Calibration Certificate

Similar documents
Certificate of Calibration

e2b calibration 521 Fifth Avenue Chardon, Ohio Phone: Fax: Certificate Of Calibration

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Calibrating attenuators using the 9640A RF Reference

R&S ZNBT Vector Network Analyzer Specifications

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Agilent 87075C Multiport Test Set Product Overview

R&S ZN-Z154 Calibration Unit Specifications

Agilent 4-Port PNA-L Microwave Network Analyzer

PAM-1840 Preamplifier Operation Manual

R&S ZVA110 Vector Network Analyzer Specifications

R&S ZND Vector Network Analyzer Specifications

SCOPE OF ACCREDITATION TO ISO 17025:2005 & ANSI/NCSL Z

MILLIMETER WAVE VNA MODULE BROCHURE

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

TEST REPORT. Test Report No. : UL-RPT-RP JD18L V2.0. Manufacturer : Neeo AG. Model No. : 6336-BRAIN FCC ID : 2AKK7-BR633601

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

USB-TG124A Tracking Generator User Manual

DA : Series of Narrowband or Wideband Distribution Amplifiers

E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors DATA SHEET

Extension kit for R&S Vector Network Analysers

Monoblock RF Filter Testing SMA, In-Fixture Calibration and the UDCK

R&S FSV-K40 Phase Noise Measurement Application Specifications

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

MULTIBAND 1/3 RACK-MOUNTED

Instruction Manual Model # Block Upconverter

Application Note DT-AN-2115B-1. DTA-2115B Verification of Specifations

R&S FS-Z60/75/90/110 Harmonic Mixers for the R&S FSP/FSU/ FSQ/FSUP/FSV

Interface Practices Subcommittee SCTE STANDARD SCTE Hard Line Pin Connector Return Loss

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE

R&S ZN-Z85 Switch Matrix Specifications

Certificate of Calibration

HP 71910A and 71910P Wide Bandwidth Receiver Technical Specifications

Advanced Test Equipment Rentals ATEC (2832)

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

DA E: Series of Narrowband or Wideband Distribution Amplifiers

AMIGO- 8VSB (ATSC) digital Modulator

PM Series Microwave Power Calibration System

R&S ZNL Vector Network Analyzer Specifications

TEST REPORT FROM RFI GLOBAL SERVICES LTD

PM Series Microwave Power Calibration System

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

FMMX9004 DATA SHEET. Field Replaceable SMA IQ Mixer From 15 GHz to 23 GHz With an IF Range From DC to 3.5 GHz And LO Power of +17 dbm.

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SMS3000X Series Spectrum Analyzer

R-1580A Microwave Downconverter. Product Brochure

1/3 RACK-MOUNTED BLOCK CONVERTERS

Indoor Dual Converter

FMMX9002 DATA SHEET. Field Replaceable SMA IQ Mixer From 8.5 GHz to 13.5 GHz With an IF Range From DC to 2 GHz And LO Power of +19 dbm.

Agilent E5500 Series Phase Noise Measurement Solutions Product Overview

Instruction Manual Model BlockUpconverter

PXI MICROWAVE. Model PXI-1420

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

R&S HA-Z24E External Preamplifier 1 GHz to 85 GHz Specifications

EMC Test Report. Client: Continental Automotive Systems, Inc. Tested by: Fendy Liauw, Engineering Technician

Features. = +25 C, IF= 100 MHz, LO= +13 dbm* Parameter Min. Typ. Max. Min. Typ. Max. Units

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors

LadyBug Technologies LLC Manual PowerSensor+ Field Certification Procedure

Application Note DT-AN DTU-315 Verification of Specifications

VXIbus Microwave Downconverter

ThinkRF D GHz RF Downconverter

ELECTRICAL TESTING FOR:

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

Model P/03P Upconverters

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

Ku-band 2W (3W typ.) Transmitter Model No. NJT5037 Type 1 (N-type Female Input Connector) Model No. NJT5037F Type 2 (F-type Female Input Connector)

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S FPC1000 Spectrum Analyzer Specifications

-Preliminary- Ku-band PLL LNB - Internal Reference (L.O. Stability: ±1 ppm) - MODEL No. NJR2835U/36U/37U/39U series

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

Product Introduction. Duplexer Box MN2555A. Signal Analyzer MS2830A. Ver.1.0

E4416A EPM-P Series Single Channel Power Meter

RF (Wireless) Fundamentals 1- Day Seminar

Keysight Technologies E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

SPECIFICATION. Spec No : VSS-1402-CS603B

R&S EDS300 DME/Pulse Analyzer Specifications

R&S FSMR Measuring Receiver All-in-one calibration of signal generators and attenuators

***** MLMS Main Test Menu Final Test Data Summary *****

Basic RF Amplifier Measurements using the R&S ZNB Vector Network Analyzer and SMARTerCal. Application Note

EMC Test Report. Client: Crestron Electronics, Inc. Tested by: Jeremy O. Pickens, Senior EMC Engineer

SPECIFICATION. DVB-T / Worldwide NIM Tuner

RF Semiconductor Test AXRF RF Port Upgrade Kits

FMMX9000 DATA SHEET. Field Replaceable SMA IQ Mixer From 4 GHz to 8.5 GHz With an IF Range From DC to 3.5 GHz And LO Power of +15 dbm.

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

EMERSON SMART WIRELESS RADIO SILENCE REPORT

FCC PART 15 CLASS B MEASUREMENT AND TEST REPORT. Tritech Technology Ltd.

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Test Procedure for Common Path Distortion (CPD)

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

Vector Network Analyzers

R&S NRPM Over-the-Air (OTA) Power Measurement Solution Specifications

How To Demonstrate Improved ACLR Dynamic Range With FSU and Noise Correction

R&S SMBV-Z1 Reference Frequency Converter Specifications

R&S Cable Rider ZPH Cable and Antenna Analyzer Specifications

Transcription:

Page 1 of 21 Description: Vector Network Analyzer Customer: Model: PLANAR-804/1 Customer Name Serial : 12095176 Address Manufacturer: Copper Mountain Technologies State-Zip Country Date of Receipt: 10 May 2016 Location of Calibration: Date of Calibration: 10 May 2016 Procedure: QMS.CAL.01 Temperature: 24.59 C Humidity: 37 % Copper Mountain Technologies 631 East New York Street Indianapolis, IN 46202 USA This calibration certificate documents that the instrument has been calibrated using applicable procedures and in compliance with (R2002). As Received Condition: The measured values of the instrument were observed IN SPECIFICATION at the points tested. Action Taken: No corrective actions were necessary to ensure the performance to published operating specifications. As Shipped Condition: At the completion of the calibration, measured values were IN SPECIFICATION at the points tested. No sampling plan or other process was used for this calibration, the results reported herein apply only to the calibration of the instrument describe above. All calibrations are performed to manufacturer s specifications, unless otherwise noted. This certificate may contain data that is not covered by the ANAB scope of accreditation. The unaccredited material, where applicable, is indicated by an asterisk (*) or confined to clearly marked sections. This certificate shall not be reproduced except in full, without the approval of Copper Mountain Technologies. Based on the customer's request, the next calibration is due on 10 May 2017. Authorized by: RCD.041 rev.1 Technician Senior Technician

Page 2 of 21 Compliance with Specification: The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor k such that the coverage probability corresponds to approximately 95 %. The uncertainty is accounted for in the determination of the test limits for compliance to specification. If the manufacturer has a specified tolerance for this instrument, then the calibration results, within our uncertainty value added, are compared to this tolerance, and the combined value. Traceability Information: Measurements are traceable to the International System of Units (SI)) via national metrology institutes (i.e. NIST, NPL, PTB, SNIIM, etc.) that are signatories to the CIPM Mutual Recognition Arrangement. Calibration Equipment Used: Type Model Description Serial W W W 53181A E4407B NRP-Z51 Frequency Counter Spectrum Analyzer Thermal Power Sensor Trace Value MY40001952 TME-29781 22 Feb 2017 Frequency SG44210601 151201-080518- b10ec4_r1 14 Dec 2016 Frequency 103288 TME-29775 22 Feb 2017 RF Power W 05CK010-150 Calibration Kit CL005 4-246 13 April 2017 W, R 05AS122- K40S3 Attenuator 40 db 15746 4-247 13 April 2017 Reflection Transmission Reflection Transmission W, R NKZ-18-11 Short 2215060001 4-247 13 April 2017 Reflection W Working Standard: measurement standard that is used routinely to calibrate or verify measuring instruments or measuring systems (JCGM 200:2012 VIM3). R Reference Standard: measurement standard designated for the calibration of other measurement standards for quantities of a given kind in a given organization or at a given location (JCGM 200:2012 VIM3).

Page 3 of 21 Test Summary Environmental Conditions Temperature: 24.59 C Humidity: 37 % Description Visual inspection Lower limit Measured value Upper limit MU Gaging connectors * Port 1 Port 2 CW frequency accuracy: 0.3 MHz 8000 MHz Output power level accuracy 5.18 mm 5.18 mm 299998.5 Hz 7999960000 Hz 5.26 mm 5.26 mm 300000.2 Hz 8000005792.0 Hz 5.26 mm 5.26 mm 300001.5 Hz 8000040000 Hz ±0.03 Hz ±800 Hz -1.5 db 0.25 db 1.5 db ±0.15 db Harmonic distortion * -28.9 dbc -25 dbc Non-harmonic spurious * -40.0 dbc -30 dbc Receiver Noise Floor (IF bandwidth 10 Hz) *: Trace Noise *: Uncorrected parameters: Directivity Source match Load match 15.0 db 18.0 db 18.0 db 18.0 db -127.5 dbm -126.3 dbm 0.00451 db 0.00057 db 16.8 db 21.7 db 19.1 db 19.0 db -105.0 dbm -125.0 dbm 0.010 db 0.001 db ±0.22 db ±0.38 db ±0.28 db ±0.28 db

Page 4 of 21 Description Lower limit Measured value Upper limit MU Transmission coefficient magnitude error: -40 db -60 db Transmission coefficient phase error: -40 db -60 db Reflection coefficient magnitude error: High reflection Low reflection Reflection coefficient phase error: High reflection Low reflection -0.2 db -0.1 db -1.0 db -0.2 db -2.00-1.00-6.00-2.00-0.400 db -3.000 db -3.00-20.00-0.02 db -0.06 db -0.08 db -0.09 db -0.22 0.38-0.52-0.46 0.017 db -0.109 db 0.16 0.66 0.2 db 0.1 db 1.0 db 0.2 db 2.00 1.00 6.00 2.00 0.400 db 3.000 db 3.00 20.00 ±0.05 db ±0.05 db ±0.05 db ±0.05 db ±0.53 ±0.53 ±0.53 ±0.53 ±0.086 db ±1.266 db ±0.56 ±6.22

Page 5 of 21 PLANAR 804/1 Serial : 12095176 Date: 10 May 2016 Visual Inspection Test standards and required equipment Model Description Serial No traceable test standards or equipment are required for this test Description The connectors do not have any mechanical damage There are no deep scratches or dents in the analyzer housing There is no sound in the housing due to loose components The label markings are legible Statement of compliance YES YES YES YES

Page 6 of 21 PLANAR 804/1 Serial : 12095176 Date: 10 May 2016 Gaging Connectors Test standards and required equipment Model Description Serial No traceable test standards or equipment are required for this test Port PORT 1 50 type N, female PORT 2 50 type N, female Lower limit [mm] Measured value [mm] Upper limit [mm] 5.18 5.26 5.26 5.18 5.25 5.26

Page 7 of 21 PLANAR 804/1 Serial : 12095176 Date: 10 May 2016 Frequency Accuracy Test standards and required equipment Model Description Serial 53181A Frequency Counter MY40001952 TME-29781 22 Feb 2017 E4407B Spectrum Analyzer SG44210601 151201-080518- b10ec4_r1 14 Dec 2016 Port Frequency [MHz] Lower limit [Hz] Measured value [Hz] Upper limit [Hz] Measurement Uncertainty [Hz] 1 0.3 299998.5 300000.2 300001.5 ±0.03 1 8000 7999960000 8000005792.0 8000040000 ±800

Page 8 of 21 PLANAR 804/1 Serial : 12095176 Date: 10 May 2016 RF Output Level Accuracy Test standards and required equipment Model Description Serial NRP-Z51 Thermal Power Sensor 103288 TME-29775 22 Feb 2017 Port RF Output Level [dbm] Max Power Error [db] Specification [db] Measurement Uncertainty [db] 1 0-0.04 ±1.5 ±0.15 1 10 0.18 ±1.5 ±0.15 1 5-0.04 ±1.5 ±0.15 1-10 0.05 ±1.5 ±0.15 1-55 0.23 ±3.0 * 1-60 0.06 ±1.5 * 2 0 0.11 ±1.5 ±0.15 2 10 0.25 ±1.5 ±0.15 2 5 0.11 ±1.5 ±0.15 2-10 0.11 ±1.5 ±0.15 2-55 -0.14 ±3.0 * 2-60 0.15 ±1.5 *