Enclosing the STB Island

Similar documents
HART STB Multiplexer Applications Guide

IP 20 distributed inputs/outputs Advantys STB. Catalog January

Advantys STB Standard INTERBUS Network Interface Module Applications Guide. 890USE17400 Version 2.0

STBXBA1000 Podstawa moduł WE/WY FORMAT I

Automation & Control Advantys STB IP20 Distributed I/O

Advantys Configuration Software

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Advantys STB Standard Profibus DP Network Interface Module Applications Guide. 890USE17300 Version 2.0

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Advantys STB Standard DeviceNet Network Interface Module Applications Guide. 890USE Version 2.0

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

OP5. Preprogrammed, configurable controller for simple applications

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Premium and Advantys STB on MB/TCP Advantys STB with Advantys FTB and Altivar on CANopen System User Guide [source code]

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Modicon STB IP 20 distributed inputs/outputs

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Datasheet - SRB301LC 24VAC/DC

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

AS09..S 3-pole Contactors - Spring Terminals

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

I/A Series Hardware Fieldbus Communications Module, FCM10Ef

I/A Series Hardware Fiber Optic LAN Converter

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

llen-bradley 194R-HM4-NFPA3

ALLEN BRADLEY TIMING RELAY

Ordering details. Approval. Classification

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Connecting cables for valves, Sub-D Type codes

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

Datasheet - SRB-E-201ST

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Generator protection relay

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

LED MODULES READYLINE DL

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Single-Output 2000 W

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Vaya Cove, Color. Data sheet. Philips Lighting Rev Burlington Woods Drive Burlington, MA 01803

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Fieldbus Components Section K

High performance circuit breakers

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

263 Series LED Bargraph Indicator and Controllers

Installation instructions Ex frames

Level Measurement silometer FMC 420, FMC 423

Gamma instabus. Technical product information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Fibre optic router for TP/FT-10 LRW-112PP

IndyGo Facility Upgrades Project 35671EE

Trusted 40 Channel 120 Vac Digital Input FTA

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

OT 100/ /700 P5

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

Trusted 40 Channel Analogue Input FTA

FP-QUAD-510. Features. Power Requirement OPERATING INSTRUCTIONS. 4-Axis, Quadrature Input Module

ODW-621. RS-232 Point-to-point applications

DLP200M 2 Relay Module for Heating and Cooling Plants

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Trusted 40 Channel 120 Vac Digital Input FTA

SH2RE16A4. Output relay module. Benefits. Description

Connecting cables for valves, round plug connectors Product range overview

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Quick-disconnect cables. Adjustable mounting brackets

HD-EXT2-C. HDMI over Shielded Twisted Pair Extender

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LONWORKS Fibre Optic Router

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Modular pulse operated latching relay 16 A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Magnecraft Power Relays

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Fibre Optic Modem ODW-611

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Wall-/Pipe-Mount Level Indicator

Transcription:

Enclosing the STB Island Open System Requirement All Advantys STB modules meet CE mark requirements for open equipment and should be installed in an enclosure that meets NEMA 250 type 1 requirements and IP 20 requirements conforming to IEC 529. The enclosure should be designed to prevent: unauthorized access personal injury resulting from access to live parts The specific environmental conditions under which the modules must operate should be considered in planning for the enclosure. Special consideration should be given to hazardous locations where a potentially explosive atmosphere (see page 35) may exist. NOTE: The majority of Advantys STB modules are certified for use in explosive environments. Refer to ATEX/FM Certified STB Modules (see page 37) for a complete list of modules. Size of the Enclosure The size of the enclosure is determined by the number of modules that will makeup the island. One NIM and a maximum of 32 I/O modules are permitted per island which can be: standard Advantys STB optional preferred optional standard CANopen In addition, PDMs, and an EOS or termination plate must be included in determining the total size of the island Standard Module Dimensions Advantys STB modules come in three different sizes and the dimensions for each of the sizes are listed in the following table. Module size Width of module alone Height of module in base Depth of module in base with field connectors 1 13.9 mm (.55 in.) 128.25 mm (5.05 in.) 75.5 mm (2.97 in.) 2 18.4 mm (.73 in.) 128.25 mm (5.05 in.) 75.5 mm (2.97 in.) 2-PDM 18.4 mm (.73 in.) 137.90 mm (5.45 in) 79.5 mm (3.13 in.) 3 28.1 mm (1.11 in.) 128.25 mm (5.05 in.) 70.1 mm (2.76 in) These depth and height dimensions do not take into account the dimensions of external power equipment, preferred modules and/or standard CANopen devices. 44 31002947 2/2009

The size and type of base for each of the Advantys STB modules is listed in the table on the following page. STB Modules Size & Base Type The following table lists the size and required base for each of the Advantys STB modules. Model Size Base Model Size Base Analog Input Modules Analog Output Modules 31002947 2/2009 45

Model Size Base Model Size Base STB ACI 0320 2 STB XBA 2000 STB ACO 0120 2 STB XBA 2000 STB ACI 1230 1 STB XBA 1000 STB ACO 0220 2 STB XBA 2000 STB ACI 1225 1 STB XBA 1000 STB ACO 1210 1 STB XBA 1000 STB ACI 1400 2 STB XBA 2000 STB ACO 1225 1 STB XBA 1000 STB ACI 8320 2 STB XBA 2000 STB AVO 0200 2 STB XBA 2000 STB ART 0200 1 STB XBA 1000 STB AVO 1250 1 STB XBA 1000 STB AVI 0300 2 STB XBA 2000 STBAVO 1255 1 STB XBA 1000 STB AVI 1270 1 STB XBA 1000 STB AVO 1265 1 STB XBA 1000 STB AVI 1275 1 STB XBA 1000 ------------------------ -- --------------------- STB AVI 1255 1 STB XBA 1000 ------------------------ -- --------------------- STB AVI 1400 2 STB XBA 2000 ------------------------ -- --------------------- Digital Input Modules Digital Output Modules STB DAI 5230 2 STB XBA 2000 STB DAO 5260 2 STB XBA 2000 STB DAI 5260 2 STB XBA 2000 STB DAO 8210 2 STB XBA 2000 STB DAI 7220 2 STB XBA 2000 STB DDO 3200 1 STB XBA 1000 STB DDI 3230 1 STB XBA 1000 STB DDO 3230 1 STB XBA 1000 STB DDI 3420 1 STB XBA 1000 STB DDO 3410 1 STB XBA 1000 STBDDI 3425 1 STB XBA 1000 STB DDO 3415 1 STB XBA 1000 STB DDI 3610 1 STB XBA 1000 STB DDO 3600 1 STB XBA 1000 STB DDI 3615 1 STB XBA 1000 STB DDO 3605 1 STB XBA 1000 STB DDI 3725 3 STB XBA 3000 STB DDO 3705 3 STB XBA 3000 -------------------- -- -------------------- STB DRC 3210 2 STB XBA 2000 -------------------- -- -------------------- STB DRA 3290 3 STB XBA 3000 Power Distribution Modules Special Purpose Modules STB PDT 2100 2 STB XBA 2200 STB EHC 3020 3 STB XBA 3000 STB PDT 2105 2 STB XBA 2200 STB EPI 1145 2 STB XBA 2000 STB PDT 3100 2 STB XBA 2200 STB EPI 2145 3 STB XBA 3000 STB PDT 3105 2 STB XBA 2200 STB XBE 1000 2 STB XBA 2000 -------------------- -- -------------------- STB XBE 1100 2 STB XBA 2000 46 31002947 2/2009

Spacing Requirements Adequate clearance must be maintained between the modules installed in the enclosure and surrounding fixed objects such as wire ducts and inside surfaces. The following two illustrations show the spacing requirements within an enclosure 31002947 2/2009 47

Mounting The island is mounted on one or more 35 mm wide DIN carrier rails. For EMC compliance, a metal DIN rail must be attached to a flat metal mounting surface or mounted on an EIA rack or in a NEMA cabinet enclosure. The physical backplane for the island is established by placing a NIM and a sequence of interlocked base units on the DIN rail (see page 18). The standard DIN rail is 35 mm x 15 mm deep. For DIN rail mounting requirements (see page 74) Wiring Wiring must not obstruct the 100 mm (3.94) of free air space above and below the island segment. All wires must be secured to prevent undue load or strain on the STB modules. As shown in the side view (above), all leads from a harness or cable channel must be dressed with a service loop to reduce strain on the module. Thermal Considerations For proper heat dissipation, allow a minimum clearance of 100 mm (3.94 in) above and below each island segment. The vent openings on top and bottom of the modules must not be obstructed. Listed below are some worst-case values for estimating the wattage dissipation when you plan the cooling for your system and cabinet enclosure: Module Type Module Width Worst-case Wattage Value inputs size 1 1.5 W size 2 2.0 W size 3 48 31002947 2/2009

Module Type Module Width Worst-case Wattage Value outputs size 1 1.0 W size 2 1.5 W size 3 special I/O size 2 2.5 W size 3 CANopen extension size 2 1.0 W EOS size 2 1.0 W BOS size 2 2.5 W auxiliary power supply size 2 2.5 W DC PDM size 2 1.5 W AC PDM size 2 1.5 W NIM The values above assume elevated bus voltage, elevated field-side voltage and maximum load currents. Typical wattage values are often considerably lower. 31002947 2/2009 49