Color Doppler Twinkling Artifact and Clinical Use

Similar documents
The role of the acoustic radiation force in color Doppler twinkling artifacts

The Diagnosis of Small Solitary Pulmonary Nodule:

Chapter 7. Scanner Controls

Lesson 07: Ultrasound Transducers. This lesson contains 62 slides plus 16 multiple-choice questions.

Equipment selection and instrumentation

Chapter 6. Imaging System Components

White Paper. Uniform Luminance Technology. What s inside? What is non-uniformity and noise in LCDs? Why is it a problem? How is it solved?

1 About the Terason Ultrasound System

UGEO H60 PERFORMANCE IN STYLE

Ultrasound instrumentation and image formation. Lecturer: Chelsea Munding September 28 th, 2017

ESE-10 Multipurpose Color Ultrasound System IMAGING SYSTEMS

1 About the usmart3200t Ultrasound System

Vascular. Development of Trinias FPD-Equipped Angiography System. 1. Introduction. MEDICAL NOW No.73 (2013.2) Yoshiaki Miura

+ Human method is pattern recognition based upon multiple exposure to known samples.

A Noble Identification System for Tumors and Implementation

DICOM. image protocol

Solution for Nonuniformities and Spatial Noise in Medical LCD Displays by Using Pixel-Based Correction

JEE 4980 Senior Design

All the Knowledge You Need About Ultrasound Maintenance and Imaging Artifacts

ClarUs Mac TELEMED ULTRASOUND DIAGNOSTIC SYSTEM INFO

Spatio-temporal inaccuracies of video-based ultrasound images of the tongue

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Bioengineering 508: Physical Aspects of Medical Imaging Nature of Medical Imaging. Nature of Medical Imaging

Litho. Taking care of people, our masterpieces. Surgical Laser System. Surgery

Enhanced Diagnostics through Ultrasound Imaging

More Info at Open Access Database Process Control for Computed Tomography using Digital Detector Arrays

COMPUTER APPLICATIONS

Abstract. Learning Objectives 8/1/2017

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

ClarUs EXT TELEMED ULTRASOUND DIAGNOSTIC SYSTEM INFO

loss in frame rate. 3. Color flow with capability of automatically picking up color flow as a function of focal depth. 4. Color Angiography.

SmartUs TELEMED ULTRASOUND DIAGNOSTIC SYSTEM INFO

True comfort and flexibility with the power of 3T.

DUB SkinScanner. in medicine and cosmetic. high frequency ultrasound since 1978

EMI/EMC diagnostic and debugging

A PSYCHOACOUSTICAL INVESTIGATION INTO THE EFFECT OF WALL MATERIAL ON THE SOUND PRODUCED BY LIP-REED INSTRUMENTS

Sending Images. Teacher Information

Role of Color in Telemedicine Applications. Elizabeth A. Krupinski, PhD

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

DISTRIBUTION STATEMENT A 7001Ö

APP USE USER MANUAL 2017 VERSION BASED ON WAVE TRACKING TECHNIQUE

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

ULTRASOUND REVOLUTION CONTINUES

Elasticity Imaging with Ultrasound JEE 4980 Final Report. George Michaels and Mary Watts

New Medical Light Source using NTT s Communication Laser Technology

Lecture 1: What we hear when we hear music

DIGITAL COMMUNICATION

Measurement of overtone frequencies of a toy piano and perception of its pitch

M R I Physics Course. Jerry Allison Ph.D. Chris Wright B.S. Tom Lavin M.S.M.P. Department of Radiology Medical College of Georgia

Perfecting the Package Bare and Overmolded Stacked Dies. Understanding Ultrasonic Technology for Advanced Package Inspection. A Sonix White Paper

Understanding Fidelity

Scalable Low cost Ultrasound Beam former

APPLICATIONS OF DIGITAL IMAGE ENHANCEMENT TECHNIQUES FOR IMPROVED

4.9 BEAM BLANKING AND PULSING OPTIONS

Standard Operating Procedure of nanoir2-s

Pitch-Synchronous Spectrogram: Principles and Applications

Chapter 6: Real-Time Image Formation

Open loop tracking of radio occultation signals in the lower troposphere

onitoring Bearing Vibration with Seismic Transducers

Machinery Diagnostic Plots Part 1 ORBIT Back-to-Basics: What does the data really tell us?

The Syscal family of resistivity meters. Designed for the surveys you do.

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

World First Slim Cassette Type Digital Mammo. Upgrade Solution

ANTENNAS, WAVE PROPAGATION &TV ENGG. Lecture : TV working

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Comparison of Measured Values of CTDI and DPL with Standard Reference values of Different CT Scanners for dose Management

4. ANALOG TV SIGNALS MEASUREMENT

An Overview of Video Coding Algorithms

Audio-Based Video Editing with Two-Channel Microphone

AN ARTISTIC TECHNIQUE FOR AUDIO-TO-VIDEO TRANSLATION ON A MUSIC PERCEPTION STUDY

COMPARED IMPROVEMENT BY TIME, SPACE AND FREQUENCY DATA PROCESSING OF THE PERFORMANCES OF IR CAMERAS. APPLICATION TO ELECTROMAGNETISM

Removing the Pattern Noise from all STIS Side-2 CCD data

G635. APPLIED SCIENCE Working waves ADVANCED GCE. Wednesday 27 January 2010 Morning. Duration: 1 hour 30 minutes

Figure 2: Original and PAM modulated image. Figure 4: Original image.

Automatic LP Digitalization Spring Group 6: Michael Sibley, Alexander Su, Daphne Tsatsoulis {msibley, ahs1,

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

DAT335 Music Perception and Cognition Cogswell Polytechnical College Spring Week 6 Class Notes

Instrument Recognition in Polyphonic Mixtures Using Spectral Envelopes

Acoustical comparison of bassoon crooks

Power. Flexibility. Usability.

Quick reference guide

Real-time QC in HCHP seismic acquisition Ning Hongxiao, Wei Guowei and Wang Qiucheng, BGP, CNPC

Auto classification and simulation of mask defects using SEM and CAD images

Phantom Test Guidance for Use of the Small MRI Phantom for the MRI Accreditation Program

Speech and Speaker Recognition for the Command of an Industrial Robot

Signal to noise the key to increased marine seismic bandwidth

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

1 Ver.mob Brief guide

Signal processing in the Philips 'VLP' system

3/2/2016. Medical Display Performance and Evaluation. Objectives. Outline

Communication Theory and Engineering

THE DIGITAL DELAY ADVANTAGE A guide to using Digital Delays. Synchronize loudspeakers Eliminate comb filter distortion Align acoustic image.

Mammo Tomosynthesis 5MP

Various Applications of Digital Signal Processing (DSP)

XC-77 (EIA), XC-77CE (CCIR)

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

EDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION

Reconstruction of Ca 2+ dynamics from low frame rate Ca 2+ imaging data CS229 final project. Submitted by: Limor Bursztyn

Transcription:

See discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/241102468 Color Doppler Twinkling rtifact and Clinical Use rticle in Journal of Medical Ultrasound December 2009 DOI: 10.1016/S0929-6441(09)60122-3 CITTIONS 7 REDS 56 6 authors, including: Mein-Kai Gueng Taichung Veterans General Hospital 23 PULICTIONS 184 CITTIONS SEE PROFILE San-Kan Lee Taichung Veterans General Hospital 143 PULICTIONS 966 CITTIONS SEE PROFILE ll content following this page was uploaded by Mein-Kai Gueng on 05 January 2016. The user has requested enhancement of the downloaded file.

R E V I E W R T I C L E Color Doppler Twinkling rtifact and Clinical Use Teng-Fu Tsao 1 3, Ruei-Jin Kang 4, Mein-Kai Gueng 5, Yeu-Sheng Tyan 1,2, Yung-Chang Lin 3, San-Kan Lee 2,5 * The color Doppler twinkling artifact manifests as a rapidly changing mixture of red and blue colors behind a strongly reflecting structure. Spectral Doppler analysis of the twinkling artifact does not yield a flow spectrum. It is important to recognize this artifact because it may lead to misdiagnosis of vascular flow within a tissue. dditionally, the artifact may be considered a sonographic sign in the detection of calcifications and calculi. In this article, we review the history of the interesting phenomenon and its clinical use, as well as our personal experiences of the artifact. Key Words color Doppler, twinkling artifact, ultrasound J Med Ultrasound 2009;17(3):157 166 Introduction The color Doppler twinkling artifact manifests as a rapidly changing mixture of red and blue colors behind a strongly reflecting structure [1]. The roughness of the reflecting surface is directly related to the intensity of the twinkling artifact [2]. Kamaya et al reported that the appearance of the twinkling artifact was highly dependent on machine settings such as pulse repetition frequency, color-write priority, and grayscale gain, and is probably generated by a narrow-band, intrinsic machine noise, called phase (or clock) jitter [3]. This artifact has been described behind calcifications and calculi in various tissues including prostate, testis, kidney, bladder, liver, gallbladder, breast [1], ureter [4], orbit [5], encrusted indwelling ureteral stents [6], and calcified pancreatitis [7]. dditionally, twinkling artifacts in gallbladder adenomyomatosis [8] and intrauterine fetal demise [9] have also been reported, although the presentation or absence of associated calcifications was not well established in the two original reports. Twinkling rtifact In Vitro Conventional Doppler evaluations determine the velocity of the flow based on a frequency shift in the transmitted signal due to the motion of the target. Received: June 24, 2009 ccepted: ugust 6, 2009 1 Department of Medical Imaging, Chung Shan Medical University Hospital, 2 School of Medical Imaging and Radiological Sciences, Chung Shan Medical University, 3 Department of Veterinary Medicine, National Chung Hsing University, 4 National Chi Nan University, 5 Department of Radiology, Taichung Veterans General Hospital, Taiwan. *ddress correspondence to: San-Kan Lee, Department of Radiology, Taichung Veterans General Hospital, 160, Sec. 3, Chung-Kang Road, Taichung 407, Taiwan, R.O.C. E-mail: sklee@vghtc.gov.tw Elsevier & CTSUM. ll rights reserved. J Med Ultrasound 2009 Vol 17 No 3 157

T.F. Tsao, R.J. Kang, M.K. Gueng, et al Fig. 1. In vitro study of the twinkling artifact can prevent the interference of motion artifacts or misinterpretation of vascular flows. () Color Doppler image of urolithiasis in a water bath with a fixed probe and a red-and-blue color map shows mixed red and blue colors behind the urolithiasis. () Photograph shows the irregular surface of the urolithiasis. Therefore, underlying motion may potentially influence the appearance of the Doppler signal, including the twinkling artifact. To evaluate the evidence and the characteristics of the twinkling artifact, in vitro observations without the interference of motion artifacts or vascular flows were performed before further clinical examination [1,3,4]. The color Doppler twinkling artifact, manifests as a rapidly changing mixture of red and blue colors behind a strongly reflecting structure, was first described by Rahmouni et al [1] (Fig. 1). The color change is not in any identifiable order [1]. The physical nature of the reflecting surface plays the most important role in the formation of the twinkling artifact. Rahmouni et al [1] proposed that the artifact is generated by rough surfaces with multiple reflectors splitting the incident beam into a complex beam pattern. This was thought to create an increased pulse duration of the received radiofrequency signal, that is then interpreted as movement [1]. The roughness of the reflecting surface is directly related to the strength of the twinkling artifact, as noted in our previous report on a quantitative analysis of the artifact with water sandpapers [2] (Fig. 2). In addition, the angle between the ultrasound beam and the reflecting surface affects the intensity of the artifact [2] (Fig. 3). In color Doppler imaging, based on the principles of pulsed Doppler ultrasound, the twinkling artifact occurs behind the near-field interface of the object for a finite distance, often beyond the actual object causing the artifact. This artifact is present regardless of the velocity, wall filter setting, probe frequency, focal depth, probe-to-interface distance, or color Doppler system [1]. However, parameters such as the depth of focal zone, color-write priority, grayscale gain, and pulse repetition frequency have a complex influence on the twinkling artifact [3,4,10] (Fig. 4). The influence of these parameters supports a hypothesis that the artifact is generated by a narrow-band, intrinsic machine noise called phase (or clock) jitter [3] (Fig. 5). This theory suggests that roughness alone is not capable of producing this artifact [3]. The signal intensity of the twinkling artifact on color Doppler imaging has been discussed in previous reports. The first classification was made by Rahmouni et al [1] who classified the artifact into three grades: absence of twinkling = 0, weak twinkling = 1+, and strong twinkling = 2+. Chelfouh et al [11] also classified the signal intensity into 3 grades: 0, the twinkling artifact is absent; 1, the artifact occupies a portion of acoustic shadowing; 2, the artifact occupies the entire acoustic shadowing. Furthermore, Kamaya et al [3] calculated the total 158 J Med Ultrasound 2009 Vol 17 No 3

Twinkling rtifact and Clinical Use C Strength of the twinkling artifact (number of color pixels) 1,4000 1,2000 1,0000 8,000 6,000 4,000 2,000 0 y = 146.3 516.2 0 20 40 60 80 100 Particle size of water sandpaper (micron) Fig. 2. The roughness of the reflecting surface is directly related to the intensity of the twinkling artifact as demonstrated from a quantitative analysis using water sandpapers. () Photograph of the water sandpaper used, an extra fine silicon carbide sandpaper. The number 320 (arrows) refers to the size of the grit (CMI standard), representing the average particle size of 0.00140 inch or 36 micron. () Close-up of the water sandpapers. Six different grit sandpapers were lined up from coarse to fine (left to right); the grit sizes range from 180 (78.0 microns), 240 (58.5 microns), 320 (36.0 microns), 600 (25.75 microns), 800 (21.8 microns), to 1,200 (15.3 microns). (C) Color Doppler images of water sandpapers in a water bath as showed in. Twinkling artifacts were identified more strongly behind sandpapers with greater surface roughness than those with lesser surface roughness. (D) Illustration of the relationship between the particle size of sandpapers (roughness of the reflecting surface) and the strength of the twinkling artifact. The number of color pixels behind each sandpaper has a positive linear relationship with the roughness of the reflecting surface (r = 0.92). (dapted and reprinted, with permission, from reference 2.) D number of color pixels in a quantitative analysis of the twinkling artifact. In our experience, each of the 3-grade methods suitably describes the signal intensity of the artifact in most clinical situations, and the calculation of color pixels is the most accurate method of measurement and is useful for quantitative analysis [2,3]. The twinkling artifact can be observed on color, power, and spectral Doppler images [1,4]. In our experience, the twinkling signals in power Doppler images can be identical to vascular flow and the interpretation of the artifact in power Doppler mode alone may be inappropriate. On the other hand, if the artifact is recognized in power Doppler images it can be theoretically calculated without the interference of the vascular flow. Spectral Doppler analysis of the twinkling artifact does not yield a flow spectrum, but shows serial J Med Ultrasound 2009 Vol 17 No 3 159

T.F. Tsao, R.J. Kang, M.K. Gueng, et al No. of color pixel 14,000 12,000 10,000 8,000 6,000 4,000 2,000 0 n 180 0 20 40 60 80 100 Doppler angle Raw data cosine θ Mean (raw data cosine θ) Fig. 3. The relationship between the Doppler angle and the intensity of the twinkling artifact is illustrated in vitro. () The sandpaper is scanned in a water bath with a fixed probe. Here, if the ultrasound beam (arrows) is positioned perpendicularly to the sandpaper (arrowheads), the Doppler angle is defined as 0 (left panel). If the ultrasound beam deviates from 90, the Doppler angle is defined as q (middle panel, 25 ; right panel, 60 ). () Representative graph illustrates the relationship between the Doppler angle and the intensity of twinkling artifact using 78.0 micron sandpaper (number 180). The total number (raw data) of color pixels in each column is corrected with cosine q. Thus, the result of raw data cosine q indicates the twinkling artifact signal intensity per area. Each point stands for 5 different experiments. Note the Doppler angle would obviously affect the intensity of the artifact only in the steeper angles. (dapted and reprinted, with permission, from reference 2.) vertical bands with saturated amplitudes [1,3 5]. This band-like spectrum is considered a specific pattern of the twinkling artifact and is used to identify the twinkling artifact in vivo. The spectrum should not be confused with the aliasing artifact. Twinkling rtifact in Urolithiasis In clinical practice, the twinkling artifact may improve the detection and analysis of urolithiasis. The color Doppler twinkling artifact is usually located at the site where one finds or expects an acoustic shadow (Fig. 6). In a prospective study, Lee et al [4] reported that twinkling artifact appeared in 80% of cases of renal stone and 88% of cases of ureteral stones. Furthermore, they found one of the renal stones with the twinkling artifact was lucent on unenhanced radiography and exhibited indiscrete posterior shadowing on grayscale ultrasound. To differentiate the twinkling artifact from normal flow signals of the renal arteries or veins, one may use a probe with a high color velocity scale setting. The twinkling artifact tends to persist when the color velocity scale is increased, but blood flow signals tend to disappear [1] (Fig. 7). Spectral Doppler may be used to confirm the twinkling artifact. The spectrum is composed of close vertical bands with saturated amplitudes as described in the earlier section of this article (Fig. 8). In an analysis of the urolithiasis, Chelfouh et al [11] found an in vitro relationship between the presence of the twinkling artifacts and the morphology of stones. Stones with rough surfaces produced more 160 J Med Ultrasound 2009 Vol 17 No 3

Twinkling rtifact and Clinical Use Grayscale gain Colorwrite priority Grayscale gain = 1 (Column 1) Grayscale gain = 20 (Column 2) Grayscale gain = 40 (Column 3) Color-write priority = 90% (Row 1) Color-write priority = 50% (Row 2) Color-write priority = 10% (Row 3) Fig. 4. complex relationship between color-write priority, grayscale gain, and the appearance of the twinkling artifact is showed in vitro. Six different grit sandpapers are lined from coarse to fine (left to right); the sequence goes from 180, 240, 320, 600, 800 to 1,200 (same as Figure 2). Twinkling artifact is identified more strongly behind sandpaper with greater surface roughness (e.g., 180) than that with less surface roughness (e.g., 1,200). The intensity of the twinkling artifact is inversely related to the grayscale gain (the signal intensity is stronger in column 1 than columns 2 and 3) for any different settings of color-write priority, although this effect is less obvious in situations of high priority settings (e.g., row 1). (dapted and reprinted, with permission, from reference 10.) Note that the result is different from the study by Kamaya et al [3]. twinkling artifacts than those with smooth surfaces. In correlating the chemical composition of the stones with the appearance of the twinkling artifacts it has been found that stones made of calcium oxalate dihydrate produce the twinkling artifact, whereas those composed predominantly of calcium oxalate monohydrate typically do not. ased on these results, the presence of the twinkling artifact on color Doppler imaging may help predicting the efficacy of fragmentation of stones before extracorporeal shock wave lithotripsy. Pure monohydrate calculi are extremely dense and resistant, whereas pure or predominantly calcium oxalate dihydrate stones are much more fragile and consequently are good candidates for extracorporeal shock wave lithotripsy. Trillaud et al [6] reported two cases of the identification of encrusted indwelling ureteral stents using the twinkling artifact. In one case, an early encrusted stent which was difficult to diagnose on unenhanced radiography was easily identified from the twinkling artifact. Thus, it appears that the twinkling artifact may play an important role in the diagnosis of encrustation of ureteral stents. Other Clinical Uses of the Twinkling rtifact In addition to it use in diagnosing urolithiasis, the twinkling artifact has been reported useful in other clinical situations. Ustymowicz et al [5] reported the presence of the artifact in the orbit. In one patient, a metallic foreign body was present just behind the bulb. In another, there was a calcification within an irregular mass of phthisis bulbi. nd in a third J Med Ultrasound 2009 Vol 17 No 3 161

T.F. Tsao, R.J. Kang, M.K. Gueng, et al C Fig. 5. The color Doppler twinkling artifact is probably generated by a narrow-band, intrinsic machine noise. () Color Doppler image of urolithiasis (same as Figure 1) in vitro obtained with a color gain setting of 25% shows the twinkling artifact as mixed red and blue colors behind the urolithiasis. () The twinkling artifact is more obvious when the color gain is increased into 45%. (C) The twinkling artifact is blended into saturated background color noises when the color gain is intentionally increased into 65%. The signals of the twinkling artifact are identical to that of background color noises in this setting. patient, a hyperechoic drusen in the periphery of the intraocular melanoma was noted. Twinkling artifacts have also been reported in gallbladder adenomyomatosis [8] and intrauterine fetal demise [9], although the presence or absence of an associated calcification was not well established in the reports. Furthermore, Ozkur et al [9] observed that the intensity of the artifact was correlated with time elapsed since intrauterine death. They explained this phenomenon by the fact that the calcification and roughness of the fetal surface increases in a timedependent manner. The twinkling artifact has also been reported useful in the detection of calcified pancreatitis, as described in our previous report [7]. The presence of parenchymal calcifications is one of the features of chronic pancreatitis. However, these calcifications may be very subtle in grayscale ultrasound when they are small and do not have posterior acoustic shadowing. ecause of the heterogeneous texture of pancreatic parenchyma in some patients, detection of these tiny calcifications can be more difficult with grayscale ultrasound alone, as our previous cases illustrate (Fig. 9). In addition to diagnostic imaging, the twinkling artifact is useful in sonographically guided needle puncture (Fig. 10). Gorguner et al [12] was the first to describe the improvement of needle tip visualization using the color Doppler twinkling artifact. In their study, the needle tip was observed in 81.3% cases on color Doppler images, but in only 18.8% of cases on grayscale images. dditionally, the pump maneuver, an atraumatic method to produce a grayscale sonographic artifact at the needle tip also seemed to enhance the color Doppler twinkling artifact [12,13]. 162 J Med Ultrasound 2009 Vol 17 No 3

Twinkling rtifact and Clinical Use C D E Fig. 6. The use of the twinkling artifact in clinical practice may be the improved detection and analysis of urolithiasis. () Grayscale ultrasound reveals a hyperechoic stone with posterior shadowing (arrow in left panel) in one of the upper calyxes of the kidney. Color Doppler ultrasound shows the twinkling artifact located at the site where one finds an acoustic shadow (right panel). () In another case, the hyperechoic renal stone (arrow in left panel) without obvious posterior shadowing is hard to separate from the echoic renal sinus itself using grayscale ultrasound. The situation of the case presents a diagnostic problem. Fortunately, color Doppler ultrasound shows the twinkling artifact clearly (right panel). The diagnosis of urolithiasis is confirmed by plain film radiography (arrow in C). (D) The residual tiny stone after extracorporeal shock-wave lithotripsy (ESWL) is difficult to detect by grayscale ultrasound (left panel) but is easy by color Doppler ultrasound because of the twinkling artifact (right panel). Plain film radiography of the same case shows multiple small fragments of the renal stone (arrows in E). Conclusion The color Doppler twinkling artifact is highly associated with rough reflecting surfaces and highly dependent on machine settings. The presence of a color signal close to calcifications should always be interpreted with caution. The presence of the twinkling artifact must not be mistaken for an abnormal vascular lesion. Furthermore, the twinkling artifact improves the detection of calcifications and calculi in various tissues in clinical practice and needle tip visualization in sonographically guided needle J Med Ultrasound 2009 Vol 17 No 3 163

T.F. Tsao, R.J. Kang, M.K. Gueng, et al Fig. 7. The high color velocity scale setting may help to differentiate the twinkling artifact from normal vascular flow signals in clinical practice. The normal renal arterial or venous flow signals (arrows in left panel) contaminate the image obtained with a color velocity setting of 20 cm/s. The twinkling artifact (arrow in right panel) can be enhanced by increasing the color velocity to 70 cm/s. Note that most flow signals disappear in the right panel compared to the left panel. Fig. 8. Spectral Doppler is useful to confirm the diagnosis of the twinkling artifact. In the case of a bladder stone, multiple vertical white bands with saturated amplitudes are typical of the twinkling artifact. C Fig. 9. The twinkling artifact is useful in the detection of calcified pancreatitis. () Oblique transverse abdominal ultrasound revealed heterogeneous hyperechoic pancreatic parenchyma. Multiple tiny intraparenchymal hyperechoic foci with small posterior reverberations (arrows) were also noted (arrowhead, superior mesenteric artery). () Color Doppler ultrasound revealed obvious twinkling artifacts behind each hyperechoic focus (arrows). (C) Multiple parenchymal punctate calcifications (arrows) within the atrophic pancreas on the non-enhanced abdominal computed tomography (CT image). (dapted and reprinted, with permission, from reference 7.) 164 J Med Ultrasound 2009 Vol 17 No 3

Twinkling rtifact and Clinical Use C D Fig. 10. The twinkling artifact improves the visualization of the needle tip in sonographically guided puncture. () The puncture needle is poorly visualized in the grayscale ultrasound image in the phantom study. () With a small-ranged quick manual vibration, the needle is enhanced colorfully by motion artifacts. However, identification the needle tip is still uncertain using the manual vibration technique. In another scan, the puncture needle is also poorly visualized by the grayscale ultrasound (C) With proper machine settings, the color Doppler twinkling artifact discloses the needle tip, which is usually a little rough. puncture. Understanding of the complex machine settings may result in better clinical application of the artifact. References 1. Rahmouni, argoin R, Herment, et al. Color Doppler twinkling artifact in hyperechoic regions. Radiology 1996;199:269 71. 2. Tsao TF, Tyan YS, Kang RJ, et al. Correlation study of the strength of the color Doppler twinkling artifact with the roughness of the reflecting surface and the Doppler angles. J Med Ultrasound 2004;12:119 24. 3. Kamaya, Tuthill T, Rubin JM. Twinkling artifact on color Doppler sonography: dependence on machine parameters and underlying cause. JR m J Roentgenol 2003;180:215 22. 4. Lee JY, Kim SH, Cho JY, et al. Color and power Doppler twinkling artifacts from urinary stones: clinical observations and phantom studies. JR m J Roentgenol 2001;176:1441 5. 5. Ustymowicz, Krejza J, Mariak Z. Twinkling artifact in color Doppler imaging of the orbit. J Ultrasound Med 2002;21:559 63. 6. Trillaud H, Pariente JL, Rabie, et al. Detection of encrusted indwelling ureteral stents using a twinkling artifact revealed on color Doppler sonography. JR m J Roentgenol 2001;176:1446 8. 7. Tsao TF, Kang RJ, Tyan YS, et al. Color Doppler twinkling artifact related to chronic pancreatitis with parenchymal calcification. cta Radiol 2006;47: 547 8. J Med Ultrasound 2009 Vol 17 No 3 165

T.F. Tsao, R.J. Kang, M.K. Gueng, et al 8. Ghersin E, Soudack M, Gaitini D. Twinkling artifact in gallbladder adenomyomatosis. J Ultrasound Med 2003;22:229 31. 9. Ozkur, Dikensoy E, Kervancioglu S, et al. Color Doppler twinkling artifact in intrauterine fetal demise. J Clin Ultrasound 2008;36:153 6. 10. Tsao TF, Kang RJ, Gueng MK, et al. Establishment of a simple model system for the evaluation of color Doppler twinkling artifact (poster). Presented at the 53rd nnual Meeting of the Radiological Society of the Republic of China, 2004 Taipei, Taiwan. 11. Chelfouh N, Grenier N, Higueret D, et al. Characterization of urinary calculi: in vitro study of twinkling artifact revealed by color-flow sonography. JR m J Roentgenol 1998;171:1055 60. 12. Gorguner M, Misirlioglu F, Polat P, et al. Color Doppler sonographically guided transthoracic needle aspiration of lung and mediastinal masses. J Ultrasound Med 2003;22:703 8. 13. isceglia M, Matalon T, Silver. The pump maneuver: an atraumatic adjunct to enhance US needle tip localization. Radiology 1990;176:867 8. 166 J Med Ultrasound 2009 Vol 17 No 3 View publication stats