Active UTP Transceiver Hub Installation Guide

Similar documents
Active UTP Transceiver Hub

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Model 1421 Distribution Amplifier

HDBaseT RECEIVER B-540-RX-330-IR INSTALLATION MANUAL

Multi-Channel Passive Transceiver Hubs Installation Sheet

HDBaseT RECEIVER B-520-RX-230-IR INSTALLATION MANUAL

HDBaseT EXTENDER B-540-EXT-230-RS INSTALLATION MANUAL

HDBaseT RECEIVER B-520-RX-330-IR INSTALLATION MANUAL

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

Passive Video Transceivers

Monochrome Video Monitors

OWNER S MANUAL. HDBaseT EXTENDER B-500-EXT-330-RS-IP

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

2.0 Wall Mount TV Soundbar Instruction Manual

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

HD Digital MPEG2 Encoder / QAM Modulator

Utility Amplifier GA6A Model

Color Video Monitor. Instruction Manual. Read this manual thoroughly before use, and retain it for maintenance.

2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234

HD Digital MPEG2 Encoder / QAM Modulator

ARS x4 MATRIX SWITCHER Instruction Manual

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

OWNER S MANUAL HD-2CAT-1080P-130. Binary 2CAT Extender WELCOME TO THE BINARY BRAND OF PRODUCTS

SAFETY INFORMATION. 7. Do not force switched or external connections in any way. They should all connect easily, without needing to be forced.

ZVOX AccuVoice TV Speaker Model AV203

Power Injector 1520 Series

Installation Manual VIP 1003

ZVOX AccuVoice TV Speaker Model AV203

BP2-MM MM Phono Preamplifier Owner s Manual

S/PDIF & USB D/A Converter. User Manual. Rev.A3, May 2010 Audial d.o.o Belgrade, Serbia

Model FS-4608R. Features. Overview

Owner's Manual PPA-1 Phono Preamp

Wired to Wireless Camera Converter

Operating Instructions

BP2-MM/MC Phono Preamplifier Owner s Manual

USER MANUAL. Kramer Electronics, Ltd. Models:

Model FS-4608SR. Features. Overview

USER S MANUAL. Deuce HD User's Manual WORLD HEADQUARTERS

UTP TRANSMITTER & RECEIVER SUT-80/SUR-10 USER S MANUAL ENGLISH

HPA-8 8 Channel Headphone Amplifier. Owner s Manual

HD Digital MPEG2 Encoder / QAM Modulator Get Going Guide

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

Operating Manual. Mark Levinson Nº25 Dual Monaural Phono Preamplifier. Madrigal Audio Laboratories, Inc. 1

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

NTI. VOPEX-C5VA/C5V-x(C) VOPEX-C5CMPSA-x VOPEX-M12V-4. Video/Audio or Video Only Splitter/Extender Installation and Operation Manual.

Operating Manual. Mark Levinson Nº28 Preamplifier. Madrigal Audio Laboratories, Inc. 15

ZVOX AccuVoice TV Speaker MODEL AV150.

PNP300 / PNP300UN / PNP350

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

HDBaseT EXTENDER B-600-EXT-330-RS-IP INSTALLATION MANUAL

TVP-20 / RVP-412 CCTV VIDEO-PLEXER

TECHCONNECT OWNERS MANUAL

Operating Manual. CAT5 Audio Balun KD-CAT5XST

Model 1476-C SuperQuad HR

MON3-2W/HR MON4-2W/HR (Document P/N Rev-B)

KD-CATDRV. Operating Instructions. HDMI CAT5/5e/6 Extender

MON8-1/SDI 1U 8-Channel SDI Digital Multi-Display Video Monitor

ST-CCTV-VBAC 1 Channel UTP Active Video Balun Transceiver

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Model FS-HD4616VPS-36VDC. Features

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

Instruction Manual. 4x1 VGA Routing Switcher Series

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

TS2.8 Sub OWNER S MANUAL

DISTRIBUTION AMPLIFIER

AUTOMATIC VIDEO LOSS A/B SWITCH

Evolution Digital HD Set-Top Box Important Safety Instructions

MON8-1 1U 8-Channel Multi-Display Video Monitor

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

XTENDEX Series. ST-C6DVI(A)-300 ST-C6DVI(A)-IR FOOT DVI VIDEO, AUDIO AND IR EXTENDER Installation and Operation Manual

MAW218D7. User s manual. Pol.Ind.Norte-Perpinyà, TERRASSA (Barcelona-SPAIN)

TPW300series. CAT5/6 RGBHsVs TRANSCEIVERS

LED TV MODEL NO.: NE22K5BG. Please read this manual carefully before installing and operating the TV. Keep this manual handy for further reference

Disclaimer. Warning and Caution CAUTION!

PH-1. Italian MM & MC Phono Preamplifier OWNER S MANUAL

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

VS81 8X1 COMPOSITE VIDEO SWITCHER INSTALLATION AND OPERATION MANUAL

INSTALLATION MANUAL VIP 1903 / VIP 1903 T VIP 1963 / VIP 1963 T

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Operating Instructions

1x12 VGA & Audio over CAT5 Splitter

DA1931CT/ TP to Video + Audio Receiver

Wireless 4 Channel Receiver with 2 Night Vision cameras

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Technical Specifications

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

INSTALLATION INSTRUCTIONS FOR

GMB101R BLACK BURST & PATTERN GENERATOR GMB101R-M 09/06/08

CM-S23349SV. Vari-Focal IR Bullet Camera

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

Outdoor IR Audio Camera

guestlink PowerWave PW4A Panel and Wall-Mount Models Installation Guide AV69102-XXX-XXX

UTP ACTIVE TRANSCEIVER HUB

CM-S38901SV TVL IR Long Range camera

Transcription:

Active UTP Transceiver Hub Installation Guide Models Include: HubWayEX16 - Sixteen (16) Channels - Thirty-two (32) Channels Rev. 011810 More than just power. TM

Overview: Altronix HubWayEX16/EX32 Active UTP Transceiver Hub employs automatic gain control (AGC) to transmit UTP video, RS422/RS485 data over a single or higher structured cable. Units provide either 16 or 32 camera channels in a space saving 1U EIA 19 rack mount chassis which may be rack, wall or shelf mounted. transmission range is up to one mile max. per channel. Units are compatible with fixed or cameras. Each grouped camera channel provides video transmission for up to four (4) cameras over a single or higher structured cable. This permits the installation of up to sixteen (16) cameras at remote locations over four (4) or higher structured cables or thirty-two (32) cameras at remote locations over eight (8) or higher structured cables. HubWayEX16 Input: 115VAC 60Hz, 0.4 amp or 230VAC 50Hz, 0.2 amp. : Sixteen (16) channels of video over twisted pair up to a distance of 5000 ft. per channel. Sixteen (16) 75 ohm video outputs. : RS422/RS485 data inputs. Visual Indicators: AC input power indicator. signal and power LED indicators. Features: Automatic picture and gain control. Automatic compensation for reverse polarity wiring (video). Illuminated master power disconnect circuit breaker with manual reset. HubWayEX Specifications: Specifications: Input: 115VAC 60Hz, 0.4 amp or 230VAC 50Hz, 0.2 amp. : Thirty-two (32) channels of video over twisted pair up to a distance of 5000 ft. per channel. Thirty-two (32) 75 ohm video outputs. Features (cont d): IEC 320-3-wire grounded line cord (detachable). Unit can be rack, wall or shelf mounted. 1U rack mount chassis for use in standard EIA 19 rack. Accessories: Optional HubSat4D/Di or HubWayEXP allows transmission of up to four (4) video signals over a single or higher structured cable. WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes. Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. 1. Set the input voltage selector switch located on the left side of the HubWayEX16/EX32 unit (facing front panel) for 115VAC or 230VAC operation (Fig. 1b, pg. 3). 2. Attach mounting brackets to HubWayEX16/EX32 unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber pads to HubWayEX16/EX32 for shelf installation (Fig. 8, pg. 8). 3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3 from any video monitors). 4. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7). 5. Plug the grounded AC line cord into the IEC 320 connector of the HubWayEX16/EX32. For US & Canada the plug end is a 3 prong type B plug used for standard 115VAC receptacles, as provided with unit (Fig. 1g, pg. 3). For non North American 230VAC applications use the appropriate 3 prong plug that matches the local standard receptacle. 6. Connect the BNC video outputs for HubWayEX16/EX32 Channels 1-32 to the corresponding video inputs on the head end equipment (DVR) (Fig. 1c, pg. 3). 7. Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal blocks of the HubWayEX16/EX32 unit (polarity must be observed) (Fig. 1f, pg. 3). Note: The input terminals of the HubWayEX16/EX32 must be wired in parallel for proper operation. When using fixed cameras disregard this step. 8. Connect one (1) end of a or higher structured cable into the RJ45 jack marked [CH 1-4, CH 5-8, CH 9-12, CH 13-16] of the HubWayEX16 or [CH 1-4, CH 5-8, CH 9-12, CH 13-16, CH 17-20, CH 21-24, CH 25-28, CH 29-32] of the (Fig. 1d, pg. 3). Connect the opposite end of the or higher structured cable into the corresponding RJ45 jack marked [CH 1-4, CH 5-8] HubWayEXP (Fig. 4, pg. 5) or [VIDEO 1-4] of the HubSat4D/Di (Fig. 5, pg. 6). - 2 - HubWayEX16/ Active Hub Unit

115VAC 220VAC 1g - IEC 320 Connector: Grounded line cord included. input from Head End Equipment (DVR). + -- 1b - Input Voltage Switch: Selects 115VAC/230VAC (switch is located on the left side of the unit). 1a - LED(s) 1-16: signal indicators. Fig. 1 Front 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ACTIVE ACTIVE EX 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Rear CH 9-12 8 7 6 5 CH 5-8 4 3 2 1 16 15 14 13 CH 13-16 12 11 10 9 24 23 22 21 CH 21-24 20 19 18 17 CH 17-20 32 31 30 29 CH 29-32 28 27 26 25 CH 25-28 Top View 1e - 1-16, 17-32: or higher structured cable to HubWayEXP for the data transmission to s. 1d - Channels 1-4, 5-8, 9-12. 13-16, 17-20, 21-24, 25-28, 29-32: or higher structured cable to HubWayEXP utilized for the video transmission. 1c - BNC Connector: outputs to head end equipment (DVR). 1f - : Removable terminal blocks for RS422/ RS485 input from head end equipment (DVR) for control. HubWayEX16/ Active Hub Unit - 3 - HubWayEX16 Front ACTIVE ACTIVE EX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 HubWayEX16 Rear 8 7 6 5 CH 5-8 4 3 2 1 16 15 14 13 CH 13-16 12 11 10 9 CH 9-12

9. Connect one (1) end of a or higher structured cable into the RJ45 jack marked [] of the HubWayEX16/EX32 (Fig. 1e, pg. 3). Connect the opposite end of the or higher structured cable into the RJ45 jack marked [] of HubWayEXP (Fig. 4, pg. 5) or [ 1-4] of the HubSat4D/Di (Fig. 5, pg. 6). Note: When using fixed cameras disregard this step. Repeat steps 8 and 9 for cameras 5-8, 9-12, 13-16, 17-20, 21-24, 25-28, 29-32. (refer to HubSat4D/Di or HubWayEXP installation instructions for camera hookups). 10. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7). 11. The video signal indicator LEDs (Red) located on the front of the HubWayEX16/EX32 will illuminate when video signal is present (Fig. 1a, pg. 3). If any of these LEDs are not illuminated, there is no video signal for that corresponding channel. HubWayAv and Balun/s: Altronix Input Voltage Model Number from HubWay unit Output Voltage to Type LED HubWayAv */28VAC */28VAC cameras Green */28VAC 12VDC 12VDC cameras Red *Based on camera load and structured cable length. Fig. 2 Fig. 2a VIDEO Fig. 2c VIDEO HubWayAv VIDEO BALUN/COMBINER VIDEO BALUN/COMBINER CAT5 AC + -- POWER CAT5 + -- -- 12VDC+ RJ45 Jack Wire Connectors RJ45 Jack Wire Connectors Fig. 2b Fig. 2d To BNC Connector of Structured Cable from HubWayEX16 or Green LED AC to -- to + HubWayAv passes AC voltage from pins 4, 5, 7, 8 to terminals marked [AC ] (Fig. 3, pg. 5). To BNC Connector of Structured Cable from HubWayEX16 or Red LED + 12VDC -- to -- to + converts AC voltage to DC voltage from pins 4, 5, 7, 8 to terminals marked [-- 12VDC +] (Fig. 3, pg. 5). Fig. 3 - Structured Cable Wiring Color Codes and PIN Configurations 1 - White/Orange [VIDEO +] 2 - Orange [VIDEO -- ] 3 - White/Green [ +] 4 - Blue [AC 1] 5 - White/Blue [AC 2] 6 - Green [ -- ] 7 - White/Brown [AC 2] 8 - Brown [AC 1] - 4 - HubWayEX16/ Active Hub Unit

Fig. 4 Head End Equipment (DVR) Typical Applications: RS485 Monitor Rear Panel 16 15 14 13 CH 13-16 12 11 10 9 CH 9-12 CH 5-8 8 7 6 5 4 3 2 1 32 31 30 29 CH 29-32 28 27 26 25 CH 25-28 24 23 22 21 CH 21-24 20 19 18 17 CH 17-20 HubWayEXP Front Panel RESET OFF 1 2 3 4 CH 1-4 5 6 7 8 CH 5-8 9 10 11 12 CH 9-12 13 14 15 16 CH 13-16 28VAC 28VAC OFF OFF + -- 1-8 + -- 9-16 Max. video 5000 ft. Max. video 5000 ft. Balun Balun Balun Balun Balun Balun Balun Balun HubWayEX16/ Active Hub Unit - 5 -

Fig. 5 Head End Equipment (DVR) Typical Applications: RS485 Monitor Rear Panel 16 15 14 13 CH 13-16 12 11 10 9 CH 9-12 CH 5-8 8 7 6 5 4 3 2 1 32 31 30 29 CH 29-32 28 27 26 25 CH 25-28 24 23 22 21 CH 21-24 20 19 18 17 CH 17-20 () Four (4) signals on a single. Max. video 5000 ft. Four (4) signals on a single. Max. video 5000 ft. 12VDC HubWayAv 12VDC HubWayAv 12VDC /28VAC Provided by HubSat4D/Di 115VAC Input 50/60Hz HubWayAv 12VDC /28VAC Provided by HubSat4DDi 115VAC Input 50/60Hz (Coax) - 6 - HubWayEX16/ Active Hub Unit

1U EIA 19 Rack Mount Chassis Mechanical Drawing and Dimensions: 1.625 x 19.125 x 8.5 (41.275mm x 486mm x 216mm) REAR 17.125 (434.97mm) 1.625 (41.275mm) 16 15 14 13 CH 13-16 12 11 10 9 CH 9-12 8 7 6 5 CH 5-8 4 3 2 1 CH 29-32 CH 25-28 CH 21-24 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 TOP and BOTTOM CH 17-20 8.5 (215.9mm) FRONT EX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 0.95 (24.13mm) (ON) 19.125 (485.775mm) Fig. 6 Illuminated master power disconnect circuit breaker: OFF position Circuit breaker tripped Switch not illuminated. RESET (ON) position Switch illuminated. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. HubWayEX16/ Active Hub Unit - 7 -

Mounting Options: Rack Mount Installation 1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 7a). 2- Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B) (included) (Fig. 7b). 3- Place unit into desired EIA 19 rack position and secure with mounting screws (not included) (Fig. 7c). Fig. 7 Fig. 7a Fig. 7b Fig. 7c Top Top Top Front Left B Front Left Front Left Remove A Wall Mount Installation 1- Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 8a). 2- Place unit at desired location and secure with mounting screws (not included) (Fig. 8b). Fig. 8 Caution: It is necessary to make sure mounting screws Fig. 8a Fig. 8b are securely fastened to a beam when installing the unit vertically. B A Dotted lines indicate studs behind sheetrock. Shelf Installation 1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 9). 2- Place unit in desired location. Fig. 9 C Left Side Rubber Pad Mounting Hardware (Included): A B C Two (2) mounting brackets Six (6) flat head screws for mounting brackets. Four (4) rubber pads. Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIHubWayEX16/EX32 C19O MEMBER - 8 - HubWayEX16/ Active Hub Unit