White Paper. Timing for cran Fronthaul LTE

Similar documents
UG0682 User Guide. Pattern Generator. February 2018

UG0651 User Guide. Scaler. February2018

Paper review on Mobile Fronthaul Networks

Mobile networks: Transport Impacts

Fronthaul Challenges & Opportunities

Two-Level Fronthual Architecture and Requirements. Liuyan Han and Jinri Huang China Mobile

Two-Level Fronthual Architecture and Requirements. Liuyan Han and Jinri Huang China Mobile

Fronthaul solutions

OPTICAL TECHNIQUES FOR FRONTHAUL NETWORKS. 1. Introduction

Critical C-RAN Technologies Speaker: Lin Wang

XRAN-FH.WP.0-v01.00 White Paper

C-RAN architecture and fronthaul challenges Philippe Chanclou, Anna Pizzinat, Yann Denis Orange Labs Networks Sebastien Randazzo Orange DTRS/DIRM RAN

5G C-RAN Architecture: A Comparison of Multiple Optical Fronthaul Networks

Creating an ecosystem for vrans supporting non-ideal fronthaul

Precision Time Protocol - PTP (IEEE 1588 v2) OSA PTP Products. slide 1

Total Ionizing Dose Test Report. No. 14T-RTSX32SU-CQ256-D1RH41

Mobile Fronthaul optical transport for C-RAN architectures. Ingrid Nordmark VP R&D Transmode

Datasheet. Carrier Backhaul Radio. Model: AF-2X, AF-3X, AF-5X. Up to 687 Mbps Real Throughput, Up to 200+ km Range

Access technologies integration to meet the requirements of 5G networks and beyond

Submission Title: Requirements on Wireless Backhauling and Fronthauling

DragonWave, Horizon and Avenue are registered trademarks of DragonWave Inc DragonWave Inc. All rights reserved

1588/PTP Recovered Clock Wander Measurement Using PTP Slave Emulation to Estimate Clock Stability and Accuracy

FLEXWAVE PRISM DIGITAL DISTRIBUTED ANTENNA SYSTEM

Timing Needs in Cable Networks. Yair Neugeboren Director System Architecture, CTO Group, Network and Cloud, ARRIS WSTS 2017

FullMAX Air Inetrface Parameters for Upper 700 MHz A Block v1.0

InterReach Fusion Data Sheet

Datasheet. Full-Duplex, Point-to-Point Gigabit Radio. Models: AF-24, AF-24HD, AF-5, AF-5U. High Performance Wireless Backhaul

Clarke and Inverse ClarkeTransformations Hardware Implementation. User Guide

CHP Max Headend Optics Platform CHP CORWave II

IT S ABOUT (PRECISION) TIME

Hands-On Real Time HD and 3D IPTV Encoding and Distribution over RF and Optical Fiber

Innovations in PON Cost Reduction

Datasheet. Full-Duplex, Point-to-Point Gigabit Radio. Tel: +44 (0) Fax: +44 (0)

ITU-T Y.4552/Y.2078 (02/2016) Application support models of the Internet of things

Synchronization Issues During Encoder / Decoder Tests

Datasheet. Licensed Backhaul Radio. Models: AF-11FX-L, AF-11FX-H. Full-Duplex, Point-to-Point Radio. 11 GHz Frequency Operation

Datasheet. 5 GHz Carrier Radio with LTU Technology. Model: AF 5XHD. Up to 1+ Gbps Real Throughput, Up to 100 km Range

1588/PTP Recovered Clock Wander Measurement Using PTP Slave Emulation to Estimate Clock Stability and Accuracy

MOTOROLA CANOPY APPLICATION NOTE: REMOTE ACCESS POINT. Issue 1

Datasheet. 5 GHz Carrier Radio with LTU Technology. Model: AF 5XHD. Up to 1+ Gbps Real Throughput, Up to 100 km Range

PRODUCT BROCHURE. Gemini Matrix Intercom System. Mentor RG + MasterMind Sync and Test Pulse Generator

Datasheet. Carrier Class Point-to-Point Gigabit Radio. Models: AF24, AF5, AF5U. High Performance Wireless Backhaul. Extreme, Long-Range Links

Self Restoring Logic (SRL) Cell Targets Space Application Designs

ITU-T Y Functional framework and capabilities of the Internet of things

FRONTHAUL is a new network segment that appears in

5G New Radio Technology and Performance. Amitava Ghosh Nokia Bell Labs July 20 th, 2017

REGIONAL NETWORKS FOR BROADBAND CABLE TELEVISION OPERATIONS

Convergence of Broadcast and Mobile Broadband. By Zahedeh Farshad December 12-13, 2017

Primary Reference Clocks (PRC/SSU)

Therefore, HDCVI is an optimal solution for megapixel high definition application, featuring non-latent long-distance transmission at lower cost.

ITU-T Y Reference architecture for Internet of things network capability exposure

P1: OTA/XYZ P2: ABC c01 JWBK457-Richardson March 22, :45 Printer Name: Yet to Come

Ethernet over Coax EOC110K EOC110R. Instruction Manual. Ethernet over Coax Adapter Kit. Ethernet over Coax Receiver

Datasheet Densité IPG-3901

PRODUCT BROCHURE. Broadcast Solutions. Gemini Matrix Intercom System. Mentor RG + MasterMind Sync and Test Pulse Generator

Introduction. Fiber Optics, technology update, applications, planning considerations

Alcatel-Lucent 5620 Service Aware Manager. Unified management of IP/MPLS and Carrier Ethernet networks and the services they deliver

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

New Products and Features on Display at the 2012 IBC Show

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio

Co-location of PMP 450 and PMP 100 systems in the 900 MHz band and migration recommendations

Datasheet. Powerful 2x2 MIMO airmax BaseStation. Models: M5, RM5-Ti, M3, M365, M2, RM2-Ti, M900. Advanced Software Technology to Maximize Performance

Datasheet. Powerful 2x2 MIMO airmax BaseStation. Models: M5, RM5-Ti, M3, M365, M2, RM2-Ti, M900. Advanced Software Technology to Maximize Performance

Verizon New England Inc. Application for a Compliance Order Certificate for Rhode Island Service Areas 1 and 4. Exhibit 3

Integra series. Integra series comparison, v1.43, November All data are subject to change without prior notice Page 1

2.1 Introduction. [ Team LiB ] [ Team LiB ] 1 of 1 4/16/12 11:10 AM

RF RETURN OPTIONS AN ENABLENCE ARTICLE WRITTEN BY JIM FARMER, CTO. September,

RFO RF VIDEO EXTENDER REACH FARTHER, SPEND LESS EXTEND YOUR RF OVERLAY COVERAGE WITH A LOW COST SOLUTION

RTG4 Radiation Update J.J. Wang, Chief Engineer Nadia Rezzak, Staff Engineer Stephen Varela, Engineer

CABLE S FIBER OUTLOOK SURVEY REPORT

DVR or NVR? Video Recording For Multi-Site Systems Explained DVR OR NVR? 1

GatesAir Service Support

Content. Solutions. DLB series. LigoDLB PRO. LigoDLB ac. LigoPTP series. LigoPTMP. NFT series. Enterprise 2. Operators 2. Industrial 3.

Applications. NCO Clock Generator 1. Fine freq. adjustment. Synthesizer 0. Fine freq. adjustment. Synthesizer 1 Fs= Bs 1. *Ks 1. *16*Ms 1.

Images for life. Nexxis for video integration in the operating room

SECTION SYNCHRONIZATION

Broadband Multiplexers (Hi-TV)

Application Note. Serial Line Coding Converters AN-CM-264

PROMAX NEWSLETTER Nº 25. Ready to unveil it?

The long term future of UHF spectrum

LandRake HYC V 4006-MIMO Series 4GHz PTP / NATO Mobile Mesh Series

RF Technology for 5G mmwave Radios

VNP 100 application note: At home Production Workflow, REMI

Easy Breezy Indoor Connectivity. Cellular Without Boundaries. In-Building Coverage Solution Brief

F5 Network Security for IoT

TEPZZ 889A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2017/35

Microbolometer based infrared cameras PYROVIEW with Fast Ethernet interface

TIME-COMPENSATED REMOTE PRODUCTION OVER IP

Cloud Radio Access Networks

Microwave Backhaul Solutions SUPER HIGH PERFORMANCE ANTENNAS. Not just a new backhaul solution a whole new backhaul strategy

White Paper. Video-over-IP: Network Performance Analysis

PRACTICAL PERFORMANCE MEASUREMENTS OF LTE BROADCAST (EMBMS) FOR TV APPLICATIONS

DELL: POWERFUL FLEXIBILITY FOR THE IOT EDGE

Comparing JTAG, SPI, and I2C

There is little wonder

DOCSIS 3.1 Development and its Influence on Business

Challenges of Launching DOCSIS 3.0 services. (Choice s experience) Installation and configuration

Today s Speaker. SMPTE Standards Update: 3G SDI Standards. Copyright 2013 SMPTE. All rights reserved. 1

ITU-T Y Specific requirements and capabilities of the Internet of things for big data

Development trends in delivery of Live and VOD based services

Transcription:

White Paper Timing for cran Fronthaul LTE

Timing for cran Fronthaul LTE Traditional 4G mobile networks have adopted a decentralized RAN architecture with baseband units (BBUs) physically co-located with remote radio units (RRUs) inside a base station (BS). The baseband processing includes physical (PHY) layer, media access (MAC) layer, and parts of the network layer processing performed inside the BS. Mobile operators have begun to evolve their networks to prepare for 5G densification in major metro markets. Part of this evolution includes the migration from traditional mobile backhaul architectures to the concept of mobile fronthaul architectures. One of the major differences between backhaul and fronthaul is that fronthaul introduces the concept of segregating the baseband unit and radio head technologies in a cell site deployment. In mobile backhaul applications the cell sites include both the baseband unit and the radio head in the same location. These two technology functions communicate between them using a long-standing protocol called Common Public Radio Interface (CPRI). In mobile backhaul applications, this communication is executed over a short fiber optic cable of no more than a few meters. 5G has introduced a decentralized/distributed approach, called Cloud RAN (cran), which consists of centralizing the RAN functionalities in a broadband unit (BBU) pool location where the digital processing is performed. The remote radio head (RRH), which hosts the radio frequency (RF) transmit and receive components, performs analogue processing. In the cran architecture, the RRHs are connected to the BBU pool through high bandwidth transport links known as fronthaul. In mobile fronthaul applications, the BBUs are pooled together in locations called cran hubs. These cran hub locations still use CPRI to communicate between the BBU and the RRH, but the distance of the fiber optic connection between the BBU and the RRH is a much greater distance up to 17 km. The following two illustrations show the mobile backhaul and fronthaul architectures. Figure 1 Mobile Backhaul for LTE Timing Architecture Note: A grandmaster (GM) clock is a PTP server and an ordinary clock (OC) is a PTP slave/client. Microsemi Proprietary and Confidential White Paper Revision A 1

Figure 2 Mobile Fronthaul Architecture The current mobile backhaul architectures in place today have alternative solutions for meeting the timing requirements (frequency, time, and phase) documented in the industry standards. These requirements are evolving to support the evolution from LTE to LTE-TDD and LTE-Advanced technologies. The following two tables describe the LTE timing requirements defined by the industry standards organizations. Table 1 Why is Synchronization Required? Application Why You Need to Comply Impact of Non-Compliance LTE-FDD Call initiation Call interference Dropped calls LTE-TDD Time slot alignment Packet loss/collisions Spectral inefficiency LTE-A MBSFN LTE-A MIMO /COMP Proper time alignment of video signal decoding from multiple base stations Coordination of signals to/from multiple base stations Video broadcast interruption Poor signal quality at edge of cells LBS accuracy LTE-A eicic Interference coordination Spectral inefficiency Service degradation Investment in small cells and LTE networks is made to increase capacity and coverage. When synchronization fails, both objectives are lost. The resulting impact is felt by customers! Microsemi Proprietary and Confidential White Paper Revision A 2

Table 2 LTE Timing Specifications Application Frequency Network/Air Phase Note GSM, UMTS, WCDMA, LTE- FDD 16 ppb/50 ppb -- -- CDMA2000 16 ppb/50 ppb ±3 μs to ±10 μs -- LTE-TDD 16 ppb/50 ppb ±1.5 μs <3 km cell radius ±5 μs >3 km cell radius LTE MBMS (LTE-FDD and LTE-TDD) 16 ppb/50 ppb ±5 μs Inter-cell time difference LTE-Advanced 16 ppb/50 ppb ±10 μs In discussion by members of the 3GPP Note: 5G phase alignment requirements for RRHs is to be decided. The current proposal is 260 nanoseconds (±130 nanoseconds). The timing requirements for LTE RAN applications is served by multiple technologies and in some cases timing solutions used for the primary timing reference are backed up by timing solutions used as the secondary timing reference. The following three solutions are currently deployed to meet the existing and evolving timing requirements in the RAN. Embedded GNSS receiver technology in the cell site baseband units. This provides for all three timing components (frequency, time, and phase) and support for location services in markets that require this support, such as e911. Precision Time Protocol (PTP), also referred to as IEEE 1588, that delivers timing using a time stamping mechanism over the transport and/or access network at layer 3 or layer 2. PTP introduces the concept of a grandmaster clock (GMC) and PTP slave or client that exchange time stamps to transfer time/phase and reconstruct frequency at the slave location, such as an enodeb. PTP has two standards-based models used for deployment depending on the capabilities of the network elements support for PTP flows. PTP can be used as a primary or secondary timing reference. Synchronous Ethernet (SyncE) is a physical layer frequency distribution technology that can be used to distribute frequency in a chain of transport network elements in the same model used by SONET /SDH line timing applications. The drawback of SyncE is that it does not support time/phase transfer, only frequency. There are several approaches to solving the timing requirements when using fronthaul- and CPRI-based timing mechanisms. Technical and business cases can be made for the various alternatives, but one of the most important considerations is a solution that can be positioned for both the short term and the long term that factors in the evolution aspects related to 5G densification. The alternatives and associated technical and cost considerations are listed as follows. Microsemi Proprietary and Confidential White Paper Revision A 3

GNSS L1 distribution using splitters to connect the antennas to the GNSS receiver inputs of the BBUs. The associated cabling can be expensive, and the disruption of the GNSS reception will result in the oscillators in the BBUs to revert their internal accuracy, limited holdover capability to maintain primary reference time clock (PRTC) 100-nanosecond to UTC accuracy, and drift apart at different rates and in either direction compared to the GNSS reference. The following illustration shows an example of GNSS L1 distribution. Figure 3 Example GNSS Splitter Distribution Microsemi Proprietary and Confidential White Paper Revision A 4

GNSS receivers with a 1PPS output is daisy chained to BBUs to phase align the BBUs. This approach is fairly cost effective, but has a single point of failure issue, as a cable interruption can cause many of the clustered BBUs to revert to the internal oscillators in the BBUs with the same concerns as the previous approach. The following illustration shows an example of 1PPS distribution. Figure 4 CRAN CPRI Timing Use Case 1PPS (Single Point of Failure) Microsemi Proprietary and Confidential White Paper Revision A 5

Redundant GMCs connected to a GNSS reference that provide PTP flows thorough the LAN switch used to interconnect BBU traffic to PTP slaves in the BBU. This concept, in addition to being cost effective, provides the same accuracy level, 100 nanoseconds to Universal Coordinated Time (UTC), that a GNSS antenna achieves. This level of accuracy allows for Observed Time Difference of Arrival (OTDOA) support for e911 applications if needed. The LAN configurations for cran hubs should be redundant with two switches such that deploying two GMCs addresses single point of failure issues. The following illustration shows an example of GMC PTP distribution. Figure 5 CRAN CPRI TIming Use Case (GMC Redundant) A technically-sound GMC solution requires at least one of the following attributes: Holdover using a Rubidium oscillator. A Rubidium oscillator will drift off from PRTC quality at a much slower rate than the internal oscillators of the BBUs if the GNSS reference is disrupted. All BBU oscillators following the GMC in holdover will be drifting from the PRTC accuracy at the same rate and in the same direction. A PTP input to the GMC from an adjacent facility using asymmetry compensation algorithms that can maintain time and phase if the PTP input is disrupted. PTP time transfer from an adjacent location introduces the concept of an area timing hub, which can be utilized as a backup location to several cran hub location GMCs. It is recommended that area timing hubs use a Cesium Standard Reference, in addition to GNSS, for protection in the use case of a wide area GNSS outage. In this use case, all cran hubs will follow the Cesium Reference and maintain phase alignment until the GNSS reference is restored. The following illustration shows an example of an area timing hub. Microsemi Proprietary and Confidential White Paper Revision A 6

Figure 6 cran CPRI Timing Use Case (Area Timing Hub) Looking to The Future: The Evolution to ecpri, NGFI, and vran As the mobile Telecom industry moves to 5G densification in major metro markets, the standards bodies and RAN vendors are busy preparing for the future. The high bandwidth and fiber requirements for the transport of CPRI are limiting the fronthaul deployments for many operators that do not have their own fiber assets. Traditional CPRI-based cran architecture uses dedicated fiber, which makes centralization an expensive solution because it involves a large number of fiber cores that are expensive to deploy. The transport of CPRI over the OTN, using DWDM, is one way some operators are scaling their CPRI deployments and in many cases these OTN assets are leased facilities. There has been much debate over how to open the CPRI fronthaul market to all mobile players. The concepts of CPRI over Ethernet (ecpri) and replacing the TDM-like CPRI format with Ethernet messaging both hold the promise of reducing the bandwidth requirements of CPRI transport and making fronthaul affordable and available to all mobile operators. Ethernet is a very cost-effective transport technology that is widely deployed in the backhaul transport network. However, it is also an asynchronous besteffort technology that has not been originally designed to meet the low latency, jitter, and synchronization requirements of baseband signal transmission. These concepts fall under the Next Generation Fronthaul Interface (NGFI) umbrella, and it will be interesting to see if the industry moves to standardize on one format or adopt both methods. NGFI is the new fronthaul packet-based interface being studied by IEEE 1914.1 in order to provide a better bandwidth efficiency and achieve a more scalable transport networks. CPRI cannot scale with the bandwidth requirements of 5G. With CPRI, the operations above the LTE stack PHY level are performed by the radio equipment controller (REC), which is also in charge of the radio signal generation. The radio equipment (RE) is responsible for the sampling of the radio signal in the uplink direction. In the downlink direction, it just reconstructs the signal before transmitting on the air interface. The RE performs minimal digital processing, making it possible to centralize most of the digital processing functions in the REC. CPRI defines a very strict synchronization requirement between the RE and the REC for time and frame alignment. The RE must be traceable to the REC clock with an accuracy of 8.138 ns. CPRI implements a bit synchronous mechanism, where new frames are transmitted every Tc= 260.416 ns. CPRI requires a clock jitter of 2 ppb (parts per billion, 4% of the total inaccuracy) and a round-trip timing accuracy of ±16 ns. Microsemi Proprietary and Confidential White Paper Revision A 7

Both NGFI concepts would have an impact on the timing carried from a cran hub to the remote radio heads. As they are both Ethernet-based, not CPRI TDM, the timing will be impacted by introducing variable delays and asymmetry that was not present with CPRI over dedicated finer or the OTN. CPRI scales with carrier bandwidth and the number of antenna elements, which limits 5G features such as a massive number of antenna elements. The main approach that is being studied to remove the bandwidth requirement of CPRI fronthaul is to use various functional split options between the remote unit (RU) and the centralized unit (CU) whereby more or less base functionalities will be centralized depending on the split option. For example, a MAC-PHY split provides a substantial bandwidth reduction compared to traditional CPRI. In an NGFI architecture implemented with a so-called ideal fronthaul, some functional split options will maintain most of the digital signal processing functions in the BBU. In this case, the fronthaul transport needs to satisfy the synchronization requirements of 5G RAN features such as Massive MIMO, Carrier Aggregation (CA), and Joint Processing (JT). The functional split depends mainly on the availability of an ideal and non-ideal transport network. In a non-ideal fronthaul transport case, the functional split needs to occur at a higher level in the LTE protocol stack, which reduces the level of centralization that can be achieved in the cran hub. In this case, the synchronization and bandwidth requirements can be relaxed at the expense of some of these 5G RAN features. The following two technical solutions could be implemented in the future to help overcome these obstacles. White Rabbit (WR) technology a combination of physical layer and PTP timing. White Rabbit introduces the technique of measuring and compensation for asymmetry to mitigate time and phase transfer error. Partial timing support compatible with the ITU standard G.8275.2 where the position of a GMC is moved close to the PTP slaves in the remote radio heads. This is an excellent alternative to full onpath support White Rabbit for those operators who are not willing or cannot upgrade their networks for White Rabbit physical layer support. The following two illustrations highlight the White Rabbit full on-path support physical layer approach and the G.8275.2 partial on-path support approach. Figure 7 NGFI Timing and Sync White Rabbit Full On-Path Support Microsemi Proprietary and Confidential White Paper Revision A 8

Figure 8 NGFI Timing and Sync G.8275.2 Partial On-Path Support Summary Mobile architectures are evolving to support 5G densification in major metro markets. Mobile fronthaul and NGFI will be adopted and deployed. This will drive the evolution of CPRI, new standards and architectures for timing. Timing will be a critical part of the infrastructure and the deployment of GMCs in cran HUBS will be not only a good business investment but also a sound technical investment. The attributes of a GMC, such as no single point of failure, holdover, PTP backup with asymmetry compensation, and the capability of repurposing this technology as CPRI evolves to OTN and Ethernet use cases, makes PTP and the deployment of GMCs the best and logical choice as the timing technology for cran and future vran mobile architectures. Jim Olsen Solutions Architect Microsemi FTD Jim.Olsen@Microsemi.com Microsemi Proprietary and Confidential White Paper Revision A 9

Microsemi Corporate Headquarters One Enterprise, Aliso Viejo, CA 92656 USA Within the USA: +1 (800) 713-4113 Outside the USA: +1 (949) 380-6100 Fax: +1 (949) 215-4996 Email: sales.support@microsemi.com www.microsemi.com 2017 Microsemi Corporation. All rights reserved. Microsemi and the Microsemi logo are trademarks of Microsemi Corporation. All other trademarks and service marks are the property of their respective owners. Microsemi makes no warranty, representation, or guarantee regarding the information contained herein or the suitability of its products and services for any particular purpose, nor does Microsemi assume any liability whatsoever arising out of the application or use of any product or circuit. The products sold hereunder and any other products sold by Microsemi have been subject to limited testing and should not be used in conjunction with mission-critical equipment or applications. Any performance specifications are believed to be reliable but are not verified, and Buyer must conduct and complete all performance and other testing of the products, alone and together with, or installed in, any end-products. Buyer shall not rely on any data and performance specifications or parameters provided by Microsemi. It is the Buyer's responsibility to independently determine suitability of any products and to test and verify the same. The information provided by Microsemi hereunder is provided "as is, where is" and with all faults, and the entire risk associated with such information is entirely with the Buyer. Microsemi does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other IP rights, whether with regard to such information itself or anything described by such information. Information provided in this document is proprietary to Microsemi, and Microsemi reserves the right to make any changes to the information in this document or to any products and services at any time without notice. Microsemi Corporation (Nasdaq: MSCC) offers a comprehensive portfolio of semiconductor and system solutions for aerospace & defense, communications, data center and industrial markets. Products include high-performance and radiation-hardened analog mixed-signal integrated circuits, FPGAs, SoCs and ASICs; power management products; timing and synchronization devices and precise time solutions, setting the world's standard for time; voice processing devices; RF solutions; discrete components; enterprise storage and communication solutions; security technologies and scalable anti-tamper products; Ethernet solutions; Power-over-Ethernet ICs and midspans; as well as custom design capabilities and services. Microsemi is headquartered in Aliso Viejo, California, and has approximately 4,800 employees globally. Learn more at www.microsemi.com. 900-00786-000 Microsemi Proprietary and Confidential White Paper Revision A 10