Similar documents
General Specifications

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Model JDF Field Indicator

Rosemount 1151 Smart Pressure Transmitter

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Pressure transmitter For applications in hazardous areas Model IS-3

TFRN Industrial RTD temperature sensor. CombiTemp TM

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Capacitance Level Measurement Electronic insert FEC 12

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

associates APPLICATION GUIDE AG334 Externally powered pulse input Rate Totalisers For models with an 'E' or 'G' suffix

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

FBT-6. Relcom. Fieldbus. fieldbus powered USB. FOUNDATION Fieldbus. segment. Recording the. segment. The Monitor collects this transfer to.

Process transmitter RMA422

Process Transmitter RMA 422

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Inductive sensor BI1.5-EG08K-Y1

Installation instructions Cable transit device Roxtec RS ES Ex

TFRN Industrial RTD temperature sensor. CombiTemp TM

Signal conditioning instruments

Installation instructions Roxtec RS ES Ex

Inductive sensor With analog output BI15-M30-LI-EXI

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

TFR5 Room or outdoor temperature sensor. CombiTemp TM

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

PROPORTIONAL VALVES Sentronic plus

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Inductive sensor NI10-M18-Y1X-H1141

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

ACT20X Series for hazardous area applications Section A

Inductive sensor NI3-EG08K-Y1-H1341

RMA 3000 Remote Meter Assemblies Specifications

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

ENCODERS FOR OIL & GAS

DMP 331i / DMP 333i LMP 331 i

PMG. Vibration Energy Harvesters

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Flow Measurement SITRANS F M

Level Measurement Continuous level measurement - Capacitance transmitters

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

The measurements are stored in non-volatile memory, which retains data even when the power down.

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Pendant Light Fitting IEC Series 6470/2

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

FIELD MOUNTED RATE TOTALISER MODEL 202D

MF-PFT. Programmable differential pressure transmitter for pressure or flow measurement and control. DIL1 Output/Utsignal

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

RMA42. Technical Information

IEPE Premium Accelerometer, Side Connector

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

4X70 PROFINET SYSTEM

Level Measurement Point level measurement - RF Capacitance switches

RSCC. Load cells. Special features. Data sheet

Installation instructions Ex frames

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/224 Siemens FI Overview.

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Separate Thin Amplifier type. AP-V40AW Series

IEPE Premium Accelerometer, Top Connector

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

Thermoacoustics Technical Brochure. Product Line for Combustion Dynamics on Gas Turbine.

Pressure transmitter COMPACT IO-Link,

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

3500/42M Proximitor*/Seismic Monitor

Explosion Proof Audible Signal db(a) Series YA60

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

General Specifications

2070 PROFINET MODULE

MAGNETOSTRICTIVE LEVEL TRANSMITTER

General Specifications

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Level Measurement Continuous level measurement Radar transmitters

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

FLEX Ex System Certification

General Specifications

Explosion Proof Audible Signal db(a) Series YA60

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Level Measurement Point level measurement RF Capacitance switches

Level Measurement Continuous level measurement Radar transmitters

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

SAUTER flexotron RDT405 Manual

Guided Radar (TDR) Level Transmitter for storage and process applications

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Transcription:

General Specifications EJA-E Series PROFIBUS PA Communication PROFIBUS is a vendor-independent and open fi eldbus based on the international standerd IEC61158 and IEC61784. It covers a wide range of applications in manufacturing and process automation fi elds. Vendor-independence and openness allow communication between devices of different maunfactuers with no special interface adjustment. EJA-E PROFIBUS PA model offers more fl exible instrumentation through a higher level communication capability and proposes the cost reduction by multidrop wirings with less cables. FEATURES Interoperability PROFIBUS specifi cations grant the interoperability of the field instruments without preparing designated softwares for the instrument. Multi-sensing function EJA110E PROFIBUS PA model, for example, has three independent AI function blocks for differential pressure and static pressure. Local operation interface (Applicable when digital indicator is specified) In addition to being able to perform zero adjustments, the local operation interface can be used to set the Bus address and Ident number by using switch on LCD within Digital indicator code E and external adjustment screw. With this function, it is no longer necessary to use a communication device to set the fi eld device parameters; this can be done directly on the fi eld device. Multi-signal display (Applicable when digital indicator is specified) Up to four I/O signals can be alternatively displayed on the digital indicator. The block tags, the parameter names, the process units and the statuses are also displayed in order to show what the displayed signals are. Alarm function EJA-E PROFIBUS PA models securely support various alarm functions, such as high/low alarm, notice of block error, etc. based on PROFIBUS specifi cations. Self-diagnostic function A reliable self-diagnostic function based on the NAMUR NE107 standard detects failures in the hardware of pressure sensor, temperature sensor or amplifi er assembly, measuring range setting, and communications. Signal totalizer function Totalized process values can be calculated using the PROFIBUS totalizer function block. This enables the EJA-E to output totalized fl ow rate signals for fl ow applications. A periodic backup function guards against the loss of data when the power supply is disrupted. Supported tools DTM for FieldMate EDD for SIEMENS SIMATIC PDM Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5690 Fax.: 81-422-52-2018 Copyright April 2013 8th Edition April 2018

STANDARD SPECIFICATIONS For items other than those described below, refer to each General Specification sheet. Applicable Model: All DPharp EJA-E series. Output: Digital communication signal based on PROFIBUS PA protocol. Supply Voltage: 9 to 32V DC for general use, flameproof type, intrinsically safe (Ex ic), or nonincendive. 9 to 24 V DC for intrinsically safe type Entity model 9 to 17.5 V DC for intrinsically safe type FISCO model Communication Requirements: Supply Voltage: 9 to 32 V DC Current Draw: 15 ma (max) Response Time (for Primary Value) 150 ms When amplifier damping is set to zero, and including dead time. 185 ms for the following model and specification - EJA120E and EJA130E - Measurement span code: F and L Update Period: Differential Pressure: 100 ms Static Pressure: 100 ms Capsule Temperature: 1 s Amplifier Temperature: 1 s Integral Indicator (LCD display) 5-digit Numerical Display, 6-digit Unit Display and Bar graph. The indicator is configurable to display one or up to four of the I/O signals periodically. Functional Specifications: Functional specifications for PROFIBUS communication conform to the PROFIBUS PA Ver 3.02. Function Block: Three AI blocks, One Totalizer block 2 MODEL AND SUFFIX CODES EJA E-G - / Output signal... Digital communication (PROFIBUS PA protocol) OPTIONAL SPECIFICATIONS For items other than those described below, refer to each General Specification sheet. Data configuration at factory *1 Software damping CD *1: Also see Ordering Information OPTIONAL SPECIFICATIONS (For Explosion Protected type) Factory Mutual (FM) FM Explosionproof *1 Applicable Standard: FM3600, FM3615, FM3810, ANSI/NEMA 250 Explosionproof for Class I, Division 1, Groups B, C and D, Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G, in Hazardous locations, indoors and outdoors (Enclosure: Type 4X) FACTORY SEALED, CONDUIT SEAL NOT REQUIRED. Temperature class: T6, Amb. Temp.: 40 to 60 C ( 40 to 140 F) FM Intrinsically Safe and Nonincendive * 1 Applicable Standard: FM3600, FM3610, FM3611, FM3810, ANSI/NEMA 250, IEC60079-27 Intrinsically Safe for Class I,II, & III, Division 1, Groups A,B,C,D,E,F & G, Entity, FISCO Class I, Zone 0, AEx ia IIC, Enclosure: Type 4X, Temp. Class: T4, Amb. Temp.: 40 to 60 C ( 40 to 140 F) Intrinsically Apparatus Parameters : [FISCO (IIC)] Ui=17.5 V, Ii=380 ma, Pi=5.32 W, Ci=3.52 nf, Li=0 μh [FISCO (IIB)] Ui=17.5 V, Ii=460 ma, Pi=5.32 W, Ci=3.52 nf, Li=0 μh [Entity] Ui=24 V, Ii=250 ma, Pi=1.2 W, Ci=3.52 nf, Li=0 μh Nonincendive for Class I, Division 2, Groups A, B, C and D, NIFW, FNICO Class I, Zone 2, Group IIC, NIFW, FNICO Class II, Division 2, Groups F&G Enclosure: Type 4X, Temp. Class: T4, Amb. Temp.: 40 to 60 C ( 40 to 140 F) Nonincendive Apparatus Parameters : Vmax.= 32 V, Ci = 3.52 nf, Li = 0 μh FF1 FS15 Jul. 24, 2015-00

3 ATEX ATEX Flameproof *1 Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-1:2007 ( 2014 from August 1, 2017), EN 60079-31:2014 Certificate: KEMA 07ATEX0109 X II 2G, 2D Ex d IIC T6...T4 Gb ( Ex db IIC T6...T4 Gb from August 1, 2017), Ex tb IIIC T85 C Db Degree of protection: IP66/IP67 Amb. Temp. (Tamb) for gas-proof : T4; 50 to 75 C ( 58 to 167 F), T5; 50 to 80 C ( 58 to 176 F), T6; 50 to 75 C ( 58 to 167 F) Process Temp. for gas-proof (Tp): T4; 50 to 120 C ( 58 to 248 F), T5; 50 to 100 C ( 58 to 212 F), T6; 50 to 85 C ( 58 to 185 F) Max. surface Temp. for dust-proof: T85 C (Tamb: 30 to 75 C, Tp: 30 to 85 C) *2 ATEX Intrinsically safe [Ex ia] *1 No. KEMA 04ATEX1116 X Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012 II 1G, 2D Ex ia IIC/IIB T4 Ga Ex ia IIIC T85 C T100 C T120 C Db Ambient Temperature for EPL Ga: 40 to 60 C Ambient Temperature for EPL Db: 30 to 60 C *2 Maximum Process Temperature (Tp.): 120 C Maximum Surface Temperature for EPL Db. T85 C (Tp.: 80 C) T100 C (Tp.: 100 C) T120 C (Tp.: 120 C) Ambient Humidity: 0 to 100% (No condensation) Degree of Protection: IP66/IP67 Electrical Data: [FISCO (IIC)] Ui = 17.5 V, Ii = 380 ma, Pi = 5.32 W, Ci = 3.52 nf, Li = 0 μh [FISCO (IIB)] Ui = 17.5 V, Ii = 460 ma, Pi = 5.32 W, Ci = 3.52 nf, Li = 0 μh [Entity] Ui = 24 V, Ii = 250 ma(resistively limited), Pi = 1.2 W, Ci = 3.52 nf, Li = 0 μh ATEX Intrinsically safe [Ex ic] *1 Applicable standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012 II 3G Ex ic IIC T4 Gc Amb. Temp.: 30 to 60 C ( 22 to 140 F) *2 Ui = 32 V, Ci = 3.52 nf, Li = 0 μh Canadian Standards Association (CSA) CSA Explosionproof *1 Certificate: 2014354 Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.0.5, C22.2 No.25, C22.2 No.30, C22.2 No.94, C22.2 No.60079-0, C22.2 No.60079-1, C22.2 No.61010-1, C22.2 No.61010-2-030 Explosion-proof for Class I, Groups B, C and D. Dustignition-proof for Class II/III, Groups E, F and G. When installed in Division 2, SEAL NOT REQUIRED Enclosure: Type 4X, Temp. Code: T6...T4 Ex d IIC T6...T4 Enclosure: IP66/IP67 Max.Process Temp.: T4;120 C (248 F), T5;100 C (212 F), T6; 85 C (185 F) Amb.Temp.: 50 to 75 C ( 58 to 167 F) for T4, 50 to 80 C( 58 to 176 F) for T5, 50 to 75 C ( 58 to 167 F) for T6 *2 Process Sealing Certification Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01 No additional sealing required Primary seal failure annunciation: at the zero adjustment screw CSA Intrinsically safe *1 Certificate: 1689689 Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.25, C22.2 No.94, C22.2 No.157, C22.2 No.213, C22.2 No.61010-1, C22.2 No.61010-2-030 CAN/CSA E60079-11, CAN/CSA E60079-15, IEC 60529 Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G, Class III; Ex ia IIC T4 Amb. Temp.: 40 to 60 C( 40 to 140 F) *2 Encl. Type 4X, IP66/IP67 Entity Parameters for Intrinsically Safe : Ui (Vmax) = 24 V dc, Ii (Imax) = 250 ma, Pi (Pmax) =1.2 W, Ci = 3.52 nf, Li = 0 μh or Ui (Vmax) = 17.5 V dc, Ii (Imax) = 380 ma, Pi (Pmax) = 5.32 W, Ci = 3.52 nf, Li = 0 μh Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2, Groups F & G, Class III; Ex nl IIC T4 Amb. Temp.: 40 to 60 C ( 40 to 140 F) *2 Encl. Type 4X, IP66/IP67 Entity Parameters for Nonincendive: Ui = 32V dc, Ci = 3.52 nf, Li = 0 μh Process Sealing Certification Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01 No additional sealing required Primary seal failure annunciation: at the zero adjustment screw KF22 KS26 KN26 CF1 CS15 June 1, 2017-00

4 IECEx IECEx Flameproof *1 Applicable Standard: IEC 60079-0:2011, IEC60079-1:2007-4 Certificate: IECEx CSA 07.0008 Flameproof for Zone 1, Ex d IIC T6...T4 Gb Enclosure: IP66/IP67 Max.Process Temp.: T4;120 C(248 F), T5;100 C(212 F), T6; 85 C(185 F) Amb.Temp.: 50 to 75 C( 58 to 167 F) for T4, 50 to 80 C( 58 to 176 F) for T5, 50 to 75 C( 58 to 167 F) for T6 IECEx Intrinsically safe Approval *1 Intrinsically safe Ex ia Certificate No.: IECEx DEK 12.0016X Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011 Ex ia IIC/IIB T4 Ga Amb. Temp.: 40 to 60 C( 40 to 140 F), Max. Process Temp.: 120 C(248 F) Electrical parameters: [Entity] Ui = 24 V, Ii= 250 ma, Pi = 1.2 W, Ci = 3.52 nf, Li = 0 μh [FISCO IIC] Ui = 17.5 V, Ii = 380 ma, Pi = 5.32 W, Ci = 3.52 nf, Li = 0 μh [FISCO IIB] Ui = 17.5 V, Ii = 460 ma, Pi = 5.32 W, Ci = 3.52 nf, Li = 0 μh Intrinsically safe Ex ic Certificate No.: IECEx DEK 13.0064X Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011 Ex ic IIC T4 Gc IP code: IP66 Amb. Temp.: 30 to 60 C( 22 to 140 F) *2, Max. Process Temp.: 120 C(248 F) Electrical parameters: Ui = 32 V, Ci = 3.52 nf, Li = 0 μh Contact Yokogawa representative for the codes indicated as -. *1: Applicable for Electrical connection code 2, 4, 7, 9, C and D. *2: Lower limit of ambient temperature is 15 C (5 F) when /HE is specified. SF2 SS26 June 1, 2017-00

< Ordering Information > Specify the following when ordering 1. Model, suffix codes, and option codes 2. Calibration range and unit (Scale In Lower/Upper Value); 1) Calibration range can be specified with range value specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of 32000 to 32000. 2) Specify only one unit from the table, Factory Setting. 3. Output mode (Characterization Type); Select LINEAR or SQUARE ROOT. 4. Output scale and unit (Out Scale Lower/Upper value); When digital indicator is required, the scale range can be specified with range limit specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of 32000 to 32000. Unit display consists of 6-digit, therefore, if the specified scaling unit excluding / is longer than 6-characters, the first 6 characters will be displayed on the unit display. 5. Tag Number; Specify software tag (up to 32 letters) to be written on the amplifier memory and Tag number (up to 22 letters, or 16 letters when /N4 is specified) to be engraved on the tag plate separately. 6. Bus Address Specify the address between hexadecimal 0x03(3) and 0x7E(126). [When /CD option is specified] 7. Software damping (Filter Time Const of AI function Block); Specify software damping: 0.00 to 100.00(s) 5 Example; When 50 to 1000 mmh2o for calibration range and 0 to 100% output scale is required, specify the values as follows: Calibration range: Higher value 1000 Lower value 50 Calibration unit: mmh2o Output scale: Higher value 100 Lower value 0 Unit of output scale: % Output mode: Linear Explanation of PROFIBUS PA parameters: (1) Characterization Type: Type of Linearization, LINEAR or SQUARE ROOT can be selected. (2) Scale In Lower/Upper Value: The value set as calibration range should be entered to this parameter. This is the input conversion of the Pressure using the high and low scale. (3) Pressure Unit: The unit of calibration by sensor, this is used as the unit of Scale In. (4) Out Scale Lower/Upper value: Output scaling parameter. Set the output value which corresponds to 0% value and 100% value of the calculation in the AI1 function block. The value set as output scale should be entered to this parameter. When integral indicator is required, this output is shown on LCD. < Related Instruments > The customer should prepare instrument maintenance tool, terminator, Profibus power supply etc. < DP/PA Coupler for ATEX Intrinsically Safe Type > Supplier DP transmission Rate Model P+F 97.75kbps KFD2-BR-Ex1.3 PA.93 SIEMENS 45.45kbps 6ES7 157-0AD82-0XA0 < Factory Setting > Tag Number (Tag plate) Software Tag (TAG) Bus Address Output Mode (Characterization Type) Calibration Range (Scale In Lower/Upper Value) Calibration Range Unit Output Scale (Out Scale Lower/Upper Value) Software Damping (Filter Time Const) *1 < Reference > ; Registered trademark of Yokogawa Electric Corporation. PROFIBUS; Registered trademark of Profibus Nutzerorganisation e.v., Karlsruhe, Germany. As specified in order PT1001 unless otherwise both Tag Number and Software Tag specified in order 0x7E(126) unless otherwise specified in order Linear unless otherwise specified in order As specified in order Selected from mmh2o, mmh2o(68 F), mmhg, Pa, hpa, kpa, MPa, mbar, bar, gf/cm 2, kgf/cm 2, inh2o, inh2o(68 F), inhg, fth2o, fth2o(68 F) or psi. (Only one unit can be specified) 0 to 100% unless otherwise specified. 2 s or as specified in order *1: To specify this item, /CD option is required. Subject to change without notice. April 10, 2018-00