3A TC 699/SIP/UK/12

Similar documents
FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

Medium Box for Cable Termination

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

FIST-GCO2 GCO2-BC8 GCO2-BD8 GCO2-BE8 GCO2-BF8. 5 Heatshrink installation. 1 Introduction. Content. 6 Fiber routing. 2 General. 7 Fiber routing on tray

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

FOSC 450 C6 and D6 Closures

GCO2-BC6/16-MC-XV GCO2-BD6/16-MC-XV GCO2-BE6/16-MC-XV. 3.1 Installation of the workstand 3.2 Opening the FIST-GCO2

GCO2-BC6/16-XX GCO2-BD6/16-XX GCO2-BE6/16-XX

Ordering Guide of the Fiber-Optic Splice Closure (FOSC-400)

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

Gel-sealed in-line fiber optic closure

3M Distribution Box (DDB)

Ordering Guide. for FIST-GCO2 product range

SLiC Fiber Aerial Closure System

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

Ordering Guide of the Generic Closure Organizer (FIST-GCO2)

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Installation Instructions

2178-L/S Series Fiber Optic Splice Case with Gasket

Ordering Guide. for FIST-GSS2 product range

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

3 SLiC Aerial Closure with Rubber End Seal

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

HCS - HES Cabling Systems

Instructions. Cable with Armor F CAUTION. October Rev A

FOSC-450 Product Range Ordering Guide

INSTALLATION INSTRUCTIONS

18mm ECAM Cable Entry Port

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

3M Fiber Closures BPEO

FOSC 400 A4 Fiber Optic Splice Closure

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

3M Better Buried Compound Compression Closure System

3M Better Buried Closures

LEGEND POWER SYSTEMS

3M Coupling Tray FDTC-10S-COUPLINGTRAY

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

3M Fiber Optic Wall Mount Enclosure 8430 Series

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

27mm ECAM Double Cable Entry Port

FOSC 400 B2/B4. Fiber Optic Splice Closures. Table of Contents. Page 1

INSTALLATION INSTRUCTIONS

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Fiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]

LANmark-OF ENSPACE Patch Panel

Optical Distribution Box 300 Installation Guide. Version : R0.0

4320 SS-25 Self-Strip Terminating Block

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

Installation instructions Roxtec RM ES B

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box


3M Cold Shrink Splice Kit QS-III 5515A

FOSC 400 C5 & D5 Fiber Optic Splice Closures

3M Cold Shrink Splice Kit QS-III 5514A

Installation instructions Roxtec RM PE B

IP-LINX. Installation Guide

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

Fiber Optic Splice Closure GPJ Instruction Manual

Clearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

Cold Shrink Straight Joint

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

Instruction manual. Midi Fiber Dome. Instruction manual

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

2178 L/S Series Fiber Optic Splice Cases and Accessories

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

RAIL D-SUB BACKSHELLS

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

Panduit Recommended Best Case Practice Split Fibre

VITALink Taped Splice Straight Through Crimp

3M Locator Plate N

Quick Release Roof-Mount Kit MB700

3M Cold Shrink Foldback Splice Jacket Kit

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3M Fiber Optic Closure System LL

K & B Flame Retardant Building Riser Closures

INSTALLATION INSTRUCTIONS MO023A

Identification - electrical services

Public Works Division Lighting District Fiber Optic Specifications April 2009

ENERGY /// TRICKS OF THE TRADE TRICKS OF THE TRADE

GENUINE PARTS ! CAUTION

Crimp & Cleave Termination Instructions for SEL ST Connectors

3M Cold Shrink Splice Kit QS-III 5416A

Transcription:

Hybrid OTIAN Node I N S T A L L A T I O N I N S T R U C T I O N Generic Joint 3A - Item Code 006825 TC 699/SIP/UK/12 07/15 - Helpline 01793 572453 Contents 1 General description 2 Capacity 3 Kit contents 4 Opening closure 5 Tray assembly 6 Cable port selection and preparation 6.1 Installation of COF 200/COF201 6.2 Installation of COF 200/COF 201 looped in the oval port NOTE: Shield continuity wire installation! 6.3 Installation of 4/7BFT and COF 200/201into ports 3 to 10 1 General description 7 Fibre routing 8 Cable grounding/shielding attachment 9 Closing the closure 10 Re-entry procedure 11 Quality checks BT Safety procedures and working practices must be followed at all times. This joint closure is for installation in the external network and BT exchange cable chambers only. The closure can be used as a distribution node, using single circuit trays or as a Hybrid node using both single circuit and single element trays. The closure is a single-ended design made of a thermoplastic material. The base and dome are sealed with a clamp and an O-ring. One oval entry port for looped (uncut) cable management and sixteen round ports for single cable entry/exit are included in the base. The cable seals are manufactured from heat-shrinkable material. The Universal Mounting System provides the foundation for mounting Splice Only Sub- Assemblies (SOSA) and Splitter Array Sub-Assemblies (SASA) back to back. Uncut loose tube storage is available between the two UMS-sides (Universal Mounting System). The 8 large 20mm ports in the centre of the base are to be used for external black polyethylene (PE) 7 or 4 (3.5/5.0mm tube) Blown Fibre Tube (BFT) cables and/or COF 201.The oval port can also be populated with two external black PE 7 or 4 (3.5/5.0mm tube) BFT cables or a looped COF 200/COF 201.The small 13.5mm ports are to be used for COF 200 or external black PE 1 or 2 tube (3.5/5.0mm tube) BFT cables. 2 Capacity The recommended tray layout for 48 single circuits plus additional single element capacity is as follows: Up to 8 single element trays (2 x SOSA SE4) and up to 48 SC trays (6 x SOSA SC8). Dimensions Length 566 mm Diameter with clamp 285 mm Associated support products OTIAN SOSA SE4 3A 006826 OTIAN SOSA SC4 3A 006827 OTIAN SOSA SC8 3A 006828 Circular port kit 3A 006846 Oval port kit 3A 006847 Heat protection kit (SCOP) 003584 Tube water block 3A 006848 Transparent tube 3mm 006849 Collets split 3A 006890 Element support tube 3A 008121 MOBRA 3A 006829 MOBRA 3A lifting strap 006830 MOBRA 3A extension tool 006831 MOBRA 3A CCJ 023859 Clamp & O Ring 023237 Loop insert tool 3A 006850 Closure Sealant 10B 039962 Stripper cable sheath No7 126853 Cutter cable hand No 5A 127451 Straps fixing 1A (tie wrap) 071814 Collet marker n 2 yellow 072796 D nozzle 126709 Strap cable fixing1 natural 071813 Protector splice 5A 076071

3 Kit contents 5 Tray assembly It is recommended that element trays are installed before single circuit trays as shown in the picture below. Note: even numbered ports are on the A side odd numbered ports and valve are on the B side 1 x Dome & base including pressure relief valve 1 x Clamp & O-ring 2 x Tray lids including fibre guiding pins & tube holders 2 x Routing block covers and metal tray supports 1 x Nylon bolt 1 x Allen key for strength member attachment 1 x Cable preparation templates 1 x Installation instructions 3.1 Ensure the MOBRA 3A (006829) is pre-installed in the Joint box; if being used as a CCJ use the MOBRA 3A CCJ (023859). If Desiccant pack supplied, please discard. An example of a general layout as shown. Alternatively in a joint box, a no drill MOBRA may be used. See ISIS EPT/COF/D897 for details. 4 Opening closure 5.1 Remove the HOOK AND LOOP FASTENER and routing block cover. To remove the routing block cover lift the two snaps at one side of the cover. Note: tray support fitted to cover. 4.1 Open and remove the clamp. Remove the dome, keeping the O-ring in place. Note: take care with the O-ring and avoid damaging the sealing surfaces on the base and dome. Clean only with clean water or with a cleaning cloth. 2

5.2 Fix the wraparound groove plate on the uprights by putting the plate with the long protrusions in the left hand side of the uprights. 5.5 Place a single circuit tray in the wraparound groove plate face up in the lowest possible position. Do this by pushing the lip on the groove plate slightly down with the tray and move the tray laterally to the right into the hinge-cavities of the groove plate. 5.3 Press back on the right hand side and at the same time slide the plate to the right until it locks (snaps).into place (do not leave gaps between groove plates). 5.6 The single element tray is installed on the second from bottom position, then fitted on every other hinge point. Always leave one hinge point between SE trays. 5.4 To remove push the two snapfits at the right hand side and slide the plate towards the left hand side. 3

5.7 Starting from the bottom position on the groove plate on side A install the trays. Hint: it is recommended that as each tray is added fibre is installed onto that tray before the next tray is added. 5.9 If the closure is in a vertical position you will have to support the trays above the selected one using the tray support. This fits in the holes of the wraparound groove plate under the trays. Position the support carefully so that the groove is still accessible for the fibres and be careful not to push the support against fibres.to remove the support, use two hands to pull on both ends (near the groove plate). 5.8 To remove the tray put the fibre guiding pin between the lip on the wraparound groove plate and the tray and move laterally towards left hand side. 4

6 Cable port selection and preparation Mandatory Requirement: when used as a cable chamber joint the cables must be gas blocked using Closure Sealant 10B. 6.1.2 Open the selected port using a piece of rip cord. Hint: it may help to start if a nick is put in the port. The cable to port selection for the installation of BFT and COF is shown in the table below Port/Cable selection table Ports COF 200 COF 201 BFT COF 26 COF 27 1 to 10 240/276/ 96 to 144 F 4 to 7 tube 16 F 48 to 96F 288 F 11 to 18 12 to 144 F 12 to 48 F 1 & 2 tube - 8 to 24 F Oval port up to288f up to144 F 4 & 7 tube - 144 & 240 F 1 & 2 Degrease the port using the cleaning tissue provided and circumferentially abrade. 6.1.3 Remove 2 metres of cable jacket. Cut the strength member to 75mm and remove the coating over the end 15mm. See ISIS Document EPT/COF/D637 for cable stripping detail. Clean and abrade the cable jacket for a length of 220mm from the cable butt. Caution: always use a Cutter Cable Hand 5 to cut the strength member. This ensures a controlled cut. Other types of tools such as Side Cutters must NOT be used. 6.1 Installation of COF 200/COF 201 in small ports 6.1.4 Position the large SCOP from the heat protection kit (003584) 15mm from cable butt. Position blue line on foil 110mm from cable butt as template. Note: foils have sharp edges, please use with care. Smooth the cable protection foil with a blunt tool. 6.1.1 COF 200/COF 201 (12 to 48 fibre ) input primary cables shall be installed in the small ports. Begin with port 12 on the (A side) or port 17 on the ( B side). If COF 200/COF 201 is used as a ongoing (SE) distribution cable, use port 18 ( A side) or port 11 ( B side). Use the COF Template provided at the back of this instruction booklet to aid in cable preparation. Note: COF 201 larger than 48 fibre can be installed in ports 1 to 10. See Template at the back of this instruction booklet to aid in cable preparation. 6.1.5 Attach strength member clamp to closure using screw provided. Tighten the strength member clamp using the (2 mm) Allen key provided. 5

6.2 Installation of COF 200/COF 201 looped in the oval port In conjunction with the template at the end of this instruction, prepare a windowcut of 3.8 m (i.e.1.9 m each side of the reversal point) as described below. A B 6.1.6 Pass cable through heat shrink sleeve and then into the closure. Note: ensure the ARROW on the sleeve points towards the base. The sleeve will not milk off if this is done. Note: use the heat-shield as required to protect occupied or un-occupied ports whilst shrinking the port seal. 6.2.1 Mark the cable in the middle of the loop and remove cable jacket both sides of the mark over a total distance of 1.2mts. Locate the tube reversal point on the cable as shown in the picture and mark the cable 1.9 mts each side. Remove the jacket to these points. Important: make sure that twist position of loose tube is identical in A and B. If this is not done correctly it will be very difficult to access the cable elements at a later date. Attach the moisture barrier connection as described in ISIS EPT/COF/ D505. NOTE: Shield continuity wire installation In order to install the shield continuity wire assembly, use a cable sheath cutter. Cut the cable jacket over a length of 20mm and a width of 10mm. Using PVC tape start under the cable jacket strip. Install the shield continuity wire on the cable jacket strip using a standard pair of pliers. 6.1.7 Using a D nozzle start shrinking the tube from the top, continue shrinking and converting the paint until the heat shrink is totally recovered. Allow the sleeve to cool for approx 10 minutes before moving. Quality check, all paint converted and a visible flow of adhesive at the end of the sleeve. Mandatory Requirement: when used as a cable chamber joint the cables must be gas blocked using Closure Sealant 10B. Wrap the entire shield continuity clip with PVC tape. 6

6.2.2 Using Cutter Cable Hand 5 cut the strength member to 75mm and remove the coating over the last 15mm. Clean and abrade the cable jacket for a length of 220mm from the cable butt. Prepare the cable ends as shown in the COF 200/COF 201 template. Ensure the large SCOP is used from the heat protection kit. Note: foils have sharp edges, please use with care. Smooth the cable protection foil with a blunt tool. 6.2.3 Fix the cables to the bracket supplied with the oval seal kit as shown. Cover the worm drive clips with PVC tape. 6.2.4 Open the oval port using a rip cord. Hint: it may help to start if a nick is put in the port. Degrease the port using the cleaning tissue provided and circumferentially abrade removing any burrs around the port opening. 6.2.5 Gently bend the tubes over a loop insert tool (Item code 006850) and pass through the heat shrink sleeve. Note: make sure the arrow on the sleeve points to the base. The sleeve will not milk off if this is done 7

6.2.6 port. Still using the loop insert tool pass the tubes through the oval 6.2.7 Gently pull all the tubes into the closure and secure the loop bracket in the closure using the split pin supplied. 6.2.8 If using15 tubes or less, tubes can be stored between the tray mounting frames as shown. For element numbers greater than 15 (COF200 up to 288F) all elements can be stored as shown above. Before fitting into the plastic sleeve, secure the elements in a loose coil using strap cable fixing 1 Natural, item code number 071813 (non locking). 8

6.2.9 Insert the 3 fingered clip between the cables. Using a D nozzle start shrinking the tube from the top, continue shrinking and converting the paint until the heat shrink is totally recovered. Lightly tape the cables together to prevent them moving during the cooling period. Note: use the Heat-shield as required to protect occupied or un-occupied ports whilst shrinking the port seal. 6.2.10 Allow the sleeve to cool for approx 10 minutes before moving. Quality check, all paint converted and a visible flow of adhesive from the clip and at the end of the sleeve. COF 200 in a Cable Chamber Joint, Mandatory required to gas block using Closure Sealant 10B. COF200 in a Track Joint or Node no blocking requirement with Closure Sealant 10B. 6.3 Installation of BFT and COF200/201 into ports 3 to 18. See port selection table in section 6. It is preferred to install 1 & 2 tube BFT into ports 11 to 18 although the 1 & 2 tube BFT can be installed into ports 3 to 10 if all small ports (11 to 18) are already used. A template is provided at the back of this instruction to aid cable preparation. Distribution ports (blown fibre) are to be used in sequence from right to left. i.e. A side ports 10 to 4 B side ports 3 to 9. 9

6.3.1 Open the selected port using a piece of rip cord. Hint: it may help to start if a nick is put in the port. Degrease the port using the cleaning tissue provided and circumferentially abrade. 6.3.2 Remove 200 mm of cable jacket (see ISIS Document EPT/ COF/D637 for cable stripping detail). Clean and abrade the cable jacket for a length of 220mm from the cable butt. Position cable protection foils & also SCOP s for Internal cables as shown in the templates. For COF 200/201 see template at the back of this instruction. Note: foils have sharp edges, please use with care. Smooth the cable protection foil with a blunt tool. 6.3.4 After passing the cable through the port, attach the moisture barrier connection to the cable as ISIS EPT/COF/D505 if required. Pull the cable back into the port until the end of port mark on the cable jacket lines up. See template. Note: Moisture barrier connection is NOT required for Blown Fibre Tubing. 6.3.3 Pass cable through heat shrink sleeve and then into the closure and position heat shield. Note: ensure the ARROW on the sleeve points towards the base. The sleeve will not milk off if this is done 6.3.5 Attach cable strength member as shown. 10

6.3.6 Position Heat-shield & using a D nozzle start shrinking the tube from the top, continue shrinking and converting the paint until the heat shrink is totally recovered. Allow the sleeve to cool for approx 10 minutes before moving. Quality check, all paint converted and a visible flow of adhesive at the end of the sleeve. 6.3.7 Cut tubes to length (between base and tube holder) and install Tube Water Block 3A I/C 006848. Block the cable with Closure Sealant 10B. Install Transparent tube 3mm (I/C 006849) from water block up to tube holders. 11

7 Fibre Routing This joint is suitable for both dual and single fibre working practices and fibre circuits can be routed to any tray within the joint from any cable position. To allow circuits to be routed from one side of the joint to the other, fibre can be routed through the transfer port. Elements are to be routed and stored first, followed by single circuits. Fibres must be routed in number/colour from the lowest start position and store the fibres safely within the trays. Note: the element tubes from COF 200/COF 201 and the 3mm tube from a BF water block are both installed in the same way. Fibre Numbering Colour Scheme 1 Blue 2 Orange 3 Green 4 Red 5 Grey 6 Yellow 7 Brown 8 Violet 9 Black 10 White 11 Pink 12 Turquoise Note: all tubes require collets (I/C 006890). Warnings 1 Spare or dark fibres must be clearly identified and stored on separate trays. 2 Use pen marker No 1 (I/C 129408) to record the fibre, element and cable number on the trays. 3 Fibre must not be stored in the routing area. 4 Take care when routing fibres as existing fibres may be live. 7.1 COF 200/COF 201 Route the element tubes to the nearest/most convenient tube holder. Slide the element support tube 3A over the element tubes down to the cable butt and mark the length to just under the selected tube holder. Remove element support tube 3A, cut to length and re-install over the element tubes. Note: element support tube can be installed onto previously installed cable elements by carefully making a longitudinal cut with scissors. 7.2 Position the element tubes in the selected tube holder and mark the tubes between the two marks that are moulded into the tube holder. Remove from the tube holder and cut the element tubes to these marks. Degrease and clean the fibres ready for storage. 12

7.5 Route the fibre in the groove alongside the trays to the entrance of the required tray. Fibre must be routed in the groove below the hinge of the tray. 7.3 Install split colletts (Item Code 006890) as shown above. Re-install the tubes in the tube holder and slide in a tube holder cover with the slot facing up. Use the lowest position to secure all elements. Note: the tube holder must click into place. 7.6 Store fibre safely beneath the tabs and ensure that it is loosely coiled. Identify on tray. Note: the crossover in the centre of the tray can be used for reversing direction of fibre. 7.4 Different tubes can be put together beneath the same tube holder retainer. Position one or more loose tubes in the tubeholder and slide the tube holder retainer with the slot facing up in the lowest possible cavity above the loose tube(s). The tube holder retainer must click into place. 7.7 Alternative Routing Fibres can be routed to the other side of the joint through transfer port as shown in the diagram. Route in number/colour order from the lowest position and store fibres safely within trays. Note: fibres can be routed either side of the closure using the transfer port. Installation tip: use a short length of portex tube (or similar) as a fibre guide and remove when finished. 13

7.8 To allow full flexibility for routing purposes, fibres can be routed left to right and also right to left. 7.9 For the storage of fibre, route from the tube holders up to the splicing trays and store as required (SE tray shown as an example). Identify on tray. 7.10 Blown Fibre Routing Route the blown fibre tube to the nearest/most convenient tube holder. Install water block (I/C 006848) and transparent tubing (I/C 006849). Position in tube holder and mark the tubes between the two marks that are moulded into the tube holder. Remove from tube holder and cut tubing from this mark. Strip bundle and clean the fibres ready for storage. 7.11 Blown Fibre Distribution Route the required Distribution blown fibre to the required Primary input tray. Prepare fibre for jointing and store safely on tray when completed. Note: generally route Distribution fibres to the right-hand side of the tray. Alternative routing can be used, as shown in previous examples. 14

9 Closing the closure Ensure all fibres are identified on trays correctly. 7.12 Splice Holder positions 8 Cable grounding/shielding 9.1 Install tray lids including fibre guiding pins and tube holder covers on top trays. 8.1 All cable grounding/shielding wires must be connected to the nylon bolt along with the wire from the pressure relief valve, store safely in the base of the closure. Note: Moisture barrier connection is NOT required for Blown Fibre Tubing. 9.2 Replace the tray support onto the routing block cover and install over the routing block. Secure the hook and loop fasteners. Check position of O ring, place dome over closure and install clamp. Note: the legs on the clamp lever can be used to close the clamp. 15

10 Re-entry procedure Open pressure relief valve See page 2, step 4 Opening the closure Inspect O ring & clamp. A maintenance kit is available ( I/C 023237 ) containing O ring & clamp 11 Quality checks Heat shrink port seals installed with ARROW up, paint converted & visible flow of adhesive from end of sleeve Minimum bend radius of cables & fibres maintained Fibre joint & cables labelled correctly Fibre joint/customer terminating unit correctly labelled Cable preparation, fibres thoroughly de-greased & continuity correctly fitted Fibres clearly identified, routed & stored correctly Trays fitted correctly with information recorded on each tray using pen marker No.1 (I/C 129048). Check that Closure Sealant 10B has been used where required as stated in these instructions (e.g. when used as a cable chamber joint). 16

COF 200 Loop Note: remove 3.8 m of sheath. Note: use largest SCOP

Template for 4 & 7 Tube Blown Fibre Cable External

COF 200/201 template for round ports Note: use largest SCOP 19

Help Line A help line is available at Tyco 01793 572453 Tyco Electronics UK Ltd. Faraday Road Dorcan, Swindon Wiltshire SN3 5HH Tel.: 01793 572453 Fax: 01793 572604 20 TE (logo) and TE Connectivity are trademarks of the TE Connectivity group of companies and its licensors. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity obligations shall only be as set forth in TE Connectivity Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. TC 699/SIP/UK/12 07/15