InfiniBand Trade Association

Similar documents
InfiniBand Trade Association

100G EDR and QSFP+ Cable Test Solutions

32 G/64 Gbaud Multi Channel PAM4 BERT

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

Tektronix Inc. DisplayPort Standard

Receiver Testing to Third Generation Standards. Jim Dunford, October 2011

InfiniBand Trade Association

M809256PA OIF-CEI CEI-56G Pre-Compliance Receiver Test Application

Serial ATA International Organization

Comparison of NRZ, PR-2, and PR-4 signaling. Qasim Chaudry Adam Healey Greg Sheets

Validation of VSR Module to Host link

Keysight Technologies N4917A Optical Receiver Stress Test Solution. Data Sheet Version 1.3 New: Extension to 8G Fibre Channel

Agilent N4965A Multi-Channel BERT 12.5 Gb/s Data Sheet

PCI Express. Francis Liu Project Manager Agilent Technologies. Nov 2012

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

A 90 Gb/s 2:1 Multiplexer with 1 Tap FFE in SiGe Technology

N4917BACA Optical Receiver Stress Test Solution 100 Gb/s Ethernet

N4917CPCA Optical Receiver Stress Test Solution

The Effect of Inserted ISI on Transition Density Plots and DCD & ISI Histograms of MJS Patterns

Agilent N6467A BroadR-Reach Compliance Test Application. Methods of Implementation

Proposed reference equalizer change in Clause 124 (TDECQ/SECQ. methodologies).

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Keysight N4965A Multi-Channel BERT 12.5 Gb/s. Data Sheet

Agilent N4876A 28 Gb/s Multiplexer 2:1

PAM4 signals for 400 Gbps: acquisition for measurement and signal processing

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

USB 3.1 ENGINEERING CHANGE NOTICE

The Challenges of Measuring PAM4 Signals

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Agilent N5431A XAUI Electrical Validation Application

Keysight Technologies N4917CPCA Optical Receiver Stress Test Solution for CPRI Fronthaul Networks. Preliminary Data Sheet

40G SWDM4 MSA Technical Specifications Optical Specifications

ASNT_PRBS20B_1 18Gbps PRBS7/15 Generator Featuring Jitter Insertion, Selectable Sync, and Output Amplitude Control

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

Keysight Technologies M8048A ISI Channels

SV1C Personalized SerDes Tester

Serial ATA International Organization

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Keysight N6467A/N6467B BroadR-Reach Compliance Test Application. Methods of Implementation

40G SWDM4 MSA Technical Specifications Optical Specifications

SHF Communication Technologies AG,

SDAIII-CompleteLinQ Multi-Lane Serial Data, Noise and Crosstalk Analysis

Ordering information. 40Gb/s QSFP+ ER4 Optical Transceiver Product Specification. Features

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

100Gb/s Single-lane SERDES Discussion. Phil Sun, Credo Semiconductor IEEE New Ethernet Applications Ad Hoc May 24, 2017

10mm x 10mm. 20m (24AWG) 15m (28AWG) 0.01μF TX_IN1 V CC[1:4] TX_OUT1 TX_OUT2 TX TX_IN3 TX_IN2 TX_OUT3 TX_OUT4 SERDES TX_IN4 RX_OUT1 RX_IN1 RX_OUT2

10GBASE-LRM Interoperability & Technical Feasibility Report

DisplayPort Standard. Agilent, Inc. Draft2 January 14, 2013

BER MEASUREMENT IN THE NOISY CHANNEL

100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

Agilent N4876A 28 Gb/s Multiplexer 2:1

Duobinary Transmission over ATCA Backplanes

BRR Tektronix BroadR-Reach Compliance Solution for Automotive Ethernet. Anshuman Bhat Product Manager

Keysight Method of Implementation (MOI) for VESA DisplayPort (DP) Standard Version 1.3 Cable-Connector Compliance Tests Using E5071C ENA Option TDR

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

Exceeding the Limits of Binary Data Transmission on Printed Circuit Boards by Multilevel Signaling

RF Signal Capture & Playback Simple Operation Guide

PBR-310C E-BERT. 10Gb/s BERT System with Eye Diagram Tracer

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

EVLA Fiber Selection Critical Design Review

QSFP SV-QSFP-40G-PSR4

Practical Receiver Equalization Tradeoffs Applicable to Next- Generation 28 Gb/s Links with db Loss Channels

Why Engineers Ignore Cable Loss

Electrical and Optical Clock Data Recovery Solutions up to 32 Gb/s

10 Gb/s Duobinary Signaling over Electrical Backplanes Experimental Results and Discussion

12G-SDI Physical Layer Analysis using the Ultra 4K Tool Box

WAVEEXPERT SERIES OSCILLOSCOPES WE 9000 NRO 9000 SDA 100G. The World s Fastest Oscilloscope

40GBd QSFP+ SR4 Transceiver

Rack-Mount Receiver Analyzer 101

New Serial Link Simulation Process, 6 Gbps SAS Case Study

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

Agilent Parallel Bit Error Ratio Tester. System Setup Examples

WAVEEXPERT 100H. Wide Bandwidth Oscilloscopes for the Next Generation Serial Data Standards

SV1C Personalized SerDes Tester. Data Sheet

Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

Brian Holden Kandou Bus, S.A. IEEE GE Study Group September 2, 2013 York, United Kingdom

Product Specification 56Gbps 60/100m QSFP+ Optical Transceiver Module FTL414QB2C APPLICATIONS

Agilent 86100C Infiniium DCA-J

Agilent E4887A HDMI TMDS Signal Generator Platform

Switching Solutions for Multi-Channel High Speed Serial Port Testing

Synthesized Clock Generator

QPHY-USB3 USB3.0 Serial Data Operator s Manual

Modula SDI Digital Video Enclosures

Systematic Tx Eye Mask Definition. John Petrilla, Avago Technologies March 2009

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

C65SPACE-HSSL Gbps multi-rate, multi-lane, SerDes macro IP. Description. Features

100G CWDM Link Model for DM DFB Lasers. John Petrilla: Avago Technologies May 2013

Loop Bandwidth Optimization and Jitter Measurement Techniques for Serial HDTV Systems

64G Fibre Channel strawman update. 6 th Dec 2016, rv1 Jonathan King, Finisar

Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

New Functions in Software Version 8

Measurements and Simulation Results in Support of IEEE 802.3bj Objective

Maps of OMA, TDP and mean power. Piers Dawe Mellanox Technologies

TelePresence Cisco TelePresence Synch with Edge95MXP - Troubleshooting

USB-TG124A Tracking Generator User Manual

DATA SHEET. Two (2) fibers Detachable HDMI 2.0 Extender,

Transcription:

InfiniBand Trade Association Revision 1.02 3/30/2014 IBTA Receiver MOI for FDR Devices For Anritsu MP1800A Signal Analyzer and Agilent 86100D with module 86108B and FlexDCA S/W for stressed signal calibration Anritsu MP1800A Signal Analyzer Agilent 86100D with module 86108B This material is provided for reference only. The InfiniBand Trade Association does not endorse the vendor s equipment outlined in this document. This document is provided "AS IS" and without any warranty of any kind, including, without limitation, any express or implied warranty of non-infringement, merchantability or fitness for a particular purpose. In no event shall IBTA or any member of IBTA be liable for any direct, indirect, special, exemplary, punitive, or consequential damages, including, without limitation, lost profits, even if advised of the possibility of such damages IBTA-FDR-Device-Rx-MOI-Anritsu-Agilent-v1 02 Page 1 of 7 3/30/2014

Contents Purpose... 4 Test Procedure... 4 A. Calibration of the stressed signal... 4 B. Selection of the linear cables... 6 Insertion Loss... 6 Crosstalk Noise... 6 C. Performing the test... 7 IBTA-FDR-Device-Rx-MOI-Anritsu-Agilent-v1 02 Page 2 of 7 3/30/2014

Table 1- Modification Record Revision Release Date Author Comments 1.00 2/18/2014 Alexander Rysin Initial version of the document 1.01 2/27/2014 Alexander Rysin Replaced the Agilent 86100D image to include the 86108B module Added the module calibration procedure for the oscilloscope 1.02 3/30/2014 Alexander Rysin Several corrections, following comments by James Morgante: Page 4, step 2: Phase-matched RF cables have to be used for connection between the BERT and the oscilloscope/tested device. Page 4, step 4: added Enable Tracking between P and N signals. Added numbering to the Test Procedure sections. IBTA-FDR-Device-Rx-MOI-Anritsu-Agilent-v1 02 Page 3 of 7 3/30/2014

Purpose Verify that the receiver under test meets the required bit error ratio when tested using stressed input signals. Test Procedure A. Calibration of the stressed signal 1) In case the 86100D oscilloscope is turned off and/or not calibrated, calibrate the 86100D oscilloscope and the 86108B module: a) Turn on the oscilloscope and let warm up for at least 30 minutes. b) On the oscilloscope calibrate the module by going to Tools > Calibrate, selecting all calibrations for the 86108B and following the prompts. 2) Connect the Data Output ports of the Anritsu signal analyzer PPG Module to the oscilloscope channel inputs by phase-matched RF cables. 3) Push the physical button with the number of the PPG module on the Anritsu MP1800A Mainframe. 4) Use the Output tab in the Anritsu MP1800A to set the bitrate (14.0625 Gb/s) and the data amplitude (400 mv single-ended). Enable Tracking between P and N signals. 5) In the Pattern tab in the Anritsu MP1800A select Data test pattern and use the data editor to transmit alternating bits (1010) pattern. 6) In the Output tab, push the Calibration button in the lower right corner. 7) Make sure that the Output indicator LED on the Anritsu MP1800A mainframe is on. If not, push on the Output physical button. 8) In the oscilloscope, select Setup Mode Oscilloscope. 9) Clock recovery procedure: a) Click on CDR (Clock recovery). b) Make sure Nominal Data Rate is set to the desired rate (for example 14.0625 Gb/s). c) Click on Relock if the button is red and says lock, then you are not in synch. 10) Push Pattern lock lower right software button. 11) Push Slot channel setup (lower left software button), select differential measurement and push D1A software button. 12) Push Run upper right software button. 13) Use the Amplitude Tab on the upper left and select Amplitude. 14) If necessary, adjust the Anritsu MP1800A PPG amplitude to achieve a reading of 800 mv on the oscilloscope amplitude measurement. 15) In the Pattern tab in the Anritsu MP1800A select PRBS test pattern and choose Length of 2^9-1. 16) Push the physical button with the number of the Jitter Modulation Source module on the Anritsu MP1800A Mainframe. 17) Set the Random Jitter (RJ) amplitude to 0.15 UI p-p. 18) Set the Sinusoidal Jitter (SJ) amplitude to 0.1 UI and the SJ frequency to 5 MHz. 19) On the oscilloscope, select Setup Mode Jitter. 20) Push Run to perform the measurement. 21) Verify that the measured RJ value is 0.107% UI (0.762 ps) RMS and the measured DCD value is 3.5 %UI (2.49 ps). 22) In case the measured DCD value differs from 3.5 %UI (2.49 ps): a) Push the physical button with the number of the PPG module on the Anritsu MP1800A Mainframe IBTA-FDR-Device-Rx-MOI-Anritsu-Agilent-v1 02 Page 4 of 7 3/30/2014

b) Disable Tracking. c) Change slightly the offsets of the Data and XData in opposite directions (i.e. 45% for Data and 55% for XData) until the desired value is reached. 23) In case the measured RJ value differs from 0.107% UI (0.762 ps) RMS, correct the RJ amplitude (in the Anritsu MP1800A Jitter Modulation Source module screen) until the desired value is reached. 24) Select Measure Configure Jitter Mode Measurements Advanced 25) In the Random Jitter/Interference (RJ/RN) section, go to the Stabilization tab, select Fix RJ at and push the Get Measured RJ button. Make sure that the measured RJ value is displayed in the text box, as it can be seen in Figure 1. Figure 1. Locking the RJ value for long pattern measurements 26) Select Setup Mode Eye/Mask 27) Use the Adv Eye tab on the left and select RJ. Check the Fix RJ option. 28) In the Pattern tab in the Anritsu MP1800A select PRBS test pattern and choose Length of 2^31-1. 29) Use the Adv Eye tab on the left and select TJ. 30) In case the measured TJ value differ from 28% UI (19.9 ps) RMS, correct the SJ amplitude (in the Anritsu MP1800A Jitter Modulation Source module screen) until the desired value is reached. IBTA-FDR-Device-Rx-MOI-Anritsu-Agilent-v1 02 Page 5 of 7 3/30/2014

B. Selection of the linear cables The linear cables are used in the RX tolerance testing in order to induce distortion in the form of intersymbol interference (ISI) and crosstalk noise on the propagating signals. The InfiniBand TM Architecture Specification Volume 2 defines two test channels a low loss channel, introducing moderate levels of insertion loss and therefore moderate levels of ISI, but high level of crosstalk noise and a maximal loss channel, introducing high levels of insertion loss and therefore high levels of ISI, but moderate level of crosstalk noise. Insertion Loss The minimal insertion loss levels of the cables, used for RX tolerance testing, are 15 db at 7.03 GHz for the high-loss cable, and 5.79 db at 7.03 GHz for the low-loss cable. Crosstalk Noise The minimal induced RMS crosstalk noise should be 10 mv, out of which 5.5 mv should be the far-end crosstalk noise, for the maximum loss cable and 6.4 mv, out of which 4.1 mv should be the far-end crosstalk noise, for the low loss cable. The following steps should be taken to verify these requirements: 1) Measure the near end and far end crosstalk noise of the selected cables, using a vector network analyzer (VNA). The frequency range of the measurements should be 10 MHz 15 GHz. 2) For each RX lane, create a CSV worksheet arranged in the following manner: a) The first column will contain the frequency points of the VNA measurements in GHz. b) Columns B-E will contain the measured near end crosstalk values, in db. c) Columns F-H will contain the measured far-end crosstalk values, in db. 3) Save the attached Matlab (Octave) script icn.m in the directory of the created CSV worksheets. icn.m 4) Open the saved Matlab (Octave) script icn.m. Adjust the following parameters: a) The filename of the CSV worksheet. b) Ant value should be set to the output amplitude of the tested device s transmitters in mv. c) Tnt value should be set to the rise time of the tested device s transmitters in ns. d) Tft value should be set to the rise time of the signal source for the aggressor lines (crosstalk generator) in ns. 5) Run the Matlab (Octave) script. Its outputs are the calibrated near end crosstalk (denoted as sigma_nx), the calibrated far end crosstalk (denoted as sigma_fx) and the calibrated ICN noise (denoted as sigma_x). 6) In case the sigma_fx and/or sigma_x are smaller than the minimal levels, defined by the specification, adjust the Aft value, until these levels are reached. IBTA-FDR-Device-Rx-MOI-Anritsu-Agilent-v1 02 Page 6 of 7 3/30/2014

C. Performing the test The setup for the FDR RX tolerance test with linear cables is illustrated in Figure 2. The Anritsu MP1800A PPG output is connected to the tested lane and the signal to the other 3 lanes of the tested port is supplied from another signal source, preferably with controllable output amplitude. In case the tested device has numerous ports, any other port of the tested device can be employed to supply the signal to the other 3 lanes of the tested port (for far end crosstalk generation). MCB TX TX Crosstalk Generator RX Port Under Test RX Figure 2. Test setup for FDR RX tolerance testing with linear cables. After connecting the test setup, the test flow will be as follows: 1. Configure the Anritsu MP1800A PPG output signal as described in section (A) of this document. 2. Configure the amplitude of the crosstalk generator outputs to the Aft value, found in section (B) of this document. 3. Configure the transmitters of the tested ports to transmit data in order to generate near end crosstalk noise. 4. Check the data, recovered by the tested receiver, for bit errors. This can be done either by employing an ondie bit error counter, or by configuring the tested device in loopback mode (driving the recovered data from a transmitter) and employing the Anritsu MP1800A error detector. 5. The tested receiver is considered compliant if no bit errors are recorded for 214 seconds (to achieve a BER of 10-12 with a confidence level of 95%. IBTA-FDR-Device-Rx-MOI-Anritsu-Agilent-v1 02 Page 7 of 7 3/30/2014