ipump6400 Professional Media Server User s Manual

Similar documents
Professional Media Server Quick Start Guide

Correspondence regarding this publication, Revision A First Edition: November 2003

ipump 622 Streaming Media Decoder Installation Quick Start Guide

DTV742 Installation Quick Start Guide

DTV744 Installation Quick Start Guide

ipump 525 IP Media Player Quick Start Guide

ipump 562 Digital Media Server Quick Start Guide

WEGENER i6420 DIGITAL AUDIO SERVER QUICKSTART INSTALLATION INSTRUCTIONS

WEGENER i6420 DIGITAL AUDIO SERVER QUICKSTART INSTALLATION INSTRUCTIONS

Unity 552. Digital Media Receiver Installation Quick Start Guide

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Dell Wyse 5030 PCoIP Zero Client

DTV701 Broadcast Digital Television Processor. User's Reference Manual

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

For flexible advertisement insertion configurations, this receiver provides four types of outputs:

DSR-7400 Series. Commercial Integrated Satellite Receiver/Transcoder. Highlights. Product Overview

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Installation Guide. Model DVR395/DVR396 DIGITAL VIDEO RECEIVER

Instruction Manual Model # Block Upconverter

DTV742. 8VSB 4-Channel Multiplexer. User s Manual

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Cisco D9859 Advanced Receiver Transcoder

MediaKind RX

Instruction Manual Model BlockUpconverter

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Installation & Operational Manual

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

AVE HOME FAGOR CVBS TO DVB-T ENCODER MODULATOR. Fagor Electr6nica

Digital Video Recorder

Quick Operation Guide of LTN7700/7600 Series NVR

Model /29S RF Splitter

Cisco D9859 Advanced Receiver Transcoder

Instruction Manual Model Block Downconverter

Instruction Manual Model Downconverter

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Model P/03P Upconverters

WNE CLIENT V.4.2 EMR CONFIGURATION GUIDE SEPTEMBER 30, 2010

ipump 562 Digital Media Server ipump 562 Digital Media Server User s Manual Rev. A

FS3. Quick Start Guide. Overview. FS3 Control

10MHz Source/Inserter

Cisco D9865 Satellite Receiver

Ultra-ViewRF 8HD Director Monitor. User Operation Manual

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DTV735 Digital Television Processor Fox Version. User's Manual

QRF5000 MDU ENCODER. Data Sheet

Video Series. HCS-4311M Professional Mixed Matrix for Conference 8.2. HCS-3313C High Quality Speed Dome Camera (ceiling) 8.5

SECTION 686 VIDEO DECODER DESCRIPTION

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

Instruction Manual Model Block Upconverter

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

TimeView Display. Operating Manual

ipump 562 Digital Media Server User s Manual

Video Disk Recorder DSR-DR1000

DTE-1000 MPEG2 SD ENCODER

DIVERSITY DVB-T RECEIVER (DDR)

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

DCD-24 Word Clock Distributor

FS4 Quick Start Guide

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

User Manual CONTENTS. Title and Contents Important Safety Instructions and Introduction... 2

Cisco D9865 Satellite Receiver

Kramer Electronics, Ltd. USER MANUAL. Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher

Amb-OS Media, LLC AMR-100

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

X-Band Redundant LNB Systems

Cisco DAXI. Features. Data Sheet. Cisco DAXI. Figure 1.

SAT IF distribution system

Operating Instructions

Ku-Band Redundant LNB Systems

AMD-53-C TWIN MODULATOR / MULTIPLEXER AMD-53-C DVB-C MODULATOR / MULTIPLEXER INSTRUCTION MANUAL

MON3-2W/HR MON4-2W/HR (Document P/N Rev-B)

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

T3316 IP QAM Modulator User Manual

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

MyM-3S Micro Master. Installation Guide. English. design for TV

DINOX&Digital&Video&Recorder&

DISTRIBUTION AMPLIFIER

Introduction...2. Features...2 Safety Precautions...2. Installation...4

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

EVD-L04/100A1-960, EVD-L08/200A1-960 and. EVD-L16/400A1-960 DVRs. Quick Operation Guide

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

Intelligent Security and Fire Ltd

ACTIVE IF SPLITTER/COMBINER UHP-IFS

USER MANUAL. Kramer Electronics, Ltd. Models:

3GSDI Audio Embedder

PD1600. Satellite Gateways. Media Distribution. Headend in a Box. Applications. Features

HDMI-8x8. MicroQ User Manual APANTAC LLC, 7556 SW BRIDGEPORT ROAD, PORTLAND, OR TEL: , FAX:

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

Operation and Installation Guide

C-Band Redundant LNB Systems

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

OPERATING INSTRUCTIONS TOM-0431IP

SV-LCD50. Installation and User Guide. Thin-Film Transistor (TFT) Liquid Crystal Display (LCD) Color Rear Vision Monitor. Version 1.

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

QRF5000 MDU ENCODER AND QAM MODULATOR

Transcription:

ipump6400 Professional Media Server User s Manual

Data, drawings, and other material contained herein are proprietary to Wegener Communications, Inc., and may not be reproduced or duplicated in any form without the prior written permission of Wegener Communications, Inc. The information contained herein is subject to change without notice. Revisions may be issued to advise of such changes and/or additions. WEGENER, COMPEL CONTROL, MEDIAPLAN, ENVOY, UNITY, UNITY IP, and ipump are trademarks of Wegener Communications, Inc. All other trademarks are the property of their respective owners. 2004 Wegener Communications, Inc. All rights reserved. Portions copyright 1992-2001 FairCom Corporation. "FairCom" and "c-tree plus" are trademarks of FairCom Corporation and are registered in the United States and other countries. All Rights Reserved. Correspondence regarding this publication, 800009-01 Revision B Second Edition: May 2004 should be forwarded to: Wegener Communications, Inc. Technology Park/Johns Creek 11350 Technology Circle Duluth, GA 30097-1502 Phone: 770-814-4000 Fax: 770-623-0698 The Wegener ipump6400 is approved under FCC Part 15B Class A, UL1950, CSA, and CE. 800009-01 Rev. B 2 wegener.com

Table of Contents Chapter 1 General Information 1.1 Manual Overview........................................ 7 1.2 ipump6400 Overview..................................... 8 Physical Description...................................... 8 Functional Description.................................... 8 Status Monitoring...................................... 8 Live Program Play..................................... 8 Record Program to File.................................. 8 Play Recorded Program File.............................. 9 File Management...................................... 9 Playlists.............................................. 9 Routing.............................................. 9 Stream Creation....................................... 9 Scheduled Operation................................... 10 File Downloads....................................... 10 Files Served to LAN................................... 11 Compel Control....................................... 11 HTML Control....................................... 11 Contact Closure/Alarms................................ 11 ipump6400 Options...................................... 11 Table 1iPump6400 Options Key.......................... 12 1.3 ipump6400 Specifications................................. 14 Table 2Technical Specifications........................... 14 1.4 Safety Summary......................................... 15 1.5 Glossary of Terms and Abbreviations........................ 16 Table 3Glossary of Terms................................ 16 Chapter 2 Installation 2.1 Unpacking and Inspection................................. 19 2.2 Location and Mounting................................... 19 2.3 ipump6400 Connections.................................. 22 Table 4iPump6400 Connector Details...................... 23 Alarm Connector Details.................................. 23 Table 5iPump6400 Alarm Connector Pin Functions.......... 24 Ethernet/LAN Port Details................................ 24 Table 6iPump6400 LAN Connector Pin Functions........... 24 Optional Decoder with Digital Output....................... 25 Table 7Digital Output Decoder Connectors................. 25 Table 8Balanced Analog and AES/EBU Digital Audio Connector Pin Functions........................................ 26 Multiswitch Connection Details............................ 27 Table 9RF Port Selection Signals.......................... 27 wegener.com 3 800009-01 Rev. B

Chapter 3 Operation 3.1 Operation Overview...................................... 29 3.2 Front-panel Controls and Indicators......................... 30 Liquid-crystal Display(LCD).............................. 30 Push buttons............................................ 30 LED Indicators......................................... 31 Table 10LED Indicator Descriptions....................... 31 3.3 Startup/Shutdown Procedures.............................. 33 Initial startup........................................... 33 Normal Startup......................................... 33 Web Browser Operations Startup........................... 34 Normal Shutdown....................................... 35 3.4 Front-panel Operation.................................... 36 LCD Menu Navigation................................... 36 Editable Fields.......................................... 37 Selectable Fields........................................ 38 3.5 Initial Unit Setup........................................ 39 Initial RF setup......................................... 39 Table 11iPump6400 Preconfigured RF Settings.............. 39 Current Channel Setup.................................... 39 LNB Type Selection..................................... 41 LNB DC Power Setting................................... 42 Date/Time Setup........................................ 43 Unit Label Setup........................................ 45 3.6 ipump6400 Operations by Function......................... 46 Monitor ipump6400 Status................................ 46 Live Program Play....................................... 47 Record Program to File................................... 50 Play Recorded Program File............................... 51 File Management........................................ 52 File Streaming and Routing................................ 53 Scheduled Operation..................................... 54 Playlist Management..................................... 55 ipump6400 Help........................................ 57 3.7 Unit Software Switch..................................... 58 Chapter 4 Maintenance and Troubleshooting 4.1 Maintenance............................................ 59 4.2 Troubleshooting......................................... 59 No functions at all....................................... 59 No output.............................................. 60 Trouble using browser interface............................ 60 LED Indicators......................................... 60 Table 12LED Indicator Descriptions....................... 60 800009-01 Rev. B 4 wegener.com

Chapter 5 Customer Service 5.1 Warranty.............................................. 63 5.2 Technical Support....................................... 63 Index wegener.com 5 800009-01 Rev. B

This page intentionally blank 800009-01 Rev. B 6 wegener.com

Chapter 1 General Information 1.1 Manual Overview This manual provides instructions and reference information for the proper installation and operation of the Wegener ipump6400 Professional Media Server, referred to throughout the manual as the ipump6400. The manual is divided into the following chapters: 1 General Information - a description of your ipump6400, its functions and specifications, and a glossary of terms. 2 Installation - procedures and information for the correct and safe installation of your ipump6400. 3 Operation - instructions on starting and operating your ipump6400. 4 Maintenance and Troubleshooting - information on maintaining your ipump6400 and resolving possible operating difficulties. 5 Customer Service - Our warranty and information on obtaining help. An Index of keywords is also provided to help you quickly locate needed information. Please email any suggestions or comments concerning this manual to manuals@wegener.com. If you prefer to post through the mail, please send your comments to the address below. If you have substantial or complex changes to recommend, our preference is that you copy the page(s) in question, mark your changes on that copy, and fax or mail us the copy. We always appreciate constructive criticism. Our Address: Attn: Manuals Wegener Communications, Inc. Technology Park / Johns Creek 11350 Technology Circle Duluth, GA 30097-1502 Our Fax Number:(770) 497-0411 wegener.com 7 800009-01 Rev. B

1.2 ipump6400 Overview The Wegener ipump6400 is an integrated, digital satellite receiver, decoder, and media server designed to provide the most cost effective method of delivering and storing digital content for broadcast, cable, and business operations. The ipump6400 is a key part of the Wegener Communications Digital Media Delivery System which combines secure MPEG and IP digital transmission with media management and server storage. At a given time, up to 260 hours of media content can be stored on a single ipump6400 (with optional, large disk capacity) and served out via Ethernet according to current need or predetermined schedules. With the ipump6400, you can receive, decode, and play out broadcast-quality transmissions while at the same time receiving from satellite and recording multiple programs or IP data files. Combined with our Compel MediaPlan software, the ipump6400 can also place spot segments into real-time or recorded programs and can schedule playback of custom sequences of live and recorded content. Physical Description Functional Description The ipump6400 is housed in a standard, 2 RU, rack-mountable chassis. Its front panel provides a user interface through an LCD and six push buttons (see Figure 3.1 ipump6400 Front Panel on page 30). The rear panel holds the power switch and the ports that allow connection to power, incoming signal, and peripheral devices. Your ipump6400 can perform the following functions: Status Monitoring Front-panel and web browser interface screens allow real-time monitoring of ipump6400 activity, settings, and signal characteristics. Live Program Play The ipump6400 decodes an incoming DVB MPEG program from the received satellite signal. It decrypts and decodes the audio and/or video from the selected program through analog or digital output ports to your monitor or transmission equipment. The incoming content may be either a "classical" DVB program or an IP multicast stream. RF and decoder settings are selected by the user. Two live programs from the same DVB carrier may be played simultaneously by ipump6400s that have the optional second decoder. Record Program to File The ipump6400 can simultaneously record up to three separate multiplexed programs (either "classical" DVB or IP multicast stream) from the incoming stream including any that are played live to the decoder(s). The user selects the 800009-01 Rev. B 8 wegener.com

programs and enters a file name, audio setting, and a recording time (duration) for each. Files are recorded to disk in the ipump6400 for later play-out or downloading. Up to 40 GB of storage (up to 43.3 hours of programming depending on data rate) is available on standard ipump6400s and up to 240 GB on optional, extended-storage ipump6400s (see Disk Storage Capacity). Record and play functions can be used in such applications as "tape delay"/ time zone shifting, "spot" localization of commercials, and corporate training media distribution. Play Recorded Program File The ipump6400 plays out the selected, stored program files to the connected audio and video monitors. File playing may be initiated by a predetermined schedule via Compel or by a schedule stored internally to the ipump6400. The user may also command playing of files directly from a web browser or from the front panel. Two recorded programs (or one recorded and one live) may be played simultaneously on ipump6400s with an optional second decoder. File Management Compel users can rename or delete files stored on the ipump6400 and organize them into directories or folders. Renaming and deleting files may also be performed through a web browser connected to the ipump6400 over a LAN. Playlists Sequences of programs called Playlists can be created and stored on the ipump6400 by the user (locally or by COMPEL). Up to 100 Playlists can be stored in nonvolatile memory and played back with no interruption between programs. Settings can be made to repeat the playlist indefinitely, complete the playlist and repeat only the last program indefinitely, or complete the playlist and simply return the decoder to its previous state. Routing The ipump6400 can serve as a satellite-to-lan IP router. Both unicast and multicast IP traffic is supported. Multicast traffic can include, for example, MPEG video streaming data. The IGMP protocol is followed for multicast traffic. Stream Creation The ipump6400 can create IP multicast video streams and present them on the LAN for use by other equipment. The source of the video stream may be either a prerecorded or downloaded file or a "classical" DVB program. wegener.com 9 800009-01 Rev. B

The ipump6400 can also multicast previously-stored streams to the LAN. See Figure 1.1 ipump6400 Routing for an illustration of ipump6400 routing paths. Scheduled Operation Figure 1.1 ipump6400 Routing Schedules of record, play, and other operations for automatic execution by the ipump6400 may be set up using the Compel network and may be viewed from the web browser interface. (Schedule operations support wild cards and ranges in day, date, and time fields for repetitive events.) File Downloads The ipump6400 accepts files downloaded from the satellite link via Compel s Assured File Delivery package. Application software and other files may also be downloaded. Up to five downloads may be performed simultaneously up to an aggregate data rate of 25 Mbps. The ipump6400's file download and record functions may be used to load the unit with content for playout (according to a pre-arranged schedule if desired) at any time. This can be particularly useful in applications with extended or continuous playout needs and limited satellite operating times. 800009-01 Rev. B 10 wegener.com

Files Served to LAN Users sharing a LAN with the ipump6400 may download stored files from the ipump6400 to their local workstation or server using FTP or SMB protocol. Compel Control ipump6400 operation may be controlled remotely by a Compel network. Compel conditional access controls which ipump6400s may access the satellite s material and prevents access by any other receive equipment. Local control of the unit may be disabled for exclusive control by Compel. The ipump6400 always follows the most recent command received and does not prioritize commands based on origination from the front panel, web browser interface, or Compel network. HTML Control Control of the ipump6400 is available from any web browser on the LAN to which it is connected or via the internet if desired. The IP address and subnet mask can be displayed and changed at the ipump6400 front panel. Contact Closure/Alarms The ipump6400 provides a contact closure through a rear-panel connector whenever the unit enters an alarm condition. An additional user relay is also available. The ipump6400 can also sense a contact closure input. Using Compel, file playouts can be triggered by local closure of this input. ipump6400 Options The ipump6400 Professional Media Server is available in several configurations to meet specific applications. Input type, decoder type, disk storage capacity, Conditional Access, and the presence of a second decoder can be varied to create models best suited for your specific needs. wegener.com 11 800009-01 Rev. B

The ipump6400 model number is structured as follows to describe the options on each ipump6400: IP - ABC - D - EF - G - HH - JKK Table 1: ipump6400 Options Key Model Number Position Option Name Designator Description IP This prefix simply indicates that the unit is an ipump. A B C First Decoder Type (top slot) Second Decoder Type (middle slot) Input Type (bottom slot) 0 - No decoder 1 - Basic decoder 2 - professional 4:2:0 decoder with analog outputs 3 - professional 4:2:2 decoder with analog outputs 4 - professional 4:2:2 decoder with digital outputs 5 - professional audio output 6 - professional 4:2:0 decoder with analog outputs and channel 3-4 modulator connector 0 - No second decoder 1 - Basic decoder 2 - professional 4:2:0 decoder with analog outputs 3 - professional 4:2:2 decoder with analog outputs 4 - professional 4:2:2 decoder with digital outputs 5 - professional audio output 6 - professional 4:2:0 decoder with analog outputs and channel 3-4 modulator connector 1 - DVB RF Input 2 - ASI Input D Disk Storage Capacity 1-40 Gigabytes 2-80 Gigabytes 3-120 Gigabytes 4-160 Gigabytes 5-200 Gigabytes 6-240 Gigabytes E Contact Closure Module Type 1 - Alarm and contact closure in and out on DB-9 2 - Alarm and contact closure in and out on DB-9, plus RJ-11 internal modem F Channel 3-4 Modulator 0 - none 1 - present G HH Reserved Conditional Access Type 800009-01 Rev. B 12 wegener.com

Table 1: ipump6400 Options Key Model Number Position Option Name Designator Description J Line Cord (power connector) 1 - U.S. 2 - U.K. 3 - Europe 4 - Australia KK Other 00 - none 01 - Aux Audio 02 - KenCast FEC 03 - KenCast FEC plus Aux Audio 04 - OSD 05 - OSD plus Aux Audio 06 - OSD plus KenCast FEC 07 - OSD plus KenCast FEC plus Aux Audio wegener.com 13 800009-01 Rev. B

1.3 ipump6400 Specifications Table 2: Technical Specifications Characteristic Specification RF Input Frequency Input FrequencyRange Input Impedance LNB Power Tuning Resolution Modulation Transport Rate Range tuning via front panel control or COMPEL 950 to 2150 MHz 75 ohms 250 ma max, 22 khz tone control vertical polarity: 12.4 to 14.0 VDC horizontal polarity: 17.0 to 19.0 VDC 1 khz QPSK 2.0 to 45 Msps VIDEO COMPRESSION Video Data Rate up to 15 Mbps per service Compression Type MPEG 4:2:0 or 4:2:2 Horizontal Resolution 720, 704, 640, 544, 480, 352 Vertical Resolution 480 lines @ 30 Hz (NTSC) 240 lines @ 30 Hz (NTSC) 576 lines @ 25 Hz (PAL) 288 lines @ 25 Hz (PAL) VIDEO OUTPUT Video Format NTSC/PAL composite and SDI (with embedded audio) Output Level 1 Vpp ± 5% Output Impedance 75 ohms AUDIO COMPRESSION Compression Type Data Rate Output Modes Supported MPEG Layer II 64 to 384 kbps Mono, Dual Mono, Joint Stereo 800009-01 Rev. B 14 wegener.com

Table 2: Technical Specifications Characteristic Specification AUDIO OUTPUT Frequency Response 20 Hz to 20 khz GENERAL Power Supply 100 to 120 V or 200 to 240 V (auto switches) 60/50 Hz 5.0/2.5 A Size weight height width depth ~20 pounds (9.1 kg) 3.5 inches (90 mm) 19 inches (483 mm) [17 inches (432 mm) with mounting ears removed] 16"(406 mm) ENVIROMENTAL Use Operating Temperature Altitude Humidity Indoor only +10 C to +40 C Less than 2000 meters Maximum relative humidity of 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C. 1.4 Safety Summary The ipump6400 is designed for safe use with few special precautions required of the user. The following items are basic precautions to use when installing and working with your ipump6400: Do not open the ipump6400's chassis cover. wegener.com 15 800009-01 Rev. B

1.5 Glossary of Terms and Abbreviations Table 3: Glossary of Terms Term Definition AC Alarm AFD Authorized Carrier Compel Conditional access DVB EIA Alternating current A condition or notification of a condition that prevents your ipump6400 from performing properly. Assured File Delivery. Describes an ipump6400 which has the ability through Compel Conditional Access to decrypt programs encrypted by the Compel software. An RF signal containing coded audio, video, and/or other data. Wegener's network control software that may be used to manage a number of ipump6400s and other hardware. The means by which Compel controls which ipump6400s may decrypt specially encrypted audio, video, or data streams. Digital Video Broadcast Electronic Industries Association Ethernet The widely-used LAN technology specified by IEEE standard 802.3 FTP GB IEEE LAN LCD LED LNB Mbps, kbps or Msps MPEG Program Program Number RF File transfer protocol Gigabyte or 2 30 bytes Institute of Electrical and Electronics Engineers Local area network. Your ipump6400 may be connected to an Ethernet LAN. Liquid crystal display. The front-panel text screen on your ipump6400 is a liquid crystal display. Light-emitting diode. The front-panel indicator lights on your ipump6400 are LEDs Low-noise block downconverter - equipment (generally at the antenna) that converts the incoming satellite signal to the appropriate frequency for reception by the ipump6400. Units of data transport rate - Megabits per second (1 million bits per second), kilobits per second (1 thousand bits per second), or million symbols per second (1 million symbols per second) Moving Picture Experts Group - refers to the method of video compression established by this group. A single media stream (audio, video, data, etc.) tied to a common time base. A numerical code representing a program. Radio frequency 800009-01 Rev. B 16 wegener.com

Table 3: Glossary of Terms Term Definition SMB T MRA Warning Server message block - a protocol for requesting services from and reading and writing to a file server. Maximum Recommended Ambient Temperature, the highest operating temperature for which the unit is rated A condition or notification of a condition that may compromise the proper performance of your ipump6400 wegener.com 17 800009-01 Rev. B

This page intentionally blank 800009-01 Rev. B 18 wegener.com

Chapter 2 Installation This chapter provides instructions on unpacking, mounting, and connecting your ipump6400 as well as connector information including detailed pinouts. 2.1 Unpacking and Inspection Carefully unpack the unit and its ac power cord and inspect for obvious signs of physical damage that might have occurred during shipment. Also locate the bag of accessories including 1/8-to-RCA and SVD-to-RCA adapters. Any damage claims must be reported to the carrier immediately. Be sure to check the package contents carefully for important documents and materials. NOTE: Please save the packing materials and original shipping containers in case you must later return the unit for repair. Packing these units in other containers in such a way that they are damaged will void your warranty. 2.2 Location and Mounting The ipump6400 should be mounted in a standard 19-inch equipment rack. After mounting, maintain a clean, dry environment for the unit. WARNING This is a Class A product. In a domestic environment this product may cause radio interference for which the user may need to take mitigating action. wegener.com 19 800009-01 Rev. B

DANGER To avoid damage to this and other equipment, or personal injury, the following items should be strictly observed. Elevated Operating Ambient When equipment is installed in a closed or multi-unit rack assembly, the operating ambient of the rack environment may be greater than the room ambient. Therefore, consideration should be given to the ambient air temperature within the rack, and not just inside the room, when deciding if the maximum recommended ambient operating temperature (T MRA ) is being met. Reduced Air Flow Equipment should be installed such that airflow required for safe operation of the equipment is not compromised. The ipump6400 may be arranged in a rack without empty spaces between units if heat rise is prevented by ensuring its side vents remain unblocked with adequate clearance around the vent holes. Mechanical Loading Mounting of the equipment in a rack should be such that a hazardous condition is not produced by uneven loading. This unit is not very heavy, but total rack loading must be considered. Also, do not rest any unsupported equipment on your ipump6400. Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on overcurrent protection and supply wiring. Ensure that the total rack or breaker power consumption does not exceed the limits of the ac branch circuit. Appropriate consideration of equipment ratings should be used when addressing this concern. Reliable Earthing Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (use of power strips, chassis ground lugs, etc.). 800009-01 Rev. B 20 wegener.com

Your ipump6400 is sized at 2 RU and will fit an EIA-standard, 19-inch-wide equipment rack (See Size on page 15.). a) First, install angle brackets or cross-supports capable of supporting both the unit and its connecting cables. Screw or bolt the supports securely to the equipment rack. b) Place the ipump6400 on its supports and use four anchor screws or bolts and nuts to secure the unit's front brackets to the rack. WARNING The front brackets must be secured to the rack. If front brackets are left unsecured, the unit may shift forward and fall from the rack during installation or operation. Failure to secure the front brackets may result in personal injury and/or damage to the equipment. WARNING Locate the ipump6400 and its cables to avoid impacts, spills, and pulling cables and to ensure sufficient air flow. Failure to locate the ipump6400 in a proper environment may result in damage to the equipment. wegener.com 21 800009-01 Rev. B

2.3 ipump6400 Connections Before applying power, make the following connections to your ipump6400 (refer to Table 4 on page 23 for connector details and to Figure 2.1 ipump6400 Rear-panel Connector Locations for placement): a) Connect the L-band output from your antenna's LNB or from your multiswitch to the extender cable on your ipump6400's input RF port [a]. (A BNC connector is used here for ipump6400s with the ASI input option.) b) Connect a suitable audio monitor or monitors to the ipump6400's audio port(s) [b1] (on both decoders if your ipump6400 includes a second decoder). Also connect audio monitoring to the auxiliary audio port [b2] if your ipump6400 includes that option (See Table 1: ipump6400 Options Key on page 12). NOTE: See Optional Decoder with Digital Output on page 25 for an illustration and audio/video connector details if your ipump6400 is equipped with an optional decoder with digital outputs. c) Connect a suitable video monitor or monitors to the ipump6400's video port [c] (on both decoders if your ipump6400 includes a second decoder). (See Table 1: ipump6400 Options Key on page 12). d) Connect your LAN line to the ipump6400's Ethernet port [d]. (Refer to Table 6: ipump6400 LAN Connector Pin Functions on page 24.) Figure 2.1 ipump6400 Rear-panel Connector Locations e) If desired, connect the Alarm port [e] to your equipment to provide contact closures and openings during alarms or on command from Compel. (Refer to Table 5: ipump6400 Alarm Connector Pin Functions on page 24.) 800009-01 Rev. B 22 wegener.com

f) Finally, connect the supplied ac power cord to the ipump6400's IEC receptacle [f] and to a 100-to-120 Vac or 200-to-240 Vac source. NOTE: Do not connect devices to the mouse, keyboard and other connectors not described here. They are for factory use only. Table 4: ipump6400 Connector Details Designation Connector Type Signal Description Additional Information RF IN female Type F 950 to 2150 MHz RF carrier from antenna LNB A extension cable is shipped already attached to the RF IN port to allow easier access for attaching your RF input. ASI IN female BNC ASI input signal Only on ipump6400s with the ASI input option. AUDIO* 1/8-inch stereo jack Audio output A 1/8-to-RCA adapter is shipped with your ipump6400 (one for each active audio decoder). AUX AUDIO 1/8-inch stereo jack Audio output Can be "slaved" to decoder 1 or decoder 2 VIDEO* Mini-DIN4 or BNC Video output A Mini-DIN4-to-RCA adapter is shipped with your ipump6400. Units equipped with the optional, professional 4:2:2 decoders will have a female BNC connector. LAN female RJ-45 10/100baseT Ethernet Autosensing; see pinout detail intable 6: ipump6400 LAN Connector Pin Functions on page 24 CONTACT CLOSURE/ ALARM male DB-9 Contact closure/opening in and out See pinout detail intable 5: ipump6400 Alarm Connector Pin Functions on page 24 POWER Male IEC receptacle 100-to-120 Vac @60 Hz or 200-to-240 Vac @ 50 Hz Autoswitching * See connector details under Optional Decoder with Digital Output on page 25 if your ipump6400 is equipped with a digital output decoder. Alarm Connector Details The DB-9 female alarm connector on the rear panel provides contact closures and openings during alarm conditions as well as a user relay available for control by Compel command (USER CC). Normal conditions represent the contact in normally functioning, powered operation. Other conditions or commands will reverse the status of the contact from its normal position. wegener.com 23 800009-01 Rev. B

Pin functions of the DB-9 alarm connector are listed in Table 5 below. Table 5: ipump6400 Alarm Connector Pin Functions Pin Number Function 1 Alarm common 2 Alarm Normally Open 3 Contact Closure Out Common 4 No Connection 5 Contact Closure Input 6 Alarm Normally Closed 7 No Connection 8 Contact Closure Out Normally Open 9 Ground Pins 1 and 2 are normally open and are closed during an ipump6400 alarm. Pins 1 and 6 are normally closed and are open during an ipump6400 alarm. Pins 3 and 8 on the DB-9 are normally open and may be closed by command from Compel. Pin 5 is the local, user input (0=trigger). Ethernet/ LAN Port Details The ipump6400's 10/100baseT (autosensing) Ethernet port has the following pin functions: Table 6: ipump6400 LAN Connector Pin Functions Pin Number Name Description 1 TX_D1+ Transmit Data+ 2 TX_D1- Transmit Data- 3 RX_D2+ Receive Data+ 4 Unused 5 Unused 6 RX_D2- Receive Data- 7 Unused 8 Unused 800009-01 Rev. B 24 wegener.com

Optional Decoder with Digital Output Connector details are somewhat different for ipump6400s having the optional decoder with digital audio and video output. Figure 2.2 below illustrates the rear-panel layout of this optional decoder. Connector details are listed in Table 7. Figure 2.2 Digital Output Decoder Connector Layout Table 7: Digital Output Decoder Connectors Ref Number Connector Type Signal Description 1 BNC Serial Digital Video Out 2 BNC Composite Video Out 3 Mini-DIN4 S-Video Out 4 1/8-inch Audio Jack Unbalanced Stereo Audio Out 5 Tini Q-G Mini Balanced Analog Audio and AES/EBU Digital Audio Out wegener.com 25 800009-01 Rev. B

Pinout details for the balanced analog and AES/EBU digital audio connector are shown in Figure 2.3 and Table 8 below. Figure 2.3 Balanced Analog and AES/EBU Digital Audio Connector Table 8: Balanced Analog and AES/EBU Digital Audio Connector Pin Functions Pin Number Function 1 Digital (AES3) + 2 Digital (AES3) - 3 Balanced Right - 4 Balanced Left - 5 Balanced Left + 6 Balanced Right + 800009-01 Rev. B 26 wegener.com

Multiswitch Connection Details When operating a multiswitch, use Table 9 to identify the line signals corresponding to each ipump6400 RF port selection. On a typical multiswitch (as in Figure 2.4 below), these ports will be in order from left to right as viewed from the side holding the input connectors. Table 9: RF Port Selection Signals Port Number Signal 1 13V with 22 khz tone 2 18V with 22 khz tone 3 13V without tone 4 18V without tone Figure 2.4 Typical RF Multiswitch wegener.com 27 800009-01 Rev. B

This page intentionally blank 800009-01 Rev. B 28 wegener.com

Chapter 3 Operation 3.1 Operation Overview Most routine ipump6400 operations are performed over the Compel network or locally through the web-browser interface. However, front-panel control is required to switch the unit s software (see 3.7 Unit Software Switch) or to change some key unit settings such as IP address, unit label, LNB LO value, and alarm/warning thresholds. It is important to remember that while most operations will be performed remotely, the ipump6400 does not prioritize incoming commands based on which interface is used. The ipump6400 treats commands from the front panel with importance equal to commands from both the Compel network and the browser interface. Commands are prioritized based only on the order in which they are received. The first command received is the first one performed. (Of course, when local control is disabled by command from Compel, no local control is possible until re-enabled by Compel.) In addition to introducing and describing the front-panel and web browser interfaces, this chapter provides details on startup/shutdown of your ipump6400, making initial unit settings for basic operation, and performing tasks over the web browser interface. The chapter is organized into the following sections: 3.2 Front-panel Controls and Indicators, 3.3 Startup/Shutdown Procedures, 3.4 Front-panel Operation, 3.5 Initial Unit Setup, 3.6 ipump6400 Operations by Function, and 3.7 Unit Software Switch. NOTE: When operated as part of a Compel Network, your ipump6400 may at times become unavailable for local control or may perform functions not commanded locally. For example, the Compel network operator may command remote ipump6400s to disable local control during a particular broadcast or program schedule. Also, if set up to expect Compel commands, your ipump6400 may begin searching RF channels for a Compel signal if that signal is temporarily lost. wegener.com 29 800009-01 Rev. B

3.2 Front-panel Controls and Indicators There are three major parts of your ipump6400's front-panel controls and indicators: the liquid-crystal display (LCD), the six push buttons, and the eight LED indicators. Figure 3.1 ipump6400 Front Panel Liquidcrystal Display(LCD) Push buttons The ipump6400's LCD indicates unit status and prompts for and reflects user input. Here, you will see your ipump6400's unit label and serial number displayed on the top line following startup. The home screen also alternately displays the input signal s frequency, data rate, and FEC ratio in the lower left corner and continuously displays the current signal-to-noise ratio in the lower right. Using the adjacent push buttons (described in the next paragraph), you can navigate the ipump6400's various screens and edit input fields. These six push buttons are your means of commanding the ipump6400 from the front panel. The four arrow buttons allow navigation through the menu screens and parameter selection and editing in user-input screens. The ENTER button serves to select menu options (downward navigation), to open userinput fields, or to commit user input to the ipump6400. Also press ENTER to quickly start the unit after a normal shutdown. The Escape (ESC) button allows exit from user-input fields without saving the entry or selection. ESC also provides upward navigation through the menu structure to the home screen. Figure 3.2 Push buttons 800009-01 Rev. B 30 wegener.com

LED Indicators These eight light-emitting diodes (LEDs) provide status information about your ipump6400 and its processes. Table 10 on page 31 provides the meaning of the color and state of each LED. Figure 3.3 LED Indicators Table 10: LED Indicator Descriptions Indicator Label Color and State Meaning CARRIER GREEN constant Receiver is tracking carrier. GREEN slow blink Receiver is not tracking carrier. RECORD GREEN constant ipump6400 is recording a program. Off ipump6400 is not recording. DOWNLOAD GREEN constant ipump6400 is downloading a file via Compel. Off ipump6400 is not downloading. LAN GREEN constant Light network activity over the ipump6400 s LAN interface GREEN slow blink Off Heavy network activity over the ipump6400 s LAN interface ipump6400 observed no packet transfers on the LAN interface during the last 20 seconds. COMPEL GREEN constant ipump6400 has received a COMPEL command within the last two minutes. GREEN fast blink GREEN slow blink Off ipump6400 has been addressed by COMPEL within the last five seconds. ipump6400 is in tracking mode, COMPEL is required, but no COM- PEL command has been received within the last two minutes. COMPEL is not required and not received within the last two minutes; or, ipump6400 is not in tracking mode. wegener.com 31 800009-01 Rev. B

Table 10: LED Indicator Descriptions Indicator Label Color and State Meaning AUTH GREEN constant Current transport stream is protected by conditional access (CA) and ipump6400 is authorized and descrambling. GREEN slow blink Off Current transport stream is protected by conditional access (CA) but ipump6400 is unauthorized. Tracked channel is not scrambled. WARNING* AMBER constant One or more warning conditions exist. Read warning information from front-panel LCD. Off No warning conditions exist. ALARM* RED constant One or more alarm conditions exist. Read alarm message from LCD. Off No alarm condition exists. * Only one alarm or warning condition is displayed at a time on the LCD in place of the normal home screen information. When multiple alarm or warning conditions exist, those conditions are displayed in the order of importance. The most critical condition is displayed first. Further alarms or warnings will be shown after the more critical item(s) is cleared. 800009-01 Rev. B 32 wegener.com

3.3 Startup/Shutdown Procedures The first time you start the ipump6400, the boot-up process and some initial setup may require a few minutes to complete. (See Initial Unit Settings.) After the initial startup, and if a normal shutdown was performed, the ipump6400 may be started again simply by pressing the ENTER button on the unit s front panel. Initial startup a) For initial startup, set the power switch to the On position ( I ) and press and hold the ENTER button for two seconds. The ipump6400 will power up and begin the boot process. Usually within three minutes, the unit will complete its initialization (all outputs are muted during this time). b) The eight, front-panel LEDs flash on and off together once and then three more times in succession. The LCD shows the current firmware version and the message, "Booting, please wait....". The expanding and contracting ellipsis shows that the ipump6400 is booting the software. (Note that the version number shown is that of the front-panel firmware only and does not indicate the current version of the application software.) c) During bootup, a quick check of the file system is made to detect and fix any corrupted files. The message "Auto Maintenance..." indicates that this check is in process. The duration of the file system check depends on the extent of any needed repairs to the file system and the size of the affected files. When no problems are detected, the "Auto Maintenance" message will only briefly flash on the LCD. If the file system is corrupt beyond repair, the message, "Filesystem is corrupt..." will appear. Otherwise, the auto maintenance process is continuing normally and you should wait for it to complete. d) Following a normal check of the file system, the message, "Continuing to boot..." is displayed. At completion of bootup, the LEDs will light individually as appropriate to show unit and signal status (see Table 10: LED Indicator Descriptions on page 31). The display then becomes "live" and will typically indicate a loss-of-carrier alarm condition if the unit s RF configuration has not been completed. This is normal and simply means that the RF settings must be adjusted. After the RF setup has been completed, subsequent startups will finish by displaying the home screen (showing the unit's serial number, E b /N 0, and alternately displaying FEC ratio, signal frequency, and data transport rate). This indicates that your ipump6400 is functioning normally and is ready for use. Normal Startup Following initial startup and after a normal shutdown has been performed, the ipump6400 s normal startup may be performed quickly by simply pressing the ENTER button on the front panel. If the receiver is tracking a carrier signal, the green CARRIER LED will light. If the RF set up has not been performed or the receiver cannot track the carrier, the red Alarm LED will light. wegener.com 33 800009-01 Rev. B

Web Browser Operations Startup For HTML control and status checking from a web browser, first navigate from the home screen to the IP Setup screen. (ipump6400 operations performed via a web browser are described under 3.6 ipump6400 Operations by Function.) Step Press Displayed Screen Type a) UNIT SETUP Menu b) ENTER RECORD AND PLAY Menu c) DECODER SETUP Menu d) AUDIO SETUP Menu e) IP SETUP Menu Press ENTER and take note of the ipump6400's IP address displayed on the screen. Then use the following steps to gain control from your web browser: NOTE: It may be necessary to set the IP address, subnet mask, and gateway to specific values - consult your local network administrator. Include leading zeros in addresses entered from the ipump6400 front panel, but not when entering them from the browser interface. a) Open a current-version internet browser from a computer on the LAN attached to your ipump6400. b) In the browser's address field, enter the IP address noted from the IP Address screen and the Status tab of the ipump6400 web interface will appear. 800009-01 Rev. B 34 wegener.com

Figure 3.4 ipump6400 Web Interface (Status Tab) NOTE: For IP addresses which include subfields with leading zeros, you must omit those zeros when entering the address in your browser. For example, IP address 128.092.050.004 (as entered from the ipump6400 front panel) must be entered as 128.92.50.4 in the web browser. Normal Shutdown Removing power to shut down your ipump6400 will not harm the unit, but is not recommended and will lengthen the time required for the next startup. Normal startup can only be performed following a normal shutdown. To shut down your ipump6400: a) Return to the ipump6400 home screen (press ESC repeatedly until model and unit number or an alarm or warning message is displayed) b) Press the right-arrow button four times to reach the Unit Shutdown screen. c) Press the ENTER button to select Unit Shutdown and when prompted, press the ENTER button again to confirm. In less than 30 seconds, the ipump6400 will power down and the LCD and LEDs will go out. Your ipump6400 is now ready for normal startup by pressing the ENTER button. wegener.com 35 800009-01 Rev. B

3.4 Front-panel Operation Operate the ipump6400 from the front panel using the push buttons and LCD. Menu screens on the LCD direct you to screens that control various operating parameters or display information about the ipump6400. Menu titles represent either a category of control (such as Unit Setup, Record and Play, and RF Setup) or the name or category of parameters or information to be displayed (such as RF Status, Active Recordings, or Navigation Help). LCD Menu Navigation Refer to Figure 3.5 which illustrates the complete LCD menu structure. Information and user-input screens beneath these menus are described later. Press the right and left arrow buttons to move between menu screens on the same level (represented in the illustration by arrows connecting the left and right sides of the boxes). When you reach the last menu of a particular level, pressing the right arrow button again will move you back to the first menu of that level. Press the ENTER button to move down to the next level of the menu structure (represented in the illustration by arrows connecting the top and bottom sides of boxes) or to view the information and user-input screens within a particular category. Press the ESC button to move up a level or to the first menu of the current level. Pressing the ESC button repeatedly will always return you to the Home Screen. Figure 3.5 LCD Menu Structure 800009-01 Rev. B 36 wegener.com

User input screens below the menus shown here allow control of such items as Program Number to Record, File to Record to, Decoder Number to Play File to, and others. There are two types of user-input screens - those with an editable field and those with a selectable field. Editable Fields User-input screens with editable fields accept data entry by the user. Shown here is an example of a user-input screen with an editable field. Figure 3.6 Editable Field To make changes to the data in the field: a) Press ENTER to open the field. The first character location of the field is highlighted. b) Press the up or down arrow buttons to increment that digit or letter until the desired value is displayed. Press the right arrow button to move to the next digit or location in the field and change it the same way. Continue until all digits or letters are displayed correctly. c) Press the ENTER button to save your changes. Pressing ESC before pressing ENTER will cancel any changes. Another type of editable field appears when filenames must be entered. These fields have the following appearance: Figure 3.7 Filename Field a) Press ENTER to begin spelling the filename. The letter A in the character list is highlighted. b) Press the arrow buttons to move through the character list until the first character of the filename is highlighted. (Additional characters including numerals, decimal, space, and hyphen appear on the LCD as you move downward through the available characters list.) wegener.com 37 800009-01 Rev. B

c) Press ENTER to confirm the first character. The first character is displayed at the bottom left of the LCD. d) Select additional characters as in steps b) and c) until the entire filename is displayed completely at the bottom left of the LCD. e) When the entire filename is shown, press ESC to stop editing. When prompted, "Done?", press ENTER if the filename is correct or ESC to continue editing your entry. Selectable Fields Other user-input screens allow choosing from a list of options. Here is an example of a user-input screen with a selectable field. Figure 3.8 Selectable Field When you reach the screen, the current selection is displayed. To change your selection: a) Press ENTER to open the field. The current selection is highlighted. b) Press the up or down arrow buttons to view available options one at a time. c) When the desired option is shown, press the ENTER button to save that selection. Pressing ESC before pressing ENTER will cancel any change. NOTE: Front-panel control is limited by a four-minute timeout period. After four minutes without input from the front-panel push buttons, the ipump6400 LCD will automatically return to the home screen and any unsaved changes will be lost. 800009-01 Rev. B 38 wegener.com

3.5 Initial Unit Setup Some of the ipump6400 s settings are preconfigured or should be configured during the ipump6400's initial setup and are not likely to require adjustment on a regular basis. RF current channel, LNB type, LNB DC power, date and time, and unit label settings should be made at this time. Initial RF setup A few of the RF settings are preconfigured and should only be changed if advised by your satellite operator. These include the LNB LO value, SNR Alarm Threshold, and SNR Margin Warning settings. The table below lists these settings as they are configured on your ipump6400 when it is delivered from the factory. Table 11: ipump6400 Preconfigured RF Settings Parameter LNB LO Value (appropriate for Ku-band reception - 5150 MHz would be an appropriate setting for C-band operation) SNR Alarm Threshold (signal-to-noise ratios below this value will result in an alarm condition) SNR Margin Warning (warning condition triggered when signal-tonoise ratio is within 3.0 db of the SNR Alarm Threshold - under 8.0 db as preset) Preset Value 10750 MHz 5.0 db 3.0 db Current Channel Setup Navigate to the RF Setup screen. Step Press Displayed Screen Type a) UNIT SETUP Menu b) ENTER RECORD AND PLAY Menu wegener.com 39 800009-01 Rev. B

Step Press Displayed Screen Type c) DECODER SETUP Menu d) AUDIO SETUP Menu e) IP SETUP Menu f) RF SETUP Menu From RF Setup, adjust the Current Channel settings. Step Press Displayed/Field Details Screen Type a) ENTER RF STATUS: TRACKING: Eb/No = XX.X Data Display RF status is shown. If tracking, then Eb/N0 is also displayed. b) CURRENT CHANNEL Menu c) ENTER RF-INPUT PORT: 1 User Input - Selectable This screen only appears when LNB type is set to Multiswitch. If shown, select port 1, 2, 3, or 4. d) DOWNLINK FREQUENCY: XXXXX.XX MHz User Input - Editable Enter downlink frequency from the LNB local oscillator in megahertz. 800009-01 Rev. B 40 wegener.com

Step Press Displayed/Field Details Screen Type e) TRANSP. DATA RATE: XXX.XX Mbps User Input - Editable Enter transport stream data rate in megabits per second. f) RF-MOD/FEC RATIO: QPSK 3/4 User Input - Selectable RF modulation is QPSK. Available forward error correction ratios are 1/2, 2/3, 3/4, 5/6, and 7/8. g) PROGRAM NUMBER: 00001 User Input - Editable Enter the number or code of program to select from stream. h) TAG SITE: <Unused> Values entered in this field will not affect ipump6400 operation. i) SAVE ALL CHANGES? YES<ENT> NO<ESC> User Input - Selectable Press ENTER to save or ESC to cancel all RF Setup changes and return to the Current Channel screen. LNB Type Selection Navigate to the RF Setup screen. Step Press Displayed Screen Type a) UNIT SETUP Menu b) ENTER RECORD AND PLAY Menu c) DECODER SETUP Menu d) AUDIO SETUP Menu wegener.com 41 800009-01 Rev. B

Step Press Displayed Screen Type e) IP SETUP Menu f) RF SETUP Menu From RF Setup, select the LNB type. Step Press Displayed/Field Details Screen Type a) ENTER RF STATUS: TRACKING: Eb/No = XX.X Data Display RF status is shown. If tracking, then Eb/N0 is also displayed. b) CURRENT CHANNEL Menu c) LNB TYPE User Input - Selectable Available LNB types are Multiswitch, Universal./Astra, and Local Oscillator. Note that for proper multiswitch operation, LNB DC Power must be set to ON. LNB DC Power Setting LNB DC Power must be set ON for proper multiswitch operation. First, navigate to the RF Setup screen. Step Press Displayed Screen Type a) UNIT SETUP Menu b) ENTER RECORD AND PLAY Menu c) DECODER SETUP Menu 800009-01 Rev. B 42 wegener.com

Step Press Displayed Screen Type d) AUDIO SETUP Menu e) IP SETUP Menu f) RF SETUP Menu From RF Setup, set the LNB DC Power. Step Press Displayed/Field Details Screen Type a) ENTER RF STATUS: TRACKING: Eb/No = XX.X Data Display RF status is shown. If tracking, then Eb/N0 is also displayed. b) CURRENT CHANNEL Menu c) LNB TYPE User Input - Selectable d) LNB DC POWER User Input - Selectable Select ON or OFF. Date/Time Setup NOTE: When operating under the Compel network, date and time settings are overwritten by Compel. Time zone and Daylight Savings Time settings, however, remain under local control and should be set by the user. Set up the date and time for your ipump6400 during the initial setup. First navigate to the Date/Time Setup screen. (Date/Time setup may also be performed from the browser interface under the SETUP tab.) wegener.com 43 800009-01 Rev. B

From Date/Time Setup, adjust the current date, time, offset from GMT, and daylight saving time settings as follows: Step Press Displayed/Field Details a) ENTER CURRENT DATE YYYY/MM/DD Screen Type User Input - Editable Enter current date in year/month/day format. b) CURRENT TIME HH:MM:SS User Input - Editable Enter current time in hours:minutes:seconds format. c) OFFSET FROM GMT GMT -5 (EST/EDT) User Input -Selectable Select the appropriate offset from Greenwich Mean Time (GMT). Offset selections range from GMT -12 to GMT +11. (Eastern U.S. is at GMT -5; West Coast U.S. is at GMT -8.) d) DAYLIGHT SAVING TIME OBSERVED? YES User Input -Selectable Select Yes if daylight saving time is observed in your area or No if it is not. 800009-01 Rev. B 44 wegener.com

Unit Label Setup Set the unit label (or name of your ipump6400) during the initial setup. First navigate to the Set Unit Label screen. From Set Unit Label, enter a name for your ipump6400 as follows: Step Press Displayed/Field Details a) ENTER U. LABEL ABCDEFGHI JKLMNOPQR Press ENTER to begin spelling the unit label. Press the arrow buttons to select the first character. (Additional characters including numerals, decimal, space, and hyphen appear as you move downward through the available characters.) Press ENTER to confirm the first character. Select additional characters in the same fashion until the unit label is displayed completely at the bottom left of the LCD. b) ESC Done? [Yes] [No-Esc} Screen Type User Input - Editable User Input - Selectable Press ENTER to confirm the unit label or ESC to return to the U. Label screen. wegener.com 45 800009-01 Rev. B

3.6 ipump6400 Operations by Function Most ipump6400 functions can be performed locally from either the front panel or from a web browser attached to the ipump6400 via Ethernet. However, web browser operation is described in this section because after initial configuration, that is the method by which most local operations will be performed. Operations are listed and described by function. Monitor ipump6400 Status Monitor ipump6400 status as follows: a) Enter the ipump6400's IP address in the address bar of your web browser. b) The ipump6400 Status tab is automatically displayed. The unit s serial number, current software version, and model number are shown. Receiver mode, signal-to-noise ratio, decoder states and settings, packet counts, and record activities are also displayed and refreshed every few seconds. 800009-01 Rev. B 46 wegener.com

Live Program Play When set up for live program play, the ipump6400 decodes an incoming MPEG stream from the received DVB satellite signal and decrypts and decodes the audio and/or video from the selected program to the connected audio and video monitors. Two live programs from the same DVB carrier may be played simultaneously if your ipump6400 has the optional second decoder. a) To set up for live program play, first ensure the appropriate RF input and audio and/or video output connections have been made. b) Next, ensure that the proper RF settings have been selected. Check that downlink frequency, transport data rate, FEC ratio, and program number are properly selected before playing a live program. NOTE: The LNB LO frequency may only be set from the front panel. In typical operation, changes to this setting are not usually necessary after initial unit setup. c) From your web browser, click the Setup tab to display the various ipump6400 settings. (The Aux Audio settings only appear for units equipped with the Aux Audio option.) wegener.com 47 800009-01 Rev. B

d) Next, click the Edit button under Satellite Receive Settings to change that group s parameters. e) After changing the fields as needed, click the Activate button to save your changes. Any changes will take effect immediately. f) If you do not wish to make or save any changes, click the Cancel button and any changes will be discarded. g) Next, click the Edit button under Settings for Decoder #1 (or #2 if available and desired). h) Choose a specific DVB program, an IP multicast program, Follow Tune, or Off from the Setting pull-down menu. The Follow Tune setting causes the decoder to play whatever DVB program is selected under Satellite Receive Settings. Audio and video mute options, plus UDP port and multicast address if multicast is chosen, may also be selected from this screen. If you don't wish to keep your changes, click the Cancel button. Otherwise, click the Activate button to make your changes immediately effective and begin playing the selected program. 800009-01 Rev. B 48 wegener.com

NOTE: The setting at initial startup is Follow Tune. To stop live program playing, select Off under Decoder Settings. i) Next (if the Aux Audio option is enabled), click the Edit button under Settings for Aux Audio to change that group s parameters and provide an extra audio-only service through the auxiliary audio port. j) Choose a specific DVB program, an IP multicast program, Follow Tune, Follow Decoder 1 (or 2), or Off from the Setting pull-down menu. The Follow Tune setting causes the decoder to play the audio from whatever DVB program is selected under Satellite Receive Settings. For IP multicast programs, also set the UDP port and multicast address. The first audio content detected in that stream is used. When Aux Audio is set to Follow Decoder 1 (or 2), it uses the same program to which the followed decoder is set and a language descriptor (from the Language setting) is used to find a matching audio stream within that program. The Language may be the same as, or different from, the primary audio output of the followed decoder. If First Available is chosen as the Language setting when Aux Audio is set to Follow Decoder, the next unused available audio is played. Consider the example of a program that contains a first audio ENG and a secondary audio FRE and the followed decoder s language descriptor is set to ENG. If the Aux Audio is set to ENG, then both will produce the audio tagged as ENG. Likewise, if the followed decoder is set to First Available and the Aux Audio is set to ENG they will both produce ENG. However, if the followed decoder is producing ENG and the Aux Audio is set to First Available, the Aux Audio will produce FRE because ENG is already being produced by an audio port for the followed decoder. If Aux Audio is set to Follow Decoder 1 (or 2) and a normal file play action takes place on the followed decoder, then the Aux Audio port will be silent for the duration of the file play. However, if the file was recorded using the All Audio option, then during playback to an A/V decoder, any audio within the file with a matching language descriptor will be sent to the Aux Audio port during file playback. NOTE: A file may only be played back through the Aux Audio port if Aux Audio is not set to Follow Decoder 1 or 2. The single audio stream in the file is extracted and played (regardless of the Aux Audio Language setting), and the associated video is discarded. Also choose the desired mute option (Muted or Unmuted) for Audio Left and Audio Right. If you don't wish to keep your changes, click the Cancel button. Otherwise, click the Activate button to make your changes immediately effective and begin playing the selected program. wegener.com 49 800009-01 Rev. B

Record Program to File The ipump6400 can record incoming programs to stored files for later playback. Up to three separate programs may be recorded at one time. NOTE: Record and Play settings are volatile through power cycles. Except for the Loop Forever playlist setting, these settings will be lost when the ipump6400 is rebooted. If Loop Forever is selected, then the playlist chosen to loop forever will begin playing when the ipump6400 returns to service after a reboot. a) To set up the ipump6400 for program recording, first ensure the appropriate RF input settings have been selected. b) Click the Rec/Play tab from your web browser interface. c) Under Record, in the Filename: box, enter a name for the file you wish to record. File names are limited to 16 characters. Upper and lower case letters, numerals, decimals and spaces are allowed, but leading or following spaces will be truncated (the file name may not begin or end with a space or spaces). NOTE: Users should avoid accidentally overwriting an existing file. The ipump6400 front panel will display a warning message before the Record function overwrites an existing file with the same name but will not prevent overwriting. 800009-01 Rev. B 50 wegener.com

d) Next enter a time in the Length of Recording boxes. Enter the duration of time to record in hours, minutes, seconds (HH:MM:SS), and tenths of a second. Enter a duration slightly longer than the expected program length to ensure that you record the entire program. To record for an indefinite period, enter zero time. The ipump6400 will continue to record until commanded to stop or until available disk space is consumed. NOTE: If the storage capacity is filled over 99% during recording, the ipump6400 begins deleting existing files in chronological order beginning with the oldest file. The current recording will not be interrupted unless all deletable files have been deleted and remaining storage capacity remains under 1%. e) If the program is classical MPEG, click the appropriate radio button to select a Single Audio program or All Audio and choose a program from the dropdown list. f) Otherwise, if the program is MPEG within IP, click the IP Program radio button and enter the IP multicast address and port number corresponding to the desired stream. g) Click the Record button to begin recording the selected program. NOTE: To stop recording before the end of the entered length of recording, click the "Stop" hyperlink for the appropriate file on the Record/Play chart. Play Recorded Program File Use the following steps to play a recorded or previously downloaded program file: a) Click the Rec/Play tab from your web browser interface. b) Select a file or playlist to play by clicking its name under the File Playback list. The name of the current directory is shown just above the list of files. When displayed, you may double click [-Previous Directory-] to view file names in the next higher directory. Or, double click any selection displayed in red text inside square brackets (such as [directoryname] ) to move down to that directory level. c) If selecting a playlist, you may also click one of the three radio buttons to either Loop on Last (repeating the last program until stopped by the user), Loop Forever (repeating the entire sequence until stopped by user), or Loop N Times (repeating the entire sequence N times). NOTE: The Rec/Play tab initially displays the contents of the /recorded directory, but the user may also record to or play from files in other directories. wegener.com 51 800009-01 Rev. B

d) Click the Play to Decoder 1 or Play to Decoder 2 button to immediately begin playing the program or playlist through the desired decoder. (Play to Decoder 2 will only appear for dual-decoder ipump6400s.) The Record/Play chart on the left will display the name and time remaining of the selected program or playlist. e) To stop playing a program or playlist before it has played completely, click the "Stop" hyperlink under the Record/Play chart. File Management View, delete, and rename files using the following procedure: a) Click the Files tab from your web browser interface. b) Select a file by clicking on its filename under the File Manager list (file size in bytes is shown adjacent to each filename). The name of the current directory is shown just above the list of files. When displayed, you may double click [-Previous Directory-] to view file names in the next higher directory. Or, double click any selection displayed in red text inside square brackets (such as [directoryname] ) to move down to that directory level. c) To view a file, click the View File button or double-click the filename to open/play the file on your screen. The file will be opened by the application indicated by the extension on the filename (Windows Media Player for MPG files, Microsoft Word for DOC files, for example). d) To delete the selected file, simply click the Delete File button. 800009-01 Rev. B 52 wegener.com

e) To rename the file, first type the new name in the Rename To: box. As with recording new files, file names are limited to 16 characters. Upper and lower case letters, numerals, decimals and spaces are allowed, but leading or following spaces will be truncated (the file name may not begin or end with a space or spaces). After completing the filename, press the Rename To: button to rename the file. File Streaming and Routing For multicast streaming of stored files, do the following: a) First, click the Streams tab on the web browser interface. b) If streaming from an existing file, select a file from the Streaming Files list. The name of the current directory is shown just above the list of files. When displayed, you may double click [-Previous Directory-] to view file names in the next higher directory. Or, double click any selection displayed in red text inside square brackets (such as [directoryname] ) to move down to that directory level. NOTE: A file streamed to a destination already receiving a live stream will supersede the live stream until the file stream has stopped. The live stream, in progress, will then continue. wegener.com 53 800009-01 Rev. B

c) If streaming live from a "classical" DVB program, select the program to stream from the Program/Language pull-down list under Stream Live Program. d) Click inside the Multicast Destination: box and type the appropriate IP address. Also enter the UDP Port number in the UDP Port: box. e) When the address information and selected file or stream information are correct, click the Start File Stream: or Start Live Stream: button respectively to begin streaming. f) Stop file streaming by highlighting the desired stream from the Stream Status list and clicking the Stop button. Scheduled Operation From the web browser interface, you can view schedules of record and play operations set up by the Compel network for the ipump6400 by clicking the Schedule tab. If needed, you can click the Disable button to temporarily suspend scheduled operations. Click Enable to return to scheduled operations. The ipump6400 will resume performing operations according to the scheduled times. Operations scheduled for times during which the unit is "disabled" will not be performed. 800009-01 Rev. B 54 wegener.com

Playlist Management With ipump6400 playlists, you can set up and play a stored sequence of programs without interruption. (Playlists are stored in nonvolatile memory such that they remain available after unit reboots.) Create or edit playlists from the web interface using the following procedure: a) Click the Playlist tab from your web browser interface b) To create a new playlist, first click the Create Playlist button. wegener.com 55 800009-01 Rev. B

c) A playlist number will appear. If desired, type a name in the Playlist Name box and click the Rename button. This name (rather than the number) will appear in the list of existing playlists. d) Next select the programs to include in the playlist. Programs may be selected one at a time (click the filename of the desired program) from the Directories box and added to the Spots in Playlist by clicking the left-arrow button. Double click directory names (displayed in red text) to browse other directories. Multiple files may be highlighted at one time by using control-click to select individual files and shift-click to select multiple adjacent files. Again, clicking the left-arrow button adds all highlighted programs to the playlist. NOTE: When a playlist is chosen for file playback, programs will be played in the order that they appear in the playlist. e) To edit an existing playlist, first select it from the Edit Existing Playlist dropdown. f) Files are removed from the playlist by highlighting using the same click, control-click, and shift-click methods followed by clicking the Remove From List button. All spots may be removed from the playlist by clicking the Clear List button. g) Add files to the list in the same manner as when creating a new playlist. If desired, a program may be inserted in the middle of a list. Do this by first highlighting a spot in the playlist before which the new program should appear. Then add the new program as before. The added file will be inserted before the highlighted playlist spot. NOTE: RANDOM and SEQUENTIAL are default "files" which may be added to any playlist. When RANDOM is selected, the ipump6400 randomly selects a file to play from the selected directory. When SEQUENTIAL is selected, the ipump6400 plays the first file in the selected directory that has not already been played as SEQUENTIAL. Or, if all files in the selected directory have been played as SEQUENTIAL, then SEQUENTIAL will again play the first file. For example, if the selected directory contains the files A, B, C, and D (in that order), then the first time SEQUENTIAL appears in the playlist, file A will be played. The second, third, and fourth times SEQUENTIAL appears in the playlist, the files B, C, and D will be played respectively. If SEQUENTIAL appears in the playlist a fifth time, then file A will be played again and so forth. The file played by the SEQUENTIAL entry is dependent only on the order of files played as SEQUENTIAL and is not affected by any other previous playlist entries. 800009-01 Rev. B 56 wegener.com

NOTE: To provide a course of action for the ipump6400 in case of a "loss of service" (RF signal drops below a minimum threshold or the feed is lost entirely), a playlist named LOS may be created. The ipump6400 will begin playing this playlist immediately when a "loss of service" condition arises. When the signal is regained, the ipump6400 will return to the live feed it was originally playing. ipump6400 Help Access help in the form of an online manual and a list of questions and answers by clicking the HELP tab from your web browser. wegener.com 57 800009-01 Rev. B