EZ-LIGHT K50 Beacon. Datasheet. Models

Similar documents
Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

EZ-LIGHT K90FDL Daylight Visible

EZ-LIGHT K30L Series With Independent Push Button Contact

EZ-LIGHT S18L Color General-Purpose Indicators

TL70 Universal AC Voltage Modular Tower Light

EZ-STATUS WLS28-2 Multicolor LED Strip Light

WLS27 Multicolor LED Strip Light with EZ-STATUS

22 mm Flush Mount Multicolor RGB Indicator with Seven Color Flashing Input Control and up to Fourteen Color Options

EZ-LIGHT S18L General Purpose Indicators Controlled Access, Inc. orders this part as S18DLGRYPQ

WLC60 Heavy Duty LED Light - PWM Dimmable

Linear Array with Intensity Adjustment

LED Series Sealed Backlights

EZ-LIGHT K50 Modbus Series Multicolor Indicators

WLB92 Industrial LED Light Bar (AC Conduit)

Q3X Laser Contrast Sensor

L-GAGE LG Laser Gauging Sensors

TL mm Modular Tower Lights

Q3X Laser Contrast Sensor

Q3X Laser Contrast Sensor

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

DF-G3 Long Range Expert Dual Display Fiber Amplifier

WLS27. LED Strip Lights

MODEL/MODEL/MODEL #6324W-CAM

DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output

MINI-BEAM Expert Series Installation Guide Microprocessor-based TEACH mode photoelectric sensors¹

DF-G2 High Speed Expert Dual Display Fiber Amplifier with IO Link

45LM Series Modules. 45LM Series Description. Timing Logic Functions. LED Signal Strength Display Function. 45LM Series Modules Specifications

DF-G2 High Speed Expert Dual Display Small Object Counter. Instruction Manual

Model Number Structure

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

AWT150C/AWT150CS/ AWT151C CCD Camera

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

EZ-SCREEN LS. Safety Light Screen

Golf ball tracker. Instruction manual

OPERATING MANUAL. DMX Demultiplexer 3012B Mk2

Proximity Card Reader. User s Manual

Cylindrical Photoelectric Sensor CY-100 SERIES

Home Monitoring. Wired Color Camera. User Manual. For indoor/outdoor use. Do not use in wet locations.

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

L-GAGE LT3 Long-Range Time-of-Flight Laser Sensor

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Introduction. Package Contents. Installation Requirements

MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

D12 Expert Series TEACH-Mode Fiber Optic Sensors

User Instructions. 16 SCB Sync Station.

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

2nd Edition. Quick Start Guide. getawair.com

Indoor/Outdoor Analog Wired Camera Model P-520 USER'S MANUAL

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

Power Injector 1520 Series

HDMI Signal Booster - 4K

Owner s Manual. VGA + Audio to HDMI Adapter/Scaler. Model: P HDSC2

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

DisplayPort Signal Booster - 4K

T850 Day & Night Security Camera

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Instant 802.3af Gigabit Outdoor PoE Converter. Model: INS-3AF-O-G. Quick Start Guide

INSTRUCTION MANUAL SUPER LASER

Kramer Electronics, Ltd.

HDMI to Composite Converter. User s Guide

WINEGARD INSTALLATION MANUAL. Model GM Carryout Ladder Mount for mounting pipes with outer diameters between 1 to 1-1/8

USER MANUAL Full HD Widescreen LED Monitor L215ADS

Proximity Card Reader. User s Manual

2/4/8 Port High Speed HDMI Video Splitter with Audio

AITech ProA/V Media Extender 5GHz Digital

USER MANUAL Full HD Widescreen LED Monitor L215IPS

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk1

PSM-003. Micro Polarization Controller/Scrambler. User Guide

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

Owner s Manual. HDMI over Cat5/Cat6 Active Extender with Built-in 4K Upscaler. Models: B126-1A0-SC4K and B126-1A1-SC4K

OPERATING MANUAL. DMX / Constant Current Dekoder 3706A-H Mk1 RDM

Inductive sensor BI1.5-EG08K-Y1

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

Industrial Gigabit PoE+ Injector

ZvBox 150. HD video distribution over COAX Get Going Guide

Two-Hand-Control Modules

ServerCall Transmitter

SU17 Series Fiber Optic Sensors

User Manual MODEL: KKW700V. Non-Touch True Display LCD Monitor. Installation Guide. 7 True Display LCD Monitor (VGA Interface)

BRK Series. 600TVL INDOOR Color Camera. user, S manual. MODEL PRO-CMD600 1/4 CMOS with Night Vision AUTO IR CUT FILTER INDOOR 600 TVL CAMERA

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

HD Digital MPEG2 Encoder / QAM Modulator

Inductive sensor NI3-EG08K-Y1-H1341

Safety Light Curtains GuardShield

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Inductive sensor NI10-M18-Y1X-H1141

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

VGA to HDMI video converter with scaler

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

Transcription:

Datasheet Daylight-Visible, General-Purpose Indicators for Indoor or Outdoor Use To view or download the latest technical information about this product, including specifications, dimensions, accessories, and wiring, see www.bannerengineering.com. Intense levels of light output for areas with high ambient light - even outdoors Viewable around entire perimeter; some models also emit light from top - or -, or -color models available Rugged, sealed thermoplastic housing rated for IEC IP67 and IEC IP69K Bright, even light V dc to 0 V dc or 85 V ac to 0 V ac (75 V dc to 0 V dc) or 00 V ac to 50 V ac (90 V dc to 0 V dc) operation, depending on model V dc operation useful for applications on mobile vehicles Consult factory for models with strobing capability WRNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Perimeter View Only Model Perimeter + Top View LED Color(s) Input Supply Voltage Connection K50BLGPQ K50BCLGPQ Green K50BLRPQ K50BCLRPQ Red K50BLYPQ K50BCLYPQ Yellow K50BLBPQ K50BCLBPQ Blue V to 0 V dc -pin M/Euro-style integral quick disconnect K50BLWPQ K50BCLWPQ White K50BLGRPQ K50BCLGRPQ Green / Red K50BLGRYPQ K50BCLGRYPQ Green / Red / Yellow V to 0 V dc K50BLGRYNQ K50BCLGRYNQ Green / Red / Yellow NPN V to 0 V dc 5-pin M/Euro-style integral quick disconnect K50BLG0Q K50BCLG0Q Green K50BLR0Q K50BCLR0Q Red K50BLY0Q K50BCLY0Q Yellow K50BLB0Q K50BCLB0Q Blue K50BLW0Q K50BCLW0Q White C 85 V to 0 V ac -pin /Micro-style integral quick disconnect K50BLG0Q K50BCLG0Q Green K50BLR0Q K50BCLR0Q Red C 00 V to 50 V ac vailable colors include: Green (G), Red (R), Yellow (Y), Blue (B) and White (W). Integral quick disconnect models are listed. To order the 50 mm (6 in) PVC cable model with a M/Euro-style quick disconnect, replace the suffix "Q" with "QP" in the model number. For example, K50BLGPQP. To order the m (6.5 ft) PVC cable model, omit the suffix "Q" in the model number. For example, K50BLGP. Models with a quick disconnect require a mating cordset. -color models use a -pin mating cable, see wiring diagram. Original Document 55509 Rev. L ugust 07 55509

Perimeter View Only Model Perimeter + Top View LED Color(s) Input Supply Voltage Connection K50BLY0Q K50BCLY0Q Yellow K50BLB0Q K50BCLB0Q Blue Wiring Diagrams DC Models Table : -Color Models (/NPN Selectable) _ -0V dc C + C NPN + -0V dc _ Key: = Brown = White = Blue = Black C = Indicator color = Not used Table : -Color Models C C -0V dc Key: = Brown = White = Blue = Black C = Indicator color C = Indicator color = Not used Table : -Color Models C C C 5 0 V dc C C C 5 NPN 0 V dc 5 Key: = Brown = White = Blue = Black 5 = Gray C = Indicator color C = Indicator color C = Indicator color = Not used vailable colors include: Green (G), Red (R), Yellow (Y), Blue (B) and White (W). Integral quick disconnect models are listed. To order the 50 mm (6 in) PVC cable model with a M/Euro-style quick disconnect, replace the suffix "Q" with "QP" in the model number. For example, K50BLGPQP. To order the m (6.5 ft) PVC cable model, omit the suffix "Q" in the model number. For example, K50BLGP. Models with a quick disconnect require a mating cordset. www.bannerengineering.com - Tel: +-76-5-6 P/N 55509 Rev. L

Wiring Diagrams C Models Quick-Disconnect Cabled Wiring Key: = Green (not used) = Red/Black = Red/White Wiring Key: = Black = White Specifications Supply Voltage and Current - V dc to 0 V dc models K50BL -color models: 0 m max. at V dc, 70 m max. at 0 V dc K50BCL -color models: 60 m max. at V dc, 80 m max. at 0 V dc K50BL -color models, per color: 75 m max. at V dc, 0 m max. at 0 V dc K50BCL -color models, per color: 95 m max. at V dc, 0 m max. at 0 V dc K50BL -color models, per color: 85m at V dc, 55 m at 0 V dc K50BCL -color models, per color: 0 m at V dc, 65 m at 0 V dc Supply Voltage and Current - 0 V ac models K50BL models: 85 V ac to 0 V ac or 75 V dc to 0 V dc at 6 m max. 50/60 Hz K50BCL models: 85 V ac to 0 V ac or 75 V dc to 0 V dc at 60 m max. 50/60 Hz Supply Voltage and Current - 0 V ac models K50BL models: 00 V ac to 50 V ac or 90 V dc to 0 V dc at 0 m max. 50 Hz to 60 Hz K50BCL models: 00 V ac to 50 V ac or 90 V dc to 0 V dc at 5 m max. 50 Hz to 60 Hz Supply Protection Circuitry V dc to 0 V dc models: Protected against reverse polarity and transient voltages 0 V ac and 0 V ac models: Protected against transient voltages Indicators LED colors are independently selected, depending on model For -color models: only one color can be on at a time. The higher color number overrides the lower color number. Environmental Rating Rated IEC IP67 and IP69K, per DIN 0050 NEM/UL Type, pplication Note Light emits 60 from housing sides in K50BL models and housing sides and tops in K50BCL models. Construction Base and covers: polycarbonate Connections Integral -pin M/Euro-style (dc models) QD, -pin Micro-style (ac models) QD, or m (6.5 ft) integral cable, depending on model Operating Conditions 0 C to +50 C ( 0 F to + F) 90% at +50 C maximum relative humidity (non-condensing) Vibration and Mechanical Shock ll models meet Mil. Std. 0F requirements method 0 (vibration: 0 to 60 Hz max., double amplitude 0.06 in, maximum acceleration 0G). lso meets IEC 97-5-; 0G ms duration, half sine wave. Indicator Power-up Response Time DC, and - color models ON: 0 ms; OFF: 7 ms DC -color models ON: 50 ms; OFF: 0 ms C models ON/OFF: 500 µs Required Overcurrent Protection WRNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class Power Supply. Supply wiring leads < WG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (WG) Required Overcurrent Protection (mps) 0 5.0.0.0 Certifications LIGHT DIRECTION LIGHT DIRECTION 6.0 8 0.8 0 0.5 dc models only P/N 55509 Rev. L www.bannerengineering.com - Tel: +-76-5-6

Dimensions 50 [.97 ] 9 [.] 9 [.9] [.] Internal Threads / - NPSM Max. torque.5 Nm (0 in.-lbs) M0 x.5 (mounting nut included) Max. torque.5 Nm (0 in.-lbs) M ccessories Cordsets -Pin Threaded M/Euro-Style Cordsets Model Length Style Dimensions (Female) MQDC-06.8 m (6 ft) Typ. MQDC-5.57 m (5 ft) MQDC-0 MQDC-50 MQDC-06R MQDC-5R MQDC-0R 9. m (0 ft) 5. m (50 ft).8 m (6 ft).57 m (5 ft) 9. m (0 ft) Straight Right-ngle Typ. [.6"] M x ø.5 0 Typ. [.8"] = Brown = White = Blue = Black MQDC-50R 5. m (50 ft) M x ø.5 [0.57"] -Pin Micro-Style Cordsets Model Length Style Dimensions (Female) MQDC-06 MQDC-5.8 m (6 ft).57 m (5 ft) Typ. Straight MQDC-0 9. m (0 ft) /-0 UNF-8 ø.5 MQDC-06R MQDC-5R.8 m (6 ft).57 m (5 ft) Right-ngle Typ 8 Typ = Green = Red/Black = Red/White MQDC-0R 9. m (0 ft) /-0 UNF-8 ø.5 www.bannerengineering.com - Tel: +-76-5-6 P/N 55509 Rev. L

Mounting Brackets ll measurements are listed in millimeters, unless noted otherwise. SMB0 Right-angle bracket with curved slot for versatile orientation Clearance for M6 (¼ in) hardware Mounting hole for 0 mm sensor -ga. stainless steel Hole center spacing: to B=0 Hole size: =ø 6., B= 7. x 6., C=ø 0.5 6 5 69 C B SMB0F Swivel bracket with tilt and pan movement for precise adjustment Mounting hole for 0 mm sensor -ga. 0 stainless steel Easy sensor mounting to extrude rail T-slot Metric and inch size bolt available 6. 8. B 68.9 Bolt thread: SMB0F, = /8-6 x in; SMB0FM0, = M0 -.5 x 50 Hole size: B= ø 0. SMB0MM -ga. stainless steel bracket with curved mounting slots for versatile orientation Clearance for M6 (¼ in) hardware Mounting hole for 0 mm sensor 57 70 B C 57 SMB0SC Swivel bracket with 0 mm mounting hole for sensor Black reinforced thermoplastic polyester Stainless steel mounting and swivel locking hardware included 58 9 67 B Hole center spacing: = 5, to B = 5. Hole size: =.6 x 7, B = ø 6., C = ø 0. Hole center spacing: =ø 50.8 Hole size: =ø 7.0, B=ø 0.0 Elevated Mount System Model Features Components S-M0E - Black cetal Streamlined black acetal stand-off pipe adapter/ cover Connects between 0 mm light base and ½ in. NPSM/DN5 pipe Mounting hardware included Polished 0 Stainless Steel Black nodized luminum Clear nodized luminum SOP-E-50SS 50 mm (6 in) long SOP-E-00SS 00 mm ( in) long SOP-E-50 50 mm (6 in) long SOP-E-00 00 mm ( in) long SOP-E-50C 50 mm (6 in) long SOP-E-00C 00 mm ( in) long Elevated-use stand-off pipe (½ in. NPSM/DN5) Polished 0 stainless steel, black anodized aluminum, or clear anodized aluminum surface ½ in. NPT thread at both ends Compatible with most industrial environments SOP-E-900SS 900 mm (6 in) long SOP-E-900 900 mm (6 in) long SOP-E-900C 900 mm (6 in) long S-EM0 - Black cetal Streamlined black acetal mounting base adapter/ cover Connects between ½ in. NPSM/DN5 pipe and 0 mm (-/6 in) drilled hole Mounting hardware included P/N 55509 Rev. L www.bannerengineering.com - Tel: +-76-5-6 5

Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WRRNTY IS ECLUSIVE ND IN LIEU OF LL OTHER WRRNTIES WHETHER EPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITTION, NY WRRNTY OF MERCHNTBILITY OR FITNESS FOR PRTICULR PURPOSE), ND WHETHER RISING UNDER COURSE OF PERFORMNCE, COURSE OF DELING OR TRDE USGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHLL BNNER ENGINEERING CORP. BE LIBLE TO BUYER OR NY OTHER PERSON OR ENTITY FOR NY ETR COSTS, EPENSES, LOSSES, LOSS OF PROFITS, OR NY INCIDENTL, CONSEQUENTIL OR SPECIL DMGES RESULTING FROM NY PRODUCT DEFECT OR FROM THE USE OR INBILITY TO USE THE PRODUCT, WHETHER RISING IN CONTRCT OR WRRNTY, STTUTE, TORT, STRICT LIBILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. ny misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. ny modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. ll specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. FCC Part 5 and CN ICES- (B)/NMB-(B) This device complies with part 5 of the FCC Rules and CN ICES- (B)/NMB-(B). Operation is subject to the following two conditions:. This device may not cause harmful interference, and. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 5 of the FCC Rules and CN ICES- (B)/NMB-(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the manufacturer. Banner Engineering Corp. ll rights reserved