INSTRUCTION MANUAL DAFM2

Similar documents
User's Manual. CFM/CMM Thermo Anemometer 94204

User s Manual. Model Digital Sound Level Meter

CFM/CMM Thermo Anemometer

True RMS AC/DC Mini Clamp Meter

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Operating Instructions

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

900-Lumen Portable LED Projector Part #: User manual

Metal Electrode Meter

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

minihomer TM User s Guide

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

Owner s Manual. Backup Monitor System. LCD Monitor & CCD Color Camera

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

Satellite Receiver. Chapter REMOTE CONTROL USING THE MENUS USING TEXT FIELDS. About Your Satellite Receiver. What you ll find in this chapter:

Quick Installation Guide. Indoor / Outdoor Antenna, Antenna Cable & Surge Arrestor

Operating Instructions

KHT 1000C HV-Probe Calibrator. Instruction Manual

U SER S G UIDE. TS2002A Fiber Optic Test Kit

Single Station Waterproof Timer

SC-606 Instructions. Pushbutton F MEMORY RECALL/SET Pushbutton E MODE/NEXT

ezcinema Plus Series

Grandbeing. HDMI Matrix (Router Type) Features

CABLE TESTER User Manual

what s in the Box? Camera transmitter with power cable 3M sticker 2 RVS SYSTEMS

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

User s ManUal NON-CONTACT TACHOMETER. Please read this manual carefully and thoroughly before using this product.

BASIC PH METER BASIC PH METER KIT

Installation & Programming Manual. Please read before using this timer.

OWNER'S MANUAL SIGNAL COMMANDER

Table of Contents. Introduction...1

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

MP-7424 Football Scoreboard with MP5000 Console

Digi-Wave DLR-50. Digital Receiver. user guide MAN156D

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact us. This manual may contain technical or

Kramer Electronics, Ltd. USER MANUAL. Model: VA-100P-5. Power Supply

AUDIO WIRELESS. with IR Extender Feature OWNER S MANUAL SENDER T CAT. NO

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

HIIT Console OWNER S MANUAL

Loctite. EQUIPMENT Operation Manual. Zeta 7011-A Dosimeter-Radiometer for UVA Part Number 98086

Grandbeing. HDMI Converter. Operating Instructions(P/N of this Instructions is INSSH S) FEATURES

GME. User s Manual. Rev 1.3

Electric Motorized Projection Screen Spectrum Series

Indoor/Outdoor Security System with Quad Monitor User s Manual

3.5 TFT LCD CCTV Service Viewer with Wristband

Instruction Manual. Wireless Transmitters (Digital) RVS-550W. Reverse With Confidence 1

LED Programmable Interval Timer Owner's Handbook

Kramer Electronics, Ltd. USER MANUAL. Model: VA-14. 4x1 Balanced Audio Mixer

BRIGHTLINK HD Video Wall Controller BRIGHTLINKAV.COM

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

Owner's Manual DIGITAL TO ANALOG BROADCAST CONVERTER WITH REMOTE CONTROL. Model: CVD508 PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

OA White OA Black. Owner s Manual. Low Profile Digital HDTV Over-the-Air Antenna. w/built-in KING SureLock Digital TV Signal Meter

FD70CV-M-C-9. Installation and Operation Manual. 7 NVG Compatible LCD. Revision Date: 06/16/2017 Page 1 of 12. Rev: A

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

Operating Instructions

Kramer Electronics, Ltd. USER MANUAL. Model: 6809HD. HD/SD-SDI AES Embedder

GPS. Quick Start Guide. Model #: Lit# /04-10

User s Manual. 4X1 HDMI Switcher Part #: DL-HDS41

INSTRUCTION BOOK FOR. Deluxe Insta-Theater

Kramer Electronics, Ltd.

LDG TW-2 Talking Wattmeter For VHF and UHF

HDMI Extender EX12 MODEL:SX-EX12. Dear Customer FEATURES NOTICE. Operating Instructions

WS-6002U Atomic Clock. Instruction Manual

Kramer Electronics, Ltd.

Grandbeing. HDMI Splitter(Asynchronous Switching Method) Operating Instructions(P/N of this Instructions is INSGB07SW0102)

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200N5. 1:2 High Resolution UXGA DA

Low Profile Digital HDTV Over-the-Air Antenna CONTENTS

The specially designed stand (Included) made possible to use it indoor as well.

1. INTRODUCTION 1.1 Remote Control key guide

User s Manual. Component video to 1-fiber DVI converter, CNDF-200. Manual Contents.

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

MODEL HA07 - MASTER CONTROLLER INSTRUCTIONS

Large Display ORP Pen

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

Phone (440) Fax Wireless Rear Observation System With Night Vision Camera

Grandbeing. HDMI Splitter. Operating Instructions(P/N of this Instructions is INSSP )

Garmin GC 10 Marine Camera Instructions

3x1 HDMI Switch with Audio extraction Support Ultra HD 4K, ARC, CEC

RemotePoint. Navigator. User s Manual VP4150

Owner s Manual. VL9000 Series HEADREST MONITOR SYSTEM

Instruction Manual. 7" Wireless Camera System with Wired Side Camera Inputs RVS-355W. Reverse With Confidence 1

Operating Instructions DCI-50-CT Cable Identifier

Kramer Electronics, Ltd.

Grandbeing. HDMI Matrix. Operating Instructions(P/N of this Instructions is INSMX0404-HH1) FEATURES

Professional 4-channel Thermocouple Thermometer plus Infrared Thermometer

Warner Photoscanner MCS-500 Series LED Photoelectric Control

JACK Digital HDTV Over-the-Air Antenna w/built-in SureLock Digital TV Signal Meter

J C F A U D I O DA8-V DA8-V USER MANUAL JCF AUDIO, LLC CAMARILLO ST. NORTH HOLLYWOOD, CA

TR-2 OPERATION MANUAL

ES-450J2 Universal 2 Channel Jog/Shuttle Remote

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

Grandbeing. HDMI Convertor. Operating Instructions(P/N of this Instructions is INSMS A) FEATURES

HDTV Supply. Mega Scaler. Operating Instructions FEATURES

Kramer Electronics, Ltd. USER MANUAL. Model: PT-101HDCP. DVI Repeater

Kramer Electronics, Ltd. USER MANUAL. Model: PT-101Hxl. HDMI Repeater

Transcription:

INSTRUCTION MANUAL DAFM2 1-800-547-5740 Fax: (503) 643-6322 www.ueiautomotive.com email: info@ueiautomotive.com

Introduction The DAFM2 is used to check air velocity FPM (feet per minute) and CFM (cubic feet per minute) in residential, light commercial and standard commercial systems. This meter eliminates the need for analog charts. It is a hand-held, battery-powered meter, that makes air flow and velocity measurements with an accuracy of ±2%. Temperature measurements are made with an accuracy of ±1%. Features include Convenient direct digital readout of actual air flow or velocity with out using conversion charts Large dual digital display for simultaneous air flow or velocity and temperature measurements Air flow and velocity measurements accurate to ±2% Temperature measurements accurate to ±1 F (±0.6 C) Battery saving automatic power off Low battery icon Data hold function MAX/MIN/AVG recording function Safety Notes Before using this meter, read all safety information carefully. In this manual the word "WARNING" is used to indicate conditions or actions that may pose physical hazards to the user. The word "CAUTION" is used to indicate conditions or actions that may damage this instrument. WARNING! Objects striking the fan may damage meter. 1. ON/OFF RESET 2. MODE (Select) VEL (FPM) FREE AREA FLOW (CFM) 3. HOLD ADVANCE 4. MIN/MAX RECORD Single Print 5. NEXT DIGIT Multi-point Average Operating Instructions Measuring Air Velocity (Single Point) feet per minute (FPM) 1. Press the ON/OFF button to turn the meter on. Every display feature will appear for a few seconds when the meter is turned ON. 2. The DAFM2 is ready for use when the LCD displays "vel" (the default mode) in the upper left corner, and the temperature appears in the lower right corner (Fig 1). (Fig 1) 3. Hold the sensor in front of an air source. The meter will display Feet Per Minute (FPM) readings. 1 4 C o n t rols and Indicators 2 5 Displaying a continuous moving average The DAFM2 has the ability to display a continuous moving average for up to two hours. 1. Turn the power ON. 2. Place the sensor in front of an air flow source. 3. Press MIN/MAX record key once. An AVG in the lower left corner of the display confirms the meter is in the continuous moving average measurement mode. The display will update once per second (Fig 2). (Fig 2) MIN/MAX/AVG (Single Point) To obtain MIN/MAX/AVG readings on a single point. 1. Turn the meter ON. 2. Place the sensor in front of an air flow source. DAFM2-MAN P. 1

3. Press MIN/MAX record button. The unit will begin to record the readings. The instrument displays the average velocity by default. Each of the MIN/MAX button cycles the display through: Real-time readings MIN velocity M AX velocity Back to AVG velocity Air velocity average for multi points 1. Turn the meter ON, and position the fan at the first point to be measured. As soon as the first measurement is completed, press the HOLD key (you will hear a single beep) and release it. The display will show a HOLD indicator above the reading (Fig 4). The reading is locked at the value display when hold was pressed. Note: Feet Per Minute (FPM) readings can be converted to CFM readings. 4. Press the HOLD button to store the readings before moving the meter away from an air flow source. 5. Press ON/OFF RESET twice to clear the current MIN/MAX average readings and once to turn the meter OFF. Direct measuring of air flow (Single Point) CFM Air velocity measurement is calculated by multiplying the air velocity readings times the free area dimension. Free area is publishing by the grill and register manufacturer you are servicing. (Fig 4) 2. Press the MIN/MAX record key (you will hear a single beep) and release it. The display will show a digit numbered from 1 to 8. This number represents the point that is being recorded (Fig 5). Determine the free area of the air source you are measuring and enter it into the meter. 1. Turn the power ON. 2. Press the mode select once (you will hear one beep). The meter will display AREA in upper case letters at the top of the display, and 1.111, with a flashing initial digit (Fig 3). This is the free area default setting. (Fig 3) (Fig 5) Repeat this process until all desired points have been measured and recorded. 3. Once all measurements have been recorded, press the NEXT DIGIT/MULTIPOINT AVERAGE key. The meter will display the average air velocity reading and number of points measured (Fig 6). The meter can record a total of eight (8) points at one time. 3. To increase numbers, the flashing digit can be changed by pressing the HOLD/ADVANCE key. 4. To change the value of other digits, press the NEXT DIGIT key. 5. Press the RECORD key. The flashing will stop. Then press the HOLD key to save the changed value. The meter returns to FLOW mode automatically. 6. Press the MODE select button once to return to the "vel" mode. The meter is now ready to measure air flow (CFM). MIN/MAX/AVG CFM READING Repeat steps 1-6 from earlier instructions to obtain MIN/MAX/AVG CFM readings from a single point. (Fig 6) 4. To CLEAR THE MEMORY of current Multi Point Average readings, press and hold the NEXT DIGIT/MULTIPOINT AVERAGE key until the unit beeps twice, then release. The unit must be in velocity/fpm mode to clear current average readings. Air Flow (CFM) Average for Multipoints Once the multi-point average is determined: 1. Press the MODE button once, and confirm the correct free area setting is locked into the meter. (If the free area setting must be adjusted, make necessary changes now). 2. If the free area setting is correct, press the MODE button again to enter the meter's air flow mode. DAFM2-MAN P. 2

3. The meter will now display an average air flow reading and the number of points measured (Fig 7). Troubleshooting Low battery icon visible on display or no display Change the 9 volt battery in the meter. E6 or continuous beeping This signal indicates the probe is disconnected from the meter body or is not properly connected. (Fig 7) The meter's free area dimension has been set to 1.111 square feet, a commonly-used free area dimension in the U.S. If you want to measure the air flow for a single point without changing the area dimension, power the meter ON, position the fan, and then press the MODE key twice. This will put you into air flow (CFM mode. The air flow (CFM) display is equal to the current air velocity reading (FPM x FREE AREA = CFM) times 1.111 square feet. SUGGESTION: Set the free area dimension before starting to measure the air velocity, so after you measure the air velocity, you can jump to the air flow mode to view the cubic feet per minute reading without further changing the free area dimension. Sensors fan will not turn Purchase new sensor probe. Battery Replacement This meter requires a standard 9 volt batter for operating power. Remove the screw from the lower back of the meter. Lift the panel out and remove the battery. Reverse the process to install a new battery and replace the cover. Specifications Non Sleep Mode To bypass the auto power off: For continuous operation, press the ON and HOLD buttons at the same time, then release ON only. An "n" will appear on the LCD. You can then release the HOLD key. The meter will remain ON until the meter is turned off. Changing default settings 1. The default setting for the air velocity measuring unit is "feet/minute". The default setting for the unit of temperature is "F". To change the measuring units to "meters/sec" and "C". a. Turn the meter ON by pressing the ON and AVERAGE keys at the same time. Release ON button first. The LCD will display a small signal, "ft/m", in the upper right corner and an F in the lower right corner. Then release the AVERAGE key. b. Press the HOLD key to change the measuring units to the metric system. Press the AVERAGE hey to return to the SAE/imperial measuring units. c. Press the RECORD key. An "S" will show on the LCD. Press the HOLD key to confirm and save the changed value. At this time, "2400" appears on the LCD. Press RECORD. An "S" appears on the LCD. Press the HOLD key to confirm, and save the value. Auto power off The meter will turn off automatically after 20 minutes, to save the battery. This will be preceded by three (3) beeps. Airflow: Digital display (LCD): Temperature: Battery type: Battery life: Display type: Display size: Max reading: Size (H x W x D) Diameter of fan: Auto power off: ACCURACY Airflow 125-4900 ft./min. 0.7-25 m/sec Temperature -10 to 50 C +14 to 122 F Resolution 1 0.01 0.1 0.1 125-4900 ft/min 0.7-25 m/sec Counts - 4000 Updates 3 times/sec -10 to +50 C 14 to +122 F 9 volt 100 hrs. typical (alkaline) LCD 1 1/4" x 1 5/8" (37 mm x 42 mm) 9999 7 1/8" x 2 3/4" x 1 3/8" (181 mm x 71 mm x 38 mm) 2 7/8" (70 mm) 20 minutes bypass Accuracy ±2% ±2% ±0.6 C ±1.0 F DAFM2-MAN P. 3

DAFM2 Thermo Anemometer Limited Warranty The DA FM2 is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase. If within the warra n ty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi s option. This warra n ty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and consequential damage resulting from failed batteries are not covered by warra n ty. Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase date will be required before warra n ty repairs will be rendered. Instruments out of warra n ty will be repaired (when repairable) for a service charge. Return the unit postage paid and insured to: 1-800-547-5740 FAX: (503) 643-6322 www.ueiautomotive.com Email: info@ueiautomotive.com This warranty gives you specific legal rights. You may also have other rights which vary from state to state. PLEASE RECYCLE Copyright 2007 UEi Automotive DAFM2-MAN 1/07