User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

Similar documents
User Guide. Westermo Teleindustri AB 2005 MCW Industrial Ethernet Media Converter.

LONWORKS Fibre Optic Converter

Fibre Optic Modem ODW-622

Fibre optic router for TP/FT-10 LRW-112PP

Fibre Optic Modem ODW-611

LONWORKS Fibre Optic Router

ODW-621. RS-232 Point-to-point applications

LRW-102. Fibre Optic industrial converter/repeater for LonWorks TP/FT-10 point-to-point, line and redundant ring. User Guide

ODW-610-F2. Industrial Converter PROFIBUS DP to Fibre Optic Link Repeater, line and redundant ring. Fibre Optic Modem. User Guide

ODW-612 Fibre Optic Modem

Rack mounted telephone- and leased line modem for industrial applications

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

Owner s Manual. 10/100 Media Converters. Models: N SC-MM (850nm), N SC-15 (1310nm) 10/100/1000 Media Converters

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

HD-One DX/DX500 HDMI Extender

Installation. Step 1 Carefully unpack the package contents.

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

Perle Fast Ethernet Media Converters

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

I/A Series Hardware Fiber Optic LAN Converter

User Guide. HDMI Fiber Optic Extender. DVI-7350a

OptEnet OC48 Regenerator Module User Manual

E3/DS3 Fibre Extender

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

IEC G-port Gigabit smart rackmount Ethernet switches STAT PWR1 PWR2 FAULT FDX/HDX MODE. Warranty

Perle Fast Ethernet Media Converters

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Process transmitter RMA422

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions.

EDS-G205-1GTXSFP/G308 Series

MAP110 AC-DC Series Data Sheet

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

SY-HDBT-100 Extender Set

ASP-FIBRS1 User Manual

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

4 Channel Video and IP Over Fiber Extender Kit with RS485 Data. User Manual L-4VID-1IP-FE-TX-RX

Ordering Information. Industrial Ethernet Solutions

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

NI PXI/PXIe-2543 Specifications

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

USER MANUAL DUX-TX DUX-RX HDMI EXTENDER

I/A Series Hardware Fieldbus Communications Module, FCM10Ef

HD/SD-SDI Over Fiber Transmitter and Receiver Extender Kit. User Manual L-1SDI-SFE-TX/RX

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

DisplayPort Extender over 2 LC Fibers

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

USER S GUIDE NEC-GXE-xx Base-X Fiber ExpressCard

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

User Manual HD-HAUD-SP-RX. 100m HDBaseT HDMI Receiver

Operating instructions

02/11/2015

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

Two (2) fibers Detachable DisplayPort Extender

FOM-9010, FOM-9011 and FOM-9012

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Two (2) fibers Detachable DisplayPort 1.2 Extender. User s Manual for the DPFX-200-TR. Manual Contents

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

FiberLink 7142 Series

Kramer Electronics, Ltd. USER MANUAL. Models: 622T, Dual Link DVI Optical Transmitter 622R, Dual Link DVI Optical Receiver

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

Single mode 9/125µm, duplex

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

Agilent 87405C 100 MHz to 18 GHz Preamplifier

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Ethernet Media Converters

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

User s Guide F-SM-MM-02 Stand-Alone Media Converter Fast Ethernet or ATM Singlemode to Multimode

OM2000N INSTALLATION MANUAL

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

-TECH DIGITAL. Explore The High DefinitionWorld. Website: Hot Line: [US] USER MANUAL

Process Transmitter RMA 422

Transcription:

User Guide 6645-2204 MCW-211 S E R I E S Westermo Teleindustri AB Industrial Ethernet Media Converter www.westermo.com

Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at the following Internet address: http://www.westermo.com 2 6645-2204

Safety!!! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. This unit uses convection cooling.to avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section). Before mounting, using or removing this unit: Prevent access to hazardous voltage by disconnecting the unit from power supply. Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Class 1 Laser Product Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations. Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are no user serviceable parts inside. Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not paint the unit. Paint can clog the unit and prevent proper operation. Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels. Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied. 6645-2204 3

Note. Fibre Optic Handling Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/ receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way. If this recommendation not will be followed it can jeopardise the warranty. Cleaning of the optical connectors In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick. Recommended cleaning fluids: Methyl-, ethyl-, isopropyl- or isobutyl-alcohol Hexane Naphtha Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions. 4 6645-2204

Article number, model and description Article Model Description 3645-0001 MCW-211-MM-SC2 10/100Base-T/TX: 1 port 100Base-FX: 1 port 3645-0010 MCW-211-MM-ST2 10/100Base-T/TX: 1 port 100Base-FX: 1 port 3645-0020 MCW-211-SM-SC15 10/100Base-T/TX: 1 port 100Base-FX: 1 port 3645-0030 MCW-211-SM-LC15 10/100Base-T/TX: 1 port 100Base-FX: 1 port 3645-0040 MCW-211-SM-LC40 10/100Base-T/TX: 1 port 100Base-FX: 1 port 3645-0050 MCW-211-MM-LC2 10/100Base-T/TX: 1 port 100Base-FX: 1 port Agency approvals and standards compliance Type Approval / Compliance EMC EN 61000-6-2, Immunity industrial environments EN 61000-6-4, Emission industrial environments Marine DNV GL rules for classification Ships and offshore units¹ Note ¹ Applicable only for 3645-0030, 3645-0040, 3645-0050 Corrosive environment Notice: This product has been successfully tested in a corrosion test according to IEC 60068-2-60, method 4. This means that the product meets the requirements to be placed in an environment classified as ISA-S71.04 class G3. Note! If the product is placed in a corrosive environment, it is important that all unused connector sockets are protected with a suitable plug in order to avoid corrosion attacks on the gold plated pins in connectors. 6645-2204 5

Declaration of Conformity Westermo Teleindustri AB Declaration of Conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model Art no Industrial Ethernet Media Converter MCW-211 series 3645-0001, -0010, -0020, -0030, -0040, -0050 is in conformity with the following EU directive(s). No Short name 2014/30/EU Electromagnetic Compatibility (EMC) 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) References of standards applied for this EU declaration of conformity. No Title Issue EN 61000-6-2 Electromagnetic compatibility Immunity for industrial 2005 environments EN 61000-6-4 Electromagnetic compatibility Emission for industrial 2007 environments EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances 2012 The last two digits of the year in which the CE marking was affixed: 16 Pierre Öberg Technical Manager 22 nd March 2016 Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 6 6645-2204

Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test Description Level ESD EN 61000-4-2 Enclosure contact ± 4 kv Enclosure air ± 8 kv RF field AM modulated IEC 61000-4-3 Enclosure 10 V/m 80% AM (1 khz), 30 2700 MHz Fast transient EN 61000-4-4 Signal ports ± 1 kv Power ports ± 2 kv Surge EN 61000-4-5 Signal ports balanced ± 2 kv line to earth, ± 1 kv line to line Power ports ± 2 kv line to earth, ± 2 kv line to line RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 khz), 0.15 80 MHz Voltage dips and interruption Radiated emission CISPR 16-2-3 ANSI C63.4 (FCC part 15) Power ports 10 V 80% AM (1 khz), 0.15 80 MHz EN 61000-4-29 DC power ports 10 ms, interruption 10 ms, 30% reduction 10 ms, 60% reduction +20% above & 20% below rated voltage Enclosure Class A Conducted emission CISPR 16-2-1 DC power ports Class A Dielectric strength EN 60950 Signal port to other isolated ports Environmental Temperature EN 60068-2-1 EN 60068-2-2 Power port to other isolated ports Operating Maximum surface temperature Storage & Transport 1.5 kvrms 50 Hz 1 min 2 kvrms 50 Hz 1 min 25 to +70ºC 135 C (temperature class T4) 40 to +70ºC Humidity EN 60068-2-30 Operating 5 to 95% relative humidity Storage & Transport 5 to 95% relative humidity Altitude Operating 2 000 m / 70 kpa Service life Operating 10 year Vibration IEC 60068-2-6 Operating 7.5 mm, 5 8 Hz 2 g, 8 500 Hz Shock IEC 60068-2-27 Operating 15 g, 11 ms Packaging Enclosure, MCW-211 UL 94 PC / ABS Flammability class V-1 Enclosure, MCW-211 Ex Cabelec 6141 Dimension W x H x D Weight 35 x 121 x 119 mm 0.25 kg Degree of protection IEC 529 Enclosure IP 21 Cooling Mounting Convection Horizontal on 35 mm DIN-rail 6645-2204 7

Interface specifications Power Rated voltage Operating voltage Rated current Rated frequency Inrush current I2t Startup current* Polarity Redundant power input Isolation to Connection 12 to 48 VDC 10 to 60 VDC 200 ma @ 12 VDC 100 ma @ 24 VDC 50 ma @ 48 VDC DC 0.03 A²s @ 12 VDC 0.75 A peak Reverse polarity protected Yes Ethernet TX Ethernet FX Detachable screw terminal Connector size 0.2 2.5 mm² (AWG 24 12) Shielded cable * Direction relative this unit Not required Ethernet TX Electrical specification Data rate Duplex Transmission range Isolation to Connection Ethernet FX Optical specification Data rate Duplex Connection IEEE std 802.3. 2000 Edition 10 Mbit/s or 100 Mbit/s, manual or auto Full or half, manual or auto 100 m Power RJ-45 IEEE std 802.3. 2000 Edition 100 Mbit/s Full or half SC, ST or LC 8 6645-2204

Location of interface ports and LED s LED Indicators (for details see page 13) DIP switches are accessible under the lid Ethernet TX RJ-45 Position Direction* Description 1 In/Out TD+ 2 In/Out TD 3 In/Out RD 4 5 6 In/Out RD 7 8 * Direction relative this unit Ethernet FX SC, ST or LC Position Direction* Description Product marking Rx In Receive port Rx Tx Out Transmit port * Direction relative this unit Power Position Direction* Description Tx Product marking 1 Common COM 2 In + Voltage A +VA 3 In + Voltage B +VB * Direction relative this unit 6645-2204 9

Fibre optic power budget Model Transmitted wavelength Min. output power, transmitter Max. output power, transmitter Input sensitivity, receiver Min. power budget Max. power budget Recommended fibre cable and core / cladding diameter MCW-211-MM xx2 MCW-211-SM SC15 MCW-211-SM LC15 MCW-211-SM LC40 1310 nm 1310 nm 1310 nm 1310 nm 19 dbm 15 dbm 15 dbm 5 dbm 12 dbm 8 dbm 8 dbm 0 dbm 31 dbm 34 dbm 31 dbm 34 dbm 12 dbm 19 dbm 16 dbm 29 dbm 19 dbm 26 dbm 23 dbm 34 dbm Multimode 50/125, 62.5/125 Singlemode 9/125, 10/125 Singlemode 9/125, 10/125 Singlemode 9/125, 10/125 Fibre type Normal attenuation @ 1310 nm multimode Normal attenuation @ 1310 nm singlemode 50/125 3.0 dbm/km 62,5/125 3.5 dbm/km 9/125 0.5 dbm/km 10/125 0.5 dbm/km Attenuation in connectors / splices Type Connector Fusion splice Mechanical splice Normal attenuation 0.2 0.4 dbm 0.1 dbm 0.2 dbm 10 6645-2204

LED indicators LED indicators are available on the front panel and on the RJ-45 TX connector. LED Status Description PWR Internal power, initialising OK Slow flash Initialisation progressing Fast flash Initialisation error LINK TX OFF No Ethernet link TX Flash Good Ethernet link TX Ethernet data is transmitted or received on TX interface LINK FX OFF No Ethernet link FX Flash Good Ethernet link FX Ethernet data is transmitted or received on FX interface FX DPX OFF Half dupex FX interface Full duplex FX interface LFF OFF Link fault forward is not active Link fault forward is active and has shutdown an interface LED Status Description SPD OFF 10 Mbit/s TX interface 100 Mbit/s TX interface DPX OFF Half duplex TX interface Full duplex TX interface SPD TX DPX 6645-2204 11

! Installation Mounting / Removal Before mounting or removing the unit: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. Mounting This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate. This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit. Snap on mounting, see figure 10 mm * (0.4 inches) 25 mm CLICK! * Spacing (left/right) recommended for full operating temperature range 25 mm Removal Press down the black support at the back of the unit, see figure. 12 6645-2204

Configuration DIP switches are accessible under the lid on top of the unit. DIP switches are used to configure the unit.! DIP-switch settings Before DIP-switch settings: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). NOTE DIP-switch alterations are only effective after a power on. To be observe when the DIP-switches will be configured Speed and duplex setting only valid when auto-negotiation is disabled. If auto-negotiation and auto MDI/MDI-X disabled the TX ports supports MDI-X configuration. 6645-2204 13

TX Port settings Flow control setting Auto-negotiation and auto MDI / MDI-X disabled TX port Flow control disabled Auto-negotiation and auto MDI / MDI-X enabled TX port Flow control enabled 10 Mbit/s speed selected TX port Link fault forward settings 100 Mbit/s speed selected TX port TX FX Link fault forward disabled Half duplex selected TX port TX FX Link fault forward enabled Full duplex selected TX port FX TX Link fault forward disabled FX Port settings FX TX Link fault forward enabled Half duplex selected FX port Factory settings Full duplex selected FX port 14 6645-2204

Westermo SE-640 40 Stora Sundby, Sweden Tel +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com www.westermo.com Sales Units Westermo Data Communications China sales.cn@westermo.com www.cn.westermo.com France infos@westermo.fr www.westermo.fr Germany info@westermo.de www.westermo.de North America info@westermo.com www.westermo.com Singapore sales@westermo.com.sg www.westermo.com Sweden info.sverige@westermo.se www.westermo.se United Kingdom sales@westermo.co.uk www.westermo.co.uk Other Offices For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code REV. C 6645-2204 2016-11 Westermo Teleindustri AB, Sweden