Datasheet Daylight-Visible, General-Purpose Indicators for Indoor or Outdoor Use To view or download the latest technical information about this product, including specifications, dimensions, accessories, and wiring, see www.bannerengineering.com. Intense levels of light output for areas with high ambient light - even outdoors Viewable around entire perimeter; some models also emit light from top - or -, or -color models available Rugged, sealed thermoplastic housing rated for IEC IP67 and IEC IP69K Bright, even light V dc to 0 V dc or 85 V ac to 0 V ac (75 V dc to 0 V dc) or 00 V ac to 50 V ac (90 V dc to 0 V dc) operation, depending on model V dc operation useful for applications on mobile vehicles Consult factory for models with strobing capability WRNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Perimeter View Only Model Perimeter + Top View LED Color(s) Input Supply Voltage Connection K50BLGPQ K50BCLGPQ Green K50BLRPQ K50BCLRPQ Red K50BLYPQ K50BCLYPQ Yellow K50BLBPQ K50BCLBPQ Blue V to 0 V dc -pin M/Euro-style integral quick disconnect K50BLWPQ K50BCLWPQ White K50BLGRPQ K50BCLGRPQ Green / Red K50BLGRYPQ K50BCLGRYPQ Green / Red / Yellow V to 0 V dc K50BLGRYNQ K50BCLGRYNQ Green / Red / Yellow NPN V to 0 V dc 5-pin M/Euro-style integral quick disconnect K50BLG0Q K50BCLG0Q Green K50BLR0Q K50BCLR0Q Red K50BLY0Q K50BCLY0Q Yellow K50BLB0Q K50BCLB0Q Blue K50BLW0Q K50BCLW0Q White C 85 V to 0 V ac -pin /Micro-style integral quick disconnect K50BLG0Q K50BCLG0Q Green K50BLR0Q K50BCLR0Q Red C 00 V to 50 V ac vailable colors include: Green (G), Red (R), Yellow (Y), Blue (B) and White (W). Integral quick disconnect models are listed. To order the 50 mm (6 in) PVC cable model with a M/Euro-style quick disconnect, replace the suffix "Q" with "QP" in the model number. For example, K50BLGPQP. To order the m (6.5 ft) PVC cable model, omit the suffix "Q" in the model number. For example, K50BLGP. Models with a quick disconnect require a mating cordset. -color models use a -pin mating cable, see wiring diagram. Original Document 55509 Rev. L ugust 07 55509
Perimeter View Only Model Perimeter + Top View LED Color(s) Input Supply Voltage Connection K50BLY0Q K50BCLY0Q Yellow K50BLB0Q K50BCLB0Q Blue Wiring Diagrams DC Models Table : -Color Models (/NPN Selectable) _ -0V dc C + C NPN + -0V dc _ Key: = Brown = White = Blue = Black C = Indicator color = Not used Table : -Color Models C C -0V dc Key: = Brown = White = Blue = Black C = Indicator color C = Indicator color = Not used Table : -Color Models C C C 5 0 V dc C C C 5 NPN 0 V dc 5 Key: = Brown = White = Blue = Black 5 = Gray C = Indicator color C = Indicator color C = Indicator color = Not used vailable colors include: Green (G), Red (R), Yellow (Y), Blue (B) and White (W). Integral quick disconnect models are listed. To order the 50 mm (6 in) PVC cable model with a M/Euro-style quick disconnect, replace the suffix "Q" with "QP" in the model number. For example, K50BLGPQP. To order the m (6.5 ft) PVC cable model, omit the suffix "Q" in the model number. For example, K50BLGP. Models with a quick disconnect require a mating cordset. www.bannerengineering.com - Tel: +-76-5-6 P/N 55509 Rev. L
Wiring Diagrams C Models Quick-Disconnect Cabled Wiring Key: = Green (not used) = Red/Black = Red/White Wiring Key: = Black = White Specifications Supply Voltage and Current - V dc to 0 V dc models K50BL -color models: 0 m max. at V dc, 70 m max. at 0 V dc K50BCL -color models: 60 m max. at V dc, 80 m max. at 0 V dc K50BL -color models, per color: 75 m max. at V dc, 0 m max. at 0 V dc K50BCL -color models, per color: 95 m max. at V dc, 0 m max. at 0 V dc K50BL -color models, per color: 85m at V dc, 55 m at 0 V dc K50BCL -color models, per color: 0 m at V dc, 65 m at 0 V dc Supply Voltage and Current - 0 V ac models K50BL models: 85 V ac to 0 V ac or 75 V dc to 0 V dc at 6 m max. 50/60 Hz K50BCL models: 85 V ac to 0 V ac or 75 V dc to 0 V dc at 60 m max. 50/60 Hz Supply Voltage and Current - 0 V ac models K50BL models: 00 V ac to 50 V ac or 90 V dc to 0 V dc at 0 m max. 50 Hz to 60 Hz K50BCL models: 00 V ac to 50 V ac or 90 V dc to 0 V dc at 5 m max. 50 Hz to 60 Hz Supply Protection Circuitry V dc to 0 V dc models: Protected against reverse polarity and transient voltages 0 V ac and 0 V ac models: Protected against transient voltages Indicators LED colors are independently selected, depending on model For -color models: only one color can be on at a time. The higher color number overrides the lower color number. Environmental Rating Rated IEC IP67 and IP69K, per DIN 0050 NEM/UL Type, pplication Note Light emits 60 from housing sides in K50BL models and housing sides and tops in K50BCL models. Construction Base and covers: polycarbonate Connections Integral -pin M/Euro-style (dc models) QD, -pin Micro-style (ac models) QD, or m (6.5 ft) integral cable, depending on model Operating Conditions 0 C to +50 C ( 0 F to + F) 90% at +50 C maximum relative humidity (non-condensing) Vibration and Mechanical Shock ll models meet Mil. Std. 0F requirements method 0 (vibration: 0 to 60 Hz max., double amplitude 0.06 in, maximum acceleration 0G). lso meets IEC 97-5-; 0G ms duration, half sine wave. Indicator Power-up Response Time DC, and - color models ON: 0 ms; OFF: 7 ms DC -color models ON: 50 ms; OFF: 0 ms C models ON/OFF: 500 µs Required Overcurrent Protection WRNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class Power Supply. Supply wiring leads < WG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (WG) Required Overcurrent Protection (mps) 0 5.0.0.0 Certifications LIGHT DIRECTION LIGHT DIRECTION 6.0 8 0.8 0 0.5 dc models only P/N 55509 Rev. L www.bannerengineering.com - Tel: +-76-5-6
Dimensions 50 [.97 ] 9 [.] 9 [.9] [.] Internal Threads / - NPSM Max. torque.5 Nm (0 in.-lbs) M0 x.5 (mounting nut included) Max. torque.5 Nm (0 in.-lbs) M ccessories Cordsets -Pin Threaded M/Euro-Style Cordsets Model Length Style Dimensions (Female) MQDC-06.8 m (6 ft) Typ. MQDC-5.57 m (5 ft) MQDC-0 MQDC-50 MQDC-06R MQDC-5R MQDC-0R 9. m (0 ft) 5. m (50 ft).8 m (6 ft).57 m (5 ft) 9. m (0 ft) Straight Right-ngle Typ. [.6"] M x ø.5 0 Typ. [.8"] = Brown = White = Blue = Black MQDC-50R 5. m (50 ft) M x ø.5 [0.57"] -Pin Micro-Style Cordsets Model Length Style Dimensions (Female) MQDC-06 MQDC-5.8 m (6 ft).57 m (5 ft) Typ. Straight MQDC-0 9. m (0 ft) /-0 UNF-8 ø.5 MQDC-06R MQDC-5R.8 m (6 ft).57 m (5 ft) Right-ngle Typ 8 Typ = Green = Red/Black = Red/White MQDC-0R 9. m (0 ft) /-0 UNF-8 ø.5 www.bannerengineering.com - Tel: +-76-5-6 P/N 55509 Rev. L
Mounting Brackets ll measurements are listed in millimeters, unless noted otherwise. SMB0 Right-angle bracket with curved slot for versatile orientation Clearance for M6 (¼ in) hardware Mounting hole for 0 mm sensor -ga. stainless steel Hole center spacing: to B=0 Hole size: =ø 6., B= 7. x 6., C=ø 0.5 6 5 69 C B SMB0F Swivel bracket with tilt and pan movement for precise adjustment Mounting hole for 0 mm sensor -ga. 0 stainless steel Easy sensor mounting to extrude rail T-slot Metric and inch size bolt available 6. 8. B 68.9 Bolt thread: SMB0F, = /8-6 x in; SMB0FM0, = M0 -.5 x 50 Hole size: B= ø 0. SMB0MM -ga. stainless steel bracket with curved mounting slots for versatile orientation Clearance for M6 (¼ in) hardware Mounting hole for 0 mm sensor 57 70 B C 57 SMB0SC Swivel bracket with 0 mm mounting hole for sensor Black reinforced thermoplastic polyester Stainless steel mounting and swivel locking hardware included 58 9 67 B Hole center spacing: = 5, to B = 5. Hole size: =.6 x 7, B = ø 6., C = ø 0. Hole center spacing: =ø 50.8 Hole size: =ø 7.0, B=ø 0.0 Elevated Mount System Model Features Components S-M0E - Black cetal Streamlined black acetal stand-off pipe adapter/ cover Connects between 0 mm light base and ½ in. NPSM/DN5 pipe Mounting hardware included Polished 0 Stainless Steel Black nodized luminum Clear nodized luminum SOP-E-50SS 50 mm (6 in) long SOP-E-00SS 00 mm ( in) long SOP-E-50 50 mm (6 in) long SOP-E-00 00 mm ( in) long SOP-E-50C 50 mm (6 in) long SOP-E-00C 00 mm ( in) long Elevated-use stand-off pipe (½ in. NPSM/DN5) Polished 0 stainless steel, black anodized aluminum, or clear anodized aluminum surface ½ in. NPT thread at both ends Compatible with most industrial environments SOP-E-900SS 900 mm (6 in) long SOP-E-900 900 mm (6 in) long SOP-E-900C 900 mm (6 in) long S-EM0 - Black cetal Streamlined black acetal mounting base adapter/ cover Connects between ½ in. NPSM/DN5 pipe and 0 mm (-/6 in) drilled hole Mounting hardware included P/N 55509 Rev. L www.bannerengineering.com - Tel: +-76-5-6 5
Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WRRNTY IS ECLUSIVE ND IN LIEU OF LL OTHER WRRNTIES WHETHER EPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITTION, NY WRRNTY OF MERCHNTBILITY OR FITNESS FOR PRTICULR PURPOSE), ND WHETHER RISING UNDER COURSE OF PERFORMNCE, COURSE OF DELING OR TRDE USGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHLL BNNER ENGINEERING CORP. BE LIBLE TO BUYER OR NY OTHER PERSON OR ENTITY FOR NY ETR COSTS, EPENSES, LOSSES, LOSS OF PROFITS, OR NY INCIDENTL, CONSEQUENTIL OR SPECIL DMGES RESULTING FROM NY PRODUCT DEFECT OR FROM THE USE OR INBILITY TO USE THE PRODUCT, WHETHER RISING IN CONTRCT OR WRRNTY, STTUTE, TORT, STRICT LIBILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. ny misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. ny modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. ll specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. FCC Part 5 and CN ICES- (B)/NMB-(B) This device complies with part 5 of the FCC Rules and CN ICES- (B)/NMB-(B). Operation is subject to the following two conditions:. This device may not cause harmful interference, and. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 5 of the FCC Rules and CN ICES- (B)/NMB-(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the manufacturer. Banner Engineering Corp. ll rights reserved