New output class 1600 W

Similar documents
Roof-mounted Blue e+ cooling unit Integration solution VX25

Climate Solutions Handbook

Model KBF 115 Constant climate chambers with large temperature / humidity range

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Model KT 115 Cooling incubators with thermoelectric cooling

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

LED-Strip C12 MK2.6. Product Sheet

LED-Strip C25 MK2.6. Product Sheet

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Model KT 53 Cooling incubators with thermoelectric cooling

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

LED-Strip C50 MK2.6. Product Sheet

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Re-defining the utility-scale inverter

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

HARTING Ethernet cabling cables and connectors, 4 wire

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Air Conditioning Components and Equipments for Enclosures

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.

TUC: Universal thermostat

Dell Wyse 5030 PCoIP Zero Client

Series CT7N Bimetallic Overload Relays

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Industrial Wi-Fi Access Point and Client - DM500

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

IPS 2400 SMAVIA Appliance for up to 24 IP Channels, 8 3.5" HDD, 3 HU

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Easy programming Robust. Flexible. FPS Flexible Position Sensor FPS. Field of Application. Advantages Your benefit. Options and special Information

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43


CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LCS 2 RJ 45 Cat. 6A HD panels and units

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

HighBand 25. TrueNet Category 6 Solutions

Simple all-in-one design style with front stereo speakers and natural ventilation system

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

LCS2 Cat. 6 RJ 45 Patch panels and units

Model KT 170 Cooling incubators with thermoelectric cooling

Model KBF P 240 Humidity test chambers with ICH-compliant light source

10 PDUs 19 PDUs Zero-U PDUs

HDMI Over IP Extender Kit - 4K

Electrical connection

PRELIMINARY Sunny Boy 240-US

Series 3000 Dual Cast Transmitter

XR47-24 Models 24 W/ F (43 W/ C)

SoliTherm. Control Cabinet Air Conditioning....wegweisend innovativ

Single Point Flow Monitor SW118 SW119

Digital Clock with Second Circle DA Series

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Lt DELTA USA, Inc

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

LED HIGHBAY I-VALO XENRE

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Trusted 40 Channel 120 Vac Digital Input FTA

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

LMD-1541W. 15-inch high grade LCD monitor. Overview

Safety Light Curtains

Level Measurement silometer FMC 420, FMC 423

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

llen-bradley 194R-HM4-NFPA3

General Specifications

Model KBF 720 Constant climate chambers with large temperature / humidity range

Max. 4K Capabilities. Chroma Sampling 4:4:4. 4:2: bit³

Omega 4K/UHD Three-Input Switcher. Introduction. Applications. for HDMI and USB-C with HDBaseT and HDMI Outputs

Features. Specifications. Finish. Notes

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Process Transmitter RMA 422

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

NEC MultiSync P403. NEC LCD 40" Large Format Display DELIVERING GENUINE BENEFITS OUTSTANDING PERFORMANCE. Order Code: P403

istep STEPPER MOTOR PUMP

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

LD OEM/LD PDS/LD PeCo

Panel-mounting thermostats, type series EM

SPECTRO Series. SPECTRO-1-30-UV/VIS-9x1. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Flexibility and Safety. BERNSTEIN safety hinge switches

SCALE & WEIGHT DISPLAYS

Panel-Mounted Thermostat

Electrical connection

Safety Light Curtains GuardShield

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Trusted 40 Channel Analogue Input FTA

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

XR47-24 Models 24 W/ F (43 W/ C)

Cisco Video Surveillance 6400 IP Camera

Process transmitter RMA422

Transcription:

World s first The principle New output class 1600 W

2

The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power distribution, climate control and IT infrastructure products together into a single system platform. Complemented by our extensive range of software tools and global service, we create unique added value for trade and industry: Production plant, test equipment, facility management and data centres. In accordance with our simple principle, Faster better everywhere, we are able to combine innovative products and efficient service to optimum effect. Faster with our Rittal The System. range of modular solutions, which guarantees fast planning, assembly, conversion and commissioning with its system compatibility. Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages. Everywhere thanks to global networking: 13 production facilities with almost 250,000 m 2 production space worldwide 58 subsidiaries Around 90 warehouse facilities with more than 180,000 pallet locations and over 250,000 m 2 storage space worldwide 3

World s first The Blue e+ cooling unit series the ultimate in efficiency. Worldwide. The principle: Efficiency Average 75% energy savings thanks to speed-regulated components and heat pipe technology Versatility Suitable for international use due to unique multi-voltage capability Safety Longer service life of the components inside the enclosure and the cooling unit due to component-friendly cooling User-friendliness Intuitive operation due to touch display and intelligent interfaces 4

5

6

The principle Revolutionary energy efficiency with innovative hybrid technology Unbelievably efficient Let hybrid technology take your cooling units' energy efficiency to a whole new level Active cooling circuit with speed-regulated components for demand-based cooling Integral heat pipe for passive cooling dissipates heat from the enclosure as soon as the ambient temperature falls below the setpoint Transparent efficiency comparisons Energy Efficiency Ratio: The standardised efficiency ratio Seasonal Energy Efficiency Ratio: The seasonal efficiency ratio for actual energy consumption Amazingly economical Average 75% energy savings Component-friendly cooling for a longer service life A constant temperature inside the enclosure is ensured with three control modes High operational reliability Easier to calculate Determine your energy savings with the efficiency calculator TCO calculation includes all costs arising in the product's lifecycle Precise amortisation calculation Annual factory hall temperature profile 30 C Ambient temperature 25 C 20 C 15 C 10 C Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Month Rittal specifies the SEER to indicate the actual efficiency of a cooling unit, since a precise calculation must also consider the seasonal temperature variation. The standard point for determining the EER does not make allowance for actual fluctuations in hall temperatures. 7

8

The principle Simple operation with touch display and intelligent interfaces Get information faster Fast device analysis with RiDiag software via the USB interface Remote monitoring via Ethernet in conjunction with the IoT interface Blue e+ app Contactless information exchange and rapid, direct on-site analysis via an NFC interface Simple repair, maintenance and spare parts enquiries may be sent directly via your smartphone Save device data directly on the device IoT interface For linking Blue e+ cooling units and Blue e+ chillers to the customer's own monitoring, energy management and/or superordinate systems Analysis and parametrisation Device data can be supplied in most standard protocols Generate your own dashboards and analyses Attaches to the top hat rail or to the cooling unit itself Easier to operate Fast parameterisation, data reading and plain-text system messages on the intelligent, multi-lingual, industrial-grade display 9

10

The principle Versatility through standard assembly Easy assembly One version for external mounting, partial internal mounting and full internal mounting One mounting cut-out for external mounting, partial internal mounting and full internal mounting in multiple output categories Maintenance-friendly, tool-free filter mat replacement Fast assembly Handle for convenient transport and positioning Mounting clip as securing aid Eyebolts for easy mounting Maximum flexibility with unique multi-voltage capability One unit for all voltages and networks, suitable for worldwide use thanks to inverter technology: 110 240 V, 1~, 50 60 Hz 380 480 V, 3~, 50 60 Hz International approvals and certifications culus Listed EAC TÜV Nord GS TÜV Nord-tested output measurement culus FTTA 11

Wall-mounted cooling units Blue e+ Accessories for climate control Page 14 Therm software Cat. 35, page 474 RiDiag software Page 15 Benefits: Average 75% energy savings thanks to speed-regulated components and heat pipe technology Suitable for international use due to a unique multi-voltage capability Longer service life of the components inside the enclosure and the cooling unit due to component-friendly cooling Intuitive operation due to touch display and intelligent interfaces Temperature control: e+ controller (factory setting +35 C) Material: Sheet steel Colour: RAL 7035 Protection category IP to IEC 60529: Internal circuit IP 55 Supply includes: Assembly parts Fully wired ready for connection (plug-in terminal strip) Note: Please observe the mounting instructions. Approvals: Available on the Internet Performance diagrams: Available on the Internet H B T Output class 1600 W Model No. Packs of 3185.830 Page Total cooling output 50 Hz L35 L35 to DIN EN 14511 kw 1.6 Total cooling output 50/60 Hz L35 L35 kw 1.6 / 1.6 Total cooling output 50/60 Hz L35 L50 kw 1.2 / 1.2 Rated operating voltage V, ~, Hz 110-240, 1~, 50/60 380-480, 3~, 50/60 Width (B) mm 400 Height (H) mm 950 Depth (T) mm 310 Rated output kw 0.62 Power consumption P el 50/60 Hz L35 L35 kw 0.54 / 0.54 Power consumption P el 50/60 Hz L35 L50 kw 0.61 / 0.61 Operating temperature range -20 C...+60 C Setting range +20 C...+50 C Storage temperature range -40 C...+70 C Energy efficiency ratio (EER) 50 Hz L35 L35 to DIN EN 14511 3.05 Seasonal energy efficiency ratio (SEER) 50/60 Hz L35 L35 6.4 Refrigerant g R134a, 750 Permissible operating pressure (p. max.) bar 24 Air throughput of fans (unimpeded air flow), internal circuit/external circuit m³/h 700 / 895 Weight kg 30.5 Accessories Filter mats 3 pc(s). 3285.800 14 Metal filters 1 pc(s). 3285.810 14 Temperature sensor 1 pc(s). 3124.400 14 Door-operated switch 1 pc(s). 4127.010 Cat. 35, 755 12 Further technical information available on the Internet.

Wall-mounted cooling units Blue e+ Accessories for climate control Page 14 Therm software Cat. 35, page 474 RiDiag software Page 15 Benefits: Average 75% energy savings thanks to speed-regulated components and heat pipe technology Suitable for international use due to a unique multi-voltage capability Longer service life of the components inside the enclosure and the cooling unit due to component-friendly cooling Intuitive operation due to touch display and intelligent interfaces Temperature control: e+ controller (factory setting +35 C) Material: Sheet steel Colour: RAL 7035 Protection category IP to IEC 60529: Internal circuit IP 55 Supply includes: Assembly parts Fully wired ready for connection (plug-in terminal strip) Note: Please observe the mounting instructions. Approvals: Available on the Internet Performance diagrams: Available on the Internet H B T Output class 2000 6000 W Model No. Packs of 3186.930 3187.930 3188.940 3189.940 Page Total cooling output 50 Hz L35 L35 to DIN EN 14511 kw 2 2.6 4.2 5.8 Total cooling output 50/60 Hz L35 L35 kw 2 / 2 2.6 / 2.6 4.2 / 4.2 5.8 / 5.8 Total cooling output 50/60 Hz L35 L50 kw 1.29 / 1.29 1.82 / 1.82 3.02 / 3.02 4.2 / 4.2 Rated operating voltage V, ~, Hz 110-240, 1~, 50/60 110-240, 1~, 50/60 380-480, 3~, 50/60 380-480, 3~, 50/60 380-480, 3~, 50/60 380-480, 3~, 50/60 Width (B) mm 450 450 450 450 Height (H) mm 1600 1600 1600 1600 Depth (T) mm 294 294 393 393 Rated output kw 0.73 1.05 1.3 2.2 Power consumption P el 50/60 Hz L35 L35 kw 0.57 / 0.57 0.99 / 0.99 1.21 / 1.21 2.2 / 2.2 Power consumption P el 50/60 Hz L35 L50 kw 0.6 / 0.6 0.94 / 0.94 1.28 / 1.28 2.2 / 2.2 Operating temperature range -20 C...+60 C -20 C...+60 C -20 C...+60 C -20 C...+60 C Setting range +20 C...+50 C +20 C...+50 C +20 C...+50 C +20 C...+50 C Storage temperature range -40 C...+70 C -40 C...+70 C -40 C...+70 C -40 C...+70 C Energy efficiency ratio (EER) 50 Hz L35 L35 to DIN EN 14511 3.5 2.63 3.46 2.64 Seasonal energy efficiency ratio (SEER) 50/60 Hz L35 L35 8.1 6.2 8.1 6.2 Refrigerant g R134a, 1150 R134a, 1150 R134a, 1750 R134a, 1750 Air throughput of fans (unimpeded air flow), internal circuit/external circuit m³/h 1250 / 1250 1250 / 1250 2300 / 2300 2300 / 2300 Weight kg 55.2 55.2 72.4 72.4 Note on Model No. Full installation not possible Full installation not possible Accessories Filter mats 3 pc(s). 3285.900 3285.900 3285.900 3285.900 14 Metal filters 1 pc(s). 3285.910 3285.910 3285.910 3285.910 14 Temperature sensor 1 pc(s). 3124.400 3124.400 3124.400 3124.400 14 Door-operated switch 1 pc(s). 4127.010 4127.010 4127.010 4127.010 Cat. 35, 755 Further technical information available on the Internet. 13

Accessories for climate control Filter mats for cooling units, air/air heat exchangers and chillers Rittal cooling units are low-maintenance and are supplied without filter mats. Filter mats may be used for extreme conditions. Benefits: Temperature-resistant from -40 C...+80 C Material: Open-celled polyurethane foamed plastic To fit Model No. for cooling units for chillers W x H x D mm Packs of Model No. 3185.830 360 x 297 x 10 3 pc(s). 3285.800 3186.930/3187.930/ 3188.940/3189.940/ 3334.400 380 x 358 x 10 3 pc(s). 3285.900 Metal filters Particularly when cooling units are used in dusty and oily environments, it is advisable to use washable metal filters. If air or steam condenses on the metal surfaces, any particles present will adhere to the metal, and can easily be washed out with water or grease-dissolving detergents. Material: Aluminium To fit Model No. for cooling units for chillers W x H x D mm Packs of Model No. 3185.830 320 x 280 x 10 1 pc(s). 3285.810 3186.930/3187.930/ 3188.940/3189.940/ 3334.400 380 x 358 x 10 1 pc(s). 3285.910 Temperature sensor for Blue e+ cooling units, Blue e+ chillers NTC sensor to regulate Blue e+ cooling units according to an individual measurement point within the enclosure (control based on an external sensor), and according to the cold air outlet from the cooling unit inside the enclosure (control based on outlet temperature). For chillers: Differential control is used if it is necessary to regulate the temperature of the medium depending on the ambient temperature (positive or negative). For this, the temperature sensor needs to be positioned near the Blue e+ chiller. Supply includes: External sensor with connection cable (length 2.5 m) Packs of Model No. 1 pc(s). 3124.400 14 Further technical information available on the Internet.

Accessories for climate control RiDiag Software for the parameterisation, diagnosis and analysis of Rittal cooling units. For Design Blue e+ chillers Blue e+ cooling units RiDiag III Full, downloadable version in German and English. Product-specific scope of supply Release of additional functions with chargeable licence under Model No. 3159.300 Packs of 1 pc(s). Model No. 3159.300 IoT interface The IoT interface is used to link Rittal components such as Blue e+ cooling units, Blue e+ chillers, smart monitoring systems etc. to the customer's own monitoring and/or energy management systems. Data may be integrated both horizontally and vertically into data collectors and processors, to allow the long-term logging and evaluation of device data, statuses and system messages. Communication protocols: SNMPv1, SNMPv2c, SNMPv3, OPC-UA, Modbus/ TCP, CAN bus, Profinet Network protocols: Telnet, SSH, FTP, SFTP, HTTP, HTTPS, NTP, DHCP, DNS, SMTP, Syslog, LDAP, RADIUS Benefits: The IoT interface is middleware, whose interfaces allow a variety of devices and systems to communicate with one another. The data can then be forwarded into superordinate systems. Material: Plastic to UL 94-V0 Colour: RAL 7016 Anthracite grey Protection category IP to IEC 60529: IP 20 Supply includes: Connection cable (1 m) with RJ 45 connector Angle bracket for Blue e+ cooling unit Assembly instruction: The IoT interface can be secured on a 35 x 7.5 top hat rail to DIN EN 60 715 using a springloaded metal clip, or to the rear of a Blue e+ cooling unit using the angle bracket. W x H x D mm 18 x 117 x 120 For Operating temperature range Protocols Interfaces Blue e+ cooling units Blue e+ chillers Smart monitoring system CMC III sensors +0 C...+70 C SNMP OPC-UA Modbus/TCP CAN bus Profinet 1 x Micro USB type B (device) for USB 2.0 1 x Micro-SD memory card slot for SD 2.0 1 x USB 2.0 high-speed functions (EHCI) 1 x acknowledgement button 1 x 3-pole push-in spring connection terminal for NTC sensor 2 x RJ45 jack for RS 485 interface (climate control unit interface) Ethernet IPv4/IPv6 Network interface Ethernet to IEEE 802.3 via 10BASE-T, 100BASE-T and 1000BASE-T Type of electrical connection 3-pole push-in spring connection terminal (24 V DC) Packs of 1 pc(s). Model No. 3124.300 Further technical information available on the Internet. 15

Wall-mounted cooling units Blue e+ Technical details Wall-mounted cooling units Blue e+ SK 3186.930, SK 3187.930, SK 3188.940, SK 3189.940 Installation options SK 3186.930, SK 3187.930 Installation options SK 3188.940, SK 3189.940 External mounting Partial internal mounting Internal mounting External mounting Partial internal mounting 393 450 294 119 175 234 60 393 144 249 1600 Mounting cut-out External mounting, partial internal mounting, internal mounting for door, rear and side panel, W 600 mm Mounting cut-out External mounting rear and side panel, W = 500 mm 450 450 433 ±1 386 1600 1579 ±1 (10.5) 1600 125 112.5 1468 (12.5) 505 613 375 375 780.5 (1580.5) Ø 11 (4x) Important installation instructions for full internal mounting Not generally possible for 4.2 and 5.8 kw For 600 mm wide enclosure doors, please note: Move the cut-out towards the door hinge by 25 mm, and dismantle the tubular door frame Important installation instructions for external mounting on 500 mm deep enclosures Partial internal mounting and full internal mounting not supported External mounting only possible with mounting cut-out for 500 mm deep enclosures 16

Wall-mounted cooling units Blue e+ Technical details Wall-mounted cooling units Blue e+ SK 3185.830 Installation options SK 3185.830 External mounting Partial internal mounting Internal mounting Mounting cut-out External mounting, partial internal mounting, internal mounting 310 310 400 400 310 100 208 250 58 383 ±1 950 950 929 ±1 Overview of all Blue e+ information Design made easy Detailed climate control calculation with the Therm software Therm app enables rapid parameterisation www.rittal.com/therm Item information Product description and features Assembly instructions Approvals Interactive performance diagrams CAD drawings www.rittal.com/blue_e_plus_wallmount The Blue e+ microsite Calculate potential savings and amortisation periods with the efficiency calculator Full information on the energy label and the SEER Videos showing technical details: Heat pipe Multi-voltage support Intelligent interfaces and Blue e+ app Service messages may easily be sent with the Blue e+ app via an NFC interface and much more besides can be found at www.rittal.com/blue_e_plus 17

Wall-mounted cooling units Blue e+ Technical details TopTherm wall-mounted cooling units Blue e+ Output class 1600 W (110 240 V, 1 ~, 50 60 Hz / 380 480 V, 3 ~, 50 60 Hz) 1.6 kw SK 3185.830 4000 3500 3000 2500 P c 2000 1500 1000 500 0 20 25 30 35 40 45 50 55 60 T u Enclosure internal temperature Ti = 45 C Ti = 40 C Ti = 35 C Ti = 30 C Ti = 25 C Pc = Total cooling output [W] Tu = Ambient temperature [ C] Output class 2000/2600 W (110 240 V, 1 ~, 50 60 Hz / 380 480 V, 3 ~, 50 60 Hz) 2 kw SK 3186.930 4000 2.6 kw SK 3187.930 5000 3500 3000 2500 4500 4000 3500 3000 P c 2000 P c 2500 1500 2000 1500 1000 1000 500 500 0 20 25 30 35 40 45 50 55 60 0 20 25 30 35 40 45 50 55 60 T u T u Enclosure internal temperature Ti = 45 C Ti = 40 C Ti = 35 C Ti = 30 C Ti = 25 C Pc = Total cooling output [W] Tu = Ambient temperature [ C] Enclosure internal temperature Ti = 45 C Ti = 40 C Ti = 35 C Ti = 30 C Ti = 25 C Pc = Total cooling output [W] Tu = Ambient temperature [ C] 18

Wall-mounted cooling units Blue e+ Technical details Output category 4200/5800 W (380 480 V, 3 ~, 50 60 Hz) 4.2 kw SK 3188.940 7500 5.8 kw SK 3189.940 10000 6500 9000 8000 5500 7000 P c 4500 3500 P c 6000 5000 2500 1500 4000 3000 2000 500 20 25 30 35 40 45 50 55 60 1000 20 25 30 35 40 45 50 55 60 T u T u Enclosure internal temperature Ti = 45 C Ti = 40 C Ti = 35 C Ti = 30 C Ti = 25 C Pc = Total cooling output [W] Tu = Ambient temperature [ C] Enclosure internal temperature Ti = 45 C Ti = 40 C Ti = 35 C Ti = 30 C Ti = 25 C Pc = Total cooling output [W] Tu = Ambient temperature [ C] 19

Enclosures Power Distribution Climate Control IT Infrastructure Software & Services You can find the contact details of all Rittal companies throughout the world here. XWW00016EN1611 www.rittal.com/contact