User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

Similar documents
User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

XCOM1002JE (8602JE) Optical Receiver Manual

OPTICAL DISTRIBUTION STATION -

Optical Receiver Manual. Transmitter OP-OR212JSE. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

3M Fiber Optic Wall Mount Enclosure 8430 Series

User Manual E Rev (20) E Series. User Manual. Teleste Corporation. E3 Compact amplifier

OTX Optical Transmitter. Operation Instructions

Fiber Optic. Foreword. Special Tips:

QFMN. QFMN Fiber Mini Node Distribution Amplifier INSTALLATION & OPERATION MANUAL.

Compact EGC Fiber Deep Nodes A90100 and A90300

1.2 GHz GS7000 Node RF Split Upgrade Application Note

Prisma Optical Networks Ancillary Modules

User Manual ACE Rev (54) ACE Series. User Manual. Teleste Corporation. ACE3 Intelligent broadband amplifier

Multicom Optical Return Path Receiver MUL HRPR 4B

User Manual HDO Rev (24) HDO Series. User Manual. Teleste Corporation. HDO773 C-band DWDM fibre transmitter

DVO700 P FIBRE OPTIC TRANSMITTER

Model GS Port Node 1 GHz with 65/86 MHz split

OTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL

Compact Mini Amplifiers Series and Series

Description. Features MODEL ODN2P OPTICAL DISTRIBUTION NODE WITH TWO AMPLIFIED RF PORTS LIGHT LINK SERIES 2.

L-BAND over Fiber Link TX/RX. User Manual. L-1Ch-L-Band-TX/RX

Optical Communications Mainframe - Laser Transmitter Module

CPON-HFC. Customer Premises Optical Node for FTTH networks. About the Product

QFN. QFN Fiber Node INSTALLATION & OPERATION MANUAL.

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

clipping; yellow LED lights when limiting action occurs. Input Section Features

3M Distribution Box (DDB)

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Model GS7000 GainMaker Node Forward Local Injection Module Installation Instructions

QCA9-33 Active Combiner

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

L-Band Fiber Optic Link

Operating instructions

SatellitePlus Model OLAT/OLAR. Advanced L-Band Series. 10-4,000 MHz OPERATING MANUAL

Litile34 OPERATION MANUAL

Product Operation Manual

ENGINEERING COMMITTEE

ModWright Instruments, Inc. PH 150 Tube Phono Stage Owner s Manual

HDO701 FIBRE OPTIC TRANSMITTER

Dish Diversity Switch

Headend Optics Platform (CH3000)

Low Profile Digital HDTV Over-the-Air Antenna CONTENTS

COHERENCE ONE PREAMPLIFIER

One channel video link With duplex data and contact closure

Four-way Return Optical Receiver Manual. Transmitter OP-OR124RJ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 1)

AMERICAN NATIONAL STANDARD

TRFM Series RF Amplifier Module

JACK Digital HDTV Over-the-Air Antenna

SAWM60 AUDIO/VIDEO MODULATOR

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split

4320 SS-25 Self-Strip Terminating Block

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

3M Coupling Tray FDTC-10S-COUPLINGTRAY

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

INSTRUCTION MANUAL ALP690. Active LPDA Antenna. Fill in for your records: Serial Number: Purchase Date: Rio Rancho, NM, USA

TV Radio Multimedia. Optical Nodes, 1218 MHz and 1006 MHz amplifiers, distribution and connection technology

SHF Communication Technologies AG,

Register your product and get support at SDV5122/27. EN User manual

3 SLiC Aerial Closure with Rubber End Seal

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

D3.1/CCAP Compliant HFC. Enhance. QHFCN CATV Optical 2-way Mini Node INSTALLATION & OPERATION MANUAL.

CGA0101 Wireless Cable Gateway Quick Installation Guide

I N S T R U C T I O N D A T A

JACK Digital HDTV Over-the-Air Antenna w/built-in SureLock Digital TV Signal Meter

HFC. Enhance. QHFCN CATV Optical 2-way Mini Node Installation & Operation Guide

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

HMA-860H AGILE MODULATOR

Low Profile Digital HDTV Over-the-Air Antenna CONTENTS

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

The Art of Engineering

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

In-Wall Control Mount for ipod Touch

2015 OPTICAL TRANSMITTERS

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

Cisco GS7000 High-Output (GaN) 4-Way Segmentable Node with 85/102 MHz Split

USB-TG124A Tracking Generator User Manual

Headend Optics Platform (CH3000)

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

OA White OA Black. Owner s Manual. Low Profile Digital HDTV Over-the-Air Antenna. w/built-in KING SureLock Digital TV Signal Meter

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT


3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

Fiber Meter. Specification & User Manual

3M No Polish Jacketed SC/APC Connector

ST-4000 SIGNAL LEVEL METER

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

EC Series Creativity Accessories Safety and Installation Guide

Typical applications:

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

Assembly Level Service Guide

CABLE TV on fiber. CABLE TV FIBERLINK Pass 100+ TV channels on 1 SingleMode fiber with no need for amps

SCIR. Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight SCIR

Chameleon Labs Model 7720

SLiC Fiber Aerial Closure System

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial


INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Transcription:

27.3.2012 1(12) CXX Series User Manual Teleste Corporation CXE810 Fibre optic receiver

27.3.2012 2(12) Contents Introduction... 3 Installation... 3 Housing... 3 Powering... 4 Interfaces... 4 Fibre installation... 5 Front panel... 6 Features... 7 Forward path / Optical receiver... 7 Legal declarations... 11

27.3.2012 3(12) Introduction The CXE810 is a fibre deep optical receiver. It is designed for cases which do not need optical transmitter. It is an attractive option for areas where costefficiency and easy installations are prime concerns. The integrated optical receiver supports light wavelengths from 1290 nm to 1600 nm. Alignment of this product is easy. The Optical Level Control (OLC) as well as gain and slope adjustments use electrical controls that improve the reliability of this fibre optic receiver. Plug-in accessories are not needed in normal oneoutput operation. Installation The RF output can be split easily in the field within matter of minutes, and a full range of taps/splitters are available. Housing 8912024 Figure 1. CXE810 housing dimensions - side and top view The CXE810 can be installed either into a street cabinet or to a sheltered outdoor environment. Note: Fibre adapter is not waterproof. The class of enclosure is IP43. The amplifier should be installed in a vertical position so that the external cable connectors are underneath. At least 100 mm of free space should be left above the amplifier to ensure sufficient cooling air circulation. The housing should be grounded with at least 4 mm 2 grounding wire (Cu) from a proper earth to the grounding point. The cover of the housing is closed by a single bolt. There are no hinges. Open cover is to be removed completely. Using 4 mm Allen key, the retaining bolt is fasten with a tightening torque of 2.5...3.5 Nm. Before closing the lid ensure that: nothing is trapped between the lid and the case all case gaskets are in their correct positions lid seats evenly on the rubber gasket The class of enclosure is IP43 when correctly installed and tightened.

27.3.2012 4(12) Powering The locally powered CXE810 fibre optic receiver is connected to the main voltage of 165 255 V AC via its own power cord. The power supply is double shielded and does not require separate grounding. However, the amplifier housing has to be grounded from the grounding point. The supply voltage fuse (T3.15 A / 250 V / TR5) is located on the upper right corner of the amplifier, beneath the shroud of the power supply unit. Interfaces Underneath the CXE810 fibre receiver are one optical fibre port with fibre adapter and one RF output port with F-female connector. The coaxial output has a standard PG11 thread and they accept any KDC type adapter or connector. The length of centre conductor is illustrated in Figure 3. 8912032 1 2 3 4 5 Figure 2. CXE810 Fibre Optic Receiver, 1) Optical fibre input port, 2) Ground, 3) Optional RF output port, 4) RF output port, 5) Power inlet 8905010 Figure 3. Centre conductor length

27.3.2012 5(12) Fibre installation The CXE810 fibre optic receiver comes as standard with a bulkhead mounted SC/APC adapter. Fibre installation is a critical procedure and it should be done carefully. Incorrect handling of the fibre can result in damage and degraded performance. The shielding cover of the node provides a protective enclosure for optical fibres and components. Warning: The SC/APC adapter is connected to the integrated fibre receiver through a short length of fibre on the rear side of the bulkhead. To avoid damage to the fibre, take care not to rotate the adapter when installing or removing the fibre connector. Cleaning fibre connectors For correct optical operation ensure that all optical connectors are cleaned immediately before mating using a suitable optical connector cleaning kit. If a cleaning kit is not available, wipe the end of the connector using pure isopropyl alcohol (99%) and a lint-free wipe. Dry it with filtered compressed air. Wait until dry to insert connector into the adapter. When fibre optic connectors are unmated, the optical fibre end faces must be protected from contamination using suitable dust caps. Contamination of fibre end faces will reduce the performance of the optical fibre and could ultimately cause failure of the system. Contamination could also damage the fibre end faces when the connectors are mated.

27.3.2012 6(12) Front panel 8912016 1 5 2 3 6 4 10 9 8 7 Figure 4. CXE810 front panel 1) Integrated optical receiver 2) Indicator for optical input power 3) Optical power DC voltage test point 4) Level adjustment 5) Output test point, -20 db directional coupler 6) Output module 7) RF output port 1 8) RF output port 2 9) OLC mode jumper 10) Slope selection jumper OLC mode jumper (Figure 4 pos. 9) Slope selection jumper (Figure 4 pos. 10) OLC ON 10 db slope OLC OFF flat Figure 5. Jumper configurations

27.3.2012 7(12) The front panel contains up/down push buttons for output level adjustment and a vertical 9 segment LED light bar with corresponding adjustment indication. The level adjustment range from 0 db to -16 db in 1 db steps. Even db values are indicated by a single LED and odd values with two LEDs. The adjustment value can be marked on the front panel with a permanent marker for later reference. Output level adjusted to 0 db Output level adjusted to -5 db Output level adjusted to -16 db Table 1. CXE810 optical receiver, output level adjustment indicator. Features Forward path / Optical receiver The optical receiver is integrated within the CXE810 and will accept both 1310 and 1550 nm wavelength optical inputs. The optical receiver provides both LED indicator and DC voltage test point for received optical power to quickly determine status of the unit. The output stage uses a GaAs MESFET output amplifier to improve RF performance over the entire 47 to 1006 MHz passband. The optional RF output can be set up for a variety of output configurations. Refer to the Table 1. Output modules. Output module Attenuation at 1000 MHz RF output port 1 RF output port 2 AC6112 1.8 db 12.5 db AC6116 1.0 db 16.0 db AC6119 1.0 db 20.0 db AC6124 4.0 db 4.0 db AC6128 2.0 db 8.9 db Table 2. Output modules. Optical input power

27.3.2012 8(12) Optical input power can be measured from the optical power DC voltage test point (Figure 4 pos. 3). The test point DC voltage is directly proportional to optical input power in mw e.g. 10 V corresponds to 1.0 mw average optical power for 1310 nm. Chart below shows the correct measurements at the test point using a 1310 nm or 1550 nm transmitter. Chart 1. CXE810 optical receiver, expected levels. Do not connect any voltage to the test point or short circuit it to ground. Use a voltage meter with an input resistance higher than 100 kω.

27.3.2012 9(12) The mainboard provides also a LED indicator (Figure 4 pos. 2) which gives a visual indication of the optical input power. Optical power LED Yellow Green Red Condition Optical input power is below -7 dbm Optical input power is within the nominal range (-7 0 dbm) Optical input power exceeds 0 dbm Table 3. LED indicator for optical input power on CXE810. Forward path adjustment The following are instructions to be used for a normal adjustment procedure. 1. Test the optical input power present on the fibre service cable using an optical power meter. The CXE810 integrated optical input power range is from -7 dbm to 0 dbm. 2. Apply the power 3. Optical Level Control (OLC) circuitry provides gain control that compensates for changes in input level caused by external variations. The available gain reserve is factory-set for optimum operation. If needed the output level can be adjusted with the midstage attenuator. If OLC is disabled with the internal jumper (Figure 4 pos. 9) the CXE810 optical receiver can be operated at full gain for applications that do not require gain stabilization. 4. Use the level adjustment keys to get wanted output level. The LEDs will indicate the output level. The network plan should specify exact signal levels. Refer to the Table 5 or Table 6. Output level without OLC (dbµv) Level adjustment (db] 120 0 119-1 118-2 117-3 116-4 Table 4. Level adjustment without OLC when input power is -2 dbm at 4 % OMI.

27.3.2012 10(12) Output level with OLC (dbµv) Level adjustment (db) 115 0 114-1 113-2 112-3 111-4 Table 5. Level adjustment with OLC when input power is between 0-7 dbm at 4 % OMI. 5. Use the response mode jumper (Figure 4 pos. 10) to select the midstage slope. Available options are flat or 10 db sloped. 6. Connect the fibre connector to the bulkhead adapter. 7. The adjustment value can be marked on the front panel with a permanent marker for later reference.

27.3.2012 11(12) Legal declarations Copyright 2011 Teleste Corporation. All rights reserved. Teleste is a registered trademark of Teleste Corporation. Other product and service marks are property of their respective owners. This document is protected by copyright laws. Unauthorized distribution or reproduction of this document is strictly prohibited. Teleste reserves the right to make changes to any of the products described in this document without notice and all specifications are subject to change without notice. Current product specifications are stated in the latest versions of detailed product specifications. To the maximum extent permitted by applicable law, under no circumstances shall Teleste be responsible for any loss of data or income or any special, incidental, consequential or indirect damages howsoever caused. The contents of this document are provided "as is". Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy, reliability or contents of this document. Teleste reserves the right to revise this document or withdraw it at any time without notice. WEEE Notice This product complies with the relevant clauses of the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). The unit must be recycled or discarded according to applicable local and national regulations. European Conformity This equipment conforms to all applicable regulations and directives of European Union which concern it and has gone through relevant conformity assessment procedures. Teleste Corporation P.O. Box 323 FI-20101 Turku FINLAND www.teleste.com

www.teleste.com MCC201 User manual 63