Trimble CFX-750 Display with the Field-IQ Crop Input Control System

Similar documents
with the Field-IQ Crop Input Control System

Mounts Machinery Field IQ Manual for CFX/FM-750 Display (ver 2.0)

Trimble TMX-2050 Display Quick Reference Card

Outback STX. User Guide Supplement. Parts List. STX Terminal Overview

GPS FmX Integrated Display

Quick Setup Guide for IntelliAg Model NTA

Quick Setup Guide for IntelliAg Model CTA

955608_01 4/4/18. SeedSense Operator s Guide For Gen2 20/20 Displays

vset Select System Operation

SureDrive SureDrive. Press the Planting App from the home screen. This will take you through the steps needed to load a configuration.

RowFlow Operators Manual

Operation Guide. Cruizer II (Software Version 3.4)

Release Notes Electric Drive

Table of Contents. Introduction...1 Legal Notices...1 About the EZ Guide 250 System...1 Related Information...2 Technical Support...

Table of Contents. Introduction...1 Legal Notices...1 About the EZ Guide 250 System...1 Related Information...2 Technical Support...

Version 1.0 English. Leica mojo3d User Manual

U s e r G u i d e

Advanced Seed Monitoring

icontrol Integrated Control System Operator s Card

Check out the Great New JD Products

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

*OMPFP12264* OPERATOR'S MANUAL OMPFP12264 ISSUE F2 (ENGLISH) CALIFORNIA Proposition 65 Warning

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

DPS Telecom Your Partners in Network Alarm Management

User interface. Abbreviations / Meanings

Home Page 1 Press the House button I E

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

OPERATORS MANUAL & FITTING INSTRUCTIONS FOR CENTERLINE

John Deere GS2 2600, 1800 and GS , 48 and 49 Series Display Kit Installation Manual GS2-SP01

Solutions for success

COPYRIGHT NOVEMBER-1998

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Chapter 2: Scanner Operations NOTE: Install the software cartridge Power the Scanner Select the software title Identify the vehicle

Control Unit CU 2.1 User Manual V6850A HPLC

Seed and Small Seeds Rate Charts for 3N-3010 and 3N-3020 No-Till Drill

SPECIFICATION NO NOTE

Tracer AdaptiView Display

Table of Contents Displays and Consoles...1 InCommand...34

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

User s Manual. Log Scale (/LG) GX10/GP10/GX20/GP20 IM 04L51B01-06EN. 1st Edition

TECHNICAL UPDATES. from by TeeJet Technologies. BoomPilot Kits Include: - BoomPilot Console - SmartCable - Lighter Adapter - RAM mount.

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 2nd Edition

Outback STX User Guide

EDL8 Race Dash Manual Engine Management Systems

MXS Strada USER GUIDE

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

SV-LCD50. Installation and User Guide. Thin-Film Transistor (TFT) Liquid Crystal Display (LCD) Color Rear Vision Monitor. Version 1.

More Skills 14 Watch TV in Windows Media Center

DVB-LR10. Compatible with Land Rover touch-screen navigation systems version 2

Video VBOX Pro RLVD10P2P/RLVD10P2PV/RLVD10P4PV/RLVD20P2PV/RLVD20P4PV. Features

Software Quick Manual

EAN-Performance and Latency

Video VBOX Waterproof

Gazer VI700A-SYNC/IN and VI700W- SYNC/IN INSTALLATION MANUAL

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

SYSTEM DESCRIPTION 2.1 MAIN DISPLAY SCREEN 2.2 SYSTEM DIAGNOSTIC MENU 2.6 SETTING AND OPERATING INSTRUCTIONS 2.10 TO SET DEFAULT PARAMETERS 2.

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Operating Instructions

LiteStar IV User Guide

Video VBOX Lite RLVBVD10LT2. Powerful VBOX data logging and video technology in a user-friendly, affordable product. What can Video VBOX Lite do?

Omnitracs is a trademark of Omnitracs, LLC. All other trademarks are the property of their respective owners.

DT1-LR10. Compatible with Land Rover touch-screen navigation systems version 2

CytoFLEX Flow Cytometer Quick Start Guide

OptoFidelity Video Multimeter User Manual Version 2017Q1.0

English DOWNLOAD ONLY

Mackie Control and Cubase SX/SL

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual

D-901 PC SOFTWARE Version 3

Hardware Setup. HP Dual TV Tuner/Digital Video Recorder. Document Part Number:

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

Modbus for SKF IMx and Analyst

Software Quick Manual

BLINKIN LED DRIVER USER'S MANUAL. REV UM-0 Copyright 2018 REV Robotics, LLC 1

Compatibility mode. rev. 0.1, 10/09/2015. Compatibility mode Sx tool manual 1

Using Impact LX+ with Reason

PSC300 Operation Manual

In this Issue: AMS News Letter. Software Updates. Display Phase Out. Topdressing. Spring Inside this issue:

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Auxiliary states devices

Addendum: Rain Dial Installation and Programming Guide Update

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Calibrating and Profiling Your Monitor

Training Note TR-06RD. Schedules. Schedule types

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition

Yellow Frog. Manual Version 1.1

J6 User Manual. User Manual. Multi-Screen Splicing Processor J6. Xi an NovaStar Tech Co., Ltd. Rev1.0.1 NS

Application Note 11 - Totalization

OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE.

LedSet User s Manual V Official website: 1 /

C Module Description

Tebis application software

DT1-LR. for Landrover touch-screen navigation systems version 1

U S E R G U I D E HD1000

Application Note #247 Revision E November 2014

Tebis application software

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

EM7680 TV Streamer powered by LibreELEC Kodi

Transcription:

Trimble CFX-750 Display with the Field-IQ Crop Input Control System Quick Reference Card RUN SCREEN The Trimble CFX-750 display is a touchscreen display that is configured and run by tapping the icons that appear on the display screen. The image below shows the run screen when using the Field-IQ system. 1 2 3 4 5 6 7 8 Item Description Notes 1 Quick Access icon Access common Field-IQ settings. 2 Coverage status On: Off: Inactive: 3 Target rate The target application rate for the current rate switch position. This is the amount of product that you want to apply. 4 Actual rate The actual application rate. This is the amount of product that is currently being applied. 5 Rate switch position Indicates the current position of the rate switch. 6 Section control Shows the current mode for the controller. Automatic: Manual: 7 Master switch status Master switch on: Master switch off: 8 Pressure P1: The current pressure reported by the primary pressure sensor. P2: The current pressure reported by the secondary pressure sensor. 1

QUICK START WIZARD By default, the Quick Start Wizard appears every time you turn on the CFX-750 display. It enables you to easily confirm or change important system settings before you begin working. SETUP AND CONFIGURATION Features can be set up or configured manually from the Run screen by tapping the button. HELP The CFX-750 display has built-in, context-sensitive Help that lets you quickly find information you need. To access Help from any configuration screen, tap. When you are finished with the Help screen, tap. Note - For more information on how to use this product, refer to the CFX-750 Display CD. The Field-IQ crop input control system enables the CFX-750 display to control planters, sprayers, liquid strip-till toolbars, and spinner spreaders. Additionally, it allows the display to use Tru Count Air Clutches or Tru Count LiquiBlock to perform automatic section control, and/ or use a prescription with Rawson drives to control seed or liquid fertilizer rates. Warning: Anhydrous ammonia (NH3) can cause severe burning, blindness, or death. Before you begin to operate or service equipment that contains NH3, carefully read and follow all safety instructions in the CFX-750 Display User Guide. Units of measure Type Unit Symbol Description Seed Granular seed Liquid application Granular fertilizer NH3 ks/ha ks/a kg/ha lbs/a L/ha Gal/a kg/ha lbs/a kg/nh3 lbs/nh3 kg/n lbs/n Field-iq system functionality Thousands of seeds per hectare Thousands of seeds per acre Kilograms of seed per hectare Pounds of seed per acre Liters per hectare Gallons per acre Kilograms of fertilizer per hectare Pounds of fertilizer per acre Kilograms of anhydrous per hectare Pounds of anhydrous per acre Kilograms of nitrogen per hectare Pounds of nitrogen per acre Definitions Application Section Row Master Switch Box (MSB) 12-section Switch Box (12SSB) Section Control Module (SCM) Rate and Section Control Module Rawson Control Module Implement switch Main functions A number of rows or spray nozzles controlled by Tru Count Air Clutches, Tru Count LiquiBlock valves, or boom valves. A section can have either a single row/nozzle or multiple rows/ nozzles depending on how the system is set up. The individual row unit that material comes from on the implement. This can be controlled individually (single row section), or as a group with other rows (multiple row section). Master on/off/jump start, auto/manual switch, rate selection, and increment/decrement switch. Required for section control. Manually control sections/rows. Controls 12 sections/rows per module with up to 4 modules (48 module sections/rows). Controls 12 sections and application rate for spraying, spreading and NH3. Controls 1 Rawson variable rate drive per module with up to 4 modules. Included in planter, NH3 and strip-till platform kits. 2

The CFX-750 display automatically detects the Section Control Modules and/or the Rawson Control Modules installed on the implement. When you use the wizard to set up your Field-IQ system, the screens that appear may differ according to the modules you have installed. If during the setup, a screen appears that you are unsure of, you can either: Tap to go back and check the previous screen(s). Tap to discard all of the changes and start again. 1. In the guidance screen, tap and then tap Implement. 2. In the Controller Type screen, tap Field-IQ: setting up and calibrating the Field-iq system of the wizard, you must enter accurate values for each of the following: For... Indicate... Rate Control Where on your implement each module is located. For each module, the width of the section it will control. Section Control Where on your implement each module is located. For each module, the number of sections it will control. 7. Once you have completed the wizard, you can adjust your section widths if necessary: 3. In the Field-IQ Hardware Summary screen, tap to continue through the setup wizard. 4. In the Application Controller Mode screen, select what you are using the implement for. The options are row crop planting, liquid, granular seed, granular spreading, and anhydrous. Note - If you change the Application Controller Mode, the display erases any previous calibrations. 5. In the Rate and Section Control screen, select: Section Control Only Rate Control Only Both Note - If you have not installed at least one section control box and at least one Rawson control box or a Rate and Section box, both options will not appear. 6. In the Implement Measurements screen, edit each of the setting items. The items that appear in this screen depend on the Application Controller Mode chosen previously. In this part Field-IQ Hydraulics Test After the setup wizard is complete, the display tests the hydraulics of your system. During this test you must run the motor(s) at the minimum and maximum RPM and make sure the motor(s) achieve these RPM. WARNING: MOVING PARTS DURING THIS TEST! Please stay clear of the implement. Ensure the implement is raised, the transmission is in PARK and the emergency brake is applied before continuing. Calibrating the Field-IQ system After the hydraulics test is complete, the display calibrates your system. The available calibrations are: Field-IQ Rawson Control Module Servo Pump or PWM Pump Pressure Sensors Implement Lift Switch When the calibration is complete, save the data to a configuration file and export it to the USB drive. 3

Use the Advanced option in the Implement screen to configure the following options: Controller and Material Type Selection Select this option to return to the Controller Type screen. Implement Setup Use this option to adjust the following settings: Rate Control Module Setup. If you select this option, the display returns you to the Rate Control screen in the Field-IQ setup wizard. Implement Measurements Setup. If you select this option, the display returns you to the Implement Measurements screen in the Field-IQ setup wizard. Section Control Module Setup. If you select this option, the display returns you to the Section screen in the Field-IQ setup wizard. Implement Application Setup. If you select this option, the display returns you to the Implement Application screen in the Field-IQ setup wizard. Auxiliary Valve Setup. If you select this option, the display allows you to enable an Auxiliary Valve. Pressure Sensor Setup. If you select this option, the display allow you to set up and calibrate up to two pressure sensors. Advanced setup Section Switching Setup Use this option to view and adjust the following settings: Setting Coverage switching overlap Boundary switching overlap On/Off valve latency Intentional overlap Description Control the amount of side-to-side section overlap allowed before the section will be switched by the system. Enter a value between 1-99%. Control the amount of overlap on a boundary before the boom section is switched off. Enter a value between 1-99%. Tune the section switching to allow for hardware delays. Enter a time between 0.0-10.0 seconds. Set a distance to be overlapped when moving to an unsprayed area or out of a sprayed area. Enter a distance between 0 00-32 10 (0.00-10.00 m). Field-IQ System Status Select this option to view the status for the following: Master Switch Module Section Switch Module Rate Control Module Section Control Module OEM Switch Interface Accessories Once you have enabled, configured and calibrated your Field-IQ crop input control system, the Run screen appears (see page 1). This allows you to control the application. 4

Operation Once you have enabled, configured and calibrated your Field-IQ crop input control system, the Run screen appears (see page 1). This allows you to control the application. Field-IQ master switch box All systems must have a Field-IQ master switch box. Field-IQ 12-section switch box The 12 section switch box is required for section control. For rate control only, the switch box is optional. Switch 1 Increment/ decrement Functions Increases the applied amount by a set amount (the amount set in the Setup screen, Rate tab). 2 Rate Choose preset Rate 1, preset Rate 2, or Manual rate. 3 LED indicator 4 Automatic/ Manual 1 2 3 4 5 Red Unit on, not communicating with the display. Green Unit on, communicating with the display. Yellow Unit initializing communications. a b c Automatic mode Display automatically opens and closes sections when entering areas of overlap, non-apply zones, or crossing boundaries. Manual mode Sections are controlled manually. 5 Master A. Jump start (top position). Sections and rate ready to be commanded by the display; the system overridden to use preset control speed. Use if you lose a GPS signal or want to start applying before the implement is up to speed. B. On (middle position). Sections and rate ready to be commanded by the display. C. Off (lower position). Sections are closed, rate set to zero. Only one section switch box can be used on each system. Each section switch is automatically assigned to the corresponding module. The modules are read from left to right. For example, switch 1 assigns to the module furthest on the left when standing behind the implement. The section switches have different functions, depending upon the status of the master Automatic/Manual section switch on the master switch box. When the Automatic/Manual section switch is in the Automatic position: If the section switch is in the on/up position the section(s) assigned to it are commanded automatically by the CFX-750 display. If the section switch is in the off/down position the section(s) assigned to it are commanded to be off. When the Automatic/Manual section switch is in the Manual position: If the section switch is in the on/up position, the section(s) assigned to it are commanded to be on. This overrides the CFX- 750 display and coverage logging is ignored. If the section switch is in the off/down position, the section(s) assigned to it are commanded to be off. This overrides the CFX- 750 display and coverage logging is ignored. The LED has the following status indicators: Green The unit is powered and is communicating with the CFX-750 display. Yellow The unit is initializing communications with the CFX-750 display. Red The unit is powered but not communicating with the CFX-750 display. 5

Trimble CFX-750 Display with the Field-IQ Crop Input Control System Quick Reference Card CONNECTING THE SYSTEM CFX-750 display To vehicle battery Antenna Basic power cable Antenna cable To vehicle battery CFX 750 display to Field-IQ cable CFX-750 power cable Power bus Field-IQ master switch box Remote foot switch (optional) Note: Not connected. Cab to hitch CAN cable Power to cab cable 12-section switch box (optional) IBRC to DPT adapter cable (optional) To implement *80810-00* P/N 80810-00-ENG 2010. Trimble Navigation Limited. All rights reserved. Trimble and the Globe and Triangle logo are trademarks of Trimble Navigation Limited, registered in the United States and in other countries. CFX-750 and Field-IQ are trademarks of Trimble Navigation Limited. Version 1.00, Rev A (December 2010). 6