Mar11 Rev E

Similar documents
For latest revision, visit our website at For Regional Customer Service, visit our website at

Connector, OPTIMATE*, FSMA 905 & 906, Fiber Optic

Jul03 Rev C EC

3M 8900 Single-mode SC Crimplok Connector

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

ETSI ES V1.1.1 ( )

Follow The Leader In Shielded Technology

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

TECHNICAL SPECIFICATION

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

DESIGN!!GUIDELINES!!!!!

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

Pivot Power RJ45 Modular Plug Connectors

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

SPECIFICATION. Spec No : VSS-1402-CS603B

Introducing Ultra Short LC : Fiber Optic Cable Assemblies

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

DETAIL SPECIFICATION SHEET CONNECTOR, FIBER OPTIC PLUG, CIRCULAR HERMAPHRODITIC, IN-LINE MOUNT, 2 AND 4 POSITIONS, EXPANDED BEAM

SC Connector. Fiber Optic Connectors. MDR Electronics

RCIT Cable Certification Testing Revised 10/2017

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

FREEDM Loose Tube Interlocking Armored Cables

SECTION 4 TABLE OF CONTENTS

Compact live fiber identifier with integrated optical power meter

ISO/IEC testing LC to LC (Duplex Multimode) DTX-MFM

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

PRO SERIES FIBRE-150M

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Interface Practices Subcommittee SCTE STANDARD SCTE Specification for Mainline Plug (Male) to Cable Interface

TENDER SUMMARY. Tender Title:

SOLO ADSS Short-Span Cables, Fibers

EZ-MATE CONNECTORS The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

SPECIFICATION. Optical Fiber Cable

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL RADIO FREQUENCY, (SERIES BNC (CABLED), PIN CONTACT, CLASS 2)

T-BERD /MTS-4000 Platform OLP-4057 PON Selective Power Meter Module

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE AND COMPONENTS. July 19, 2013

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Data Sheet HFBR-4531Z/4532Z/4533Z/4535Z. Crimpless Connectors for Plastic Optical Fiber and Versatile Link. Features. Description.

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Primex Wireless, Inc. July, Wells Street Lake Geneva, WI

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

TECHNICAL SPECIFICATION

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

User Guide. Centrex Recording Interface

Sidelighter TM Optical distance to fault measurement module

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, DUMMY STOWAGE, SERIES III, METRIC

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

Fiber Optic Meter Fiber Optic Source

SPECIAL SPECIFICATION 6559 Telecommunication Cable

3M No Polish Jacketed SC/APC Connector

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

SPECIAL SPECIFICATION 8540 Telecommunication Cable

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

High Density Optical Connector with Unibody Lensed Resin Ferrule

e-enterable Fiber Optic Splice Closure (Re-Enterable Aerial Closure for Access Service)

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Model GS Port Node 1 GHz with 65/86 MHz split

Optical Component Environmental Test System

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

SMART CLASSix 24/48 UTP Patch Panels -

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

3A+G Technology & Turnkey Production Solution XFS COMMUNICATIONS, INC.

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY (SERIES SMA (CABLED) - PLUG, PIN CONTACT, CLASS 2)

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE

DVI Rover 700 User Guide

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Keyed LC Connector Solution A LANscape Solutions Product

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

MTS/T-BERD Platforms WDMPMD Module

Prisma Optical Networks Ancillary Modules

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Mustang Series Fast Ethernet, TFOCA II, 100Base- TX / FX Media Converter, Multimode, 1310nM, USB Powered - 5.0VDC

Special Specification 6242 Special Fiber Optic Cable

25W 9xxnm Uncooled Multimode Laser Diode Module

DLE C-201. Actual Size

Transcription:

Product Specification 108-1832 11Mar11 Rev E MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. SCOPE 1.1. Content This specification, which meets the Optical Fiber Cabling Components Standard TIA/EIA-568-B.3, covers the performance, tests and quality requirements for TE Connectivity (TE) MT-RJ Jack, 39 mm, multimode fiber optic connectors in the following configurations: Standard, XG and MT-RJ SECURE. 1.2. Qualification When tests are performed on the subject product line, procedures specified in Figure 2 shall be used. All inspections shall be performed using the applicable inspection plan(s) and product drawing(s). 1.3. Qualification Test Results Successful qualification testing on the Standard product line was completed on 31Oct03. Qualification of the XG compatible jack was completed on 17Feb04, and the MT-RJ SECURE product line qualification was completed on 01Mar05. The Qualification Test Report number for this testing is 501-545. This documentation is on file at and available from Engineering Practices and Standards (EPS). 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the latest edition of the document applies. In the event of conflict between the requirements of this specification and the product drawing, the product drawing shall take precedence. In the event of conflict between the requirements of this specification and the referenced documents, this specification shall take precedence. 2.1. TE Documents! 102-952: Quality Specification (Qualification of Fiber Optic Connectors and Cable Assemblies)! 408-4555: Instruction Sheet (39 mm Patch Panel MT-RJ Jack Kits 1278303-[ ], 1278807-[ ], 1278808-[ ], and 1693951-[ ])! 408-8718: Instruction Sheet (MT-RJ Jack Kits 1278414-[ ], 1278415-[ ], 1278810-[ ], 1278811-[ ], 1588878-[ ], 1588879-[ ], 1588880-[ ], 1693949-[ ], and 1754252-[ ])! 501-545: Qualification Test Report (MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG)) 2.2. Commercial Standards! TIA/EIA-455-B: Standard Test Procedures for Fiber Optic Fibers, Cables, Transducers, Sensors, Connecting and Terminating Devices and Other Fiber Optic Components! TIA/EIA-526-14A: Optical Power Loss Measurement of Installed MM Cable Plant! TIA/EIA-568-B.3: Optical Fiber Cabling Components Standard! TIA/EIA-604-12: Fiber Optic Connector Intermateability Standard (FOCIS) - Type MT-RJ 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. Company All Rights Reserved Indicates change *Trademark For latest revision, visit our website at www.te.com/documents. 1 of 9 For Regional Customer Service, visit our website at www.te.com TE logo is a trademark. Other products, logos, and company names might be trademarks of their respective owners. LOC B

3. REQUIREMENTS 3.1. Design and Construction Product shall be of the design, construction and physical dimensions specified on the applicable product drawing(s). 3.2. Optical Power Source Primary wavelengths for optical power source(s) shall be 850 ± 30 nm and 1300 ± 30 nm unless otherwise stated in the Qualification Test Report. 3.3. Ratings Performance Value Units Attenuation, Typical (See Note) 0.36 db Return Loss, Typical (See Note) 35 db Storage Temperature 0 to 60 C Operating Temperature 0 to 60 C Cable Retention 2.2 [0.5] N [lbf] Durability 500 Cycles Flex Cycling 100 Cycles NOTE Typical values represent the median of the sample data. See Figure 3 for maximum values. Figure 1 3.4. Performance and Test Description Product is designed to meet the mechanical, environmental and optical transmittance performance requirements specified in Figure 2. Unless otherwise specified, all tests shall be performed at ambient environmental conditions. 3.5. Test Requirements and Procedures Summary Test Description Requirement Procedure Visual and mechanical inspection. Meets requirements of product drawing. Complies with dimensional requirements of FOCIS, TIA/EIA-604-12. See Note (a). Figure 2 (continued) TIA/EIA-455-13A. Visual, dimensional and functional per applicable quality inspection plan. Rev E 2 of 9

Test Description Requirement Procedure Attenuation (insertion loss). Return loss. Low temperature. specimen is 0.75 db. specimen is 20 db. specimen is 20 db Maximum change in attenuation for any single specimen is 0.3 db during test. Figure 2 (continued) 108-1832 TIA/EIA-455-171A, Method D1 except launch is part of pair under test and is not reference quality. Launch fiber/cable shall be wrapped in order to achieve Category 1 launch conditions according to TIA/EIA-526-14A. Wraps shall be close wound turns on a smooth surface and be secured in such a manner to guarantee integrity for the duration of the test. Use the following protocol for jack termination: Terminate the jack in accordance with Instruction Sheet 408-4555 or 408-8718 as appropriate. If the initial IL reading is 0.65 db or greater, then the field fiber should be removed, and reinserted. If the second reading is 0.65 db or greater the fiber should be cut off, prepared, and terminated per the specifications for fiber preparation in 408-4555 or 408-8718. EIA/TIA-455-107A, or TIA/EIA-455-8. An optical time domain reflectometer may be substituted for the coupler method. EIA/TIA-455-188. Subject mated specimens to 0 ± 3 C for 96 hours. Precondition specimens for 24 hours at 23 ± 5 C with 20 to 70% RH. Measure both attenuation and return loss before and Record optical transmittance after precondition and at 4 hour intervals during test. Take final attenuation and return loss readings after the specimens have returned to ambient conditions. See paragraph 5.2. Rev E 3 of 9

Test Description Requirement Procedure Humidity, steady state. Temperature life. Strength of coupling mechanism. specimen is 20 db Maximum change in attenuation for any single specimen is 0.4 db during test. specimen is 20 db specimen is 20 db Figure 2 (continurd) 108-1832 TIA/EIA-455-5C, Test Method A, Test Condition A. Subject mated specimens to steady state humidity at 90 to 95% RH and 40 ± 2 C for 96 hours. Measure initial optical transmittance at least 1 hour after preconditioning with specimens in place in the test chamber. Record optical transmittance once every 4 hours during test and calculate change. Measure final attenuation and return loss within 1 to 2 hours of the chamber s return to ambient conditions, with specimens in place in the test chamber. See paragraph 5.2. TIA/EIA-455-4C. Subject mated specimens to 60 ± 2 C for 96 hours. Precondition specimens for 2 hours at 23 C and 20 to 70% RH. Measure both attenuation and return loss before and after test with specimens undisturbed in the chamber at ambient conditions. See paragraph 5.2. EIA/TIA-455-185. Fixture module assembly of a mated specimen. Apply a 33 N [7.4 lbf] tensile load to the housing on the plug side of a mated specimen at a rate of 25.4 mm [1 in] per minute. Hold for a minimum of 5 seconds. Measure attenuation and return loss before and Rev E 4 of 9

Test Description Requirement Procedure Cable retention, 0 degrees. Cable retention, 90 degrees. Durability. Cable flexing. specimen is 20 db Maximum attenuation increase for any single specimen is 0.5 db after test. specimen is 20 db Maximum attenuation increase for any single specimen is 0.5 db after test. specimen is 20 db specimen is 20 db Figure 2 (continued) 108-1832 EIA/TIA-455-6B, Method 1, 0-degrees: Using a 7.5 cm [ 3 in] mandrel located 23 cm [ 9 in] from behind the back end of the module assembly, apply a 2.2 N [0.5 lbf] tensile load to each buffered or coated fiber. Apply load at a rate of 25.4 mm [1 in] per minute at 0 degree pull angle to the mated test specimen. Hold for 5 seconds. Measure attenuation and return loss before and EIA/TIA-455-6B, Method 1, 90-degrees: Repeat cable retention test with tensile load applied at a 90-degree pull angle. Use 2.2 N [0.5 lbf] tensile load for each buffered or coated fiber when testing the module assembly. EIA-455-21A. Mate and unmate plug-to-jack connection 500 times. Measure attenuation and return loss before and Clean the specimen every 25 cycles. Record attenuation every 50 cycles. Record final readings after the specimens have been inspected and cleaned. TIA/EIA-455-1B, Figure 2 apparatus. Using a 7.5 cm [3 in] mandrel, apply a 224 g [0.5 lbf] tensile load to buffered or coated fiber at a minimum distance of 20 cm [8 in] behind the end of the module assembly on the receive side of the mated specimen. Flex loaded side ± 90 degrees per cycle for 100 cycles at maximum rate of 15 cycles per minute. Measure attenuation and return loss before and after test with the load removed. Rev E 5 of 9

Twist. Impact. Test Description Requirement Procedure specimen is 20 db specimen is 20 db EIA-455-36A. Apply a 2.2 N [0.5 lbf] tensile load to buffered or coated fiber at a point 23 cm [9 in] from the back of the module assembly on the jack side of the mated specimen. Rotate the loaded side ± 2.5 revolutions per cycle for 10 cycles at a maximum rate of 30 cycles per minute. Measure attenuation and return loss before and after test with the load removed. TIA/EIA-455-2C, Method B. Unmate the jack connector from the plug and drop the module assembly end 8 times from a height of 1.8 m [70.9 in]. Randomize the module orientation for each drop. Record attenuation and return loss before and Clean the specimen before mating for final readings. After the completion of 8 impacts, each specimen should be opened, and re-terminated per the instructions for jack termination in 408-4555 or 408-8718 as appropriate. The re-termination shall include repositioning of the fiber only, recleaving of the fiber is not permitted. NOTE (a) (b) Dimensions not measured on actual test specimens are covered by First Article approval, which includes a review of product drawing(s) to verify conformance with dimensions specified in the FOCIS document, TIA/EIA-604-12. Shall meet visual requirements, show no physical damage and shall meet requirements of additional tests as specified in Test Sequence in Figure 4. Figure 2 (end) Attenuation and Return Loss Maximum allowed attenuation for any single specimen Minimum allowed return loss for any single specimen Multimode 0.75 db 20 db Figure 3 Rev E 6 of 9

3.6. Product Qualification Test Sequence Test Group (a) Test or Examination 1 2 3 4 5 6 7 Test Sequence (b) Visual and mechanical inspection 1 1 1 1 1 1 1 Attenuation (insertion loss) 2 2 2 2 2 2 2 Return loss 3 3 3 3 3 3 3 Low temperature 4 4 Humidity, steady state 5 5 Temperature life 6 6 Strength of coupling mechanism 4 4 Cable retention, 0 degrees 5 4 Cable retention, 90 degrees 6 5 Durability 7 6 Cable flexing 4 6 Twist 5 7 Impact 6 8 5 NOTE (a) (b) See paragraph 4.1.A. Numbers indicate sequence in which tests are performed. Figure 4 Rev E 7 of 9

4. QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specimen Selection Specimens shall be prepared according to normal manufacturing means and shall be selected at random from current production per Figure 5. Cable used for qualification shall be of type and length specified in Figure 5 and terminated on each end as required for equipment interfacing. Test Group 1 2 3 4 5 6 7 Fiber size: (µm/µm ) 50/125 62.5/125 50/125 50/125 50-125 Cable type (receive end) 900 µm Tight Buffer 900 µm Tight Buffer 250 µm Coated Fiber MT-RJ Plug Cable Assembly PN 1-1278128-0 1-1278032-0 1278128-3 250 µm Coated Fiber MT-RJ Jack Module Assembly PN 1588495-2 1588495-1 1-1374395-1 1-1374395-3 (XG) MT-RJ Connector Kit PN 6278750-1 900 µm Tight Buffer 1-1278873-0 1-1828264-0 (MT-RJ SECURE plug) 1588493-1 (red) 1588493-7 (brown) MT-RJ SECURE jack 1918356-1 (red) 1918356-7 (brown) MT-RJ SECURE plug Test specimens required 8 8 8 8 8 15 8 (see Note) Control cable required 1 0 0 1 0 0 0 NOTE Two colors were tested to represent the MT-RJ SECURE product line. The test group of 8 specimens consisted of 4 each from the part numbers shown. Figure 5 B. Cable Assembly Preparation Launch cables shall be prepared from specified cable assembly part numbers by cutting the cable assembly in half and attaching to the test equipment. Receive cables shall be factory prepared cable assemblies using specified cable part number and the applicable test interface connector. C. Test Sequence Qualification inspection shall be verified by testing specimens as specified in Figure 4. 4.2. Requalification Testing If changes significantly affecting form, fit or function are made to the product or manufacturing process, product assurance shall coordinate requalification testing, consisting of all or part of the original testing sequence as determined by development/product, quality and reliability engineering. 4.3. Acceptance Acceptance is based on verification that the product meets requirements of Figure 2. Failures attributed to equipment, test setup or operator deficiencies shall not disqualify the product. When product failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to confirm corrective action is required before resubmittal. Rev E 8 of 9

4.4. Quality Conformance Inspection The applicable quality inspection plan will specify the sampling acceptable quality level to be used. Dimensional and functional requirements shall be in accordance with the applicable product drawing and this specification. 5. SPECIAL INSTRUCTIONS 5.1. Cleaning If at any time, a specimen is uncoupled during qualification testing, the specimen shall be cleaned according to the applicable Instruction Sheet(s) prior to any subsequent optical measurements. Additional cleaning techniques deemed necessary by Product Engineering shall be described in the Qualification Test Report. If, after cleaning the specimen as prescribed, loss performance exceeds the specified limit, or, if the operator suspects the presence of debris at the optical interface, perform the cleaning procedure a second time. If the resultant optical reading still exceeds the specification, clean the specimen a third time and accept that reading. 5.2. Control Cables Control cables shall be subjected to climatic environmental tests. Transmittance shall be recorded each time a specimen transmittance is made. Changes in control cable power of less than 0.05 db may be neglected in the test specimen power and loss calculations. If control cable power changes by more than 0.05 db over the test or sequence of tests, change in control cable power shall be included in power and loss calculations per TIA/EIA-455-20A. Rev E 9 of 9