User Guide. Westermo Teleindustri AB 2005 MCW Industrial Ethernet Media Converter.

Similar documents
User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

Fibre optic router for TP/FT-10 LRW-112PP

LONWORKS Fibre Optic Converter

Fibre Optic Modem ODW-622

Fibre Optic Modem ODW-611

LONWORKS Fibre Optic Router

ODW-621. RS-232 Point-to-point applications

ODW-612 Fibre Optic Modem

LRW-102. Fibre Optic industrial converter/repeater for LonWorks TP/FT-10 point-to-point, line and redundant ring. User Guide

Rack mounted telephone- and leased line modem for industrial applications

ODW-610-F2. Industrial Converter PROFIBUS DP to Fibre Optic Link Repeater, line and redundant ring. Fibre Optic Modem. User Guide

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

Owner s Manual. 10/100 Media Converters. Models: N SC-MM (850nm), N SC-15 (1310nm) 10/100/1000 Media Converters

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

IEC G-port Gigabit smart rackmount Ethernet switches STAT PWR1 PWR2 FAULT FDX/HDX MODE. Warranty

E3/DS3 Fibre Extender

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

I/A Series Hardware Fiber Optic LAN Converter

I/A Series Hardware Fieldbus Communications Module, FCM10Ef

SY-HDBT-100 Extender Set

Perle Fast Ethernet Media Converters

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

FOM-9010, FOM-9011 and FOM-9012

Installation. Step 1 Carefully unpack the package contents.

Perle Fast Ethernet Media Converters

HD-One DX/DX500 HDMI Extender

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

EDS-210A Series. 8+2G/9+1G-port Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

Industrial Wi-Fi Access Point and Client - DM500

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

SY-HDBT-SLIM-100S Extender Set

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions.

02/11/2015

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Ethernet Media Converters

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

EDS-G205-1GTXSFP/G308 Series

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

4 Channel Video and IP Over Fiber Extender Kit with RS485 Data. User Manual L-4VID-1IP-FE-TX-RX

USER S GUIDE NEC-GXE-xx Base-X Fiber ExpressCard

Marshall Electronics. Broadcast A/V Division VAC-HT12-KIT. 4K HDBaseT Extender Kit. User Manual

User s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

SH2RE16A4. Output relay module. Benefits. Description

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Ordering Information. Industrial Ethernet Solutions

User Manual POE. Twisted Pair POE Extender

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

SY-MS121 SY-MS121-AP

IES-3162GC. >> Industrial 18-port Managed Ethernet Switch with 16x10/100Base-T(X) Ports and 2xGigabit combo ports. Industrial Ethernet Switch

Operating instructions

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Assembly. Front view. LEDs. Parametrization interface. Power Bus

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

MAP110 AC-DC Series Data Sheet

RLT 1550 d10. DWDM High Power, Ultra Wide Band CATV & SAT MHz Laser Optical Transmitter, with pre-correction, LAN remote control and alarms

NI PXI/PXIe-2543 Specifications

User Manual HD-HAUD-SP-RX. 100m HDBaseT HDMI Receiver

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Digital Input Modules for Compact FieldPoint

USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode

Single mode 9/125µm, duplex

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

Process Transmitter RMA 422

VIPA Accessories. ProfiHub B BE00 Manual

Datasheet - SRB-E-201ST

Job Aid Server and CSS Separation Avaya S8700 Media Server

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

User Manual CS-HDBTLPOER m HDBaseT Extender with Bi-directional PoE. Version: V1.0.0

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Two (2) fibers Detachable DisplayPort Extender

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

Transcription:

User Guide MCW-211 S E R I E S 6645-2202 Westermo Teleindustri AB 2005 Industrial Ethernet Media Converter www.westermo.com

Safety! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. This unit uses convection cooling.to avoid obstructing the airflow around the unit, follow the spacing recommendations (see Cooling section). Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit.there are no user serviceable parts inside. Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not paint the unit. Paint can clog the unit and prevent proper operation. Do not expose the unit to any kind of liquids (rain, beverages, etc).the unit is not waterproof. Keep the unit within the specified humidity levels. Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions. 2 6645-2202

Functional description Introduction The MCW-211 is an Industrial Ethernet FX/TX Media Converter. The MCW-211 convert data between Ethernet 10/100Base-TX and 100Base-FX. The unit is easy to use and install caused by auto-negotiation of speed and duplex, autocrossover and auto-polarity.the media converter is transparent for large frames (VLAN or QoS). It is also possible to set speed, duplex and flow control via DIP-switches. The FX side supports Far-End-Fault indication. A link fault from either side is forwarded to the other side, Link Fault Forwarding. MCW-211 has a wide DC power input range with polarity protection and redundant power from dual sources.with extended temperature range supported as standard the MCW-211 is designed to be used the harshest environments. Location of Interface ports, LED s and DIP-switches DIP-switches Accessible under lid LED indicators Network RJ-45 connection Network Fibre connection Power connection 6645-2202 3

Declaration of Conformity Westermo Teleindustri AB Declaration of conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model Art no Installation manual DIN-rail MCW-211-MM-SC2 MCW-211-MM-ST2 MCW-211-SM-SC15 MCW-211-SM-LC15 MCW-211-SM-LC40 MCW-211-MM-LC2 3645-0001 3645-0010 3645-0020 3645-0030 3645-0040 3645-0050 6645-2201 is in conformity with the following EC directive(s). No Short name 89/336/EEG Electromagnetic Compatibility (EMC) References of standards applied for this EC declaration of conformity. No Title Issue EN 61000-6-2 Immunity for industrial environments 2 (2001) EN 61000-6-4 Emission standard for industrial environments 1 (2001) The last two digits of the year in which the CE marking was affixed: 05 Hans Levin Technical Manager 9th May 2005 Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 4 6645-2202

Agency approvals and standards compliance Type Approved Approval / Compliance Agency/ W-mo EMC W-mo EN 61000-6-2, Immunity industrial environments W-mo EN 61000-6-4, Emission industrial environments Safety W-mo EN 60950, IT equipment Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test Description Test levels ESD EN 61000-4-2 Enclosure contact ± 4 kv Enclosure air ± 8 kv RF field AM IEC 61000-4-3 Enclosure 10 V/m 80% AM (1 khz), 80 1 000 MHz modulated Fast transient EN 61000-4-4 Signal ports ± 1 kv Power ports ± 2 kv Surge EN 61000-4-5 Signal ports balanced ± 2 kv line to earth, ± 1 kv line to line Power ports ± 2 kv line to earth, ± 2 kv line to line RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 khz), 0.15 80 MHz Power ports 10 V 80% AM (1 khz), 0.15 80 MHz Voltage dips EN 61000-4-29 DC power ports 10 & 100 ms, interruption and interruption 10 ms, 30% reduction 10 ms, 60% reduction +20% above & 20% below rated voltage Radiated emission EN 55022 Enclosure Class B Conducted emission EN 55022 DC power ports Class B Dielectric strength EN 60950 Signal port to other 1.5 kvrms 50 Hz 1 min isolated ports Power port to other 2 kvrms 50 Hz 1 min isolated ports Environmental Temperature Operating 25 to +70ºC Storage & Transport 40 to +70ºC Humidity Operating 5 to 95% relative humidity Storage & Transport 5 to 95% relative humidity Altitude Operating 2 000 m / 70 kpa Service life Operating 10 year Vibration IEC 60068-2-6 Operating 7.5 mm, 5 8 Hz 2 g, 8 500 Hz Shock IEC 60068-2-27 Operating 15 g, 11 ms Packaging Enclosure UL 94 PC / ABS Flammability class V-1 Dimension 35 x 121 x 119 mm W x H x D Weight 0.25 kg Degree of protection IEC 529 Enclosure IP 21 Cooling Convection Mounting Horizontal on 35 mm DIN-rail 6645-2202 5

Interface specifications Power Rated voltage 12 to 48 VDC Operating voltage 10 to 60 VDC Rated current 200 ma @ 12 VDC 100 ma @ 24 VDC 50 ma @ 48 VDC Rated frequency DC Inrush current I 2 t 0.03A 2 s @ 12 VDC Startup current* 0.75A peak Polarity Reverse polarity protected Redundant power input Yes Isolation to Ethernet TX Ethernet FX Connection Detachable screw terminal Connector size 0.2 2.5 mm 2 (AWG 24 12) Shielded cable Not required * External supply current capability for proper startup Position Direction** Description Product marking 1 Common COM 2 In + Voltage A +VA 3 In + Voltage B +VB ** Direction relative this unit Ethernet TX Electrical specification Data rate Duplex Transmission range Isolation to Connection IEEE std 802.3. 2000 Edition 10 Mbit/s or 100 Mbit/s, manual or auto Full or half, manual or auto 100 m Power RJ-45 Position Direction* Description Product marking 1 In/Out TD+ 2 In/Out TD- 3 In/Out RD+ 4 5 6 In/Out RD- 7 8 Shield HF-connected * Direction relative this unit 6 6645-2202

Ethernet FX Optical specification Data rate Duplex Connection IEEE std 802.3. 2000 Edition 100 Mbit/s Full or half SC, ST or LC Position Direction* Description Product marking Rx In Receive port Rx Tx Out Transmit port Tx * Direction relative this unit Fibre optic power budget Model MCW-211-MM MCW-211-SM MCW-211-SM MCW-211-SM xx2 SC15 LC15 LC40 Transmitted 1310 nm 1310 nm 1310 nm 1310 nm wavelength Min. output power, 19 dbm 15 dbm 15 dbm 5 dbm transmitter Max. output power, 12 dbm 8 dbm 8 dbm 0 dbm transmitter Input sensitivity, 31 dbm 34 dbm 31 dbm 34 dbm receiver Min. power budget 12 dbm 19 dbm 16 dbm 29 dbm Max. power budget 19 dbm 26 dbm 23 dbm 34 dbm Recommended Multimode Singlemode Singlemode Singlemode fibre cable and 50/125, 62.5/125 9/125, 10/125 9/125, 10/125 9/125, 10/125 core / cladding diameter Fibre type Normal attenuation Normal attenuation @ 1310 nm multimode @ 1310 nm singlemode 50/125 3.0 dbm/km 62,5/125 3.5 dbm/km 9/125 0.5 dbm/km 10/125 0.5 dbm/km Attenuation in connectors / splices Type Connector Fusion splice Mechanical splice Normal attenuation 0.2 0.4 dbm 0.1 dbm 0.2 dbm 6645-2202 7

LED indicators LED indicators are available on the front panel and on the RJ-45 TX connector. LED Status Description PWR Internal power, initialising OK Slow flash Initialisation progressing Fast flash Initialisation error LINK TX OFF No Ethernet link TX Good Ethernet link TX Flash Ethernet data is transmitted or received on TX interface LINK FX OFF No Ethernet link FX Good Ethernet link FX Flash Ethernet data is transmitted or received on FX interface FX DPX OFF Half dupex FX interface Full duplex FX interface LFF OFF Link fault forward is not active Link fault forward is active and has shutdown an interface LED Status Description SPD OFF 10 Mbit/s TX interface 100 Mbit/s TX interface DPX OFF Half duplex TX interface Full duplex TX interface SPD TX DPX 8 6645-2202

! Installation Mounting / Removal Before mounting or removing the unit: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. Mounting This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate. This unit uses convection cooling.to avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit. Snap on mounting, see figure 10 mm * (0.4 inches) 25 mm CLICK! * Spacing (left/right) recommended for full operating temperature range 25 mm Removal Press down the black support at the back of the unit, see figure. 6645-2202 9

Configuration DIP switches are accessible under the lid on top of the unit. DIP switches are used to configure the unit.! DIP-switch settings Before DIP-switch settings: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). NOTE DIP-switch alterations are only effective after a power on. To be observe when the DIP-switches will be configured Speed and duplex setting only valid when auto-negotiation is disabled. If auto-negotiation and auto MDI/MDI-X disabled the TX ports supports MDI-X configuration. 10 6645-2202

TX Port settings Flow control setting Auto-negotiation and auto MDI / MDI-X disabled TX port Flow control disabled Auto-negotiation and auto MDI / MDI-X enabled TX port Flow control enabled 10 Mbit/s speed selected TX port Link fault forward settings 100 Mbit/s speed selected TX port TX FX Link fault forward disabled Half duplex selected TX port TX FX Link fault forward enabled Full duplex selected TX port FX TX Link fault forward disabled FX Port settings FX TX Link fault forward enabled Half duplex selected FX port Factory settings Full duplex selected FX port 6645-2202 11

Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Phone +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.se Westermo Web site: www.westermo.com Westermo OnTime AS Gladsvei 20 0489 Oslo, Norway Phone +47 220 903 03 Fax +47 220 903 10 E-mail: contact@ontimenet.com Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate, Southampton SO31 7GA Phone: +44(0)1489 580 585 Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk Subsidiaries Westermo Data Communications GmbH Goethestraße 67, 68753 Waghäusel Tel.: +49(0)7254-95400-0 Fax.:+49(0)7254-95400-9 E-Mail: info@westermo.de Westermo Data Communications S.A.R.L. 9 Chemin de Chilly 91160 CHAMPLAN Tél : +33 1 69 10 21 00 Fax : +33 1 69 10 21 01 E-mail : infos@westermo.fr Westermo Teleindustri AB have distributors in several countries, contact us for further information. REV.A 6645-2202 05.10 Mälartryck AB, Eskilstuna, Sweden