GESTRA Steam Systems NRR 2-50 NRR English. Installation & Operating Manual Level Controller NRR 2-50 Level Controller NRR 2-51

Similar documents
Level Measurement silometer FMC 420, FMC 423

Standard signal metering in wall-mounting case

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Process transmitter RMA422

Figure 1: Device components

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Datasheet - SRB301LC 24VAC/DC

Panel-Mounted Thermostat

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Gamma instabus. Technical product information

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Ordering details. Approval. Classification

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Heating thermostat Series AMHs B Operating Instructions 11.06/

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

Datasheet - SRB-E-201ST

Panel-mounting thermostats, type series EM

Capacitance Limit Detection nivotester FTC 420/421/422

SQM40/41 Actuators for air and gas dampers

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Electronic converter for level transmitters MT03L Instructions manual

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

02/11/2015

MT03A Electronic converter for flow rate transmitters

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

SAUTER flexotron RDT405 Manual

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Panel-mounting Thermostats EM Series


Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Process Transmitter RMA 422

EGM Einthoven Goldberger Module Type 701

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

Series CT7N Bimetallic Overload Relays

Actuators IC 20, IC 40

Single Point Flow Monitor SW118 SW119

MICROMASTER Encoder Module

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

CAMTO LTD. Arc detecting system DC/AC

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

DLP200M 2 Relay Module for Heating and Cooling Plants

OP5. Preprogrammed, configurable controller for simple applications

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

EB 3000 as of Version 1.7

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Dimming actuators GDA-4K KNX GDA-8K KNX

Safety Light Curtain C 4000

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

DCP100 Digital Control Programmer Specifications

Model Number Structure

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

Catalogue Ignitors and power switches for HID

+GF+ SIGNET 8860 Dual Channel Conductivity/Resistivity Controller

TUC: Universal thermostat

3 Cleaning. 4 Technical data

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

HS-509 VIBRATION TRIP MODULE

Operating Instructions Dimmer for V Incandescent Lamps

EG4015. Digital Generator Governor Controller User Manual

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

INSTALLATION & USER GUIDE

Registers type ILR7XX and ILR7XXT

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

LED MODULES READYLINE DL

DLP600M 6+1 Relay Module for Heating and Cooling Plants

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

Type: DILM12 10(24VDC) Article No.:

MS2540 Current Loop Receiver with RS485 Communication

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Capacitance Level Measurement Electronic insert FEC 12

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

Linear flow controls VFC Linear flow controls with actuator IFC

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

User Manual M1 - tricolour

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

4 Wiring Brochure Wiring and installation of specific control

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Product information. Front-door station series with video for surface-mount

Transcription:

GESTRA Steam Systems NRR 2-50 NRR 2-51 EN English Installation & Operating Manual 819180-03 Level Controller NRR 2-50 Level Controller NRR 2-51 1

Contents Important notes Page Intended use...4 Function...4 Safety information...5 Directives and standards VdTÜV Bulletin "Wasserstand 100" (Water Level 100)...5 LV (Low Voltage Directive) and EMC (Electromagnetic Compatibility)...5 ATEX (Atmosphère Explosible)...5 Notes on the Declaration of Conformity/Manufacturer's Declaration...5 Approval for Marine Use...5 Technical data NRS 2-50 / NRR 2-51...6 Contents of package...7 In the control cabinet: Installing the level controller Dimensions of the NRR 2-50 / NRR 2-51...8 Key...8 Installation in control cabinet...8 Name plate/identification...9 In the control cabinet: Electrically connecting the level controller Wiring diagram for level controller NRR 2-50...10 Key...10 Wiring diagram for level controller NRR 2-51...11 Key...11 Supply voltage connection...12 Connection of output contacts...12 Connecting the level electrode/level transmitter...12 Output of manipulated variable Y or connection of actual value output (optional)...12 Tools...12 In the system: Electrically connecting the level electrode/transmitter Connection of level electrode/level transmitter...13 Factory settings...13 2

Contents continued Changing factory settings Page Changing the function and input of the level electrode/transmitter...14 Operating the level controller Meaning of codes on the 7-segment display...16 Setting the measuring range...17 Additional information on control parameters...17 Commissioning Setting parameters...18 Setting the measuring range...19 Operation, alarm and testing Setting switchpoints and control parameters...20 Level controller NRR 2-50 Displays...21 Level controller NRR 2-51 Displays...21 Check function of MIN/MAX output contacts...22 Fault indications and troubleshooting Display, diagnosis and troubleshooting...23 Further information Action against high-frequency interference...24 Replacing/taking the equipment out of service...24 Disposal...24 3

Important notes Intended use The NRR 2-50 / NRR 2-51 level controller is used in combination with NRG 2.-.. level electrodes or the NRGT 26-1 level transmitter as a limit switch and water level controller, e.g. in steam and water boiler systems, or in condensate and feedwater tanks. The level controller indicates when a MIN and MAX water level has been reached, and opens or closes a control valve. The NRR 2-50 / NRR 2-51 level controller can be combined with the NRG 21-.. or NRG 26-21 level electrodes and the NRGT 26-1 level transmitter. Function The NRR 2-50 / NRR 2-51 level controller processes the level-dependent voltage signals from the NRG 2..-.. level electrodes or the level-dependent current signal from the NRGT 26-1 level transmitter. These input signals are standardised by the controller to 0 and 100 % of the boiler measuring range, and shown as an actual value on the 7-segment LED display. Level controller NRR 2-50: The level controller works with an electrically actuated control valve as a 3-position stepping controller with proportional-plus-integral control action (PI controller). If the actual value deviates from the setpoint, the electric actuator is triggered by two output contacts and two flashing LEDs indicate whether the control valve is opening or closing. The controller can be configured for fill or discharge control. A further output contact indicates when a MIN or MAX water level is reached (the desired function can be selected by a switch). After the de-energizing time has elapsed, the output contact switches over and the MIN or MAX LED lights up. Level controller NRR 2-51: The level controller works with an electro-pneumatically actuated control valve as a continuous controller with proportional-plus-integral control(pi controller). In the event of deviations from the setpoint, it outputs a current of 4-20 ma as manipulated variable Y. The controller can be configured for fill or discharge control. If the MIN or MAX water level is reached, after the de-energizing delay the MIN or MAX output contact switches over in the level controller, and the MIN or MAX LED lights up. Level controller NRR 2-50 / NRR 2-51: Faults in the level electrode, the level transmitter, the electrical connection or the settings are indicated as error codes on the 7-segment LED display. In the event of a malfunction, the MIN and MAX alarm is triggered. If faults occur only in the NRR 2-50 / NRR 2-51 level controller, the MIN and MAX alarm is triggered and the system is restarted. Parameters can be changed or the MIN/MAX alarm simulated by operating the rotary knob. For external level indication, the NRR 2-50 level controller is optionally available with a 4-20 ma actual value output. 4

Important notes continued Safety information The equipment may only be installed, electrically connected and commissioned by suitable persons with the relevant instruction/training. Maintenance and modification may only be performed by authorised staff who have undergone specific instruction/training. Danger The terminal strips of the equipment are live during operation! There is a risk of serious injury due to electric shock! Always cut off the power supply to the equipment before installing, removing or connecting terminal strips! Important The name plate specifies the features of the equipment. Do not commission or operate any item of equipment that does not have its own specific name plate. Directives and standards VdTÜV Bulletin "Wasserstand 100" (Water Level 100) The NRR 2-50 / NRR 2-51 level controller, in combination with the NRG 2.-.. level electrode and the NRGT 26-1 level transmitter, is type approved to the VdTÜV Bulletin "Water Level 100". The VdTÜV "Wasserstand (=Water Level) 100" describes the requirements for water level control and limiting equipment for boilers. LV (Low Voltage Directive) and EMC (Electromagnetic Compatibility) The equipment conforms to the requirements of the Low Voltage Directive 2014/35/EU and the EMC Directive 2014/30/EU. ATEX (Atmosphère Explosible) The equipment must not be used in potentially explosive atmospheres, in accordance with European Directive 2014/34/EU. Notes on the Declaration of Conformity/Manufacturer's Declaration For details on the conformity of our equipment with European Directives, please refer to our Declaration of Conformity or our Manufacturer's Declaration. The current Declaration of Conformity/Manufacturer's Declaration is available at www.gestra.com documents, or can be requested from us. Approval for Marine Use The NRR 2-5.. level controller in combination with the NRGT 26-1 level transmitter is approved for marine use. 5

Technical data NRS 2-50 / NRR 2-51 Supply voltage 24 VDC +/ 20% Fuse external 0.5 A (semi-delay) Power consumption 4 VA Connection of level electrode, level transmitter (selected by switch) 1 input for NRG 21-.. and NRG 26-21 level electrode, 3 poles and screen, or 1 analogue input 4-20 ma, e.g. for NRGT 26-1 level transmitter, 2 poles and screen. Supply voltage to level electrode 12 VDC Outputs: NRR 2-50: 2 floating changeover contacts, 8 A 250 V AC / 30 V DC cos ϕ = 1 (control valve open/closed). 1 floating changeover contact, 8 A 250 V AC / 30 V DC cos ϕ = 1. De-energizing delay 3 seconds (MIN/MAX alarm, can be switched) NRR 2-51: 2 floating changeover contacts, 8 A 250 V AC / 30 V DC cos ϕ = 1. De-energizing delay 3 seconds (MIN/MAX alarm) 1 analogue output 4-20 ma, max. load 500 ohms (manipulated variable Y). Inductive loads must have interference suppression (RC combination) as per the manufacturer's specification. NRR 2-50: 1 analogue output 4-20 ma, max. load 500 ohms, e.g. for an actual value display (optional). Displays and controls 1 rotary knob with integrated push-button for MIN/MAX alarm test and parameter setting, 1 4-digit 7-segment LED display, green 2 red LEDs for MIN/MAX alarm, 2 amber LEDs for control valve opening/closing (NRR2-50 only) 1 4-pole code switch for configuration. Housing Housing material, base: black polycarbonate; front: grey polycarbonate Conductor size: 1 x 4.0 mm 2 solid, per wire, or 1 x 2.5 mm 2 per lead with sleeve to DIN 46228, or 2 x 1.5 mm 2 per lead with sleeve to DIN 46228 (min. 0.1 mm) Terminal strips can be removed separately Housing attachment: Mounting clip on support rail TH 35, EN 60715 Electrical safety Degree of contamination 2 for installation in control cabinet with degree of protection IP 54, fully insulated Degree of protection Housing: IP 40 to EN 60529 Terminal strip: IP 20 to EN 60529 Weight approx. 0.2 kg 6

Technical data continued NRS 2-50 / NRR 2-51 continued Ambient temperature at moment of switch-on 0... 55 C in operation 10... 55 C Transport temperature 20... +80 C (<100 hours), only switch on after a defrosting period of 24 hours. Storage temperature 20... +70 C, only switch on after a defrosting period of 24 hours. Relative humidity max. 95%, no moisture condensation Approvals: TÜV Certificate Contents of package NRR 2-50 1 level controller NRR 2-50 1 installation & operating manual NRR 2-51 1 level controller NRR 2-51 1 installation & operating manual VdTÜV Bulletin "Wasserstand 100" (Water Level 100): Requirements for water level control and limiting equipment. Type approval no.: TÜV WR XX-425 (see name plate) 7

In the control cabinet: Installing the level controller Dimensions of the NRR 2-50 / NRR 2-51 46 120 15 1 74 4 3 Fig. 1 2 Key 1 Upper terminal strip 2 Lower terminal strip 3 Housing 4 Support rail TH 35, EN 60715 Installation in control cabinet The NRR 2-50 / NRR 2-51 level controller is clipped onto a type TH 35, EN 60715 support rail in the control cabinet. Fig. 1 4 8

In the control cabinet: Installing the level controller continued Name plate/identification Name plate NRR 2-50, top Name plate NRR 2-51, top Safety information Type designation Manufacturer Degree of protection External fuse for output contacts Ambient temperature Output contacts Name plate, bottom Actual value output (optional) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Manipulated variable Y Fuse, provided on site Power consumption Supply voltage M 0,5A 4VA + _ 24 V= +/- 20% _ OUT 4-20mA 500 Ω + IN 4-20mA TÜV.WR.xx-425 Mat-Nr.: 392867 1 3 +12V NRG 2..-.. +_ M 0,5A 4 VA + _ 24 V = +/- 20% _ OUT 4-20mA 500 Ω + IN 4-20mA TÜV.WR.xx-425 Mat-Nr.: 392753 1 3 +12V +_ NRG 2..-.. Connection of level electrode / level transmitter Approvals Disposal information Serial number Serial number Fig. 2 9

In the control cabinet: Electrically connecting the level controller Wiring diagram for level controller NRR 2-50 NRR 2-50 MIN/MAX MIN/MAX 9 0 9 0 0.5 A (semidelay) Fig. 3 0.5 A (semidelay) 8 8 5 a 5 6 a 7 5 Supply voltage connection 24 V DC with semi-delay fuse 0.5 A provided on site 6 Level electrode NRG 21-.. / NRG 26-21. Max. 3 NRS/NRR 2-5.. devices can be connected (connection in parallel) 7 Level transmitter NRGT 26-1, 4-20 ma, with earthing point. Max. 3 NRS/NRR 2-5.. devices can be connected (series connection) 8 Central earthing point (CEP) in control cabinet 9 Output contact for control valve actuation 0 MIN/MAX output contact, de-energizing delay 3 seconds a Actual value output 4-20 ma (optional) 10 Key

In the control cabinet: Electrically connecting the level controller continued Wiring diagram for level controller NRR 2-51 NRR 2-51 MIN MAX MIN MAX 9 0 9 0 0.5 A (semidelay) Fig. 4 0.5 A (semidelay) 8 8 5 a 5 a 7 6 Key 5 Supply voltage connection 24 V DC with semi-delay fuse 0.5 A provided on site 6 Level electrode NRG 21-.. / NRG 26-21. Max. 3 NRS/NRR 2-5.. devices can be connected (connection in parallel) 7 Level transmitter NRGT 26-1, 4-20 ma, with earthing point. Max. 3 NRS/NRR 2-5.. devices can be connected (series connection) 8 Central earthing point (CEP) in control cabinet 9 MIN output contact, de-energizing delay 3 seconds 0 MAX output contact, de-energizing delay 3 seconds a Output 4-20 ma, manipulated variable Y 11

In the control cabinet: Electrically connecting the level controller continued Supply voltage connection The equipment is supplied with 24 V DC and has an external semi-delay 0.5 A fuse. Please use a safety power supply unit with safe electrical isolation. This power supply unit must be electrically isolated from dangerous live voltages and meet the requirements for double or reinforced insulation in accordance with one of the following standards: DIN EN 50178, DIN EN 61010-1, DIN EN 60730-1 or DIN EN 60950. Connection of output contacts Wire the upper terminal strip 1 (terminals 16-23) according to the desired switching functions. Provide an external slow-blow 2.5 A fuse for the output contacts. When inductive loads are switched off, voltage spikes are produced that may have a major adverse effect on the operation of control and measuring systems. Connected inductive loads must therefore have interference suppression (RC combination) as per the manufacturer's specifications. Connecting the level electrode/level transmitter For connecting the equipment, please use a screened, multi-core control cable with a minimum conductor size of 0.5 mm 2, e.g. LiYCY 4 x 0.5 mm 2, maximum length 100 m. Max. 3 NRS/NRR 2-5.. switches/controllers can be connected to a level electrode or a level transmitter. Wire the terminal strip as shown in the wiring diagram. Fig. 3, 4 Connect the screen as shown in the wiring diagram. Route the connecting cable between items of equipment separately from power lines. Output of manipulated variable Y or connection of actual value output (optional) For connection, please use a screened, multi-core control cable with a minimum conductor size of 0.5 mm 2, e.g. LiYCY 2 x 0.5 mm 2, maximum length 100 m. Please note the load of max. 500 ohms (output of manipulated variable Y). Wire the terminal strip as shown in the wiring diagram. Fig. 3, 4 Connect the screen once only to the central earthing point (CEP) in the control cabinet. Route the connecting cable between items of equipment separately from power lines. Any item of equipment that you wish to connect to the terminals for the output of manipulated variable Y or actual value output 4-20 ma (optional) must be certified to have at least double or reinforced insulation to DIN EN 50178 or DIN 61010-1 or DIN EN 60730-1 or DIN EN 60950 between the current loop and live parts of the equipment that are not supplied with safety extra-low voltage (SELV). Important n Do not use unused terminals as support point terminals. Tools n Screwdriver size 3.5 x 100 mm, fully insulated to VDE 0680-1. 12

In the system: Electrically connecting the level electrode/transmitter Connection of level electrode/level transmitter The NRR 2-50 / NRR 2-51 level controller can be combined with the NRG 21-.. or NRG 26-21 level electrodes and the NRGT 26-1 level transmitter. For connecting the equipment, please use a screened, multi-core control cable with a minimum conductor size of 0.5 mm 2, e.g. LiYCY 4 x 0.5 mm 2, maximum length 100 m. Connect the screen as shown in the wiring diagram. Important n Please commission the equipment as described in the NRG 21-.., NRG 26-21 or NRGT 26-1 installation & operating manuals. n Route the connecting cable between items of equipment separately from power lines. n The level transmitter must be connected to its own dedicated power supply. Factory settings Level controller NRR 2-50 n De-energizing delay: 3 sec. (factory set) n Voltage input for the connection of an NRG 21-.. or NRG 26-21 level electrode. n MAX switchpoint AL.Hi = 80 % n MIN switchpoint AL.Lo = 20 % n Setpoint SP = 50 % n Proportional band Pb = 20 % of setpoint n Integral action time ti = 0 % n Dead band = +/ 5 % of setpoint n Valve travel time tt = 40 s n Calibration value CAL.P = 100 % n Fill control function n MIN/MAX output contact set as MAX alarm Level controller NRR 2-51 n De-energizing delay: 3 sec. (factory set) n Voltage input for the connection of an NRG 21-.. or NRG 26-21 level electrode. n MAX switchpoint AL.Hi = 80 % n MIN switchpoint AL.Lo = 20 % n Setpoint SP = 50 % n Proportional band Pb = 20 % of setpoint n Integral action time ti = 0 % n Dead band = +/ 5 % of setpoint n Calibration value CAL.P = 100 % n Fill control function Code switch c : S1,S2,S3, S4 OFF Code switch c: S1,S2,S3, S4 OFF 13

Changing factory settings Danger The upper terminal strip of the equipment is live during operation. There is a risk of serious injury due to electric shock! Always cut off the power supply to the equipment before installing, removing or connecting the terminal strip! Changing the function and input of the level electrode/transmitter The input and function are determined by the setting of code switch c. To make changes, you can access the code switch as follows: s Switch off the supply voltage. n Remove the lower terminal strip. Fig. 5 n Insert a screwdriver between the terminal strip and the front frame, to the right and left of the arrow markings. n Release the terminal strip on the right and left sides, by turning the screwdriver in the direction of the arrow. n Remove the terminal strip. c Fig. 5 When your changes are complete: n Refit the lower terminal strip. n Switch the supply voltage back on. The equipment restarts 14

Changing factory settings continued Changing the function and input of the level electrode/transmitter continued If you wish to change the input or the function, set code switch c S1 to S3 in accordance with the table Fig. 6. Code switch c Toggle switch, white Level controller NRR 2-50 S 1 S 2 S 3 Output contact set for MAX alarm Output contact set for MIN alarm Level controller NRR 2-50 / NRR 2-51 Input for connection of level electrode NRG 21-.. or NRG 26-21 OFF ON OFF Input for connection of level transmitter NRGT 26-1 * ON Fill control OFF Discharge control ON Fig. 6 grey = factory setting Important * When connecting the NRGT 26-1 level transmitter, please set the upper and lower ends of the measuring range only in the transmitter. Here, please pay attention to the NRGT 26-1 installation & operating manual. Do not change the code switch c settings of S4! 15

Operating the level controller Meaning of codes on the 7-segment display Amber LED Valve opens Valve closes Fig. 7 OO75 7-segment display Rotary knob with integrated push-button OO75 MAX LED red MIN LED red Code Meaning Indicated when rotary knob is turned clockwise: AL.Hi Alarm High MAX switchpoint AL.Lo Alarm Low MIN switchpoint SP Setpoint Setpoint Pb Proportional band adjustable between 0 and 100 % adjustable between 0 and 100 % ti Time integral Integral action time, adjustable between 0 and 100 seconds tt Motor travel time Valve travel time (NRR 2-50 only), adjustable between 10 and 600 seconds test Test Tests output relays CAL.L Calibrate Low Only if level electrode Sets lower end of measuring range CAL.P Calibrate % NRG 21-.. or NRG 26- adjustable between 25 and 100% CAL.H Calibrate High 21 is connected Sets upper end of measuring range C Indicated in parameterization mode quit Confirm Input is not confirmed done Done Input is confirmed Indicated if malfunctions occur E.005 Error Faulty level electrode/transmitter, measuring voltage/current too low E.006 Error Faulty level electrode/transmitter, measuring voltage/current too high E.012 Error Lower and upper ends of measuring range changed around E.013 Error MIN switchpoint higher than MAX switchpoint 16

Operating the level controller continued Setting the measuring range A Lower end of measuring range, adjustable B Upper end of measuring range, adjustable C Measuring range [mm] = xxx % D Inactive range E Maximum installed length at 238 C D B 37 NRG 2.-.. NRGT 26-1 Set the lower and upper ends of the measuring range for your fill level measurement. The result is the measuring range C. Please calculate this measuring range in percent. A D C 26 E Important When connecting the NRGT 26-1 level transmitter, please set the upper and lower end of the measuring range only in the transmitter. Additional information on control parameters Proportional band Pb Parameter Control deviation Control valve Larger Large remaining deviation Responds slowly Smaller Example Small remaining deviation Responds quickly and may continually open/ close Measuring range 100% = 200 mm of sightglass Setpoint SP = 80 % of measuring range = 160 mm Proportional band Pb = +/- 20% of setpoint = +/- 16% = +/- 32 mm If the measuring range is 100% (200 mm) and the setpoint is 80% (160 mm), the proportional range will be +/- 16% (+/- 32 mm) or in the range of 128 to 192 mm. Integral action time ti Larger Slow correction of deviations Responds slowly Smaller Fast correction of deviations, control loop may tend to overshoot Responds quickly 17

Commissioning Setting parameters Amber LED Valve opens Valve closes Fig. 7 OO75 7-segment display Rotary knob with integrated push-button OO75 MAX LED red MIN LED red Start Action Display Function Switch on supply voltage. Water level between MIN and MAX. 7-segment display shows software and equipment version 7-segment display shows actual value System test, takes approx. 3 sec. System switches to operating mode Setting parameters Action 7-segment display Function Turn rotary knob until desired parameter is shown Press and hold the push-button (on rotary knob) Turn rotary knob Briefly press push-button When your entries are complete: press and hold the push-button within 3 sec. If you do not confirm your entry within 3 sec. or you do not make any further entries: Display toggles between parameter and saved value. First digit (0000) flashes. A new value is displayed. 2nd, 3rd or 4th digit flashes. (from right to left) done is displayed. Next, the display toggles between the parameter and the new value. quit is briefly displayed. After this, the display toggles between the parameter and the old value. Selecting the parameter Turn the rotary knob until the next parameter is shown. Or turn the rotary knob until the actual value is displayed. Or after 30s, the actual value is displayed automatically. Parameterization mode active. You can change the first digit. Turning clockwise increases the value, turning anti-clockwise reduces the value. 2nd, 3rd or 4th digit can now be changed using the rotary knob. Turning clockwise increases the value, turning anti-clockwise reduces the value. Input is confirmed. System switches back to the parameter. If you do not confirm, your entries will not be applied. Please repeat the procedure. If you do not confirm, the system switches back to the parameter. 18

Commissioning continued Setting the measuring range Level electrode NRG 2.-.. only : Setting the measuring range, option 1 Action Display Function Select parameter CAL.L. Press push-button. Press button again within 3 sec. (press and hold) Select parameter CAL.H and press push-button. Press push-button. Press button again within 3 sec. (press and hold) Reduce water level until start of measuring range A. After a short time, a hexadecimal number flashes. The current hexadecimal number flashes. done is displayed. After this, CAL.L and the hexadecimal alternate on the display. After a short time, 0000 % appears. Fill tank until top end of measuring range B. After a short time, a hexadecimal number flashes. The current hexadecimal number flashes. done is displayed. After this, CAL.H and the hexadecimal alternate on the display. After a short time, 0100 % appears. Calibrate start of measuring range. Input is confirmed. (actual value output = 4 ma) Calibrate top end of measuring range. Input is confirmed. (actual value output = 20 ma) Level electrode NRG 2.-.. only : Setting the measuring range, option 2 Action Display Function Reduce water level until start of measuring range A. Select parameter CAL.L. Press push-button. Press button again within 3 sec. (press and hold) Select parameter CAL.H. Press push-button. Press button again within 3 sec. (press and hold) After a short time, a hexadecimal number flashes. The current hexadecimal number flashes. done is displayed. After this, CAL.L and the hexadecimal alternate on the display. After a short time, 0000 % appears. Fill tank up to at least 25% of the measuring range. After a short time, a hexadecimal number flashes. The current hexadecimal number flashes. done is displayed. After this, CAL.H and the hexadecimal alternate on the display. After a short time, 0100 % appears. Select parameter CAL.P and set and save a percentage, e.g. 25%. Calibrate start of measuring range. Input is confirmed. (actual value output = 4 ma) Calibrate at a percentage of the measuring range, e.g. 25%. Input is confirmed. (actual value output = 20 ma) CAL.P interpolates the value measured at CAL.H to find 100% of the measuring range. CAL.P can be adjusted between 25 and 100%. Note n Adjusting the measuring range: The advantage of option 2 is that the tank only has to be partially filled. 19

Operation, alarm and testing Setting switchpoints and control parameters Amber LED Valve opens Valve closes Fig. 7 OO75 7-segment display Rotary knob with integrated push-button OO75 MAX LED red MIN LED red Setting the MIN/MAX switchpoints Select parameter AL.Lo, enter and save the desired percentage. MIN switchpoint setting between 0-100 % Select parameter AL.Hi, enter and save the desired percentage. MAX switchpoint setting between 0-100 % Select parameter SP, enter and save the desired percentage. Setting the setpoint Setpoint setting between 0-100 % Please take the settings for MIN/MAX switchpoints into consideration. Setting the proportional band Select parameter Pb, enter and save the desired Proportional band setting between 0-100 % percentage. Setting the integral action time Select parameter ti, enter and save the desired Integral action time settings between 0-100 s. percentage. Setting the valve travel time (NRR 2-50 only) Select parameter tt, enter and save the desired Integral action time settings between 10-600 s. percentage. Note n The NRR 2-50 level controller is only equipped with one output contact for limit indications. Therefore, please define its function (MAX or MIN alarm) using the code switch c. Fig. 5, 6. n The actual value is shown on the 7-segment display. 20

Operation, alarm and testing continued Level controller NRR 2-50 Displays Operation Action Display Function Actual value = setpoint Valve and MIN/ MAX LEDs do not light up Valve output contact 16/17/19 open. MIN output contacts 16/18 open, 17/18 closed. MAX output contacts 21/23 open, 22/23 closed. Value above or below setpoint. Value above or below setpoint Control valve opens, valve output contact Valve OPEN LED flashes amber 16/19 closed. or Valve OPEN CLOSED flashes amber Control valve opens, valve output contact 17/19 closed. Switchpoint for MAX water level reached or exceeded. Switchpoint for MIN water level reached or exceeded. MAX alarm MAX LED flashes red MAX LED lights up red or MIN alarm MIN LED flashes red MIN LED lights up red De-energizing delay in progress. De-energizing delay elapsed, output contacts 21/23 closed, 22/23 open. De-energizing delay in progress. De-energizing delay elapsed, output contacts 21/23 closed, 22/23 open. Level controller NRR 2-51 Displays Operation Action Display Function Actual value = setpoint MIN and MAX LEDs do not light up MIN output contacts 16/18 open, 17/18 closed. MAX output contacts 21/23 open, 22/23 closed. Switchpoint for MIN water level reached or exceeded. MIN alarm MIN LED flashes red MIN LED lights up red De-energizing delay in progress. Delay time elapsed, MIN output contacts 16/18 closed, 17/18 open. Switchpoint for MAX water level reached or exceeded. MAX alarm MAX LED flashes red MAX LED lights up red De-energizing delay in progress. Delay time elapsed, MAX output contacts 21/23 closed, 22/23 open. 21

Operation, alarm and testing continued Check function of MIN/MAX output contacts Test of MIN alarm and MAX alarm Action Display Function MAX LED flashes red De-energizing delay in progress. In operating mode: Water level between MIN and MAX Select parameter test. Press and hold push-button. Test complete, release pushbutton. Device switches to operating mode. MAX LED lights up red for 3 seconds The MIN and MAX LED do not light up for 1 second MIN LED flashes red MIN LED lights up red for 3 seconds MAX output contact 21/23 closed, 22/23 open. MIN output contact 16/18 open, 17/18 open. MAX output contact 21/23 open, 22/23 closed. De-energizing delay in progress. MIN output contact 16/18 closed, 17/18 open. Note: If you continue holding the push-button, the test sequence will start again. You can interrupt the test sequence at any time by releasing the push-button. Turn the rotary knob until the actual value is displayed. Or after 30s, the actual value is displayed automatically. Note The actual value is shown on the 7-segment display. 22

Fault indications and troubleshooting Display, diagnosis and troubleshooting Important Please check the following before fault diagnosis: Supply voltage: Is the level switch supplied with the voltage specified on the name plate? Wiring: Does the wiring conform to the wiring diagram? Faults indicated by the 7-segment display Fault code Fault Remedy E.005 E.006 E.012 E.013 Faulty level electrode, measuring voltage < 0.5 VDC Faulty level transmitter, measuring current < 4 ma Faulty level electrode, measuring voltage > 7 VDC Faulty level transmitter, measuring current > 20 ma Lower and upper ends of measuring range changed around MIN switchpoint higher than MAX switchpoint Check level electrode and replace if necessary. Check electrical connection. Check level transmitter and replace if necessary. Check electrical connection. Check level electrode and replace if necessary. Check electrical connection. Check level transmitter and replace if necessary. Check electrical connection. Reset measuring range Reset switchpoints In the event of a malfunction, the MIN and MAX alarm is triggered. Important n For further diagnosis, please refer to the NRG 21-.. NRG 26-21 and NRS 26-1 installation & operating manual. Note In the event of a level controller malfunction, the MIN and MAX alarm is triggered and the equipment restarts. If the process is continually repeated, the equipment must be replaced. 23

Further information Action against high-frequency interference High-frequency interference can be caused by out-of-phase switching operations. If such interference occurs and results in sporadic failure, we recommend taking the following action to suppress interference: n Provide inductive loads with RC combinations as per manufacturer's specifications. n Route the connecting cable to the level electrode or level transmitter separately from power lines. n Increase the distance from sources of interference. n Check the connection of the screen to the central earthing point (CEP) in the control cabinet. n Suppress HF interference using hinged-shell ferrite rings. Replacing/taking the equipment out of service n Switch off the power supply and cut off power to the equipment. n Remove the upper and lower terminal strips. Fig. 8 n Insert a screwdriver between the terminal strip and the front frame, to the right and left of the arrow markings. n Release the terminal strip on the right and left sides, by turning the screwdriver in the direction of the arrow. n Remove the terminal strips. n Release the white sliding fixture at the bottom of the housing and take the device off the support rail Fig. 8 Disposal The equipment must be disposed of in accordance with statutory waste disposal provisions. In the event of faults that cannot be remedied with the aid of this manual, please contact our Technical Customer Service. 24

For your notes 25

For your notes 26

For your notes 27

You can find our authorised agents around the world at: www.gestra.com GESTRA AG Münchener Straße 77 28215 Bremen Germany Telefon +49 421 3503-0 Telefax +49 421 3503-393 E-mail info@de.gestra.com Web www.gestra.de 819180-03/03-2017cm (808863-03) GESTRA AG Bremen Printed in Germany