Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Similar documents
SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

MICROMASTER Encoder Module

Trusted 40 Channel 120 Vac Digital Input FTA

KRF EMC Filters Installation, Operation and Maintenance Manual

Power Injector 1520 Series

Trusted 40 Channel 120 Vac Digital Input FTA

Trusted 40 Channel Analogue Input FTA

Installation Manual Original Instructions - IW4001

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

Function Manual SIMATIC HMI TP900. Operator Panel.

AF-300 E11 Adjustable Frequency Drive

4 Wiring Brochure Wiring and installation of specific control

llen-bradley 194R-HM4-NFPA3

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

USER S MANUAL. FX2N-8AD Analog input block

Operating Instructions Dimmer for V Incandescent Lamps

Frequency Converter Fv

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

LED Thunder S-150 Code 1097

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

Installation Operation Maintenance

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Spectra Batten (Order code: LEDJ95)

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

Generator protection relay

Installation Guide VL-MV10. Model No.

Fusion 120 Zoom. User Manual. Order code: EQLED068

Gamma instabus. Technical product information

LED Driver Linear / area fixed output

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

Model 1421 Distribution Amplifier

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Trusted TMR I/O SmartSlot Slot Cables

OPERATION MANUAL. USF-402AADC Audio Analog Digital Converter. 1 st Edition

Monochrome Video Monitors

Solis Export Power Manager

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

SQM40/41 Actuators for air and gas dampers

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Model Number Structure

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

.Power Distribution Center. PD-1. Instruction Manual

Cisco Aironet 1520 Series Outdoor Mesh Access Point Power Injector Installation Instructions

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

3 line filters for converters and power electronics

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

YLAA YLAA0175 AIR-COOLED SCROLL CHILLERS STYLE A, B or C (60 Hz) TON KW

DATAGAUSS XL HARD DRIVE DEGAUSSER

NEA WIRING CENTRE NEA HT 230V /24 V

HEX16 Strip User Manual

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Cylindrical Photoelectric Sensor CY-100 SERIES

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Safety Light Curtain C 4000

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

DISTRIBUTION AMPLIFIER

Cyclo Series. user manual. MartinArchitectural

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

DALI TOUCHPANEL BASIC TW. Operating and control unit

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

User Guide. HDMI Fiber Optic Extender. DVI-7350a


User s Manual. LG Industrial Systems G3F AT4A. LG Programmable Logic Controller

High performance circuit breakers

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Figure 1: Device components

/ PAT01 USER MANUAL

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

General Specifications

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Filters for Power Lines (Low Leakage Current)

Bench Test Instruments and Handheld Oscilloscopes Basic Service

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Digital Indicating ORP Meter AER-101-ORP. Instruction Manual

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

Transcription:

Operating Manual (Edition 04/2004) sinamics Line Reactors SINAMICS G130

Contents 1. Safety Information 2 2. General 5 3. Mechanical Installation 6 4. Electrical Installation 8 5. Technical Specifications 10 Operating Manual 1

Safety Information 04/04 1. Safety Information 1.1 Definitions and Warnings Qualified Personnel For the purpose of this documentation and the product warning labels, a qualified person is someone who is familiar with the installation, mounting, start-up, operation and maintenance of the product. He or she must have the following qualifications: Trained or authorized to energize, de-energize, ground, and tag circuits and equipment in accordance with established safety procedures. Trained in the proper care and use of protective equipment in accordance with established safety procedures. First aid training. DANGER Danger indicates that death, severe personal injury, or substantial property damage will result if proper precautions are not taken. WARNING Warning indicates that death, severe personal injury, or substantial property damage can result if proper precautions are not taken. CAUTION Caution with a warning triangle indicates that minor personal injury can result if proper precautions are not taken. CAUTION Caution without a warning triangle indicates that material damage can result if proper precautions are not taken. 2 Operating Manual

04/04 Safety Information IMPORTANT Important indicates that an unwanted result or situation can result if the appropriate advice is not taken into account. NOTE Note indicates important information about the product or respective part of the documentation that is essential to highlight. WARNING Hazardous voltages are present in this electrical equipment during operation. Non-observance of the warnings can result in severe personal injury or property damage. Only qualified personnel should work on or around the equipment. This personnel must be thoroughly familiar with all warning and maintenance procedures described in this documentation. The successful and safe operation of this device is dependent on correct transport, proper storage and installation, as well as careful operation and maintenance. National safety guidelines must be observed. Operating Manual 3

Safety Information 04/04 1.2 Safety and Operating Instructions DANGER This equipment is used in industrial high-voltage installations. During operation, this equipment contains rotating and live, bare parts. For this reason, they could cause severe injury or significant material damage if the required covers are removed, if they are used or operated incorrectly, or have not been properly maintained. When the machines are used in non-industrial areas, the installation location must be protected against unauthorized access (protective fencing, appropriate signs). Prerequisites Those responsible for protecting the plant must ensure the following: The basic planning work for the plant and the transport, assembly, installation, commissioning, maintenance, and repair work is carried out by qualified personnel and/or checked by experts responsible. The operating manual and machine documentation are always available. The technical data and specifications regarding the applicable installation, connection, environmental, and operating conditions are always observed. The plant-specific assembly and safety guidelines are observed and personal protection equipment is used. Unqualified personnel are forbidden from using these machines and working near them. This operating manual is intended for qualified personnel and only contain information and notes relating to the intended purpose of the machines. The operating manual and machine documentation are written in different languages as specified in the delivery contracts. NOTE The services and support provided by the SIEMENS service centers are recommended for planning, installation, commissioning, and servicing work. 4 Operating Manual

04/04 General 2. General Description Line reactors limit low-frequency line reactions to permissible values. Note The connection lines to the power module must be kept as short as possible. Caution The surface temperature of the line reactors may exceed 80 C. Assigning the Line Reactor and Power Module Table 2-1 Assigning the line reactor and power module Power module Rated power of power Suitable line reactor module Supply voltage: 380 480 V 1GE36-1AA0 315 kw 6SL3000-0CE36-3AA0 1GE37-5AA0 400 kw 6SL3000-0CE37-7AA0 1GE38-4AA0 450 kw 6SL3000-0CE38-7AA0 1GE41-0AA0 560 kw 6SL3000-0CE41-0AA0 Supply voltage: 660 690 V 1GH33-3AA0 315 kw 6SL3000-0CH33-4AA0 1GH34-1AA0 400 kw 1GH34-7AA0 450 kw 6SL3000-0CH34-8AA0 1GH35-8AA0 560 kw 6SL3000-0CH36-0AA0 1GH37-4AA0 710 kw 1GH38-1AA0 800 kw 6SL3000-0CH38-4AA0 Operating Manual 5

Mechanical Installation 04/04 3. Mechanical Installation Dimension Drawing l5 l4 l5 Installation holes d3 n1 a5 a2 a4 n2 h3 h2 a4 n2 n5 a4 a3 h3 h ma x h ma x h1 h2 a3 n1 n3 n4 Fig. 3-1 Dimension drawing of line reactor 6 Operating Manual

04/04 Mechanical Installation Table 3-1 Dimensions of line reactor 380 V 480 V (all specifications in mm) 6SL3000-0CE36-3AA0 0CE37-7AA0 0CE38-7AA0 0CE41-0AA0 a2 30 30 40 50 a3 6 6 8 8 a4 15 15 20 25 a5 14 14 14 14 I4 300 300 350 350 I5 100 100 120 120 hmax 269 269 321 321 h2 180 180 252 252 h3 60 60 120 120 n1 1) 118 118 138 138 n2 1) 224 224 264 264 n3 212.5 212.5 211.5 211.5 d3 M8 M8 M8 M8 1) Lengths n1 and n2 correspond to the drill hole spacing Table 3-2 Dimensions of line reactor 660 V 690 V (all specifications in mm) 6SL3000-0CH33-4AA0 0CH34-8AA0 0CH36-0AA0 0CH38-4AA0 a2 25 30 30 40 a3 5 6 6 8 a4 12,5 15 15 20 a5 11 14 14 14 I4 270 350 350 410 I5 88 120 120 135 hmax 248 321 321 385 h2 150 198 198 252 h3 60 75 75 120 n1 1) 101 138 138 141 n2 1) 200 264 264 316 n3 200 232.5 232.5 224 d3 M8 M8 M8 M10 1) Lengths n1 and n2 correspond to the drill hole spacing Operating Manual 7

Electrical Installation 04/04 4. Electrical Installation Important Safety Precautions WARNING The devices are operated with high voltages. All connection procedures must be carried out with the cabinet de-energized. All work on the units must be carried out by trained personnel only. Death, serious injury, or substantial material damage can result if these warnings are not taken into account. Work on an open device must be carried out with extreme caution because external supply voltages may be present. The power and control terminals may be live even when the motor is not running. Dangerously high voltage levels are still present in the device up to five minutes after it has been disconnected due to the DC link capacitors on the power module. For this reason, the cabinet should not be opened until after a reasonable period of time has elapsed. The operator is responsible for ensuring that the line reactors and other components are installed and connected in accordance with the recognized technical rules in the country of installation and applicable regional guidelines. Special attention should be paid to cable dimensioning, fuses, grounding, shutdown, disconnection, and overcurrent protection. If an item of protective gear trips in a branch circuit, a leakage current may have been disconnected. To reduce the risk of fire or an electric shock, the currentcarrying parts and other components in the cabinet unit should be inspected and damaged parts replaced. When an item of protective gear trips, the cause of the trip must be identified and rectified. 8 Operating Manual

04/04 Electrical Installation When connecting the line filter and line reactor, you must take into account the following conditions to ensure that they function correctly: Use shielded control cables. The shield must be connected at both ends. With analog control cables, connecting the shield at both ends can result in coupled-in noise. To prevent this, the shield must only be connected at one end on the power module. Control cables must be routed separately from power cables. Power cables are motor cables or connection cables from the DC link of the power module (terminals C/ L+ and D/ L ) to other components (e.g. braking module). In particular, you must ensure that control cables and power cables are not routed in parallel in a joint cable raceway, even if all the cables are shielded. You must use a shielded motor cable. The shield for the motor cable must be attached to the shield plate and motor housing. The ground wire for the motor must be fed directly back to the power module. Overview Line filter Line reactor Power module Line L1 L2 L1' L2' 1U1 1V1 1U2 1V2 U1 V1 U2 V2 Load L3 Netz Last L3' 1W1 1W2 W1 W2 PE PE' PE1 PE2 Mounting plate Fig. 4-1 Connecting the line filter, line reactor, and power module Operating Manual 9

Technical Specifications 04/04 5. Technical Specifications General Technical Specifications Table 5-1 General technical specifications Line frequency Degree of protection IP 00 Ambient conditions 47 Hz to 63 Hz Operation Storage Transport Ambient temperature 0 C to +50 C -25 C to +70 C -25 C to +70 C Humidity range (non-condensing) Corresponds to class 5 % to 95 % 3K3 to IEC 60 721-3-3 5 % to 95 % 1K4 to IEC 60 721-3-1 5 % to 95 % at 40 C 2K3 to IEC 60 721-3-2 Mechanical stability Vibratory load: Deflection Acceleration Corresponds to class 0.075 mm at 10 Hz to 58 Hz 10 m/s² at >58 Hz to 200 Hz - 1.5 mm at 5 Hz to 9 Hz 5 m/s² at > 9 Hz to 200 Hz 1M2 to IEC 60 721-3-1 3.5 mm at 5 Hz to 9 Hz 10 m/s² at > 9 Hz to 200 Hz 2M2 to IEC 60 721-3-2 Shock load: Acceleration Corresponds to class 100 m/s² at 11 ms 3M4 to IEC 60 721-3-3 40 m/s² at 22 ms 1M2 to IEC 60 721-3-1 100 m/s² at 11 ms 2M2 to IEC 60 721-3-2 10 Operating Manual

04/04 Technical Specifications Specific Technical Specifications Table 5-2 Technical specifications for line reactors (380 V 480 V) Order number Unit 6SL3000-0CE36-3AA0 Suitable for power module 1GE36-1AA0 6SL3000-0CE37-7AA0 1GE37-5AA0 6SL3000-0CE38-7AA0 1GE38-4AA0 Rated voltage V 3 AC 380 V to 480 V ±10 % (-15 % < 1 min) 6SL3000-0CE41-0AA0 1GE41-0AA0 I thmax A 628 773 871 1022 Rated inductance µh 27 22 19 16 Power loss at 50/60 Hz kw 0.287/0.324 0.273/0.311 0.356/0.400 0.386/0.434 Line/load connection Weight kg 41.4 51.3 63.2 69.6 Dimensions Length (total) Width (total) Height mm 300 212.5 269 300 212.5 269 350 211.5 321 350 211.5 321 Table 5-3 Technical specifications for line reactors (660 V 690 V, part 1) Order number Unit 6SL3000-0CH33-4AA0 Suitable for power module 1GH33-3AA0 6SL3000-0CH34-8AA0 1GH34-1AA0 1GH34-7AA0 Rated voltage V 3 AC 660 V to 690 V ±10 % (-15 % < 1 min) 6SL3000-0CH36-0AA0 1GH35-8AA0 I thmax A 342 482 482 597 Rated inductance µh 81 65 65 46 Power loss at 50/60 Hz kw 0.210/0.238 0.279/0.313 0.371/0.418 0.376/0.423 Line/load connection lugs M10 Weight kg 38.9 55.6 55.6 63.8 Dimensions Length (total) Width (total) Height mm 270 200 248 350 232.5 321 350 232.5 321 410 224 385 Operating Manual 11

Technical Specifications 04/04 Table 5-4 Technical specifications for line reactors (660 V 690 V, part 2) Order number Unit 6SL3000-0CH38-4AA0 Suitable for power module 1GH37-4AA0 1GH38-1AA0 Rated voltage V 3 AC 660 V to 690 V ±10 % (-15 % < 1 min) I thmax A 840 840 Rated inductance µh 40 40 Power loss at 50/60 Hz kw 0.390/0.416 0.480/0.541 Line/load connection Weight kg 98 98 Dimensions Length (total) Width (total) Height mm 410 224 385 410 224 385 12 Operating Manual

Siemens AG Automation and Drives Large Drives P.O. Box 4743, D 90025 Nuremberg Germany www.ad.siemens.de Siemens AG 2004 Subject to change without prior notice Doc. no.: A5E00331462A Printed in Germany