Shouson Theatre Venue Specifications (updated Jan 2017)

Similar documents
Louis Koo Cinema Venue Specifications (updated 2018)

Theatre Technical Specifications

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

RPAC REDLANDS PERFORMING ARTS CENTRE

Technical Data Sheet

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

2017 TECHNICAL SPECIFICATIONS

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Theatre Technical Specification

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Main House Technical Specification

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

SHUBERT THEATER 247 College Street, New Haven, CT

Arcadia Performing Arts Center Technical Specifications and Information

DEREHAM MEMORIAL HALL

JERWOOD VANBRUGH THEATRE

Technical Specifications

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Technical Information

Hopgood Theatre NOARLUNGA CENTRE

Performing Arts Theatre

Matt Dann Cultural Centre

Technical Specification

Technical Specifications. Taylor Little Theater

CENTRE FOR PERFORMING ARTS

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Sandusky State Theatre Technical Specifications

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

HIRE AND TECHNICAL INFORMATION

Technical Specification Ardhowen Theatre

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

TECHNICAL SPECIFICATIONS

Technical Specification for the Alley Theatre, Strabane

Technical Specifications

Concert Hall Technical Specifications

Technical specifications Main theatre. Sound

Downtown Arts Center Tech Packet. General Information

The Haymarket Basingstoke Technical Specifications

Concert Hall Technical Specifications

Marjorie S. Deane Little Theater

Main House Technical Specifications

New Theatre Royal Lincoln Technical Information

Technical Specifications

The Georgian Theatre Royal Technical Information For Visiting Companies

SAINT ANSELM COLLEGE DANA CENTER

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

Jane Mallet Theatre Technical Specifications

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

INFORMATION FOR VISITING COMPANIES

ISLAND HALL TECHNICAL INFORMATION

Technical Specifications

Technical Specification Pavilion Dance

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

CHELSEA THEATRE. Technical Specifications

Technical requirements & conditions for hirers

Stage. Get In & Parking

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Specifications

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Lighthouse Theatre Technical Specification

Technical Specifications Nov 2016

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

Technical Specification

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Technical Services and Specification

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Latrobe Performing Arts Centre

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

There are 10 dressing rooms in Theatre Kerkrade.

Theatre Technical Specifications

THE STREET THEATRE. Technical Specifications

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Hopgood Theatre NOARLUNGA CENTRE

Technical Specification

Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Technical Specification (Studio Theatre)

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Patriots Theater at the War Memorial Technical Data

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Main Stage Technical Specs - Hall #2

Scale of Hire Charges

Technical Specification (Studio Theatre)

Technical Specifications Updated 01/10/2017. Stage

TECHNICAL SPECIFICATION

T1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422

Technical Specification. Updated: April 2016

TECHNICAL INFORMATION

Technical Pack. Attenborough Arts Centre

Transcription:

Shouson Theatre Venue Specifications (updated Jan 2017) Shouson Theatre is the largest venue in HKAC with capacity 439 seats. The proscenium theatre offers superb views from every seat, which audiences can enjoy an intimate theatrical experience. It is primarily used for concert, drama and dance performances, but also ideal for film screenings and seminars. DROP OFF AREA Drop off area 1 Drop off area 2 Nearby Public Carpark Hong Kong Arts Centre Fenwick Street entrance The Harbourview Hotel entrance (No. 4 Harbour Road) Shui On Centre (No. 6-8 Harbour Road), Wanchai Towers (No. 12 Harbour Road) HKCEC Convention Plaza (No. 1 Harbour Road)

LOADING Loading dock G/F entrance in Fenwick Street (opposite to HKAPA) Height restriction of loading dock 3m H Scenery dock Stage Left, size: 3.6W x 3.9D x 2.8H m Equipped with hoisting cargo cage for delivering goods from G/F loading dock to stage Maximum loading of Cargo Cage: 800Kg Shutter size: Stage level 2.8H x 3.7W m Ground level 2.1H x 2.6W m AUDITORIUM Continental style in Stall and Circle, entrances to auditorium at G/F, 1/F & 3/F Full Seating Capacity 439 (Stall 260, Circle 179) Seating for Film show 425 (Stall 246, Circle 179) Wheelchair space 1 at Stall seat G1 STAGE Proscenium Structural opening 8.08W x 5.49H m Adjustable Width 8.08m to 11.5.m Stage Floor Flat black surface hardboard (No painting or drilling) Harlequin Standfast black mat for dance flooring (Please allow time for setup during the booking time) Maximum Loading 726Kg /m 2 (150 lbs. /sq. ft.) Trap door on stage Detail refers to Technical Plan III Height from Trap door to Ground level 2.5m Stage Width Main stage width 8.08m Stage Depth Proscenium to back-wall 11.45m Proscenium to Cyclorama (line 28) 6.45m Proscenium to stage edge 0.55m Proscenium to forestage 2.1m Stage Height Clear under grid 14.8m Clear under bar 13.6m (Except Line 5, 16, & 24, which is 8m) Above Auditorium 1m above auditorium floor

Forestage Forestage area can be lowered to auditorium level In the shape of trapezoid, size: 7.8W x 1.59D m Stage width can be extended to 10.5m by adding 2 removable platforms Orchestra pit Forestage can be lowered beneath the auditorium level as orchestra pit Size: 7.8W x 3D x 1.7H m Accommodate up to 15 musicians Rear Stage Rear of Cyclorama (Crossover from stage left to right) 16.25W x 2.5D m Side Stage / Storage space Limited wing spaces on both sides (when main stage width is 8.08m) Stage Left 2W x 4.8D x 2.45H m Stage Right 1.8W x 4.8D x 2.4H m Stage Drapery Red Velour House Curtain (9W x 6.5H m) (Electrically opened or raised manually) Black border (10W x 2.5H m) 3 flats Side masking flat (1.2W x 5.5H m) 10 flats Side masking leg (2.5W x 5.5H m) 2 pairs Black gauze (11W x 7H m) White gauze (11W x 7H m) Curved black backdrop (12W x 6H m) Curved white cyclorama (12W x 6H m) Flying System 24 Manual rope-operated double purchase counterweight lines Loading capacity 250Kg each Bar length Variable from 8.5m to 11m Bar height 13.6m (Except Line 5, 16, & 24, which is 8m) Bar diameter 48.5mm Bar distance 0.2m (in general) Header Line 1 House curtain Line 2 Film screen Line 4 Resident spotbar Line 5, 16 & 24 Black backdrop Line 28 White cyclorama Line 29

Motorized Winch Bar (Located at rear of cyclorama) 2 Bar length 6.8m (Up stage) 7.3m (Down stage) Bar height 5.7m Loading capacity 100Kg each Other equipment Cougar XLT2400 hydraulic lift Max. 5.9m H (operated by competent person and prior approved by Technical Department only) Yamaha C2 baby grand piano 1 Yamaha upright piano 1 Black music stand # 28 Music stand light # 28 Podium 1 Table (1.8m L x 0.6m D x 0.7m H) # 4 Chair (Black with silver edge) # 40 Red Velour table cloths # 4 LIGHTING Control Board Located in lighting control room at rear of auditorium ETC Expression III, with full back up control facilities, controllable of 140 channels Control patching arrangement at switchboard Dimmers 136 x 2kW production lighting dimmers and 4 x 5kW dimmers Circuits 140 circuits Power supply 13A wall-mounted socket outlets to UK standard are provided on the stage wall Additional power * One 60A x 3 phase socket, located at stage left loading bay The hirer may bring-in electrical equipment and connect to the additional power source, and the required electrical works must be conducted by the local registered electrical workers. Lighting positions 2 light bridges over auditorium 3 spot bars at Line 5, 16 & 24 Light track at circle front Houselight Dimmer controlled. Take-control available in lighting control room Cyclorama light Altman Spectra Series LED Cyclorama 7 Strand Iris-4 5

Lighting equipment Profiles Altman Ellipsoidals PHX Zoom 750W 30/55 24 Altman Ellipsoidals PHX Zoom 750W 15/35 34 ETC Source Four 750W 25/50 4 ETC Source Four 750W 15/30 14 Fresnel CCT Starlette 1kW 20 Robert Juliat Lutin 306LF 1kW 20 Robert Juliat 329HF 2kW 8 Follow Spots Robert Juliat Mannon 1.2kW MSD 2 Others Par-can 1kW 12 Other equipment Light tower (ETC Source Four jr Zoom 575W 25/50 ) 6 & Effect accessories Light ladder 2 on each side Strobe light 1 UV set 2 Smoke generator (Smoke Factory) 1 Dry-ice generator * 2 Animation disc 2 Gobo rotator& holder (fit for M & B size) 2 Full range of LEE filters SOUND Control Room Located at rear of auditorium in stall Console Yamaha IM8-40 channels, 8 group output Signal Processor Yamaha Q2031 equalizer 2 Yamaha SPX-990 effect processor 1 House Speaker System Clair Brothers Kit 12 2 Clair Brothers CS18-M subwoofer 2 Fixed House PA System Clair Brothers FF2-H for stall & circle 4 Mobile Speakers Mackie C200 Two-way loudspeaker 2 Mackie C300z Two-way loudspeaker 2 Playback equipment Tascam CD-160 CD player 1 Tascam MD 350 Mini Disc player 2 Microphones Shure SM 57 6 Shure SM 58 6 Crown PCC-160 3

Wirelesss Microphones * Communication system Shure SLX4 Series Handheld (SM 58 Head) 6 Belt Pack 5 Maximum 6 wireless mics in use Prompt corner at stage left, with stage manager's desk, talkback system, cue light system, cast call paging system to dressing rooms and infrared CCTV monitor viewing stage Wired intercom system available at all control points PROJECTION Screen White perforated screen with adjustable masking Sound (for 35mm Screening) Dolby A/SR with surround sound system Video/Computer Projection SANYO PLC-XF70 (9000 lumens) video projector * Computer Resolution: up to 1024 x 768 Hirer should bring their own playback device, e.g.: DVD player, Blu-ray Disc Player or Computer Support Video Interface: Component Video, VGA, HDMI, DVI 35mm Projection Century projector 3KW xenon lamphouse x 2 Cinemascope: approx.7.9w x 3H m Standard: approx. 4.7W x 3.6H m DRESSING ROOM & OTHER FACILITIES Dressing room 6 dressing rooms (Room A-E & H) at G/F level Room A-C & H for 3-4 person and Room D & E for 6-8 person, Both sides of stage have staircase access to dressing room Show relay and cast paging in the area of backstage and dressing room All rooms equipped with access codes locks and lockers Lockers in the dressing rooms are fitted with a staple and hasp In order to lock a locker, hirer should bring their own padlocks Quick-change room Temporary quick-change rooms can be set at stage (must approved by Theatre Technical Department) Wardrobe facilities Washing machine and Dryer, Iron and Iron boards, steamer and sewing machine Artist s facilities 3 washrooms with shower facilities, refrigerator and water dispenser, tables and chairs

FRONT OF HOUSE FACILITIES Casual Bar at 1/F which accommodate for cocktail reception (max. 30 pax) Show relay at auditorium entrances in 1/F and 3/F for latecomers Tables (1.8L x 0.6D x 0.7H m) with red table cloths # Chairs # Movable display panels # Stanchions # HKAC reserves the right to change the venue facilities without prior notice. * Optional equipment for which an additional hiring charge will be applied. # These items are shared amongst several venues, the availability is subject to the requirements of the other venues