Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Similar documents
Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

LVM LASER VALVE MOTION measurement system LASER-BASED TECHNOLOGY. SIMULTANEOUS, REAL-TIME DISPLACEMENT, VELOCITY and ACCELERATION ANOLOG OUTPUTS

Detailed Design Report

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Lt DELTA USA, Inc

Standard Operating Procedure of nanoir2-s

Connection for filtered air

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

Screen investigations for low energetic electron beams at PITZ

Amorphous Alloys for Transformer Cores

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Industrial Diode Laser (IDL) System IDL Series

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

CHEETAH-X Compact Picosecond Laser. Customized systems with SESAM technology*

SC26 Magnetic Field Cancelling System

GFT Channel Digital Delay Generator

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

Operating Instructions

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

Operation Procedure for Phillips XL30 ESEM

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

OM2000N INSTALLATION MANUAL

CBF500 High resolution Streak camera

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

Contents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2.

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

Measurement of Microdisplays at NPL

Figure 1. MFP-3D software tray

PRINCIPLES AND APPLICATIONS

DPD80 Infrared Datasheet

SPACESCAN SERIES SS 02

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

LEP400 Etch Depth Monitor Real-time, in-situ plasma etch depth monitoring and end point control plus co-linear wafer vision system

DA : Series of Narrowband or Wideband Distribution Amplifiers

Digital SWIR Scanning Laser Doppler Vibrometer

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

Magnetic Sensor - Incremental EHP

Spectroscopy Module. Vescent Photonics, Inc E. 41 st Ave Denver, CO Phone: (303) Fax: (303)

Requirements for the Beam Abort Magnet and Dump

Maintenance/ Discontinued

LASER REGISTRATION FORM (LS-1)

CPD LED Course Notes. LED Technology, Lifetime, Efficiency and Comparison

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Electro-Optic Beam Deflectors

In-process inspection: Inspector technology and concept

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

DA E: Series of Narrowband or Wideband Distribution Amplifiers

PicoScope 3000 Series Automotive User guide

Digital SWIR Scanning Laser Doppler Vibrometer

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

CHAPTER 4 OSCILLOSCOPES

XB-68 RF Detector & Camera Finder

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

Altman Lighting Spectra Cyc 50 Specification

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

ED5229GT-E Series. Page 1 of 8

DPD80 Visible Datasheet

PicoScope 4000 Automotive PC Oscilloscopes

Operation Manual for. SCU1 Signal Conditioning Unit

IMPAC Infrared Thermometers

Cylindrical Photoelectric Sensor CY-100 SERIES

These are used for producing a narrow and sharply focus beam of electrons.

NONDESTRUCTIVE INSPECTION OF A COMPOSITE MATERIAL SAMPLE USING A LASER ULTRASONICS SYSTEM WITH A BEAM HOMOGENIZER

PHI 5000 VersaProbe TM Operator s Guide

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

OPTICAL POWER METER WITH SMART DETECTOR HEAD

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

Leica TCS CARS. Live Molecular Profiling Technical Documentation. Living up to Life

Vibration-Free Pulse Tube Cryocooler Systems for Gravitational Wave Detectors II II

Click to Print This Page. 9,500 ANSI / 10,500 ISO Lumens Contrast Ratio: 10,000:1 (Dynamic Black) 1,000:1 native Part Number:

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

40-Meter Subsystems: As LIGO-Like as Possible

CHAPTER 3 OSCILLOSCOPES AND SIGNAL GENERATOR

W100L: Laser Sensor in Mini- Format

RX40_V1_0 Measurement Report F.Faccio

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

Recent APS Storage Ring Instrumentation Developments. Glenn Decker Advanced Photon Source Beam Diagnostics March 1, 2010

LUT Luminescence scanners: Seeing what no-one else can

Shock and Vibration Tests on SmartScan Interrogators to ISO :

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Mahdad Manavi LOTS Technology, Inc.

Transcription:

Durham Magneto Optics Ltd NanoMOKE 3 Wafer Mapper Specifications

Overview The NanoMOKE 3 Wafer Mapper is an ultrahigh sensitivity Kerr effect magnetometer specially configured for measuring magnetic hysteresis loops and domain images across the entire surface of large area samples. It is ideally suited for wafer-scale development and manufacture of MRAM, magnetic sensors and advanced materials. The NanoMOKE 3 Wafer Mapper is built around Durham Magneto Optics Ltd s well-established NanoMOKE 3 optical head. The optical head contains a temperature- and current-stabilised 660nm laser, galvanometric deflector mirrors, polarisation analysis optics and a high-sensitivity, highresolution digital camera with high intensity 660nm incoherent imaging light source. Together, these components allow state-of-the-art hysteresis loop measurement and excellent quality domain imaging. The Wafer Mapper uses a horizontally mounted motorised wafer stage which can move 200mm in x and 196mm in y. A projected field electromagnet mounted beneath the wafer applies fields of up to 0.3T in any in-plane direction (for in-plane magnetised samples) or in the z-direction (for out-of-plane magnetised samples). Because the electromagnet sits beneath the sample, there are no limits on sample size or movement imposed by the pole pieces of the electromagnet. All optics and mechanics sit on a vibration isolating optical table, allowing the system to be used in normal laboratory environments. A 19 control rack sits next to the table and contains a PC, the NanoMOKE 3 optical head controller and the electromagnet power supply. The NanoMOKE 3 Wafer Mapper

Loading a 200mm wafer into the NanoMOKE3 Wafer Mapper Software The NanoMOKE 3 Wafer Mapper uses the same software application as the standard NanoMOKE3 system: LX Pro3. This application allows hysteresis loops to be measured, topographic and domain images to be captured and loop measurements to be automated across the surface of the wafer. Once loops have been measured from different points across the wafer, LX Pro3 automatically analyses the loops for coercivity, field offset, remanence, amplitude and reflectivity and plots a map of the sample surface. The hysteresis loop underlying any pixel in the map is automatically loaded by clicking that pixel. An intelligent filter checks each loop against reflectivity and Kerr amplitude thresholds in order to remove any measurements made off the edge of the sample or on damaged areas.

Mapping remanence ratio across a 100mm permalloy wafer A special software feature allows pseudo domain images to be constructed by plotting the Kerr signal at a given field point number from each loop simultaneously. As one steps through consecutive field points magnetic switching across the entire wafer is seen.

Observing magnetic switching across a 100mm permalloy wafer. The hysteresis loops on the right are measured in the centre of the wafer. The point highlighted in red is the field point chosen for the wafer-scale image on the left. One sees that magnetic switching starts at the top of the wafer and sweeps down the left hand half as one steps between successive field points.

Variable temperature measurements Temperature-dependent measurements (room temperature and above) can be made using the gas heater option of the NanoMOKE 3 Wafer Mapper. When fitted, this option places a gas heater pipe close to the surface of the wafer causing hot argon or nitrogen gas to flow onto the wafer at the point where the laser spot is focused allowing measurements between room temperature and 400 C to be made. Making elevated temperature measurements under hot gas flow. The picture shows the gas heater pipe with its red-hot filament visible in its reflection in a 200mm wafer. Magnetic field By default the NanoMOKE 3 Wafer Mapper has a maximum applied field strength of 0.3T. This is usually sufficient to allow full hysteresis loops to be measured from exchange-biased systems and to saturate along the hard axis of most spintronic materials. A pulsed field option is available to increase this maximum applied field strength to 0.8T (in-plane and out-of-plane). Magneto-optics Detachable lens on the front of the NanoMOKE 3 optical head allows the optical configuration to be changed between longitudinal / transverse Kerr effect (45 beam incidence) and polar Kerr effect (0 beam incidence).

The NanoMOKE 3 optical head is sensitive to longitudinal Kerr effect, polar Kerr effect and transverse Kerr effect and can detect Kerr rotation and Kerr ellipticity. Typical noise levels are <0.5mdeg rms for Kerr rotation and ellipticity and <0.005% rms for transverse Kerr effect (200ms loop acquisition time). Measuring free layer hard axis anisotropy (left) and the full hysteresis loop of an exchange-biased spin valve (right). Samples courtesy of Ricardo Sousa, Spintec, Grenoble. Technical specifications Laser Class 3R red (660nm, <5mW) solid state laser diode with noise cancellation system. Intensity noise < 0.005% rms. Polarisation noise < 0.5 mdeg rms. Multiple averages of a hysteresis loop can be taken and combined to further reduce noise. The auxiliary laser input port allows external lasers supplied by the user to be used in place of the internal laser. Permitted wavelength range for external laser: 400-700nm. Magnetometry Laser can be fixed on any point on the sample surface and hysteresis loops measured at that point. Position of laser on sample surface is selected by double-clicking a frozen video image in the software. Electromagnet Projected field electromagnet mounted beneath the sample surface. ±0.3T in-plane and out-of-plane maximum field strength. The in-plane direction can be manually selected by rotating the electromagnet. Water cooling required. Flow rate monitor and automatic shut-down of power supply (with software indication) in the event of flow failure provided. ±0.8T pulsed field available as an option. Full specifications to be announced later. Auxiliary inputs and outputs Two auxiliary analogue inputs (±10V, 16-bit resolution) and two auxiliary analogue outputs ((±10V, 16-bit resolution) are provided. The inputs are Magnetooptical effects Kerr signal and reflectivity are recorded simultaneously. With any of the polar objective lens attached, the laser beam is incident on the sample with an average angle of zero degrees and polar Kerr rotation / ellipticity can be recorded. With the longitudinal objective lens attached, the laser beam is incident on the sample with an average angle of 45 degrees and longitudinal Kerr rotation / ellipticity and the transverse Kerr effect (via the reflectivity signal) can be recorded. Kerr rotation and ellipticity are reported in actual millidegrees of rotation and reflectivity in actual percent. Field measurement The applied magnetic field is measured by a Hall probe

Imaging Two imaging modes: (i) Laser can be rastered under computer control to acquire real time images. Frame rates: 4 frames per second (highest speed); 1.8 frames per second (normal); 1 frame per 7 seconds (photograph). (ii) High sensitivity CCD camera with red incoherent light source. Image can be formed from Kerr signal or reflectivity. Background subtraction available to remove nonmagnetic structural features from image. Lens Objective lens for magnetometry and imaging externally mounted and detachable. Currently supplied lens: 50mm focal length standard polar Kerr lens. 32mm focal length standard longitudinal Kerr lens. Equipment footprint Optical table and legs: 1m 1m Electronic control rack: 0.7m 0.7m. It is recommended that enough space be left for user access on all sides of the system. Power requirements 220-240 V 8A AC 50Hz single phase or 110V AC 16A 60Hz single phase (specify at time of ordering) Standards All equipment is CE marked and conforms to EN61326. logged simultaneously with the hysteresis loop and can be used to measure other parameters from your own experimental set-up, such as temperature, magnetoresistance etc. The outputs can have arbitrary waveforms generated on them with 100 k- samples per second update rate and can be used to stimulate your sample during measurement. Loop acquisition The recommended looping frequency is 0.1 30 Hz. The allowed range is 0.01 70 Hz. Up to 3000 points per loop can be measured with 16-bit resolution. The system automatically adjusts the analogue sampling rate with sweeping frequency to optimise signal to noise ratio. Vibration isolation Passive air isolation system to separate optical table from vibration in the floor. Supplied with a manual pump to increase pressure. positioned close to the sample. The single-shot full-bandwidth AC noise on Hall probe measurements is <0.5G (0.05mT) rms; this decreases as loop averages are built up. Any offset on the Hall probes can be nulled using one of the supplied test samples. Field waveform generation Arbitrary waveforms can be generated on each of the X and Y field channels simultaneously, and synchronised with the Kerr acquisition. Waveforms can be updated at 100 k-samples per second, with a resolution of 16 bits. Temperature range An optional gas heater allows the region around the focused laser spot to be heated from room temperature to 400 C in a flow of hot argon or nitrogen gas. Benchmarking test samples Supplied with three test samples. The first is a 20nm thick Permalloy film structured into features of ~30µm width. The second test sample contains a continuous film of perpendicularly magnetised material to demonstrate the polar Kerr effect. The system is guaranteed to be able to perform real-time video-rate polar Kerr imaging of domains from this sample. The third test sample is an unstructured 20nm thick Permalloy film. The system is guaranteed to be able to measure loops with <1% rms noise (relative to amplitude of loop) with 10 seconds of acquisition time and to be able to perform real-time video-rate Longitudinal Kerr imaging of domains from this sample.

Service requirements and room layout System requirements: 220-240 V 8A AC 50Hz single phase or 110V AC 16A 60Hz single phase (specify at time of ordering) No excessive vibration. Ordering and deliverables Item NanoMOKE3 base system Deliverables NanoMOKE 3 optical head, including built-in 660nm class 3R laser, video-rate mirror rastering system, highresolution, high-sensitivity digital camera with red incoherent light source, longitudinal, transverse and polar Kerr effect detectors. 19 control rack containing PC with licensed Windows 7 32-bit operating system, NanoMOKE 3 controller with electromagnet power supply, master power switch, overcurrent circuit breaker. 32mm focal length standard longitudinal Kerr effect lens. 50mm focal length standard polar Kerr effect lens Fixed mechanical support for NanoMOKE3 optical head to mount in vertical plane. 0.3T projected field electromagnet including field measurement system configured for in-plane (any direction) and out-of-plane field directions. Passive air support optical table with manual pump for increasing pressure 200mm wafer motor (mounted in horizontal plane) LX Pro 3 software preinstalled Distributable copy of LX Lite 3 software which allows data to be processed on other computers

ImageJ open-source image processing software preinstalled All cables Three benchmarking test samples Full installation (half a day) and one day of user training Optional gas heater Gas heater (room temperature - 400 C) Borosilicate heat-proof glass plate on wafer motor Heater power control system with gas flow interlock Contact information Durham Magneto Optics Ltd, The Mountjoy Centre, Maple Wing, Durham University, Durham DH1 3LE UK E-mail: sales@durhammagnetooptics.com Web: www.durhammagnetooptics.com Durham Magneto Optics Ltd 2012. NanoMOKE is a registered trademark of Durham Magneto Optics Ltd. Specifications subject to change without notice. This edition published December 2012.