Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Similar documents
Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Melrose Veteran s Memorial Middle School Auditorium 250 Lynn Fells Parkway, Melrose, MA, 02176

Arcadia Performing Arts Center Technical Specifications and Information

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Technical Services and Specification

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Dale F. Halton Theater Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Dr. Fred Speckeen Theatre. Information and Technical Specifications

STAGE ELECTRICAL 1 OF 1. - COMPANY SWITCH - SERVICE OPTIONS: - 3-Phase, 4-Wire, 208V Amps per Leg: Phase, 4-Wire, 208V

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Facility Information

NORTH CHARLESTON PERFORMING ARTS

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Technical Information

Concert Hall Technical Specifications

Marjorie S. Deane Little Theater

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

Downtown Arts Center Tech Packet. General Information

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Technical Information

Dinkelspiel Auditorium - Technical Specifications

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

Technical Specifications

CENTRE FOR PERFORMING ARTS

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

SHUBERT THEATER 247 College Street, New Haven, CT

Concert Hall Technical Specifications

General & Technical Specifications:

Technical Informa on.zack Theater

NORTH CHARLESTON PERFORMING ARTS

Technical Specifications. Taylor Little Theater

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

DOMINO THEATRE INC. THEATRE TECHNICAL SPECIFICATIONS AND INFORMATION

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Patriots Theater at the War Memorial Technical Data

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Technical Specifications and Inventory Spring 2018

Sandusky State Theatre Technical Specifications

General & Technical Specifications

SAINT ANSELM COLLEGE DANA CENTER

The Breen Center for the Performing Arts Saint Ignatius High School

Technical Specifications

Main Stage Technical Specs - Hall #2

Matt Dann Cultural Centre

Technical Capabilities of Towsley Auditorium updated February 2011 by WCC Media Services

UNIVERSITY CONCERT HALL. Technical Specification

Main House Technical Specification

EQUIPMENT AND SPECIFICATIONS -- MEZZANINE THEATRE

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Camden Opera House Theater. Technical Information

Bloomington Center for the Performing Arts. Technical Specifications

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Performing Arts Theatre

Technical Specifications

OAKLAND COMMUNITY COLLEGE

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Jane Mallet Theatre Technical Specifications

Vern Riffe Center for the Arts Technical Information Packet for Users Seating capacity Stage configuration CONCERT HALL PROSCENIUM THEATER

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Technical Data Sheet

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

FIVE FLAGS THEATER SERVICES STATEMENT

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

Technical Specifications

Technical Specification

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Dr JOHN GALLAGHER CONCERT CHAMBER

TECHNICAL SPECIFICATIONS

Schauer Arts and Activities Center Technical Information Touring Companies

NORTH CHARLESTON PERFORMING ARTS

Stephen B. Humphrey Theater

Technical Specification

Jacoby Auditorium - Technical Rider UCC Special Events Office Phone:

HORIZON STAGE TECH PACKAGE September 2018

Theatre Technical Specification

Little River Band Production Rider 2018

RPAC REDLANDS PERFORMING ARTS CENTRE

2243 Beacon Ave. Sidney, BC V8L 1W9 Phone Fax

ISLAND HALL TECHNICAL INFORMATION

ROBERT M. MERRYMAN PERFORMING ARTS CENTER TECHNICAL INFORMATION PACKET

Theatre Technical Specifications

Technical Specifications salle Léo-Poulin

Clayton Center for the Arts Ronald and Lynda Nutt Theater Technical Specifications December 2014

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

2243 Beacon Ave. Sidney, BC V8L 1W9 Phone Fax

Port Huron High School

Transcription:

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062 General Specifications Mabee Performing Arts Hall The Mabee Performing Arts Hall is located in the Bell Cultural Events Center on the campus of MidAmerica Nazarene University. The seating capacity is 545 (including wheelchair access seating spaces). It is a sloped-floor venue with three main floor seating sections and three additional sections in the mezzanine. The farthest seat from the stage is 72. Stage Measurements: Stage floor: 45 deep; 54 wide Wall-to-wall: 78 Center to SR wall: 39 Center to SL wall: 39 SR & SL wings: 12 x 31 each Proscenium width: 36 Proscenium height: 21 Grid height: 27 Stage Surface: Stage floor is flat and even. Top surface is 3/4 parquet hardwood Screws into the stage surface is prohibited Use of Rosin is prohibited Theatre Floor: Softgoods: Mabee Hall has 4 x 8 rubber sections cut to fit the apron to mid-stage traveler (32 deep by 44 wide) Valance (Memorable Black), 2 pieces @ 75% fullness 12 6 h x 31 w each Grand Curtain (Memorable Black), 2 pieces @ 75% fullness 26 h x 25 w each Traveler Mid Stage (Princess Black), 2 pieces @ 50% fullness 25 3 h x 25 w each Traveler Up Stage (Princess Black) 2 pieces @ 50% fullness 25 3 h x 25 w each Legs (Princess Black), 3 pair @ 50% fullness 26 9 h x 14 w

Borders (Princess Black) o 1 @ 6 h x 48 w o 3 @ 5 h x 48 w o 1 @ 8 h x 48 w Cyclorama (White Muslin), 25 3 h x 42 w (hung on second upstage traveler) Orchestra Shell: The shell walls are built to roll into position the front portion providing a hard proscenium creating a continuous beautiful wood surface from audience to and around stage. The following specs are with the shell in place: Proscenium width 54 Stage depth 45 Up Stage width 42 Down Stage width 54 SL wall to center 27 SR wall to center 27 Doors open to wings Headsets and Communications: Production Intercom system 2 channel, 25 person capacity at various locations All dressing rooms and make-up/green room are monitored to stage Dressing Rooms: Two large dressing rooms connected to green room and make-up area Restroom facility Small private dressing room across from green room/make-up area Other rooms may be made available as necessary for dressing room/green room space Musical Equipment: Musician chairs Music stands Choral risers (6 standing risers) Band/choral risers: 4 x 8 Conductor s podiums No special effects equipment currently available. Use of fog machine/haze machine requires administrative oversight and control. See Bell Center administration for further information.

Lighting Specifications Mabee Hall Dimmers: Controls: Circuits: 214 ETC Sensor 2.4K Dimmers Dimmer circuits are equipped with stage pin connectors except for eight grid work lights Circuits 111-132 and 183-192 are not wired Standard Edison utility outlets located along with dimmer circuits for use with color changers and effects equipment No 208v outlets as required for moving lights Lightboard: ETC Express 125/250 console ETC netware to DMX adaptors located two each SL & SR; one each grid SL & SR; one unit at house left of catwalk. 38 circuits on FOH catwalk (1-38) 10 circuits on FOH torms (51-60) 6 circiuts on DS apron floor pocket SL (39-44) 6 circuits on DS apron floor pocket SR (45-50) 25 circuits on 1 st Electric (61-85) 25 circuits on 2 nd Electric (86-110) 24 circuits on 3 rd Electric (133-156) 3 circuits in mid-stage floor pocket SL (157-159) 3 circuits in mid-stage floor pocket SR (160-162) 12 circuits in US floor pockets (163-174) 8 circuits grid work lights (175-182) 22 circuits for house lights (193-214) Lighting Fixtures in Hall: 16 19-degree E.T.C. Source Four Ellipsoidal reflector spotlights with 575-watt lamp, 14 26-degree E.T.C. Source Four Ellipsoidal reflector spotlights with 575-watt lamp, 22 36-degree E.T.C. Source Four Ellipsoidal reflector spotlights with 575-watt lamp, 20 E.T.C. Source Four PAR with 575-watt lamp, color frame, pipe clamp, safety cable, set of four interchangeable lenses and stage pin connectors

22 White E.T.C. Source Four PAR with 575-watt lamp, color frame, pipe clamp, safety cable, set of four interchangeable lenses and Edison connectors, installed as semistationary stage lighting 6 Altman #154 14 Scoop with pipe clamp, color frame 500-watt lamp, safety cable and 2P&G connector installed 5 Colortran #108-532 6, 3-circuit Cyc Strips with pipe clamp, color frames 1000-watt FHM lamps, safety cable and stage pin connectors 6 Colortran #213-512, 6 Theatre Fresnel complete with pipe clamp, color frame, safety cable, 750-watt BTN lamp and stage pin connectors Additional instruments available in Bell for use in Hall: 6 36-degree E.T.C. Source Four Ellipsoidal reflector spotlights with 575-watt lamp, 14 Colortran #213-512, 6 Theatre Fresnel with pipe clamp, color frame, safety cable, 750-watt BTN lamp and stage pin connectors 4 - Altman #154 14 Scoops with pipe clamp, color frame 500-watt lamp, safety cable and stage pin connectors Accessories: 2 Source Four drop-in Iris 2 10 light trees w/base and top eye 8 25 extension cables w/2p&g connectors 20 10 extension cables w/2p&g connectors 10 5 extension cables w/2p&g connectors

Sound Specifications Mabee Hall House Sound System: House Loud Speakers 3 - way active system 2 Proscenium line arrays configured in stereo 14 Electro-Voice XLD281 line array elements 4 Dynacord 18 subwoofers (under the stage, in stereo on the stereo bus) Mixer and Amplifiers: Monitors: Mixer: Yamaha M7CL-48 channel console Amplifiers: Electro-voice o 8 EV CPS 2.11 (house array amps) o 1 P3000RL (sub amp) o 3 EV CPS 2.6 (monitor amps) Location of house mixer: Open air control booth, mezzanine level 4 Fri-28LPM monitors 2 EV Eliminator-E monitors Six mixes available controlled from console or wireless tablet 2 Electro-Voice EVID 4.2 booth cue monitors (in mono) System Control: EV NetMax N8000 System Controller Wireless tablet PC running ElectroVoice IrisNet and Yamaha Studio Manager I/O Panels and Floor Pockets: Stage right wall panel (19 inputs / 2 returns / intercom A/B / mix 6 out) Stage left wall panel (19 inputs / 2 returns / intercom A/B / mix 6 out) 5 Stage floor pockets (1 mic in / AC Power / 1 monitor mix output) Program Source Equipment: Denon DN-C550R Mini 1/8 MP3 Player input Mac itunes & Pro/ProTools playback 4 F.O.H. Local D.I.'s 8 F.O.H. Local mic inputs

Wireless System / Microphones: 6 Shure UR4D receivers 1 Shure UA845 UHF Antenna distribution system 2 Beta87C handheld transmitters 4 Shure UR1 wireless body pack transmitters 4 - WL184 lav. mics 4 WA302 instrument cables 4 Beta 54 headsets (beige) Wired Microphones: 8 Shure Beta58A 6 Shure SM58-S 10 Shure SM86 4 Shure Microflex MX-200 B/C overhead microphones Recording System: Accessories: ProTools HD v7.3 Control 24 control surface 1 96 I/O interface 1 192 Digital I/O interface 2 MY16-AT Yamaha option cards for 24 track ProTools recording and playback Reference amp Alesis RA500 Reference monitors - Behringer Truth B231P Mac Pro w/23 Apple Cinema display 1 Shure VP88 stereo condenser microphone (mounted in catwalk) Tall boom mic-stands for all available microphones Various lengths of microphone and monitor cables 2 Subsnakes (ProCo 16x4 100 and Rapco 8x4 50 ) 4 Audio Technica ATH-M30 headphones 3 Rapco DB100 direct boxes 2 Rapco DB200 direct boxes Assistive Listening System: 1 LT-800 FM transmitter 8 Portable FM receivers available Portable System: Mackie CFX-12 2 EV-SXA100+ speakers 1 EV-SVA 760 amp 1 Denon DN-C615 CD player