Data. X-ray Image Intensifier HIDEQ 23-3 ISP

Similar documents
X-ray Tube Housing Assembly H1076X H1076Y Print No.HA Release Date:

Ergonomic design packed with powerful performance MULTIMOBIL 5C. Answers for life.

Financial disclosure statement. Fluoroscopic Equipment Design: What s s Different with Flat Panel? Concept of flat panel imager

ziehm imaging ... dedicated to clinical innovation Ziehm Vista. TECHNICAL SPECIFICATIONS Most Versatile C-arm.

SPECIFICATION. Spec No : VSS-1402-CS603B

VTA0832H Series Linear Photodiode Array (PDA) for X-ray Scanning

ETSI ES V1.1.1 ( )

VTA1216H Series Linear Photodiode Array (PDA) for X-ray Scanning

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses. Unprecedented design freedom for solid state

ITS-I. Test station for evaluation of image quality of image intensifier tubes. Fig. 1. Photo of the ITS-I test station: a)photo, b)block diagram

THE DIGITAL FLAT-PANEL X-RAY DETECTORS

:: Reduce needs for heat dissipation components. :: Extend battery life in mobile products. :: Save power and reduce heat generation in TVs

Documentation. Magnetic Encoder System (MES) Version: Date:

Thank you for your interest in BARCO s dedicated Home Theater products and more particular in our top-model, the CINE9.

Development of OLED Lighting Applications Using Phosphorescent Emission System

Optical Perfection. HIGHYAG Beam Delivery Products

DATASHEET. Intematix ChromaLit Contour. Remote Phosphor Light Source. Features & Benefits. ChromaLit Contour. Application & Uses. A19 Reference Design

Intra-oral X-ray unit with high frequency DC generator. Product Data

Detailed Specifications & Technical Data

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

Global Trade Medical Supplies

INTERNATIONAL STANDARD

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

SOLO ADSS Short-Span Cables, Fibers

CARESTREAM VITA/VITA LE/VITA SE CR System Long Length Imaging User Guide

Advanced Sensor Technologies

Illuminating the home theater experience.

BARCOVISION 708 SERIES

Phosphorescent OLED Technologies: The Next Wave. Plastic Electronics Conference Oct 9, 2012

LED Display Backlighting Monitor Applications using 6-lead MULTILED Application Note

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

RADIOGRAPHIC PERFORMANCE OF CYGNUS 1 AND THE FEBETRON 705

Communication Theory and Engineering

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses

ADVANCED OPTICAL FIBER SOLUTIONS

EXT-3GSDI-FOSM User Manual

Development of OLED Lighting Panel with World-class Practical Performance

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

VISERA 4K UHD GET CLOSER. GET CLOSER Four Times the Resolution of Full HD.

ORION NEWSLETTER

ELECTRON OPTICS OF ST-X, ST-Y SERIES OF STREAK & FRAMING CAMERA TUBES

Mining and Petrochemical Fiber Optic Cables

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

This document is a preview generated by EVS

INSTRUMENT CATHODE-RAY TUBE

Optical Engine Reference Design for DLP3010 Digital Micromirror Device

Sodern recent development in the design and verification of the passive polarization scramblers for space applications

Colour Explosion Proof Video Camera USER MANUAL VID-C

Image Intensifier User Guide

DML 5000 Inline Laser Thickness Measurement for Quality and Production Assurance

David Mrnak, International Sales Department, eyevis GmbH

R&S ZN-Z154 Calibration Unit Specifications

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Design Criteria for Window Tinting Approved March 26, 2009

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

AMERICAN NATIONAL STANDARD

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

MKH 8060 Directional studio microphone

Long Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, CWDM, 3R Transponder WaveReady Transponder 740 LR CWDM

Drop Passives: Splitters, Couplers and Power Inserters

R&S ZN-Z85 Switch Matrix Specifications

CNT FIELD EMISSION CATHODE CATALOG. XinRay Systems Inc. April 2014

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

METROTOM. Visible Metrology.

Multi-Touch Resistive Touch Screens

I n d u s t r i a l M e t r o l o g y f r o m C a r l Z e i s s. METROTOM. Visible Metrology.

Application note. Materials. Introduction. Authors. Travis Burt, Huang ChuanXu*, Andy Jiang* Agilent Technologies Mulgrave, Victoria, Australia

MAP Optical Power Meter Module (mopm-b1)

LASER DIODE NX8346TS nm AlGaInAs MQW-DFB LASER DIODE FOR 10 Gb/s APPLICATION DESCRIPTION APPLICATIONS FEATURES

ASP-FIBRS1 User Manual

Calaf integrated stereo amplifier

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

INTERNATIONAL STANDARD

Operating instructions

Reference 150 LINEAR

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Introducing Ultra Short LC : Fiber Optic Cable Assemblies

CPON-HFC. Customer Premises Optical Node for FTTH networks. About the Product

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

TECHNICAL SPECIFICATION

t LED Signage Solutions

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

16-element Si photodiode arrays

NSRP Electrical Panel July 2018

GUARD BAGAŽO TIKRINIMO VARTAI

R&S FSW-B512R Real-Time Spectrum Analyzer 512 MHz Specifications

4 Channel Video over Fiber With Ethernet

3M 8900 Single-mode SC Crimplok Connector

Easy programming Robust. Flexible. FPS Flexible Position Sensor FPS. Field of Application. Advantages Your benefit. Options and special Information

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

R&S FSW-K144 5G NR Measurement Application Specifications

easyspiral Dilute The world's fi rst automatic diluter & plater A revolution in serial dilutions!

DLA-HD750/ DLA-HD350 Full HD D-ILA Home Theatre Front Projector

Micro duct Cable with HDPE Sheath for Installation by Blowing

COMPOUNDING SYSTEMS FOR PROFESSIONALS

Optical Communications Mainframe - Laser Transmitter Module

Instruction manual MK 8

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

Transcription:

Data X-ray Image Intensifier HIDEQ 23-3 ISP

State-of-the-art Image Intensifier Technology HIDEQ 23-Mu Features and benefits HDQE cesium iodide input phosphor screen of very fine structure deposited on a highly transparent aluminium input window provides low quantum noise and excellent resolution and makes a significant reduction in X-ray dose possible Metal enamel technology providing high precision components with excellent X-ray transparency and negligible X-ray scatter Electron optical zooming for improved detail visibility and increased resolution properties HR output phosphor combined with a high contrast output window featuring an anti-glare screen and scattered light trap ensures high luminous efficiency and unsurpassed overall image definition with high contrast and high resolution HIDEQ 23-Min Automatic dynamic ion-getter pump to ensure the highest vacuum throughout tube life Mu-metal encapsulated tube for very low geometric distortion 9 /23 cm, three fields High DQE, resolution, contrast and conversion factor Low distortion Good luminance distribution HIDEQ 23-Lateral The products HIDEQ 23-Min and HIDEQ 23-Lateral bear a CE marking in accordance with the provisions of the 93/42/EEC directive dated June 14, 1993 concerning medical products, limited to the system component. The product HIDEQ 23-Mu does not bear a CE marking. Technology Image intensifiers from Siemens are renowned for their brilliant contrast and low geometric distortion. These are the results of continuous development in our product line. Blemish- and artifact-free Narrow process tolerances ensure constant electron-optical data, minimal disturbing blemishes and artifacts, resulting in excellent image quality. 2

Typical Specification Type HIDEQ 23-3 ISP Weight of unit (depending on housing type) [kg] 7 16 Overall length [mm] 336 Largest diameter [mm] 285 Diameter of output window [mm] 20 Thickness of output window [mm] 3.6 Output phosphor P43 wavelength [nm] 548 Input phosphor HDQE CsI layer IEC 61262-1 through 6: 1994-07 apply Full field Zoom 1 Zoom 2 Nominal entrance field size [mm] / [in] 230 / 9 Useful entrance field size [mm] 215 160 120 Spatial resolution at the image center [Lp/mm] 4.6 5.4 6.0 at the image edge (90%) [Lp/mm] 4.2 5.0 6.0 Conversion factor G x cd s cd s / m 2 µgy m 2 mr 26 / 226 13 / 113 6 / 52 Luminance non-uniformity [%] 20 4 4 Image distortion: differential at 90% radius [%] 17 5 5 integral at 90% radius [%] 4 1 1 Detective quantum efficiency DQE [%] 65 65 65 Contrast ratio: 10% area 22:1 23:1 26:1 10 mm diameter 15:1 16:1 19:1 3

Engineering Drawing 4

Engineering Drawing 5

The Siemens Vacuum Technology Division is ISO 9001 certified, manufactures in accordance with the Quality System Regulations (QSR) as defined by the Food and Drug Administration (FDA) and endeavors to comply with legal requirements concerning the environmental compatibility of its products. In addition, the performance within the scope set by the guidelines of European Foundation of Quality Management (EFQM) for the European Quality Award (EQA) is continuously monitored. The reproduction, transmission or use of this document or its content is not permitted without expressly written consent. Offenders will be liable for damages. This document is not considered to be a contractual specification. Kindly contact Siemens AG prior to using this information for equipment design. Siemens reserves the right to modify the design and specifications contained herein without prior notice. All rights reserved, particularly in connection with patent applications or registrations of utility model or design. Siemens AG Wittelsbacherplatz 2 D-80333 Muenchen Germany Headquarters Siemens AG, Medical Solutions Henkestr. 127, D-91052 Erlangen Germany Telephone: +49 9131 84-0 www.siemens.com/medical Contact Address Siemens AG, Medical Solutions Vacuum Technology Division, RVM P.O. Box 3260, D-91050 Erlangen Germany Telephone: +49 9131 84-69 37 Fax: +49 9131 84-60 22 www.siemens.com/vacuumtechnology E-mail: vacuumtechnology@siemens.com 08.2005, Siemens AG Printed in China RV 23 ISP DB 08050.5