VISUALIZED DIGITAL TIMER

Similar documents
CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

02/11/2015

REGO Start&Go USER MANUAL

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL

Operating instructions Electronic preset counter Type series 717

MULTIS L72. Operating instructions

Synchronization Check Relay ARGUS 7

Digital differential Pressure switch Model DPS Instruction manual

XTM72 Exerciser Timer Module

Multifunction Digital Timer

Single Axis Position Controller

E R A I GATE OPENERS DEPARTMENT

MARCO CORNER, 19/ THIENE (VI) ITALIA

Kuhnke Technical Data. Contact Details

Flexible Counter Series in DIN size 24 x 48 mm

F90 Series (Rate Indicators / Controllers) INSTRUCTION MANUAL

Operating Instructions

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

7 Day Digital Time Switch

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

PRINCIPLES AND APPLICATIONS

Digital Time Switch. Installation & Operating Instructions

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Electronic Pulse Counter Combination device


Installer manual. RS17.P Control panel for swing gates at 24 V DC with encoder EKKO 204D

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Eaton Durant. Counters, process instruments and hour meters.

Digital differential pressure controller Model DPD Instruction manual

XTM72E & F Real-Time Clock Modules

MULTIS LMp / LMg. Systèmes de Coupure et de Protection Switching and Protection Systems

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

DCP100 Digital Control Programmer Specifications

Unicable II Programmer. IDLU-PROG01-OOOOO-OPP Item: Installation & User Guide

Operating instructions - High Performance LED Timer / / /

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

multi-function meters

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

AT450SAW Programmable Selective Amplifier

Innovative Air Systems ABN When Calling For Support Quote:.doc

Flexible Counter Series in DIN size 24 x 48 mm

SAUTER flexotron RDT405 Manual

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

Model IQ4-PC User Manual Revision Date:

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

A B C D. Call-way AB

Junior Max (JR Max ) Controller

VAT 20 Adjustable Frequency Drive

Henkel Installation Handbook LINEGUARD 2001

EA350. Generator Automatic Voltage Regulator Operation Manual

Sequential and Combination Timer TK-415 with RS-232 communication

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

CAM PROGRAMMER MCA 116

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

263 Series LED Bargraph Indicator and Controllers

Time-Lag Relays. User s Handbook (General Model)

Bulletin 190 IEC Modular Starter System

Turnout Decoder TD Maxi. User Manual - version 0.1.6

Intelligent Security and Fire Ltd

Simply clever! The digital DIN-rail time switches by Grässlin

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

Radio Thermostat Clock

Preset counters, electronic

DIRECT DRIVE ROTARY TABLES SRT SERIES

AT47SAW Programmable Selective Amplifier

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

ex 800 Series ematrix System

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

ATS50SAW Programmable Selective Amplifier

Instruction manual. DALI Gateway art Installation manual

SERVICE MANUAL COOKING. Built-in ovens. S.E.T. (Simple Electronic Timer) Electronic Programmer. Publication Corso Lino Zanussi,30

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Operating instructions. Universal timer switch display

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

Gamma instabus. Technical product information

Standard RS232 RS ma

User Guide. Centrex Recording Interface

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

Label Applicator HERMA 400

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

MULTITURN ABSOLUTE ENCODER EAM PROFIBUS

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

WE-EF LEUCHTEN. Technical information for Eco Step Dim Basic. Product ID

SAT IF distribution system

TruVision High Definition TVI Vandal Dome Installation Guide

Transcription:

CET VISUALIZED DIGITAL TIMER WITH ONE SET POINT Type: NTM52 THE INSTRUMENTS OF SERIES NTM ARE DIGITAL INSTRUMENTS WIDE USABLE IN THE INDUSTRY FOR THEIR PROGRAMMABLE CHARACTERISTICS AND THE FLEXIBILITY OF THEIR EMPLOYMENT. NTM52, TIMER WITH ONE PROGRAMMABLE SET POINT AND TWO RELAY OUTPUTS. MOREOVER, IT S AVAILABLE A TOTALIZER OF THE TIME. GENERAL FEATURES Frontal keyboard in polycarbonate (antiscratch, antioil, antacid). IP65 protection degree Accessible parameters with key software Removable terminals connection. Execution DIN 72 x 72. Recessed assembly. Special retaining brackets. PROGRAMMABLE PARAMETERS One Set Point Automatic Time Reset 4 Time Scales UP / DOWN / SUPERIOR Timing Memory Reset Key Input Selection OUTPUT Mode Selection TECHNICAL CHARACTERISTICS POWER SUPPLY IN ALTERNATE CURRENT POWER SUPPLY IN DIRECT CURRENT POWER SUPPLY TOLERANCE ABSORPTION OPERATING TEMPERATURE CLIMATIC CONDITIONS TIMINGS VISUALIZATION TIMINGS SCALES INPUT AUXILIARY INPUTS POWER SUPPLY COMMAND IMPUTS OUTPUTS RELAY RESET PROGRAMMED DATA MEMORY : Single power 24-110 - 230 Vac (50 / 60 Hz). : Single power 24 Vdc : +10% - 15%. : 2 W - 3 VA. : -5 C + 55 C. : U.R. 95 % at 40 C (without condensate). : 5 digits, 11 mm high : 999h59m - 9h59m59s - 9m59s99c - 999s99c : programmable as Continuous; Impulsive, Start/Stop : 24 Vdc - 80 ma available on terminals. : 1 Start - 1 Reset Timing - 1 Inhibit Timing (Inhibit). : 2 relays with operating contacts; capacity 2A - 250Vac. : Manual or automatic with excitation time from 0,1 to 99,9 sec. : static (without battery) CET - s.r.l. Vers. 1.1 NTM 52 Pag. 1

DESCRIPTION OF THE FRONTAL KEYBOARD ø WHITE ù WHITE ú BLUE û GREEN The key 'LEFT ARROW' in normal operating phase visualizes, blinking, all the programmings executed without the limitation of the insertion code. The time of scansion of the programmings is given from the pressure of the same key. It exits automatically from this phase after 5 sec of the last pressure of the same key. In programming phase it moves the cursor of the figure towards left of a step, than at the beginning it is on the right side first one on the. At the end it resumes from the first one to right. The key 'UP ARROW' in normal operating phase it enter and exit to the Totalizer. In programming phase it increases the value of the blinking figure. The key 'PRG' pressed for 2 sec. allows to enter in the programming phase, visualizing on display C.0000. In the programming phase, pressing key 'PRG' impulsively, it exits from the programming phase. The instrument exits automatically from the programming phase, 60 sec. after the pressure of the last key. The key 'ENT/RES' in normal phase of counting has the 'RESET' function, with the modalities to it attributed in the programming phase. In programming phase it confirms and memorizes the visualized data and passes to the successive function. If it has arrived to list end it resumes from the beginning. INPUTS / OUTPUTS DESCRIPTION DC POWER SUPPLY (inputs 7-8) AC POWER SUPPLY (inputs 5-6) 24 VDC - 80mA (inputs 9-10) (input 11) RESET (input 12) INHIBIT (input 13) RL1 (inputs 1-2) RL2 (inputs 3-4) 24VDC Power Supply Input of the instrument. AC Power Supply Input of the instrument; it can be to 24-110 - 230 VAC in according to demand. 24 VDC 80 ma auxiliary Power Supply that the instrument supply to feed the Encoder and amplified proximity. Input that execute the timing starting as the programming mode; it s configurable in Positive () or Negative () logic by the dip switches on the rear. RESET Input that execute the timing reset; it s configurable in Positive () or Negative () logic by the dip switches on the rear. INHIBIT Input that execute the timing Inhibit; it s configurable in Positive () or Negative () logic by the dip switches on the rear. Output of Relay 1, connected to the operation of the Set Point S2. The Common and Normally Opened contacts are available. Output of Relay 2, actives during the timing. The Common and Normally Opened contacts are available. DESCRIPTION OF THE LED s OPERATION LED 1 It comes activated to the reaching of the Set Points S1. LED 2 Actives during the timing. CET - s.r.l. Vers. 1.1 NTM 52 Pag. 2

For SET POINT programming access, proceed as follow: - Press key PRG in impulsive mode; on display appears: Ë1 < 0 20 SET POINT PROGRAMMING S.1 = SET POINT 1, main Set Point, programmable between 1 cent and 999h59m (depending to the selected scale). If programmed = 0 the Set Point remains excluded and the instrument works like a totalizer and predisposing the count in UP mode. Key ENT confirms the data. In order to exit the programming, press key PRG. PROGRAMMING OF THE OPERATION PARAMETERS The programmable parameters are divided in two groups and protect with a 4 figures code. In order to approach the programming, proceed in the following way: - Press key PRG for about 2 sec. On the display appears: Cod 0000 Ìê9²9 GROUP 1 : in order to approach the parameters of group 1, insert code 2357 and press ENT t.r. = Time of Automatic Reset, programmable from 0.0 to 99.9 sec. This parameter allows to make to work the instrument in automatic mode. When the timing arrives to the value of S.1, it automatically resets the count, excites the RL1 relay and it resumes to count. The RL1 relay remains excited for the set up time in t.r. If the time of reset is programmed = 0 (0.0) the instrument gets ready to works in manual mode. Particular cases: if the set up time t.r. is bigger than the time employed to the timing to arrive to the values of S.1, the relay will never come unactived. SCÄ 1 Cæ UP Cæ dæ Cæ SÈ SCL. = Time Scale. Selection of the maximum time scale of the timing. It s possible to choose between 4 different time scales: 1 = 9m59s99c - 2 = 9h59m59s - 3 = 999h59m - 4 = 999s99c Count UP / DOWN / Superior. Count = Up: Up; the timer gets ready to visualize the timing in increasing way (UP), starting from zero up to the programmed value of set point. To the end of timing it works in Manual or Automatic mode, as programmed in t.r. function. Count = dn: Down; the timer gets ready to visualize the timing in decreasing way (DOWN), starting from the programmed value of set point to zero. To the end of timing it works in Manual or Automatic mode, as programmed in t.r. function. Count = Sp: Superior; the timer gets ready to visualize the timing in increasing way (UP), starting from zero up to the programmed value of set point. To the end of timing it works in Manual mode and the timing goes on up to a new command (, RESET, INHIBIT). CET - s.r.l. Vers. 1.1 NTM 52 Pag. 3

PROGRAMMING OF THE OPERATION PARAMETERS The programmable parameters are divided in two groups and protect with a 4 figures code. In order to approach the programming, proceed in the following way: - Press key PRG for about 2 sec. On the display appears: Cod 0000 NeÆon NeÆoF RreË 0 reë 3 Iæ Á Iæ» Iæ Ë Auto Á Auto ¾ 0í1 î 0í1 ¹È È ¹È ê GROUP 2 : in order to approach the parameters of group 1, insert code 2413 and press ENT Active or excluded memory. This parameter allows to program the saving of the current counter value during the power off the instrument. MEM.on. = memorization of the count during the power off. When power on the instrument the display will visualize the last present value in the power off phase. MEM.of. = excluded memorization of the count; every time that the instrument comes powered off and then powered on the count comes lost and the instrument restart always from the initial condition. Function of RESET Key ; this programming enable and disable the RESET function of the RES frontal key during the normal timing: RES. 0 = RESET function of the RES key disabled RES. 1 = RESET function of the principal timing only RES. 2 = RESET function of the global timing only RES. 3 = RESET function of the principal and global timings Programming of the Input. This programming allows to Start the timing in three different modes: In. I. = Impulsive Mode; the timing starts with the impulsive closing of the input. In. C. = Continuously Mode; the timing starts with the closing of the input; the timing is interrupted every time the input comes opened. In. S. = Start/Stop Mode; the timing starts with the impulsive closing of the input and it stops to the subsequent closing. Closing another time the input the timing resume and it stops to the subsequent closing. Programming of the Automatic Reset Mode This parameter allows to activate the timing to the beginning or the end of the programmed time of the Automatic Reset. Auto I. = Activation of the timing to the beginning of the Automatic Reset Time Auto F. = Activation of the timing to the end of the Automatic Reset Time Programming of the OUTPUT RL1. This parameter allows to activate the RL1 relay during the timing î or at the end of the timing. Ou.1. î = Activation of the RL1 relay at the end of the timing Ou.1. = Activation of the RL1 relay during the timing Activation mode of the programmed parameters. With this programming is possible to activate the executed programmings directly to the exit of the programming or, when exited of the programming, after a RESET (with frontal key or from rear input) A.P. = P. Activation of the parameters to the exit of the programming. A.P. = r. Activation of the parameters to the exit of the programming after a RESET. Pressing the key ù the totalizer of time will be visualized for 5 sec. Toì 0 00 The totalizer visualizes the total time that the instrument has show. It can be resetted through frontal key RES or from RESET input when it is visualized on the display. CET - s.r.l. Vers. 1.1 NTM 52 Pag. 4

DECLARATION OF CE CONFORMITY CE NORMATIVE CONFORMITY Borgolavezzaro, October, 03rd 2005 The building firm: CET s.r.l. Head office: Strada Statale 211, Km 53,3 28071 Borgolavezzaro (No) ITALIA declare that the products: Tel. 0039 - (0)321-885301 Fax. 0039 - (0)321-885560 type : Electronic Timer model: NTM 52 use class: Industrial are in conformity with the following normatives: EN55011 ENV50141 ENV50204 EN61000-4-2 EN61000-4-4 The manufacturing: CET s.r.l. Signature CET - s.r.l. Vers. 1.1 NTM 52 Pag. 5

Programming Notes CET - s.r.l. Vers. 1.1 NTM 52 Pag. 6

Programming Notes CET - s.r.l. Vers. 1.1 NTM 52 Pag. 7

CONNECTIONS INPUT SIGNALS PROGRAMMING PROGRAMMING RESET 24 VDC INHIBIT 11 10 11 9 11 10 11 9 + - 9 10 11 12 13 14 CONTACT CONTACT TTL LOGIC TTL LOGIC 1 2 3 4 5 6 7 8 RESET INHIBIT RESET INHIBIT RL1 RL2 + - POWER SUPPLY VAC 24 VDC 12 10 13 10 12 9 13 9 OVERALL DIMENSIONS (mm) FRONT 72 REMOVABLE TERMINAL SIDE RETAINING BRACKETS 10 MAX electronic timer 36952 RL1 RL2 è 72 67 PROG ENT RES CET NTM 19 85 9 113 REAR 67 DRILL TEMPLATE 9 10 11 12 13 14 67 68 1 2 3 4 5 6 7 8 68 CET CET CET CET s.r.l. Strada Statale 211 Km 53,550 28071 Borgolavezzaro - NO - ITALY Tel : ++39 0321-885180/885301/885807 Fax : ++39 0321-885560 info@cet-italy.com www.cet-italy.com Agent: CET - s.r.l. Vers. 1.1 NTM 52 Pag. 8