INSTRUCTION MANUAL. FiberSaver Series, FS-6000, FS-12000, FS-18000

Similar documents
SilverBULLET 3G Series

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES

INSTRUCTION MANUAL VF MultiDyne. Harnessing The Power of Light

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

FIBER FIRST. opengear OG3600 Series. Fiber Transport Cards User Manual. Fiber Optic Solutions. Creating Broadcast & Cinema Equipment since 1977

3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

3GHD-EO-SFP. User manual. SD/HD/3G-SDI electrical to optical converter with SFP. Rev. A

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

MULTIDYNE Electronics, Inc. Innovations in Television Testing & distribution

Mini HD-SDI Optical Transceiver Model No : VCF-MF01TXRX

CWDM / 12 Gb/s Medium Power SM Video Digital Diagnostic SFP+ Transceiver

IQOTXS Dual-Channel Single-Mode Fibre Optic Transmitter for SDI

FiberLink 3500 Series Transceivers

FiberLink 3350 Series

Analog HD video over fiber converters for smart HD CCTV

8Ch CWDM 3G-SDI Fiber Extender kit User Manual L-XSDI-CWDM-3G-TX/RX

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

3GHD-EO-2-SFP. User manual. Dual SD/HD/3G-SDI electrical to optical converter with SFP. Rev. C

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

IQOTXD Dual-Channel Multimode Fibre Optic Transmitter for SDI

I N S T R U C T I O N D A T A

IQORXD Dual-Channel Multimode Fibre Optic Receiver for SDI

FiberLink 3355 Series

3Gb/s, HD and SD and ASI/DVB and SMPTE-310M 8x8 video router ALL RIGHTS RESERVED

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

12G/6G/3G/HD/SD-SDI over Single mode SFP-type Fiber Optic Extender Immune to Pathological. User Manual. rev: Made in Taiwan

MODEL NVISION 8500 NVISION 8500 ENTERPRISE CLASS ROUTERS. New Fiber Connectivity and Hybrid cards for disembedding/embedding digtal audio.

Datasheet Sirius 800 AHP Advanced Hybrid Processing and MV-800 Integrated Multiviewer

3G fiber. TL7075/76 Optical 3Gbit/s Link solution with full duplex Communication Channel. TL Features. TL Features

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

CWDM / 3 Gb/s Medium Power SM Video Digital Diagnostic SFP Transceiver

E3/DS3 Fibre Extender

Doteck 4K Series. 6G-SDI UHD Video fiber optic Transmission System

ECT5484. Fiber Optic Digital Video, Audio & Data Multiplexer/Demultiplexer. Single Fiber Operation. Specifications

6G-SDI. Digital Video fiber. optic Transmission System

FOM-9010, FOM-9011 and FOM-9012

Sirius 800 with Advanced Hybrid Processing

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

Power (dbm) λ (nm) LINK DISTANCE SDI Bit Rate Max. Link Distance (km) 3G-SDI 2.97Gbps 30 HD-SDI 1.485Gbps 30 SD-SDI 270Mbps 30

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

2015 OPTICAL TRANSMITTERS

VersiVision. FVTM2BBxA / FVRM2BBxA 2-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 2-CHANNELS BI-DIRECTIONAL AUDIO

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

1550 nm TX / 1310 nm RX / 3 Gb/s Medium Power 1-Fibre SM Video SFP Transceiver

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

16 SFP ports and 16 BNC. built in. 24 SFP ports, 8 BNC

Dual HD-SDI Electrical to Optical Converter

Multi Rate Transponder and Converter for 1330 /1550nm and Coarse Wavelength Division Multiplexing. Flashlink User Manual

CWDM / 3 Gb/s Medium Power Optical SM Digital Diagnostic Transmitter/Receiver FVD2-1TR-SM30-XX

3GHD-OE 3GHD-OE-2. User manual. Single and dual 3G-SDI optical to electrical converter. Rev. F

Specifications PowerCage 1600 System

LONWORKS Fibre Optic Converter

Ponderosa is expandable by 8 input and/or 8 output increments up to 64x64 in a 4RU frame. Typical Configurations:

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

Chapter 10. SDI & HD-SDI SWITCHERS MSW 4V SDI rs Four Input SDI Video Switcher SW4 3G HD-SDI Four Input Multi-Rate SDI Switcher...

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

User Instruction Manual IQSDA30/IQSDA32. Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution Amplifiers. snellgroup.

4 Channel HD SDI Over Fiber Transmitter and Reciever Extender with RS 485 Channel User Manual L-4SDI-FE-HD-TX/RX

3GHD-EO-D15xx. User manual

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

opengear OPG-1L 50 MHz-2.3 GHz

High Performance fibre systems

Specification. Small Form Factor Pluggable Transceiver (MSA) LC Receptacle SFP+ 12 Gigabit SDI TIM-A1CB1-F11

Aegis Electronic Group

3353 Series. Fiberlink. 3G/HD/SD-SDI to HDMI Optical Receiver. User s Manual. Communications Specialties Fiberlink 3353

NVISION Compact Space and cost efficient utility routers

COE Group plc. Contents

OmniStar GX2 Headend Optics Platform

User Instruction Manual IQOTR31. 3G/HD/SD-SDI Single Mode Fiber Optic Transceiver. snellgroup.com

Truck router (3Gbps/HD/SD/ASI)

UTAH 100/UDS Universal Distribution System

3Gb/s, HD and SD and ASI/DVB and SMPTE-310M 8x8 router and master cross-point board ALL RIGHTS RESERVED

SWITCHING, ROUTING & DISTRIBUTION

KRAMER ELECTRONICS LTD. USER MANUAL MODELS: 690T SDI Fiber Optic Transmitter 690R SDI Fiber Optic Receiver. P/N: Rev 2

1550 nm / 3 Gb/s Medium Power Single Optical SM Digital Diagnostic Transmitter FVD2-1TR-SM50

C Module Description

VCF-HCFB01TXRX SD/HD/3G-SDI Optical Transceiver with Independence audio

VersiVision. FVTMHA0xA / FVRMHA0xA 16-CHANNEL DIGITALLY ENCODED VIDEO 1-CHANNEL BI-DIRECTIONAL DATA MULTIPLEXER USER S MANUAL.

ED5229GT-E Series. Page 1 of 8

LONWORKS Fibre Optic Router

4-channel HDMI Network Extender

Product Catalog. Cheetah Series Routing Switchers. Routing Switchers for SD/HD/3G-SDI 64X64 up to 1024X1024 in 12 chassis sizes for fiber or coax

OTX Optical Transmitter. Operation Instructions

Dual HD-SDI Output (MCX + BNC connector) HD- SDI Cable Driver. HDMI DVI Tx connector. Optical HD- SDI Output LC - connector. 8pin

Specifications SMX System MultiMatrix Switchers

FiberLink 7142 Series

3G-SDI Video SFP CWDM nm 40km Optical Transceivers

EVLA Fiber Selection Critical Design Review

10Gbps SFP+ Optical Transceiver, 10km Reach

FIM-108 MATRIX FIBER INTERFACE INSTRUCTION MANUAL

QFMN. QFMN Fiber Mini Node Distribution Amplifier INSTALLATION & OPERATION MANUAL.

ED5229GT-E/GTRE Series

Fibre Optic Modem ODW-611

Features. CPU Version. Non-CPU Version

Transcription:

INSTRUCTION MANUAL FiberSaver Series, FS-6000, FS-12000, FS-18000 SERIAL DIGITAL FIBER OPTIC TRANSPORT and DISTRIBUTION SYSTEM FOR SMPTE 259, 292, 424, DVB-ASI and other protocols 110 Newton Place Hauppauge, NY 11788 (800)-488-8378 / (516)-671-7278 sales@multidyne.com www.multidyne.com FIBER FIRST

MULTIDYNE, the Multidyne logo, FS-6000, FS-12000 & FS-18000 are registered trademarks of MULTIDYNE Electronics, Inc. Copyright 2017 MULTIDYNE Electronics, Inc., Hauppauge, New York. Printed in the United States of America. All Rights Reserved. Contents of this publication may not be reproduced in any form without the written permission of MULTIDYNE Electronics, Inc. This product was designed and manufactured in the UNITED STATES of AMERICA. 2

Contents Introduction.......................................4 Features and Operation.................................4 Transmitter Front and Rear Panels............................ 5 Receiver Front and Rear Panels.............................5 Fig1. FS-6000, FS-12000, FS-18000.......................... 6 Power Requirements..................................7 Installation and Setup.................................. 7 Appendix A: Block Diagram...............................8 Appendix B: Technical Specifications.......................... 9 (continued)....................................... 9

Introduction The FiberSaver Series of fiber optic transmitters and receivers makes possible the combining of up to 18 optical signals onto one fiber using CWDM techniques for transmission up to 20km standard or the distance required, and the reassignment of such signals (remapping) onto different wavelengths if needed to suit customer needs. The units can accept signals in either optical or copper formats, and can output them in both formats simultaneously. Although designed for SMPTE 424,292, or 259 SDI ad DVB-ASI, the FiberSaver Series can be used with other protocols up to 3GBPS. Each of the 6 channels has a re-clocker that is bypassable for non- SMPTE signals. Each channel of the FiberSaver Series FTX will automatically switch to its BNC input if its optical input is not illuminated. It is also possible, upon special order, to have a mixture of transmit and receive channels at each end to support bidirectionality. For example, you could have 3 transmit and 3 receive channels at each end, or any other combination. Applications include transmission links for high definition or digital television studio to transmitter, studio-tostudio, or any other similar long-range situations. It can also combine and optically remap the outputs of other Multidyne products. The FiberSaver Series can be ordered as follows 1) FS-6000-6 channels in one fiber 2) FS-12000-12 channels in one fiber 3) FS-18000-18 channels in one fiber Features and Operation The following discussion assumes that we have a standard configuration consisting of 6 transmit channels at one end and 6 receive at the other end. A block diagram of the FS-6000 system is shown in Appendix A. Each end consists of 6 remapping engines and a CWDM cassette. For a mixed configuration, refer to the FTX description if the channel is an optical transmitter, or the FRX description if the channel is an optical receiver. The remapping engine routes and processes the copper and optical signals. It consists of a CWDM or 1310 SFP optical transceiver, a bidirectional BNC cable interface and a re-clocker with selectable inputs. The role of the channel, transmitter or receiver, is determined by how the SFP optical transceiver is connected to the CWDM cassette and to its channel s rear panel ST connector, and if the SFP optical input is illuminated or not. When wired as a transmitter (FTX), the SFP is always a CWDM and its optical input is always connected to one of the 6 rear ST channel connectors and its optical output to the CWDM cassette. Its receiver output is presented to the re-clocker. Electrical signals from the BNC interface are also presented to the re-clocker. If there is sufficient illumination of the SFP, the re-clocker chooses the SFP signal. If not, the BNC signal is chosen, with the cable interface set to be an input. The re-clocker then optionally re-clocks the chosen signal and sends it to the SFP transmitter input and from there to the CWDM cassette. When wired as a receiver (FRX), the SFP can be a standard 1310 or it can be a CWDM if the application requires it. In the receiver case, the optical input of the SFP always comes from the CWDM cassette. The SFP optical output always goes to one of the 6 rear ST channel connectors. When the SFP is illuminated by a signal from the transmitter, the re-clocker chooses the SFP signal, optionally re-clocks it, and sends it to the SFP s transmit section for optical output on a remapped CWDM wavelength if the application requires it, or on a standard 1310 wavelength. At the same time, it is also sent to the BNC cable driver which is now set to be an output. 4

TRANSMITTER FRONT AND REAR PANELS The front and rear panels of the FTX are shown below in Fig. 1. The rear panel has one ST/UPC optical input and one BNC input for each channel, labeled CH1 thru CH6, plus a COMMON ST/UPC output port for the resulting CWDM optical signal. Besides a POWER LED, which is green when power is applied to the unit, the front panel has 6 STATUS LEDS, one for each of the 6 channels. Assuming the channel is a transmit channel, the STATUS LEDs are: Green whenever the rear panel ST optical input for the channel is illuminated with at least -15 dbm of signal OR, if the optical input has less than -18 dbm of signal, there is a carrier detected at the channel s BNC input. Yellow if the optical input is receiving between -18 and -15 dbm of signal, regardless of BNC input. Red if there is less than -18 dbm of optical signal AND no carrier is detected at the BNC input. This will cause the channel to be muted. Blinking Red if the laser has failed for the channel, regardless of input status. This would affect the channel s CWDM signal exiting the COMMON ST/UPC connector. Off if the channel is not populated. Note that the status LEDS do NOT indicate quality or type of signal. RECEIVER FRONT AND REAR PANELS The front and rear panels of the FRX are shown below in Fig.1. Note that the rear panel is identical to that of the FTX except that the directionality of the ports is reversed. Besides a POWER LED, which is green when power is applied to the unit, the front panel has 6 STATUS LEDS, one for each of the 6 channels. Assuming the channel is a receive channel, the STATUS LEDs are: Green whenever the CWDM wavelength representing the channel is illuminating the channel s optic with at least -15 dbm of signal. This is part of the signal that enters the unit via the COMMON ST/UPC connector. Note that we are referring to an individual wavelength, not the intensity of all 6 wavelengths together. Yellow if this CWDM optical signal is between -18 and -15 dbm. Red if this CWDM optical signal is less than -18 dbm. This will cause the channel to mute. Blinking Red if the laser has failed for the channel, regardless of input status. Although the rear panel ST optical output for the channel would cease to function, the BNC output for the channel will still function if the failure has not spread to the SFP s receive section and it is sufficiently illuminated. Off if the channel is not populated. Note that the status LEDS do NOT indicate quality or type of signal. 5

Fig. 1: FS-6000 FTX and FRX front panel and rear panel Fig. 1: FS-12000 FTX and FRX front panel and rear panel Fig. 1: FS-18000 FTX and FRX front panel and rear panel 6

POWER REQUIREMENTS The FiberSaver Series operates from 110 or 220 VAC with the included desktop universal input 12V power supply or other source from 9 to 24 VDC and at least 12VA of power. It uses a coaxial type connector (sleeve ground) on the rear panel labeled POWER. If desired, the units can be powered from a battery pack or automotive battery instead of the wall unit. INSTALLATION AND SETUP Switch Function Setting (Default values in Bold) 1 Channel 1 re-clock up=re-clock down=bypass 2 Channel 2 re-clock up=re-clock down=bypass 3 Channel 3 re-clock up=re-clock down=bypass 4 Channel 4 re-clock up=re-clock down=bypass 5 Channel 5 re-clock up=re-clock down=bypass 6 Channel 6 re-clock up=re-clock down=bypass 7 Reserved Always leave in up position 8 Reserved Always leave in up position Table 1. Settings for Configuration Switch in the FiberSaver Series FTX or FRX Reclocker Signal Muted? bypassed Any no on SMPTE no on Non-SMPTE yes x No carrier or no illum yes Table 2. Automute Functionality. No special sequence must be followed to connect and start up the unit. RG59 or other 75 ohm coaxial cable must be used for the BNC SDI inputs and outputs, and single mode fiber with ST/UPC connectors must be used for the fiber links. Multimode fiber cannot be used with the FS-6000. At the FTX, or at a transmit channel if the configuration is mixed, you can use either the optical or the BNC input. The primary input to the channel will be the optical input at the ST/UPC connector for that channel. The FiberSaver Series FTX can accept wavelengths from 1100 to 1600 nm over SM fiber, with data rates between 19 and 2970 MBPS. The secondary input is the BNC connector for that channel. Note that the BNC input will only accept signals between 125 and 2970 MBPS, but the BNC output will function down to 19 MBPS. The channel will default to its optical input and ignore its BNC input as long as it is illuminated with at least -18 dbm. If the illumination is removed, the channel will look for a signal at its BNC input. The FTX and FRX should be connected by SM optical fiber at the COMMON ST/UPC connectors on their rear panels. This fiber will contain 6 CWDM signals representing the 6 channels. As such, it cannot go thru an O/E/O switch. At the FRX, or at a receiver channel if the configuration is mixed, there will be simultaneous optical output from the ST/UPC connector and electrical output from the BNC connector for that channel. The FRX optical output may be standard 1310nm or it can be ordered with a CWDM wavelength as required by the customer. The FiberSaver Series comes standard as stand-alone units. An optional rack-mounting kit is available to mount up to 3 units in a 1 Rack-unit or 1 ¾ by 19 rack space. The part number is RMT. The FS-6000 requires room for adequate ventilation around the units. Do not block the fan vent holes on the top of the case. 7

8

9

General Power:.................................................9-24V / 12VA Impedance:................................................. 75 ohms Return Loss, < 1.5 GHz:........................................... > 15 db Return Loss, < 3.0 GHz:........................................... > 10 db Max Cable Length, < 3.0 GHz:........................................ > 120 m Added Jitter:................................................. < 0.06UI Laser Safety.................................................. Class 1 Optical Power.......................................... 8 dbm to 0 dbm Optical Sensitivity.............................................. -18 dbm Operating Temperature........................................0 to 50 deg C Data Rates, Optical I/O or BNC Out............................... 19 to 2970 MBPS Data Rates, BNC Input:..................................... 125 to 2970 MBPS Transmitter (-FTX) Input Wavelength (each channel)................................. 1100 to 1600 nm Output Wavelengths (common)...................................... 6 CWDM Receiver (-FRX) Input Wavelengths (common)....................................... 6 CWDM Output Wavelength (each channel)................................. CWDM or 1310 *Specifications are subject to change without notice. 10

110 Newton Place Hauppauge, NY 11788 (800)-488-8378 / (516)-671-7278 sales@multidyne.com www.multidyne.com 11