xmx TC-506-01-xmx TC-506-02-xmx TC-507-01-xmx TC-507-02-xmx TC-508-01-xmx TC-508-02-xmx TC-509-01-xmx TC-509-02-xmx TC-510-01-xmx TC-510-02-xmx TC-511-01-xmx Description I/O SmartSlot V2 Internal 40 Channel Input to FTA I/O SmartSlot V2 Internal 40 Channel Input to FTA I/O SmartSlot V2 Internal 40 Channel Input to Flying Lead / Free Wire I/O SmartSlot V2 Internal 40 Channel Input to Flying Lead / Free Wire I/O SmartSlot V2 External 40 Channel Input to FTA I/O SmartSlot V2 External 40 Channel Input to FTA I/O SmartSlot V2 External 40 Channel Input to Flying Lead / Free Wire I/O SmartSlot V2 External 40 Channel Input to Flying Lead / Free Wire I/O SmartSlot V2 Internal 40 Channel Output to FTA I/O SmartSlot V2 Internal 40 Channel Output to FTA I/O SmartSlot V2 Internal 40 Channel Output to Flying Lead / Free Wire I/O SmartSlot V2 Internal 40 Channel Output to Flying Lead / Free Wire I/O SmartSlot V2 External 40 Channel Output to FTA I/O SmartSlot V2 External 40 Channel Output to FTA I/O SmartSlot V2 External 40 Channel Output to Flying Lead / Free Wire I/O SmartSlot V2 External 40 Channel Output to Flying Lead / Free Wire I/O SmartSlot V2 Internal 40 Channel Output to VFTA I/O SmartSlot V2 Internal 40 Channel Output to VFTA I/O SmartSlot V2 External 40 Channel Output to VFTA I/O SmartSlot V2 External 40 Channel Output to VFTA I/O SmartSlot V2 Internal 40 Channel Input to VFTA Rockwell Automation Publication PD-TC500 Issue 14 3

1. SmartSlot Cable Types and Selection Guides Trusted TMR I/O SmartSlot Cables Cable Type TC-511-02-xmx TC-512-01-xmx TC-512-02-xmx TC-515-01-xmx TC-515-02-xmx TC-516-01-xmx TC-516-02-xmx TC-517-01-xmx TC-517-02-xmx TC-518-01-xmx TC-518-02-xmx TC-521-01-xmx TC-521-02-xmx TC-523-0?-xmx Description I/O SmartSlot V2 Internal 40 Channel Input to VFTA I/O SmartSlot V2 External 40 Channel Input to VFTA I/O SmartSlot V2 External 40 Channel Input to VFTA I/O SmartSlot V2 Internal 40 Channel Output to FTA (Integral Power) I/O SmartSlot V2 Internal 40 Channel Output to FTA (Integral Power) I/O SmartSlot V2 Internal 40 Channel Output to Flying Lead / Free Wire (Integral Power) I/O SmartSlot V2 Internal 40 Channel Output to Flying Lead / Free Wire (Integral Power) I/O SmartSlot V2 External 40 Channel Output to FTA (Integral Power) I/O SmartSlot V2 External 40 Channel Output to FTA (Integral Power) I/O SmartSlot V2 External 40 Channel Output to Flying Lead / Free Wire (Integral Power) I/O SmartSlot V2 External 40 Channel Output to Flying Lead / Free Wire (Integral Power) I/O SmartSlot V2 Internal T8472 16 Channel Output to T8871 FTA I/O SmartSlot V2 Internal T8472 16 Channel Output to T8871 FTA I/O SmartSlot V2 Internal 40 Channel Input to T8824 VFTA Table 1 Trusted I/O SmartSlot Cables 4 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 1. SmartSlot Cable Types and Selection Guides FTA TC-501- INPUT VFTA TC-511- Flying Lead TC-502- SMARTSLOT OUTPUT FTA VFTA Flying Lead TC-505- TC-509- TC-506- INTERNAL Integral Power FTA Flying Lead FTA TC-515- TC-516- TC-201- INPUT VFTA TC-211- Flying Lead TC-202- COMPANION SLOT OUTPUT FTA VFTA Flying Lead TC-205- TC-209- TC-206- Integral Power FTA Flying Lead TC-215- TC-216- FTA TC-503- INPUT VFTA TC-512- Flying Lead TC-504- SMARTSLOT OUTPUT FTA VFTA Flying Lead TC-507- TC-510- TC-508- EXTERNAL Integral Power FTA Flying Lead FTA TC-517- TC-518- TC-203- INPUT VFTA TC-212- Flying Lead TC-204- COMPANION SLOT OUTPUT FTA VFTA Flying Lead TC-207- TC-210- TC-208- Integral Power FTA Flying Lead TC-217- TC-218- Table 2 TMR 40 Channel Standard Cable Selection Guide Rockwell Automation Publication PD-TC500 Issue 14 5

1. SmartSlot Cable Types and Selection Guides Trusted TMR I/O SmartSlot Cables INTERNAL EXTERNAL SMARTSLOT INPUT FTA TC-601-02 COMPANION SLOT INPUT FTA TC-701-02 SMARTSLOT INPUT FTA TC-603-02 COMPANION SLOT INPUT FTA TC-703-02 Table 3 Dual 60 Channel Standard Cable Selection Guide The various types of I/O SmartSlot Cables, i.e. TC-501, TC-502 etc. are described separately in the following sections. 6 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 2. I/O SmartSlot Cable Type TC-501 2. I/O SmartSlot Cable Type TC-501 This type of cable, and the modules/ftas it is used with, is shown in Figure 1 below. Module T8403 T8423 T8431 FTA T8800 T8801 T8821 T8830/1 Figure 1 I/O SmartSlot Cable Type TC-501 This type of Trusted I/O SmartSlot Cable is designed for use with analogue or digital input modules and is suitable for connecting input signals from an internal FTA to the module. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (type TC-500). The other end of the cable is fitted with a 96-way type R connector housed in a single-width hood enabling the cable to be connected to an FTA. The multi-core cable is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication PD-TC500 Issue 14 7

2. I/O SmartSlot Cable Type TC-501 Trusted TMR I/O SmartSlot Cables Page intentionally left blank 8 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 3. I/O SmartSlot Cable Type TC-502 3. I/O SmartSlot Cable Type TC-502 This type of cable, and the modules it is used with, is shown in Figure 2 below. Module T8403 T8423 T8431 Figure 2 I/O SmartSlot Cable Type TC-502 This type of Trusted I/O SmartSlot Cable is designed for use with analogue or digital input modules and is suitable for connecting input signals from internal terminals to the module. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (type TC-500). The other end of the cable is left as a flying lead enabling the cable to be terminated as required, e.g. connected to conditioned field terminals. The flying leads are sleeved with identity ferrules marked CH1, CH2, CH3 etc. for channel terminations or 0 V for group reference terminations. The multi-core cable is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication PD-TC500 Issue 14 9

3. I/O SmartSlot Cable Type TC-502 Trusted TMR I/O SmartSlot Cables Page intentionally left blank 10 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 4. I/O SmartSlot Cable Type TC-503 4. I/O SmartSlot Cable Type TC-503 This type of cable, and the modules/ftas it is used with, is shown in Figure 3 below. Module T8403 T8423 T8431 FTA T8800 T8801 T8821 T8830/1 Figure 3 I/O SmartSlot Cable Type TC-503 This type of Trusted I/O SmartSlot Cable is designed for use with analogue or digital input modules and is suitable for connecting input signals from a remote FTA to the module. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of the cable is fitted with a 96-way type R connector housed in a single-width hood enabling the cable to be connected to an FTA. The multi-core cable is stripped back 2.0 m at the chassis end and 1.5 m at the FTA end. Both ends are then shrouded in nylon Rilgain sheathing. The Rilgain sheathing is cut with a heat gun to prevent fraying. Joints between the Rilgain sheathing and the multi-core outer sheath are taped over with 25 mm PVC insulating tape and then covered with heatshrink sleeving. At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication PD-TC500 Issue 14 11

4. I/O SmartSlot Cable Type TC-503 Trusted TMR I/O SmartSlot Cables Page intentionally left blank 12 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 5. I/O SmartSlot Cable Type TC-504 5. I/O SmartSlot Cable Type TC-504 This type of cable, and the modules it is used with, is shown in Figure 4 below. Module T8403 T8423 T8431 Figure 4 I/O SmartSlot Cable Type TC-504 This type of Trusted I/O SmartSlot Cable is designed for use with analogue or digital input modules and is suitable for connecting input signals from external terminals to the module. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of the cable is left as a flying lead enabling the cable to be terminated as required, e.g. connected to conditioned field terminals. The flying leads are sleeved with identity ferrules marked CH1, CH2, CH3 etc. for channel terminations or 0 V for group reference terminations. The multi-core cable is stripped back 2.0 m at both ends, then shrouded in nylon Rilgain sheathing. The Rilgain sheathing is cut with a heat gun to prevent fraying. Joints between the Rilgain sheathing and the multi-core outer sheath are taped over with 25 mm PVC insulating tape and then covered with heatshrink sleeving. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication PD-TC500 Issue 14 13

5. I/O SmartSlot Cable Type TC-504 Trusted TMR I/O SmartSlot Cables Page intentionally left blank 14 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 6. I/O SmartSlot Cable Type TC-505 6. I/O SmartSlot Cable Type TC-505 This type of cable, and the modules/ftas it is used with, is shown in Figure 5 below. Module T8444 T8451 T8461 T8471 T8480 FTA T8850 T8870 Figure 5 I/O SmartSlot Cable Type TC-505 This type of Trusted I/O SmartSlot Cable is designed for use with digital 24 V/120 Vdc or analogue output modules and is suitable for connecting output signals from the module to an internal FTA. Three multi-core cables are used for this application. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The non-chassis end of multi-core 1 is fitted with a 96-way type R connector housed in a single-width hood enabling connection to an FTA. The non-chassis end of multi-core 2 is fitted with a 5-way Weidmuller BLZF 3.5 series connector enabling the cable to be terminated at a T8290 Output Power Distribution Unit. This cable is used for field power return. The non-chassis end of multi-core 3 is fitted with a 6-way AMP plug used to connect power to the field from a T8290 or T8297 and is made up of five individual 2.5 mm wires contained within Rilgain sleeving. The 0 V connection at the chassis end allows a module reference so that it can measure its output voltage, this must be connected to the field 0 Volts. The FTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection between this field supply and the T8290 Output power distribution unit (TB1 pins 1 and 2). Rockwell Automation Publication PD-TC500 Issue 14 15

6. I/O SmartSlot Cable Type TC-505 Trusted TMR I/O SmartSlot Cables Multi-core 1 is stripped back 1.5 m at both ends. Multi-cores 1, 2 and 3 are shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated, or over sleeved as required to prevent fraying. At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 16 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 7. I/O SmartSlot Cable Type TC-506 7. I/O SmartSlot Cable Type TC-506 This type of cable, and the modules it is used with, is shown in Figure 6 below. Module T8444 T8448 T8449 T8451 T8461 T8471 T8480 Figure 6 I/O SmartSlot Cable Type TC-506 This type of Trusted I/O SmartSlot Cable is designed for use with digital 24 V/120 Vdc or analogue output modules and is suitable for connecting output signals from the module to internal terminals. Two multi-core cables are required for this application. The chassis end of the multi-core 1 is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of multi-core 1 is left as a flying lead enabling the cable to be terminated as required, e.g. connected to conditioned field terminals. The non-chassis end of multi-core 2 is fitted with a 6-way AMP plug used to connect power to the field from a T8290 or T8297 and is made up of five individual 2.5 mm wires contained within Rilgain sleeving. The flying leads are sleeved with identity ferrules marked CH1, CH2, CH3 etc. for channel terminations or V FIELD RTNGRP1 to V FIELD RTNGRP5 for group reference terminations. The 0 V connections at the flying leads end allows a module reference so that it can measure its output voltage, these must be connected to the field 0 Volts. Rockwell Automation Publication PD-TC500 Issue 14 17

7. I/O SmartSlot Cable Type TC-506 Trusted TMR I/O SmartSlot Cables The flying lead multi-core contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. Multi-core 1 is stripped back 1.5 m at both ends. Multi-cores 1 and 2 are shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated, or over sleeved as required to prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 18 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 8. I/O SmartSlot Cable Type TC-507 8. I/O SmartSlot Cable Type TC-507 This type of cable, and the modules/ftas it is used with, is shown in Figure 7 below. Module T8444 T8451 T8461 T8471 T8480 FTA T8850 T8870 Figure 7 I/O SmartSlot Cable Type TC-507 This type of Trusted I/O SmartSlot Cable is designed for use with digital 24 V/120 Vdc or analogue output modules and is suitable for connecting output signals from the module to an external FTA. Three multi-core cables are used for this application. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The non-chassis end of multi-core 1 is fitted with a 96-way type R connector housed in a single-width hood enabling connection to an FTA. The non-chassis end of multi-core 2 is fitted with a 5-way Weidmuller BLZF 3.5 series connector enabling the cable to be terminated at a T8290 Output Power Distribution Unit. This cable is used for field power return. The non-chassis end of multi-core 3 is fitted with a 6-way AMP plug used to connect power to the field from a T8290 or T8297 and is made up of five individual 2.5 mm wires contained within Rilgain sleeving. The 0 V connection at the chassis end allows a module reference so that it can measure its output voltage, this must be connected to the field 0 Volts. The FTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection between this field supply and the T8290 Output power distribution unit (TB1 pins 1 and 2). Rockwell Automation Publication PD-TC500 Issue 14 19

8. I/O SmartSlot Cable Type TC-507 Trusted TMR I/O SmartSlot Cables Multi-core 1 is stripped back 1.5 m at both ends. Multi-cores 1, 2 and 3 are shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated, or over sleeved as required to prevent fraying. At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 20 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 9. I/O SmartSlot Cable Type TC-508 9. I/O SmartSlot Cable Type TC-508 This type of cable, and the modules it is used with, is shown in Figure 8 below. Module T8444 T8448 T8449 T8451 T8461 T8471 T8480 Figure 8 I/O SmartSlot Cable Type TC-508 This type of Trusted I/O SmartSlot Cable is designed for use with digital 24 V/120 Vdc or analogue output modules and is suitable for connecting output signals from the module to external terminals. Two multi-core cables are required for this application. The chassis end of the multi-core 1 is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of multi-core 1 is left as a flying lead enabling the cable to be terminated as required, e.g. connected to conditioned field terminals. The non-chassis end of multi-core 2 is fitted with a 6-way AMP plug used to connect power to the field from a T8290 or T8297 and is made up of five individual 2.5 mm wires contained within Rilgain sleeving. The flying leads are sleeved with identity ferrules marked CH1, CH2, CH3 etc. for channel terminations or V FIELD RTNGRP1 to V FIELD RTNGRP5 for group reference terminations. The 0 V connections at the flying leads end allows a module reference so that it can measure its output voltage, these must be connected to the field 0 Volts. Rockwell Automation Publication PD-TC500 Issue 14 21

9. I/O SmartSlot Cable Type TC-508 Trusted TMR I/O SmartSlot Cables The flying lead multi-core contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. Multi-core 1 is stripped back 1.5 m at both ends. Multi-cores 1 and 2 are shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated, or over sleeved as required to prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 22 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 10. I/O SmartSlot Cable Type TC-509 10. I/O SmartSlot Cable Type TC-509 This type of cable, and the modules/vftas it is used with, is shown in Figure 9 below. Module T8444 T8448 T8449 T8451 T8461 T8471 T8480 VFTA T8842 T8845 Figure 9 I/O SmartSlot Cable Type TC-509 This type of Trusted I/O SmartSlot Cable is designed for use with digital 24 V/120 Vdc and analogue output modules and is suitable for connecting output signals from the module to an internal VFTA. For the T8448 and T8449, it is recommended to use the T8842 VFTA. PD-T8842 describes the possible circuits that may be configured for this VFTA. Two multi-core cables are required for this application. The chassis end of the multi-core 1 is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of multi-core 1 is fitted with five 10-way Weidmuller BLZF 3.5 series connectors enabling the cable to be terminated at a VFTA. The non-chassis end of multi-core 2 is fitted with a 6-way AMP plug used to connect power to the field from a T8290 or T8297. This cable is made up of five individual 2.5 mm wires contained within Rilgain sleeving. For analogue output or low current digital output modules using this cable, the T8297 is recommended. The VFTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. Multi-core 1 is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. Multi-core 2 is shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. Rockwell Automation Publication PD-TC500 Issue 14 23

10. I/O SmartSlot Cable Type TC-509 Trusted TMR I/O SmartSlot Cables At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 24 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 11. I/O SmartSlot Cable Type TC-510 11. I/O SmartSlot Cable Type TC-510 This type of cable, and the modules/vftas it is used with, is shown in Figure 10 below. Module T8444 T8448 T8449 T8451 T8461 T8471 T8480 VFTA T8842 T8845 Figure 10 I/O SmartSlot Cable Type TC-510 This type of Trusted I/O SmartSlot Cable is designed for use with digital 24 V/120 Vdc and analogue output modules and is suitable for connecting output signals from the module to an external VFTA. For the T8448 and T8449, it is recommended to use the T8842 VFTA. PD-T8842 describes the possible circuits that may be configured for this VFTA. Two multi-core cables are required for this application. The chassis end of the multi-core 1 is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of multi-core 1 is fitted with five 10-way Weidmuller BLZF 3.5 series connectors enabling the cable to be terminated at a VFTA. The non-chassis end of multi-core 2 is fitted with a 6-way AMP plug used to connect power to the field from a T8290 or T8297. This cable is made up of five individual 2.5 mm wires contained within Rilgain sleeving. For analogue output or low current digital output modules using this cable, the T8297 is recommended. The VFTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. Multi-core 1 is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. Multi-core 2 is shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. Rockwell Automation Publication PD-TC500 Issue 14 25

11. I/O SmartSlot Cable Type TC-510 Trusted TMR I/O SmartSlot Cables At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 26 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 12. I/O SmartSlot Cable Type TC-511 12. I/O SmartSlot Cable Type TC-511 This type of cable, and the modules/vftas it is used with, is shown in Figure 11 below. Module T8403 T8423 T8431 VFTA T8842 Figure 11 I/O SmartSlot Cable Type TC-511 This type of Trusted I/O SmartSlot Cable is designed for use with analogue or digital input modules and is suitable for connecting input signals from an internal VFTA to the module. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of the multi-core is fitted with one 7-way and five 10-way Weidmuller BLZF 3.5 series connectors enabling the cable to be terminated at a VFTA. The VFTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. The multi-core is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication PD-TC500 Issue 14 27

12. I/O SmartSlot Cable Type TC-511 Trusted TMR I/O SmartSlot Cables Page intentionally left blank 28 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 13. I/O SmartSlot Cable Type TC-512 13. I/O SmartSlot Cable Type TC-512 This type of cable, and the modules/vftas it is used with, is shown in Figure 12 below. Module T8403 T8423 T8431 VFTA T8842 Figure 12 I/O SmartSlot Cable Type TC-512 This type of Trusted I/O SmartSlot Cable is designed for use with analogue or digital input modules and is suitable for connecting input signals from an external VFTA to the module. The chassis end of the multi core cable is fitted with a 96 way type C connector housed in a single width hood (TC-500). The other end of the multi core is fitted with one 7-way and five 10-way Weidmuller BLZF 3.5 series connectors enabling the cable to be terminated at a VFTA. The VFTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. The multi core is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication PD-TC500 Issue 14 29

13. I/O SmartSlot Cable Type TC-512 Trusted TMR I/O SmartSlot Cables Page intentionally left blank 30 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 14. I/O SmartSlot Cable Type TC-515 14. I/O SmartSlot Cable Type TC-515 This type of cable, and the modules/ftas it is used with, is shown in Figure 12 below. Module T8451 T8471 T8461 T8480 FTA T8850 T8870 Figure 12 I/O SmartSlot Cable Type TC-515 This type of Trusted I/O SmartSlot Cable is designed for use with 24 V or 120 Vdc digital output modules and is suitable for connecting output signals from the module to an internal FTA. Power connections are integral with this type of cable. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of the cable is fitted with a 96-way type R connector housed in a single-width hood enabling the cable to be connected to an FTA. Using this cable, the field power is connected at the FTA, which has indicators for each power group which are voltage sensitive. For this reason, the T8850 FTA should be used with the T8451 and the T8870 with the T8471. The 0 V connection at the FTA end allows a module reference so that it can measure its output voltage, this must be connected to the field 0 Volts. The FTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. The multi-core cable is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. Rockwell Automation Publication PD-TC500 Issue 14 31

14. I/O SmartSlot Cable Type TC-515 Trusted TMR I/O SmartSlot Cables At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 32 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 15. I/O SmartSlot Cable Type TC-516 15. I/O SmartSlot Cable Type TC-516 This type of cable, and the modules it is used with, is shown in Figure 13 below. Module T8444 T8448 T8449 T8451 T8461 T8471 T8480 Figure 13 I/O SmartSlot Cable Type TC-516 This type of Trusted I/O SmartSlot Cable is designed for use with digital and analogue output modules and is suitable for connecting output signals from the module to internal terminals. Power connections are integral with this type of cable. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of the cable is left as a flying lead enabling the cable to be terminated as required, e.g. connected to conditioned field terminals. The flying leads are sleeved with identity ferrules marked CH1, CH2, CH3 etc. for channel terminations or V FIELD GRP1 to V FIELD GRP5 for group field supply terminations or V FIELD RTNGRP1 to V FIELD RTNGRP5 for group reference terminations. The 0 V connections at the flying lead ends allows a module reference so that it can measure its output voltage, this must be connected to the field 0 Volts. The flying lead multi-core contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. Rockwell Automation Publication PD-TC500 Issue 14 33

15. I/O SmartSlot Cable Type TC-516 Trusted TMR I/O SmartSlot Cables The multi-core cable is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 34 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 16. I/O SmartSlot Cable Type TC-517 16. I/O SmartSlot Cable Type TC-517 This type of cable, and the modules/ftas it is used with, is shown in Figure 14 below. Module T8451 T8471 T8461 T8480 FTA T8850 T8870 Figure 14 I/O SmartSlot Cable Type TC-517 This type of Trusted I/O SmartSlot Cable is designed for use with 24 V or 120 Vdc digital output modules and is suitable for connecting output signals from the module to an internal FTA. Power connections are integral with this type of cable. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of the cable is fitted with a 96-way type R connector housed in a single-width hood enabling the cable to be connected to an FTA. Using this cable, the field power is connected at the FTA, which has indicators for each power group which are voltage sensitive. For this reason, the T8850 FTA should be used with the T8451 and the T8870 with the T8471. The 0 V connection at the FTA end allows a module reference so that it can measure its output voltage, this must be connected to the field 0 Volts. The FTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. The multi-core cable is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. Rockwell Automation Publication PD-TC500 Issue 14 35

16. I/O SmartSlot Cable Type TC-517 Trusted TMR I/O SmartSlot Cables At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 36 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 17. I/O SmartSlot Cable Type TC-518 17. I/O SmartSlot Cable Type TC-518 This type of cable, and the modules it is used with, is shown in Figure 15 below. Module T8444 T8448 T8449 T8451 T8461 T8471 T8480 Figure 15 I/O SmartSlot Cable Type TC-518 This type of Trusted I/O SmartSlot Cable is designed for use with digital and analogue output modules and is suitable for connecting output signals from the module to external terminals. Power connections are integral with this type of cable. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of the cable is left as a flying lead enabling the cable to be terminated as required, e.g. connected to conditioned field terminals. The flying leads are sleeved with identity ferrules marked CH1, CH2, CH3 etc. for channel terminations or V FIELD GRP1 to V FIELD GRP5 for group field supply terminations or V FIELD RTNGRP1 to V FIELD RTNGRP5 for group reference terminations. The 0 V connections at the flying lead ends allows a module reference so that it can measure its output voltage, this must be connected to the field 0 Volts. The flying lead multi-core contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. Rockwell Automation Publication PD-TC500 Issue 14 37

17. I/O SmartSlot Cable Type TC-518 Trusted TMR I/O SmartSlot Cables The multi-core cable is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. 38 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 18. I/O SmartSlot Cable Type TC-521 18. I/O SmartSlot Cable Type TC-521 This type of cable, and the modules/fta it is used with, is shown in Figure 16 below. Module T8472 FTA T8871 Figure 16 I/O SmartSlot Cable Type TC-521 This type of Trusted I/O SmartSlot Slot Cable is designed for use with the T8472 120 Vac digital output module only and is suitable for connecting output signals from the module to an internal T8871 FTA. Power connections are integral with this type of cable. The chassis end of the multi-core cable is fitted with a 32-way type D connector housed in a single-width hood (TC-500). The other end of the cable is fitted with two 8-way and two 5-way Weidmuller BLZF 5 series connectors enabling the cable to be terminated at an T8871 FTA. Both ends are fitted with screw retention. The two 5-way connectors carry AC field power on three of the terminals, which is supplied to the FTA via screw terminals. Each connector powers one group of eight terminals. The AC power cables may also be stripped out of the multi-core sheath and terminated at an AC marshalling panel elsewhere. The multi-core cable is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. Rockwell Automation Publication PD-TC500 Issue 14 39

18. I/O SmartSlot Cable Type TC-521 Trusted TMR I/O SmartSlot Cables Page intentionally left blank 40 Issue 14 Rockwell Automation Publication PD-TC500

Trusted TMR I/O SmartSlot Cables 19. I/O SmartSlot Cable Type TC-523 19. I/O SmartSlot Cable Type TC-523 This type of cable, and the modules/vftas it is used with, is shown in Figure 17 below. Module T8424 VFTA T8824 Figure 17 I/O SmartSlot Cable Type TC-523 This type of Trusted I/O SmartSlot Cable is designed for use with T8424 120 Vac digital input modules and is suitable for connecting input signals from an internal VFTA to the module. Note that the T8424 should only be paired with a T8824 FTA. The chassis end of the multi-core cable is fitted with a 96-way type C connector housed in a single-width hood (TC-500). The other end of the multi-core is fitted with five 10-way screw-retained connectors enabling the cable to be terminated at a T8824 VFTA. The multi-core is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication PD-TC500 Issue 14 41