Operating Instructions

Similar documents
Electrical connection

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Electrical connection

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

Electrical connection

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Electrical connection

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Q3X Laser Contrast Sensor

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

SU17 Series Fiber Optic Sensors

Electrical connection

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

Q3X Laser Contrast Sensor

MICROMASTER Encoder Module

Q3X Laser Contrast Sensor

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Single Axis Position Controller

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Electronic Pulse Counter Combination device

Photoelectrics Through-beam Type PA18C.T..., DC

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

Operating instructions Electronic preset counter Type series 717

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

V 180 Series Photoelectric Switches

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

Noise Detector ND-1 Operating Manual

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Transmitter optics with 9x white light LED (optics cover made of glass)

EZ Encoder : Optical Incremental (P Series)

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Users Manual. Stroboscope. September 2014

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

Material: Weight: IP Rating: Cable: Connector:

WF next: Fork sensors for a wide range of applications

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

TimeView Display. Operating Manual

Revision 1.2d

Registers type ILR7XX and ILR7XXT

APPLICATIONS. Automatic warehouse. Trasportation lines

Capacitive sensor BCT5-S18-UP6X2T-H1151

Time meter electronic

Hour Meters / Timers, electronic

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

800 Displaying Series Flowmeter

APPLICATIONS. Automatic warehouse. Trasportation lines

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

DF-G3 Long Range Expert Dual Display Fiber Amplifier

Light Curtain Type LA

263 Series LED Bargraph Indicator and Controllers

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

Smart-Encoder : Optical Incremental

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Amplifier for fiber optics. Dimensioned drawing

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Process Transmitter RMA 422

Wall-/Pipe-Mount Level Indicator

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Technical data. General specifications. Indicators/operating means

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Tech Support: Customer Service: General Tech Questions: Tech Docs:

True Color Sensor with Analog and Digital Outputs

RLS Series RLS-GD-20/20. Design. RLS Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

Standard signal metering in wall-mounting case

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

SceneStyle2 User Guide

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

DF-G2 High Speed Expert Dual Display Small Object Counter. Instruction Manual

FRQM-2 Frequency Counter & RF Multimeter

Data Sheet SPECTRO-3-SLU-BA-ANA + SI-SLU-16. Receiver optics incl. 3-color filter detector (True Color), scratch-resistant optics cover made of glass

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

SPECTRO Series SPECTRO-3-5-DIF-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

SPECTRO Series SPECTRO-1-50-DIL. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

KHT 1000C HV-Probe Calibrator. Instruction Manual

IEFIS G3 Inputs, outputs and Alarms

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

PSM-003. Micro Polarization Controller/Scrambler. User Guide

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Transcription:

CNTX Contrast sensor Operating Instructions

CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target surface. This will prevent direct reflected signal from glossy surfaces. To obtain maximum tolerance to distance variation, place the target at the greatest distance it is likely to be in the application, for example, flat against a guide surface. Carefully adjust the sensor distance to obtain the highest reading on the white background and note the reading. Now move it slightly further away, to get approximately 5% lower reading and fix sensor at that distance. This will allow the target to move closer, back to the highest reading, then closer still down to 5% lower. The result should be a minimum of 2mm of allowable flutter with <5% change in reading. CAUTION: CAUTION: The discrete output must not be connected to outputs from other sensors (i.e. outputs from multiple sensors must not be connected in parallel). Parallel connections may damage sensor output circuitry. Sensor is not suitable for wash down or hazardous environments; a separate enclosure with the appropriate ratings is recommended for these applications" IMPORTANT: This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death. CERTIFICATIONS: ETL, CE, CSA ETL, CE, and CSA certifications are in process. CNTX Operating Instructions 2

PRODUCT OVERVIEW The CNTX sensor combines small spot size and fast response to achieve high-speed contrast detection capable of detecting a wide variety of marks and objects. The CNTX effectively detects contrast differences between many colors on various surfaces over a range of 50 grayscale levels. The modulated white light source in the CNTX is focused to a 2.5 to 3mm spot and directed toward a target. The diffused light returning to the sensor is measured. When the level is equal to or exceeds the threshold the discrete output changes state. Due to the fast response of the sensor, it is suitable for use in high-speed applications. The sensor provides a discrete output that automatically configures to NPN and PNP. A PLC or a computer can be used to monitor the status of the discrete output signal. The CNTX is a reliable, compact sensor with high-speed sensing capabilities. Two seven segment displays provide visual representation of the relative intensity from 00 to 50. The gain feature and 3 LED intensity settings provide for flexible operation over a wide range of colors. Specifications White light source Broad spectrum LED, min.100,000 hours Sensing distance 26mm Spot size (dia.) 3mm Depth of field +/-3 mm from focal point (approx. 28mm) Response time 25uS Switching Frequency 40kHz LED Intensity 3 levels Relative intensity display range 00 to 50 Sensitivity X1, X10 Signal level Two 7 segment digits Detection threshold Two 7 segment digits Digital Output Auto-Detect PNP / NPN Output Function NO/NC selectable Analog output 0 5V (% of full-scale, 20mV resolution) Security LOCK / UN-LOCK keypad Power indicator Green LED Detect indicator Red LED Programming indicator Yellow LED Data retention EEPROM non volatile memory Dimensions 2.0 (51mm) x 2.4 (61mm) x 1.0 (25mm) Weight 0.21 lbs. (95 g) Supply Voltage 10 24 VDC Operating Current 60 ma Short Circuit Protection Discrete output Overload / Reverse Polarity Protection Supply voltage Operating temperature -20ºC 55ºC Storage temperature -20ºC 70ºC Housing Metal alloy Mechanical protection IP65 NOT FOR PRESSURE WASHDOWN CNTX Operating Instructions 3

QUICKSTART GUIDE 1. The display range is 00 through 50. The decimal points indicate the LED intensity level. The RED LED above the display indicates that the intensity level drops below the threshold setting. 2. Connect cable to power supply observing correct polarity. Reference wiring diagram. 3. Apply power; sensor will initialize and perform its power up sequence. 4. To obtain maximum tolerance to distance variation, place the target at the greatest distance it is likely to be in the application, for example, flat against a guide surface. Select the target area for the presence or non-presence, depending on which condition yields the higher signal level. Carefully adjust the sensor distance to obtain the highest reading in this pre-determined area and note the reading. Now move the sensor slightly further away, to get approximately 5% lower reading and fix sensor at that distance. This will allow the target to move closer, back to the highest reading, then closer still down to 5% lower. The result should be a minimum of 2mm of allowable flutter with <5% change in reading. 5. Place a sample (or use the back cover of this manual) with background into the sensor spot and note the reading, move the sample 2 nd area or condition that the sensor will encounter and note the reading. Set the threshold between these 2 values. 6. Various adjustments may be made to increase or decrease sensitivity; refer to the Sections Calibration Adjustment and LED Intensity Level. Refer to Section: Threshold, to alter threshold setting. 7. User programmable parameters are discussed in detail in the following sections. OPERATION Power up Upon power up, the sensor initializes by turning on all segments on the display and sequencing through red, yellow and green on the status LED located above the display. Intensity display mode Threshold During normal operation the sensor display will indicate the relative intensity of a target within its field of view. The range of the relative intensity display is 00 through 50. The decimal points on the display indicate the LED output intensity. No decimal points indicate low, one decimal point indicates medium and two decimal points indicate high intensity. When the relative intensity level exceeds the threshold setting the red status LED will turn on and the discrete output will activate, indicating detection of the target. When the relative intensity level drops below the threshold (as determined by the hysteresis setting), the red LED will extinguish and the discrete output will de-activate. The threshold setting allows the user to select the detection level. The default setting is 15. While the current threshold is shown on the display, press the + or key to increase or decrease the setting, then wait several seconds for the sensor to return to the normal intensity display mode. Local Lock The local lock feature allows the sensor to be locked out, preventing adjustments by unauthorized personnel. To lock the sensor, press the P/- and T/+ buttons for 3 seconds until LL is displayed. To un-lock the sensor, press the T/+ and P/- for 3 seconds until LL is not displayed. While the sensor is locked, pressing either P/- or T/+ will result in LL (Local Lock) indication on the display. CNTX Operating Instructions 4

Programmable Parameters All adjustments made to these parameters are stored in memory and are retained when power is removed. To enter programming mode press and hold the P/- key for several seconds, the current threshold setting will be displayed. Press and release the P/- key to scroll through the various settings. Press and release the T/+ key to change a particular setting. Press and hold the P/- for several seconds to return to the normal intensity display mode. The user programmable items are described below. LED Intensity Level (U) The LED intensity is indicated on the display as U1, U2 and U3 for low, medium and high intensity. Press and release the T/+ key to toggle through the 3 intensity levels. The default setting is U2, medium intensity. Hysteresis Level (H) The hysteresis setting is indicated by H0 through H9. The hysteresis level is how far above the threshold the signal increase to de-activate or un-detect. The hysteresis can be set from 0 to 9. For example, if the threshold is set at 25 and the drops to 25 or lower, the sensor will detect and activate its output. With the hysteresis set to 4, the signal must increase to 30 to un-detect. This feature is useful in cases where there may be variation within a target that might cause the intensity to increase above the threshold slightly; the hysteresis allows the output to remain activated until the level increases significantly. Press and release the T/+ key to change the hysteresis setting. The default setting is 2. Discrete Output Configuration This setting allows the user to select either normal open (no) or normally closed (nc) configuration. The normally open configuration de-activates the output during normal un-detect operation, and activates the output upon detect. The normally closed configuration activates the output during normal un-detect operation, and de-activates the output upon detect. Press and release the T/+ key to toggle through the selections. Default is normally open. Extend Output Pulse (P) This feature allows extending the minimum length of time that the discrete output remains active following target detection. The sensor response can be in the 25uS (microsecond) range, i.e. a target can move through the sensing range in 25uS and the discrete output would active for only that duration. A slower acquisition system (PLC) may not sample its inputs at a fast enough rate to capture the signal. The discrete output pulse can be extended from 0 to 90mS (milliseconds) in 10 ms increments as indicated by P0 though P9 on the display. Press and release the T/+ key to toggle through the selections. Null Offset (nu) NOTE: Always perform the null function when changing LED intensities. The null feature allows the sensor to be zeroed. Aim the sensor away from any target, press and hold the T/+ key to null the sensor. The display will flash the value that is being subtracted. Gain Adjustment (r) To change the gain setting press and release the T/+ key to toggle through the selections. R1 indicates a gain of 1; R2 indicates a gain of 10. The selected gain is stored in memory and is retained when power is removed. After changing the gain setting always perform the null offset (nu nu) to re-zero the sensor. CNTX Operating Instructions 5

Teach Function The teach function allows the user to set the threshold by placing a representative target located at the required distance and allowing the sensor to determine the optimum LED intensity and setting of the threshold level. SELECT TWO LOCATIONS ON THE SAMPLE: The sensor will set a threshold point between the two locations on the sample that are positioned in front of the sensor in step 2 and 3 below. Examine the sample and determine the two locations on the sample that will be used to teach the sensor. Step 2 must always be the lighter of the two locations. For example, to detect any color marks on a white paper, use the white paper in step 2 and the lightest mark in step 3. This will allow the sensor to set a threshold between the white and the lightest mark thereby allowing all darker marks to be detected. 1. Press and hold the T/+ key for several seconds until the yellow led flashes. 2. Place the lightest area of the sample at the appropriate distance from the sensor and press the P/- key. The display will flash 3 times and the sensor will adjust the LED intensity level to achieve reasonable signal level. The green LED will flash. 3. Place the darker area of the sample in the sensor s light spot and press the P/- key. The display will flash 3 times. 4. Exit the teach function and return to the normal operating mode by Pressing the T/+ key for several seconds. Use the normally open (NO) and normally closed (NC) feature in the set-up menu to set the output logic when necessary (refer to the Discrete Output Configuration section for details). When in the teach mode the LED flashes constantly, yellow, green or red. Yellow indicates that the sensor is ready to be taught the Detect level. Green indicates that the sensor is ready to be taught the Undetect level. Red indicates that the last attempt to teach resulted in an error. If the error occurred during the teaching of the Detect level then the signal intensity was less than 01. If the error occurred during the teaching of the Undetect level, then the signal intensity was greater than or equal to the threshold level. In either case, repeat the teach function to properly set the levels. Output Signals Discrete Output The discrete output is a PNP/NPN configuration allowing the user to provide a load on this output that is either pulled high to VDC or low to ground. The sensor monitors this level and automatically determines whether to operate the PNP/NPN driver. This output is typically connected to a PLC. The output remains active as long as the intensity level exceeds the threshold, in high-speed applications it may be useful to use the Extend Output Pulse feature to lengthen the signal duration to meet acquisition requirements of the PLC. CAUTION: The discrete output must not be connected to outputs from other sensors (i.e. outputs from multiple sensors must not be connected in parallel). Parallel connections may damage sensor output circuitry. Analog Output The analog output is 0-5V with 20mV resolution (8-bit). Any standard analog input channel typically available on a PLC may monitor this output. The analog output signal is useful in applications where simply triggering on the threshold is insufficient. For example, constant real-time monitoring of intensity in process allows minor fluctuations or trends to be detected permitting corrective action to CNTX Operating Instructions 6

be taken. The analog output response time is slower than the discrete output response time and should be evaluated per the requirements of each application. Remote Lock/Unlock Input The remote lock feature allows the user to lock out the local controls (keys) to prevent operators from making unauthorized adjustments. This signal line must be connected to VDC to lock the sensor. This line may be left unconnected if the lock feature is not used. While the sensor is locked, pressing either P/- or T/+ will result in rl (remote Lock) indication on the display. Sensor-to to-target target distance variation CNTX sensor-to-target distance variation Relative response (normalized) 1.20 1.00 0.80 0.60 0.40 0.20 0.00-4.0-3.0-2.0-1.0 0.0 1.0 2.0 3.0 4.0 Off-focus distance (mm) CNTX Operating Instructions 7

Display Indicators Indicators Green LED Threshold Mode while in Undetect Red LED Detect Yellow LED Threshold Mode while in Detect Display decimal points None illuminated LED low intensity One illuminated LED medium intensity Two illuminated LED high intensity T/+ P/- M12 connector pin assignments M12 Connector Wire Color Description Pin 1 Brown Power 10 to 24VDC Pin 2 White Discrete output, PNP/NPN, NO/NC Pin 3 Blue Ground Pin 4 Black Analog output Pin 5 Yellow Remote lock CNTX Operating Instructions 8

Ordering information CNTX-30 30-0 Contrast sensor Accessories UVX300-BRKT UVX 300-C Bracket 5 meter cable with M12 5-pin connector CNTX Operating Instructions 9

Dimensional Details Sensor I/O Connections CNTX Operating Instructions 10

Warranty CNTX Operating Instructions 11

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America WEB http://www.emxinc.com E-mail salessupport@emxinc.com Telephone (216) 518-9888 Fax (216) 518-9884 CNTX test pattern Revision 1.4 12.1.12 CNTX Operating Instructions 12