Proposed reference equalizer change in Clause 124 (TDECQ/SECQ. methodologies).

Similar documents
On Figure of Merit in PAM4 Optical Transmitter Evaluation, Particularly TDECQ

TDECQ update noise treatment and equalizer optimization (revision of king_3bs_01_0117) 14th February 2017 P802.3bs SMF ad hoc Jonathan King, Finisar

802.3cd (comments #i-79-81).

Component BW requirement of 56Gbaud Modulations for 400GbE 2 & 10km PMD

SECQ Test Method and Calibration Improvements

Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

DataCom: Practical PAM4 Test Methods for Electrical CDAUI8/VSR-PAM4, Optical 400G-BASE LR8/FR8/DR4

PAM4 signals for 400 Gbps: acquisition for measurement and signal processing

50 Gb/s per lane MMF objectives. IEEE 50G & NGOATH Study Group January 2016, Atlanta, GA Jonathan King, Finisar

100G-FR and 100G-LR Technical Specifications

40G SWDM4 MSA Technical Specifications Optical Specifications

40G SWDM4 MSA Technical Specifications Optical Specifications

Refining TDECQ. Piers Dawe Mellanox

The Challenges of Measuring PAM4 Signals

400G-FR4 Technical Specification

100G EDR and QSFP+ Cable Test Solutions

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

M809256PA OIF-CEI CEI-56G Pre-Compliance Receiver Test Application

Further Investigation of Bit Multiplexing in 400GbE PMA

Further information on PAM4 error performance and power budget considerations

Development of an oscilloscope based TDP metric

100G SR4 TxVEC - TDP Update (D2.1 comment 94) John Petrilla: Avago Technologies March 2014

64G Fibre Channel strawman update. 6 th Dec 2016, rv1 Jonathan King, Finisar

Development of an oscilloscope based TDP metric

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

PAM8 Baseline Proposal

Technical Feasibility of Single Wavelength 400GbE 2km &10km application

Improving the Performance of Advanced Modulation Scheme. Yoshiaki Sone NTT IEEE802.3bs 400 Gb/s Ethernet Task Force, San Antonio, Novenver 2014.

Optical transmission feasibility for 400GbE extended reach PMD. Yoshiaki Sone NTT IEEE802.3 Industry Connections NG-ECDC Ad hoc, Whistler, May 2016

Systematic Tx Eye Mask Definition. John Petrilla, Avago Technologies March 2009

Improved extinction ratio specifications. Piers Dawe Mellanox

10GBASE-LRM Interoperability & Technical Feasibility Report

100GBASE-FR2, -LR2 Baseline Proposal

32 G/64 Gbaud Multi Channel PAM4 BERT

Further Clarification of FEC Performance over PAM4 links with Bit-multiplexing

The Case of the Closing Eyes: Is PAM the Answer? Is NRZ dead?

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

InfiniBand Trade Association

CDAUI-8 Chip-to-Module (C2M) System Analysis #3. Ben Smith and Stephane Dallaire, Inphi Corporation IEEE 802.3bs, Bonita Springs, September 2015

Keysight N4917BSCA Optical Receiver Stress Test Solution 400 Gb/s Ethernet - IEEE 802.3bs

Transmitter Preemphasis: An Easier Path to 99% Coverage at 300m?

CDAUI-8 Chip-to-Module (C2M) System Analysis. Stephane Dallaire and Ben Smith, September 2, 2015

Receiver Testing to Third Generation Standards. Jim Dunford, October 2011

N4917BACA Optical Receiver Stress Test Solution 100 Gb/s Ethernet

100GEL C2M Channel Reach Update

100G CWDM Link Model for DM DFB Lasers. John Petrilla: Avago Technologies May 2013

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

TP2 and TP3 Parameter Measurement Test Readiness

N4917CPCA Optical Receiver Stress Test Solution

Thoughts about adaptive transmitter FFE for 802.3ck Chip-to-Module. Adee Ran, Intel Phil Sun, Credo Adam Healey, Broadcom

100Gb/s Single-lane SERDES Discussion. Phil Sun, Credo Semiconductor IEEE New Ethernet Applications Ad Hoc May 24, 2017

50 Gb/s per lane MMF baseline proposals. P802.3cd, Whistler, BC 21 st May 2016 Jonathan King, Finisar Jonathan Ingham, FIT

Comparison of NRZ, PR-2, and PR-4 signaling. Qasim Chaudry Adam Healey Greg Sheets

How advances in digitizer technologies improve measurement accuracy

Transmitter Specifications and COM for 50GBASE-CR Mike Dudek Cavium Tao Hu Cavium cd Ad-hoc 1/10/18.

40GBASE-ER4 optical budget

New Metric Offers More Accurate Estimate of Optical Transmitter s Impact on Multimode Fiber-optic Links

Issues for fair comparison of PAM4 and DMT

FIBRE CHANNEL CONSORTIUM

Updated Considerations on 400Gb/s Ethernet SMF PMDs

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

Brian Holden Kandou Bus, S.A. IEEE GE Study Group September 2, 2013 York, United Kingdom

LOW POWER DIGITAL EQUALIZATION FOR HIGH SPEED SERDES. Masum Hossain University of Alberta

SHF Communication Technologies AG

Simulations of Duobinary and NRZ Over Selected IEEE Channels (Including Jitter and Crosstalk)

A 90 Gb/s 2:1 Multiplexer with 1 Tap FFE in SiGe Technology

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

WWDM Transceiver Update and 1310 nm eye-safety

Ordering information. 40Gb/s QSFP+ ER4 Optical Transceiver Product Specification. Features

Open electrical issues. Piers Dawe Mellanox

Calibrate, Characterize and Emulate Systems Using RFXpress in AWG Series

Proposal for 400GE Optical PMD for 2km SMF Objective based on 4 x 100G PAM4

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

Boosting Performance Oscilloscope Versatility, Scalability

Techniques for Extending Real-Time Oscilloscope Bandwidth

PAM4 Transmitter Analysis

10Gbps SFP+ Optical Transceiver, 10km Reach

100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

DCA Wide-Bandwidth Oscilloscope Family Configuration Guide

Keysight Technologies N1090A, N1092A/B/C/D/E and N1094A/B DCA-M Optical and Electrical Sampling Oscilloscopes

Analyzing GBaud PAM4 Optical and Electrical Signals APPLICATION NOTE

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

100G SR4 TxVEC Review Comment r01-43

Keysight Technologies N4917CPCA Optical Receiver Stress Test Solution for CPRI Fronthaul Networks. Preliminary Data Sheet

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

Reducing input dynamic range of SOA-preamplifier for 100G-EPON upstream

Measurements Results of GBd VCSEL Over OM3 with and without Equalization

BER MEASUREMENT IN THE NOISY CHANNEL

6ch LC duplex QSFP Receiver ROSA (4ch x 6Gbps) + μ-bosa (2.5Gbps) (2km) FVQ2-4R1B-SM2

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

Baseline Proposal for 200 Gb/s Ethernet 40 km SMF 200GBASE-ER4 in 802.3cn

Tektronix Inc. DisplayPort Standard

FSK Transmitter/Receiver Simulation Using AWR VSS

InfiniBand Trade Association

Keysight Technologies ad Waveform Generation & Analysis Testbed, Reference Solution

52Gb/s Chip to Module Channels using zqsfp+ Mike Dudek QLogic Barrett Bartell Qlogic Tom Palkert Molex Scott Sommers Molex 10/23/2014

Features: Compliance: Applications: Warranty: QSFP-40G-LR4-GT 40GBASE-LR4 QSFP+ SMF Module Cisco Compatible

Keysight N1085A PAM-4 Measurement Application For 86100D DCA-X Series Oscilloscopes. Data Sheet

Transcription:

Proposed reference equalizer change in Clause 124 (TDECQ/SECQ methodologies). 25th April 2017 P802.3bs SMF ad hoc Atul Gupta, Macom Marco Mazzini, Cisco

Introduction In mazzini_01a_0317_smf, some concerns about TDECQ/Sensitivity results consistency were shared. In this updated work we ll: Update TDECQ results (fixed noise BW into file s header) with Cisco Lab Tx. Provide feedback from different companies about: TDECQ results with shared Cisco Lab Tx (PRBS11 waveforms). TDECQ (max) challenges with current TX technologies, link consistency. Propose a change in the reference equalizer for TDECQ/SECQ methodologies of Clause 124. We ll also address some of the questions about experiments from the previous ad-hoc. Effects of Phase shift on sensitivity results. TX impulse response. Sensitivity results (shared PRBS20 waveforms).

Cisco Lab Tx: TDECQ versus equalizer and bandwidth. All TDECQ plots show similar trends for varying RX BW (see mazzini_01a_0317_smf and back-up slide 12). Cisco Lab Tx is not compliant to TDECQ with the 5xT/2 equalizer, but is compliant with a 5xT (same complexity) equalizer. Longer equalizers give smaller improvements (<0.5dB) in TDECQ. Equivalent 38.68GHz BW 5T/2 3T 5T 2.5dB TDECQ seems challenging to be achieved by 53GBaud transmitters. These results have been also confirmed by other companies by using FlexDCA. When using their homemade methods to calculate TDECQ, some differences with respect FlexDCA were observed, especially for low BW/short equalizer conditions. m is the relative main tap position (e.g. 5 T/2 m2 is 1pre and 3post)

Cisco Lab Tx: TDECQ versus equalizer type and length Cisco Lab Tx not compliant to TDECQ considering 5xT/2 equalizer, but is compliant for a 5xT equalizer, which is same complexity for DSP developers. Longer equalizers than 5xT give smaller improvements (<0.5dB) on TDECQ. m is the relative main tap position (e.g. 5 T/2 m2 is 1pre and 3post) (41.25GHz BW = 55GHz*0.75 case results)

Comments. Presented updated TDECQ results. From experiments, cross-verifications and discussions we can say: 1. At 53Gbaud, TDECQ < 2.5dB is hard to achieve with < 5xT equalizer. Received same feedback from different sources during and after OFC. (Note: on Cisco s Lab TX, 7x does not provide strong TDECQ improvement). Yet links can work with margin by using 7xT equalizers (see mazzini_01a_0317_smf and back-up). 2. Results using short equalizers (3xT, 5xT/2) are not a stable metric to correlate Rx BER with TDECQ: some convergence issues were exposed. In line with other companies findings and with lecheminant_01_1016_smf (slides 4, 5). As per mazzini_01a_0317_smf, this can cause issues for SECQ calibration. 3. Formally, TDECQ/SECQ signal processing should mimic what's expected for a real receiver (king_04_0217_smf, 2), thus: Multiple DSP-suppliers developing 53GBaud solutions were approached. All of them confirmed that: a) That their ADC will sample at 1 sample per bit. b) That their RX equalizer will be equivalent to a 7xT (or more) T-spaced equalizer, not a T/2-spaced equalizer. 4. There s good correlation between worst case BER/TDECQ using a 5xT-spaced equalizer (mazzini_01a_0317_smf, 4).

Proposed changes for 802.3bs draft 3.2 Into 124.8.5, change: 124.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ) The TDECQ of each lane shall be within the limits given in Table 124 6 if measured using the methods specified in 121.8.5.1, 121.8.5.2, and 121.8.5.3 using a reference equalizer as described in 121.8.5.4, with the following exceptions: The signaling rate of the test pattern generator is as given in Table 124 6. The combination of the O/E converter and the oscilloscope has a fourth-order Bessel-Thomson filter response with a bandwidth of 38.68 GHz. Into: 124.8.5 Transmitter and dispersion eye closure for PAM4 (TDECQ) The TDECQ of each lane shall be within the limits given in Table 124 6 if measured using the methods specified in 121.8.5.1, 121.8.5.2, and 121.8.5.3 with the following exceptions: The signaling rate of the test pattern generator is as given in Table 124 6. The combination of the O/E converter and the oscilloscope has a fourthorder Bessel-Thomson filter response with a bandwidth of 38.68 GHz. The reference equalizer is a 5 tap, T spaced, feed-forward equalizer (FFE), where T is the symbol period. NOTE This reference equalizer is part of the TDECQ test and does not imply any particular receiver equalizer implementation.

Cisco set-up: phase shift impairment and recorded TX IPR. Small impact of the sampling phase over +/-0.05UI (confirmed with post-processing). For this TIA assembly case the optimal sampling phase is 0 UI. Captured waveform can be made available upon request.

Recap of measured BERs with TIA assembly and various equalizers. Left chart showing penalty versus long equalizer chain, as well indicates the equivalent T-spaced receiver that makes sensitivity as the 5 taps T/2 equalizer. T-spaced equalizer provides close to 1dB OMAouter penalty w/respect T/2 cases. Not significant improvement increasing the T- spaced equalizer lenght from 7 to 9 or 11 taps, 5 taps close to floor. 5T/2 is almost equivalent to 9 taps T in terms of sensitivity. These results have been verified independently by others. Depending on the different criterion to optimize the FFE taps, results can converge more towards long equalizer chain or not (we re also investigating sensitivity behavior versus criterion). The usage of longer equalizer chain seems help normalizing results variability across companies, so reducing risks and debug time.

THANK YOU

Back-up

53GBaud PAM 4 TX/RX : sensitivity and TDECQ set-up. MP1821A Mux Anritsu MP1800 Mainframe MP1821A Mux Gated-trigger clock Tektronix DSA8300A with 80C10 optical module FlexDCA Post-processing RF Ampl (SHF M827A) Laser Characteristics: 30GHz (3dB) BW ~ 15 pa/ Hz mazzini_01a_0317_smf 50ohms RF output Keysight DSA-X 96204Q-62GHz (160Gs/s real time) MATLAB Post-processing

Cisco Lab Tx: TDECQ TDECQ of Cisco Lab Tx measured by: 1. PRBS11 waveforms acquisitions with Tektronix sampling scope and 80C10 optical head. Acquistion done using different reference filters (43, 39 and 28Gb/s) and head s optical bandwidth (70, 55 and 32GHz). 2. Acquired waveforms were post- processed using Keysight FlexDCA software and PAM4 analysis tool. Left case showing FlexDCA TDECQ analysis with current IEEE reference equalizer and 70GHz BW on optical head (note: standard requires 38.68GHz, not yet available on scope).

About sampling scope reference RX filter and optical BW relationship. When applying a Reference Receiver Filter" the electrical 3dB bandwidth is set to 0.75x of the bit rate. When selecting an unfiltered Bandwidth setting, the optical 3dB bandwidth is set to the listed number (acquisition done 32GHz, 55GHz, 70GHz). Since optical 3dB bandwidth is equal to the 6dB electrical bandwidth (due to 10*log versus 20*log calculations), and for a Gaussian or 4th-order Bessel- Thompson frequency response roll-off the 3dB frequency point is approximately ~0.75 of the 6dB frequency, this means that effectively an optical (e.g. 55GHz ) bandwidth selection has a 3dB optical (and 6dB electrical) bandwidth of 55GHz and a 3dB electrical bandwidth of roughly 0.75of the optical bandwidth (e.g. ~41.25GHz). In other words the 55GHz bandwidth setting is essentially the same as a 55Gb/s reference receiver filter.