The set is very simple. It consists of one small box, a small stool, and a small ping- pong table.

Similar documents
"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

"The Road Is Just A Surface" by Anja Garbarek and Jo Strømgren Kompani Technical Requirements

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Technical Rider "THEATRE" by SUPERAMAS

FASO DANCE COMPANY KALAKUTA REPUBLIK

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Rider Attached is a technical Rider covering schedule, technical and practical requirements, and contacts. Changes may occur.

TECHNICAL RIDER. If you have problems to fulfil some of our demands, please don t hesitate to contact us. We will find a solution!

CHELSEA THEATRE. Technical Specifications

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Rider. GöteborgsOperans Danskompani. Tour to xxx. Alaska. Table of Contents: 2. Stage. 3. Lighting. 4. Sound. 5. Medical. 6.

Borderline. Company Wang Ramirez TECHNICAL RIDER

SHIVER. Technical rider update : 10th feb Premiere at Theater l Arsenic in Lausanne/Suisse the 4th of february 2014

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Specification

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,

TECHNICAL REQUIREMENTS

TECHNICAL RIDER FOR GROUND FREIGHT-TOURING

[technical list] updated 27/09/2017. Groupe Emile Dubois My Ladies Rock Creation September Playing time : 1h15 without intermission

Technical specifications - Compagnie José Besprosvany Prométhée enchaîné

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Faris Family Studio at the Dance Centre, Vancouver BC 677 Davie Street, Vancouver, British Columbia. V6B 2G6

DEREHAM MEMORIAL HALL

JAMIE ADKINS. Circus INgognitus. Technical Rider Version: January, 2014

Everyness. Wang Ramirez Company TECHNICAL RIDER

JERWOOD VANBRUGH THEATRE

TECHNICAL RIDER March 30th 2015

Technical Rider. GöteborgsOperans Danskompani. Spirit Tour to XX DATE to DATE. Table of Contents: 1. The Company

Barney Simon Theatre Technical Specifications

Borderline. Company Wang Ramirez TECHNICAL RIDER

Technical Rider. Update: may 6th 2008

TECH SHEET AND INFORMATION (Updated )

Matt Dann Cultural Centre

Technical specifications Main theatre. Sound

PRELIMINARY TECHNICAL RIDER - LITTLE RED RIVER

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

New Theatre Royal Lincoln Technical Information

2017 TECHNICAL SPECIFICATIONS

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Technical Specification Pavilion Dance

Technical Specifications

ISLAND HALL TECHNICAL INFORMATION

Technical Rider. GöteborgsOperans Danskompani. Untitled Black. Tour to.. Table of Contents: 2. Stage. 3. Lighting. 4. Sound. 5. Medical. 6.

Avant Garde Dance & The Place Fagin s Twist Tech Spec 2016

Main House Technical Specification

CONTACT FOR TECHNICAL DETAILS AND QUESTIONS

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

Monolake Live Surround 2011/2012

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

CENTRE FOR PERFORMING ARTS

Technical Specification

Enormous Room Technical Rider & General Lighting Plan

Auditorium: 16m x 24m (including stage area) Variable acoustics to suit different performance types

The Haymarket Basingstoke Technical Specifications

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

The Mannie Manim Technical Specifications

Main Stage Technical Specs - Hall #2

THE STREET THEATRE. Technical Specifications

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Information

HUECO / Technical Rider

Lighthouse Theatre Technical Specification

LA BALLE ROUGE & QUATUOR

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Technical Specifications Updated 01/10/2017. Stage

Technical Specifications. Taylor Little Theater

Technical Specification (Studio Theatre)

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

HALFWAY TO DAWN TOUR

TECHNICAL SPECIFICATIONS

Technical Data Sheet

Sandusky State Theatre Technical Specifications

VENUE TECHNICAL REQUIREMENTS

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Main House Technical Specifications

Technical Specification

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

ROSE THEATRE BASEMENT

Rider Part1: Technical Requirements, A Cappella Show

Access to back stage is off Fletcher St on the eastern side of the building

Technical Specification (Studio Theatre)

SADNESS EXTENDED TECHNICAL RIDER

Figurines by Lola Maury - touring technical rider

Technical Pack. Attenborough Arts Centre

Latrobe Performing Arts Centre

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Studio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston

Technical Specification for the Alley Theatre, Strabane

SOMETIME BETWEEN NOW AND WHEN

Technical Services and Specification

HIRE AND TECHNICAL INFORMATION

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Dugdale Centre Technical Specification

Theatre Technical Specifications

Transcription:

A Dance Tribute to Ping Pong Choreography: Jo Strømgren Music: Charles Aznavour, Dean Martin, Nino Nardini, Clara Rockmore & Nadia Reisenberg, Metro- Tytöt, Zarah Leander, Jussi Björling & Nils Grevillius, Johann Strauss, Jacob Gade, Frederic Chopin, Lars Årdal, Jo Strømgren Voiceover: Tomáš Měcháček Light design: Lars Årdal, Audun Melbye Dancers: 1 st cast - Nataša Novotná, Milan Odstrčil, Alexandr Volný a Vojtěch Rak 2 nd cast - Šárka Bočková, Milan Odstrčil, Adam Sojka a Alexandr Volný Length: 55 min. Czech Premiere: 30.10.2015, Jatka78, Prague Technical requirements 1) The stage The performing area is ideally 10m wide x 8m deep. Absolute minimum is 8m wide and 8m deep, but must have at least 1m wide legs in addition, and wing space. The lighting bars or grid must be minimum 4,5m above the stage. The floor must be black dance floor, which must be very flat, taped and clean when we arrive. We need a black curtain at the back, a crossover behind is needed, and also 3 or more black wings, legs or curtains on each side. The masking should just be arranged to suit the venue, the positions on the lighting plan are only a suggestion. Borders to mask the lighting bars are nice if possible. The set is very simple. It consists of one small box, a small stool, and a small ping- pong table. Technical baggage: Case Measurements: Length 78 cm, width 58 cm, height 41,5 cm Weight: 26 kg. Content: Props, puppet 2) Staff needed If possible, the lighting and sound equipment should be pre- rigged. If the get- in is on the day of the first performance, we will need to begin work at 09.00, and require at least two technicians for rigging lighting, one stage technician for the masking, and one sound technician who knows the theatre sound system. There should be staff to clean the floor before the performance. We prefer to get out immediately after the final performance and this normally takes around one hour. For the get- out we need just one

technician. Derigging the venue's lighting, masking and sound equipment is the responsibility of the venue. 420PEOPLE crew: artists: 4 performers (3 males, 1 female) technicians: 1 light technician, 1 sound technician 3) Lighting Please see the lighting plan. The lighting equipment needed is: Minimum 36 dmx dimmer channels 18 x 1kW or 750W. zoom profiles (must have very clean lenses, and four perfectly working shutters, these should have a beam angle of 35 degrees or more) 5 x 1kW Fresnels or PC's (could well be profiles if you have enough). Must have barndoors. 5 x Parcans CP61 1000W 10 x Parcans CP62 1000W 8 x floorstands for Parcans. 1 x direct power supply, and DMX connection at the centre back for the smoke machine, which the venue should provide. Smoke detectors must be disabled for any rehearsals and the performance. 9 x dimmer channels on the floor. There must be a ladder, genie lift or other means of getting up to the lights for focussing. Minimum grid/ lighting bar height is 4,5m. We bring all colour filters required. All lighting instruments must have working barndoors or shutters. All profile lenses must be clean and have 4 working shutters. The 18 profiles are very important for the show. Please let us know as soon as possible if you have any problem with this. The venue should provide a DMX controlled smoke machine for the show. The smoke machine we often use is amartin Magnum 1200. Must be fully DMX controlled. It must be possible to disable smoke detectors for the performance. We bring our lighting console GrandMA2 on PC and need to connect this to the theatre DMX (standard 5 pin DMX). We require one LCD monitor for our MA2 on PC (VGA or HDMI connector). Important! DMX must be on one single universe because of our lighting console. Please contact us as soon as possible if you see a problem with this, if the theatre dimming system is not DMX controlled or if you foresee any other problem with lighting control.

The sound and light are operated from the same place at the centre back of the auditorium. If they are not in the same place, we will require some form of communication between the two positions. 4) Sound On stage: We require 3 loudspeakers on stands, all of the same make and model, placed at the back of the stage (upstage) in an LCR configuration, all on separate lines from the mixer. If possible, the Left and Right speakers of this LCR setup should be crossed over and supported by subwoofers, providing a full range sound system on stage. (This is highly preferred, but not a requirement) These loudspeakers and stands should be black, and the 3 LCR loudspeakers should be of identical make/ model. These loudspeakers are used for the majority of the sound content in this show, and MUST PLAY LOUD. Public Address: We require a high quality PA system providing even coverage of the audience. Minimum 100dB(A) undistorted, and a linear frequency response of 40Hz - 18kHz or better. All loudspeakers (stage monitors included) must be of very high quality; Meyer, Nexo, JBL or L- Acoustics preferred (never Electrovoice or Peavy, and not made of plastic!) The PA system should be set up as a full range stereo setup integrating its sub woofers. If the subs are on separate channels, additional mixer outputs will be required. Front of House: We require a high quality mixing desk. Minimum 10 inputs and 5 outputs, all controlled separately. Digital mixers are preferred, as we time- align the PA to the stage monitors. In the case of an analogue mixer, we would appreciate a stereo delay processor for the PA. Each mixer channel should have a 4 band EQ whereof at least 2 bands have sweepable mids and adjustable Q. If the mixer can not supply this, 31band equalizers on all mixer outputs will be highly appreciated (though, not a requirement) In addition, we require: a 31band EQ for the PA system (can be omitted if the mixer has EQ on this output), one SM58 microphone or similar at FOH mixing position (talk to stage), one stereo minijack to XLR cable or equivalent at FOH (to connect an mp3 player or similar device to the mixer). Other notes: If possible, all loudspeakers and PA should be rigged before our arrival. All loudspeaker processors and crossovers should be available to us for fine tuning. All wiring visible on stage should be carried out using black cables (not grey, not blue) The sound is operated from the centre back of the auditorium. We bring 1 mac computer and 1 sound card

(8 outputs on XLR / balanced jack), and this is our only sound source during the show. 5) Schedule and other requirements 09:00 14:00 set up 14:00 16:00 focus, sound check, warm up dancers on stage 16:00 18:00 rehearsal 19.30 or 20.00 SHOW In case of earlier start of the show, it is necessary to start with the set up one day before the show 2-3 heated dressing rooms with mirrors, shower and kettle required. Tea and coffee would be heartwarming. Copyright: The organizer is obliged to provide for copyright for songs used in the production, that is make a contract with a respective collective right management organisation. The list of music is an attachement of the contract. The remaining copyright fees are included in the overall fee. Contact us at: Marta Lajnerová, company manager: marta@420people.org, +420 602 666 592 Jan Mlčoch, technical director: antonaut@volny.cz, +420 605 977 766 Please let us know as soon as possible if you have any problem providing anything we ask for. We can usually make substitutions or changes if we know about any problems in advance.