Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed

Similar documents
MASTER DIALOG ERM 8-20kVA three/single phase ERT kVA three/three phase

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower

Engineered to meet your needs T he oldest name in stud welding,

Stud Welding Equipment

CONSUMER UPS SINGLE PHASE UPS UP TO 3000 VA THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

ULTRALOW TEMPERATURE FREEZERS -86 C

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

SCALE & WEIGHT DISPLAYS

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

OPERATING AND SAFETY INSTRUCTIONS for DIGITAL TEMPERATURE CONTROLS (PLSM SERIES)

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Durable and Reliable Design for 24/7 Use. Overview. Narrow Bezel Optimized for Video Walls. 42 Narrow bezel commercial LED display

Prisma Optical Networks Ancillary Modules

PRELIMINARY Sunny Boy 240-US

X-Band Redundant LNB Systems

ADJUSTABLE SPEED DRIVES. nc1 Drive

Model KT 53 Cooling incubators with thermoelectric cooling

Ku-Band Redundant LNB Systems

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

C-Band Redundant LNB Systems

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Forced Convection Laboratory Ovens

Agilent 87075C Multiport Test Set Product Overview

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

COHERENCE ONE PREAMPLIFIER

SPECIFICATION NO Model 207 Automatic GTAW Welding System

MAP110 AC-DC Series Data Sheet

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

Directional Couplers and Splitters

Hitachi Kokusai Electric Comark LLC

Model KBF 115 Constant climate chambers with large temperature / humidity range

Natural-sounding telephone audio... Hybrids

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

SPECIFICATION NO NOTE

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

P Output Ratings. Dimensions and Weights. Prime Rating

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P550-3L. Output Ratings. Dimensions and Weights. Prime Rating

Catalogue Ignitors and power switches for HID

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

LED Driver Linear / area fixed output

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

Dynatel Advanced Cable Locator 2250

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

Thermo Scientific NESLAB ThermoFlex Recirculating Chillers

P400-3L. Output Ratings. Dimensions and Weights. Prime Rating

multi-function meters

Fluid Cooling P-BAR b Industrial BOL Series

16W Ku-band Matchbox BUC

LED Driver Compact fixed output

Product Brochure. June M5 Series. Metal Detector

P Output Ratings. Dimensions and Weights. Prime Rating

SOLID STATE UNINTERRUPTIBLE POWER SUPPLY

AF-300 E11 Adjustable Frequency Drive

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

P1000P1/P1100E1 50Hz

Model KT 170 Cooling incubators with thermoelectric cooling

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

Harmonic correction unit (HCU2)

P1350P1/P1500E1 50Hz

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

Model KBF 1020 Constant climate chambers with large temperature / humidity range

SAL Series Wireless Clock (V1)

APQ Series Type C Power Factor Correction Banks

LED Driver Compact fixed output

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

PCR AUTOMATIC HEAT TREATMENT CONSOLE

Magnum Panel Systems. UL1741 Interconnection System Equipment. The Powerful Difference

Indoor Linear 80W Driver SI-C215280N2KR

Modular Block Converter Systems

LED Driver Compact fixed output

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Colour Explosion Proof Video Camera USER MANUAL VID-C

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

clipping; yellow LED lights when limiting action occurs. Input Section Features

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

ED5229GT-E Series. Page 1 of 8

Re-defining the utility-scale inverter

ED5229GT-E/GTRE Series

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

Ultra Quiet Series Electric Air Handler

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

Transcription:

R A H I G H E R L E V E L O F C O N F I D E N C E Chloride EDP Series Three-Phase UPS (12-3000 kva): The EDP Series UPS is designed for commercial users who require versatility for today s application and flexibility for tomorrow s growth. Field upgradeable technology allows for easy scalable power and runtime upgrades as well as N+1 distributed or centralized paralleling on your premise. EDP Series UPS The Chloride EDP Series UPS features true on-line protection providing top security, top reliability, and top quality power. The EDP Series UPS delivers excellent unbalanced load performance with a 3:1 crest factor, including a proven design that more precisely stabilizes both voltage and frequency. Advanced technology The EDP series constantly supports the load and protects against the full range of power line disturbances that shorten the service life of critical systems. State-of-the-art design technology along with sophisticated controls assure a high mean-timebetween-failure (MTBF). The EDP Series UPS boasts over 275,000 hours MTBF. EDP70Plus (12-36 kva) EDP70Plus (50-80 kva) Superior reliability The EDP Series is easy to install, operate and maintain. Superior reliability is achieved with the use of an individual rectifier, inverter, static switch and monitoring control circuitry. The Chloride EDP Series can be used to protect any type of critical load and can be custom-configured to meet specific needs. Automatic battery monitoring Automatic battery monitoring ensures battery back-up reliability. Monitoring detects an open battery cell or a deteriorated cell. It also communicates preset limit conditions on the LCD front panel display. Temperature compensated charging eliminates the possibility of thermal runaway. EDP70 L (80-250 kva) EDP90 (225-3000 kva) Automatic restart: for fast recovery. Superior microprocessor design: provides clean sinusoidal output. High efficiency: means lower operational costs. Scalable power and runtime: for growth. Advanced battery management technology: improves battery life by 20%. Internal maintenance bypass: allows dual feed capability. Fully rated static switch: for trouble-free switching at full load. Harmonics tolerant: supports new linear loads directly. Small footprint: saves space. Optional LIFE2000 remote monitoring and preventative maintenance service: 24/7/365 monitoring by the Chloride Control Center. Optional MopUPS UPS software: for safe system shutdown and remote manageability. Full 1-year warranty on UPS: ensures product quality and performance. A Chloride Power Protection Company

Advanced communications All EDP Series UPSs are equipped for real-time information transmission and interface to SCADA or building management systems. ONEAC MopUPS software features complete local monitoring and measurement of all UPS events. User-friendly front panel display The EDP s user-friendly front panel display has over 50 plain language messages in 5 different languages French, English, German, Spanish and Italian. Ease-of-use features include push-button selectors and arrows to scroll through menus. The mimic panel and operator buttons represent the flow diagram with international electrical symbols for rectifier, battery, inverter, static switch and bypass (reserve) supply. The front panel also features LCD visual status and audible alarms. Audible alarm cancellation and inverter start/stop can be turned on and off separately. MopUPS Monitors and Measures All UPS Events The ManageUPS NET SNMP/Web adapter allows the EDP to reside as a node on your network or as a web page on your Intranet. LIFE2000 monitoring and preventive maintenance program links your UPS to our 24/7 control center. The sophisticated chipset allows our diagnostic engineers to examine your UPS to proactively identify a device-specific condition before it becomes a problem. This service can be custom configured to meet end user requirements for reporting, notification and intervention. Certifications and approvals The EDP Series UPS is listed under ETL/UL 1778. A versatile solution for a wide range of applications The EDP s design provides a versatile power protection solution. With it s expandability and upgradeability, the EDP Series UPS is a logical choice for: Financial and Banking Insurance Accounting Universities Hospitals Research Laboratories Industrial Petro-Chemical Pharmaceutical Metals Machine Tool Plastics Data Centers Communication Services ISP s Call Centers Credit Card Processing Centers And more Comprehensive, Multi-lingual Front Panel Display Batteries Advanced battery care is at the heart of the EDP design. Battery care features include temperature compensation, ripple current limit, end-ofdischarge voltage/time compensation and automatic disconnect (or, for the 70L model, automatic shut-off) of the battery circuit at end-ofdischarge (E-O-D). Scheduled automatic battery testing ensures operability and service life. Battery cabinets specifications Cabinet type A dimensions: 17.8 W x 28.7 D x 55.9 H Cabinet type B dimensions: 33.6 W x 28.7 D x 55.9 H Cabinet type C dimensions: 34.0 W x 33.0 D x 70.0 H Cabinet type D dimensions: 40.0 W x 33.0 D x 70.0 H Nominal DC voltage is 480 VDC or 288 VDC. Battery life is optimized at 25 C (77 F). For every 8 C (15 F) above optimum temperature, battery life is reduced by 50%.

EDP70Plus 12-24 kva: Specifications Standard features Internal Maintenance Bypass Dual Input Capability On-Site Capacity Upgradeability Redundant Cooling Fans for Increased Reliability Casters for Ease of Installation Pulse Width Modulated IGBT Inverter Temperature Compensated Battery Charger Secure Battery Test Generator Friendly 0.8 Input Power Factor RS232C and AS/400 Communication Ports Dual RS232 - via Multicomm Multilingual LCD Display On-Site Warranty Input and Output Circuit Breakers EPO Switch Options LIFE2000 24-Hour Monitoring Service 10% Input Harmonic Filter (no additional cabinets) External Maintenance Bypass Extended Runtime and Matching Battery Cabinets MopUPS Network Shutdown Software ManageUPSNET SNMP/WEB Adapter Remote Alarm Panel Spare Parts Kits Extended Warranties Preventive Maintenance Inspection Packages Remote EPO Switch EDP70Plus Model 24 Model 24-12 kva Model 24-18 kva Model 24-24 kva 2x2 4x2 4x4 2x2 4x2 4x4 2x2 4x2 4x4 kva/kw @.67 PF 12/8 12/8 12/8 18/12 18/12 18/12 24/16 24/16 24/16 Input Voltage 208Y/120 480 480 208Y/120 480 480 208Y/120 480 480 Output Voltage 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz Nominal Input Current 37 16 16 57 25 25 76 33 33 Maximum Input Current 42 19 19 60 26 26 78 34 34 Nominal Output Current 33 33 14 50 50 22 67 67 29 System Efficiency 100% 88 87 86 88 87 86 88 87 86 Full Load Heat Refection (BTU/hr) 3750 4150 4550 5460 6200 6600 6800 7500 8200 Height - In. (cm) 56 (142) 56 (142) 56 (142) 56 (142) 56 (142) 56 (142) 56 (142) 56 (142) 56(142) Width - In. (cm) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) Depth - In. (cm) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) Net Weight lbs (kg) 900 (408) 1200 (544) 1400 (635) 900 (408) 1200 (544) 1400 (635) 900 (408) 1200 (544) 1400 (635) Shipping Weight - lbs (kg) 1100 (500) 1400 (636) 1600 (727) 1100 (500) 1400 (636) 1600 (727) 1100 (500) 1400 (636) 1600 (727) BATTERY CABINET EDP70PLUS MODEL 24 BATTERY BATTERY BATTERY Pack Type 12 kva 18 kva 24 kva NET WEIGHT SHIP WEIGHT PACK WIDTH RUNTIMES IN MINUTES* lbs (kg) lbs (kg) Inches (cm) 106** Internal 38 26 18 660 (299) internal 0** 107C 1 x A 38 26 18 900 (408) 1100 (500) 17.8 (45) 108C 1 x A 73 44 29 1,050 (476) 1250 (568) 17.8 (45) 109C 1 x B 88 55 39 1,650 (748) 1850 (841) 33.5 (85) 114C 1 x B 105 62 46 1575 (716) 1775 (807) 33.5 (85) 116C 1 x B 123 79 54 2165 (984) 2365 (1075) 33.5 (85) 131C 1 x B 196 91+ 64 2,100 (953) 2300 (1045) 33.6 (85) * Runtimes based on ambient temperature of 77 F (25 C, 1.67 final volts/cell). Maximum cable length between battery cabinet and UPS should not exceed 30 feet. Additional runtimes available, consult factory. **Internal battery packs are available only on units with 208 V input and 208 Y/120 V output configurations. NOTE: All runtimes are approximate and based on 1.67 final volts/cell, 77 F, and 0.8 power factor at end of discharge, unless otherwise noted. Actual runtimes may vary.

EDP70Plus 24-80 kva: Specifications Standard features Internal Maintenance Bypass Dual Input On-Site Capacity Upgradeability Redundant Cooling Fans for Increased Reliability Casters for Ease of Installation Pulse Width Modulated IGBT Inverter Temperature Compensated Battery Charger Secure Battery Test Generator Friendly 0.8 Input Power Factor RS232C and AS/400 Communication Ports Multilingual LCD Display On-Site Warranty Dual RS232 - via Multicomm Input and Output Circuit Breakers EPO Switch EDP70Plus Model 36 Model 36-24 kva Model 36-30 kva Model 36-36 kva 2x2 4x2 4x4 2x2 4x2 4x4 2x2 4x2 4x4 kva/kw @.67 PF 24/18 24/18 24/18 30/20 30/20 30/20 36/24 36/24 36/24 Input Voltage 208Y/120 480 480Y/277 208Y/120 480 480Y/277 208Y/120 480 480Y/277 Output Voltage 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz Nominal Input Current 75 33 33 93 40 40 112 49 49 Maximum Input Current 78 34 34 97 42 42 118 51 51 Nominal Output Current 67 67 29 83 83 36 100 100 43 System Efficiency 100% 89 89 89 89 89 89 89 89 89 Full Load Heat Refection (BTU/hr) 7700 7700 7700 9500 9500 9500 11300 11300 11300 Height - in (cm) 56 (142) 56 (142) 56 (142) 56 (142) 56 (142) 56 (142) 56 (142) 56 (142) 56 (142) Width - in (cm) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) 27.5 (70) Depth - in (cm) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) 28.7 (70) Net Weight - lbs (kg) 1300 (590) 1300 (590) 1300 (590) 1300 (590) 1300 (590) 1300 (590) 1300 (590) 1300 (590) 1300 (590) Ship Weight - lbs (kg) 1500 (682) 1500 (682) 1500 (682) 1500 (682) 1500 (682) 1500 (682) 1500 (682) 1500 (682) 1500 (682) BATTERY CABINET EDP70PLUS MODEL 36 RUNTIMES* EDP70PLUS MODEL 50 RUNTIMES* Pack Type 24 kva 30 kva 36 kva 30 kva 40 kva 50 kva NOTE: Battery life is optimized at 25 C (77 F). For every 8 C (15 F) above optimum temperature, battery life is reduced by 50%. All runtimes are approximate and are based on 1.67 final volts/cell (final volt per c 129C 1 x A 16 min. 10 min. 8 min. 110C 1 x A 33 min. 24 min. 21 min. 111C 1 x B 57 min. 44 min. 35 min. 112C 1 x A & 1 x B 83 min. 63 min. 53 min. 120 C 1 x C 83 min. 63 min. 53 min 401 1 x E. 22 min. 14 min. 10 min. 402 1 x F 35 min. 23 min. 17 min. 403 1 x E & 1 x F 53 min. 38 min. 28 min. 404 1 x C 53 min. 38 min. 28 min. 405 1 x C 64 min. 44 min. 33 min. 406 1 x D 79 min. 54 min. 40 min. 407 2 x C 128 min. 86 min. 65 min. 408 2 x C 149 min. 109 min. 82 min. + Not line-up and match cabinets. * Additional runtimes available, consult factory. NOTE: Nominal DC voltage is 480 VDC (240 cells/cabinets).

Options 10% Input Harmonic Filter (no additional cabinets) LIFE2000 24-Hour Monitoring Service External Maintenance Bypass Extended Runtime and Matching Battery Cabinets Mopups Network Shutdown Software Remote EPO Switch ManageUPSNET SNMP/WEB Adapter Remote Alarm Unit Spare Parts Kits Extended Warranties Preventive Maintenance Inspection Packages EDP70Plus Model 50 Model 50-30 kva Model 50-40 kva Model 50-50 kva 2x2 4x2 4x4 2x2 4x2 4x4 2x2 4x2 4x4 kva/kw @.8 PF 30/24 30/24 30/24 40/32 40/32 40/32 50/40 50/40 50/40 Input Voltage 208 480 480 208 480 480 208 480 480 Output Voltage 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz Nominal Input Current 115 50 50 127 55 55 157 68 68 Maximum Input Current 132 57 57 152 66 66 192 83 83 Nominal Output Current 83 83 36 111 111 48 138 138 60 System Efficiency 100% 87 88 88 87 88 88 87 88 88 Full Load Heat Refection (BTU/hr) 10600 10100 10100 12800 12100 12100 15200 14300 14300 Height - in (cm) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) Width - in (cm) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) Depth - in (cm) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) Net Weight - lbs (kg) 1670 (759) 1350 (612) 1350 (612) 1670 (759) 1350 (612) 1350 (612) 1670 (759) 1350 (612) 1350 (612) Ship Weight - lbs (kg) 1870 (850) 1550 (704) 1550 (704) 1870 (850) 1550 (704) 1550 (704) 1870 (850) 1550 (704) 1550 (704) EDP70Plus Model 80 Model 80-50 kva Model 80-65 kva Model 80 80 kva 2x2 4x2 4x4 2x2 4x2 4x4 2x2 4x2 4x4 kva/kw @.8 PF 50/40 50/40 50/40 65/52 65/52 65/52 80/64 80/64 80/64 Input Voltage 208 480 480 208 480 480 208 480 480 Output Voltage 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz Nominal Input Current 157 68 68 208 90 90 258 112 112 Maximum Input Current 192 83 83 254 110 110 311 135 135 Nominal Output Current 139 139 60 180 180 78 222 222 96 System Efficiency 100% 86 88 88 86 88 88 86 88 88 Full Load Heat Refection (BTU/hr) 15200 14300 14300 19400 18600 18600 23000 22100 22100 Height - in (cm) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) 63 (160) Width - in (cm) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) 35.4 (90) Depth - in (cm) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) 28.7 (73) Net Weight - lbs (kg) 2050 (930) 1800 (816) 1800 (816) 2050 (930) 1800 (816) 1800 (816) 2050 (930) 1800 (816) 1800 (816) Ship Weight - lbs (kg) 2250 (1021) 2000 (909) 2000 (909) 2250 (1021) 2000 (909) 2000 (909) 2250 (1021) 2000 (909) 2000 (909) EDP70PLUS MODEL 80 RUNTIMES* BATTERY BATTERY BATTERY 50 kva 65 kva 80 kva NET WEIGHT SHIP WEIGHT PACK WIDTH lbs (kg) lbs (kg) Inches (cm) 1,100 (499). 1300 (591) 17.8 (45) 1,300 (590) 1500 (682) 17.8 (45). 1,800 (816) 2000 (909) 33.5 (85) 3,000 (1361) 3200 (1454) 51.3 (130) 2,950 (1338) 3150 (1432) 33 (84) + 9 min. 7 min. 5 min. 1,330 (603) 1530 (695) 17.8 (45) 17 min. 11 min. 7 min. 1,860 (844) 2060 (936) 33.5 (85) + 28 min. 19 min. 14 min. 3,090 (1402) 3290 (1495) 51.3 (130) + 28 min. 19 min. 14 min. 2,950 (1338) 3150 (1432) 33 (84) + 33 min. 23 min. 17 min. 3,400 (1545) 3600 (1636) 33 (84) + 40 min. 28 min. 21 min. 3,900 (1769) 4100 (1864) 40 (101) 64 min. 50 min. 38 min. 5,900 (2676) 6100 (2773) 66 (168) 81 min. 58 min. 44 min. 6800 (3084) 7000 (3182) 66 (168) ell), 25C (77 F), and 0.8 power factor at end of discharge, unless otherwise noted. Actual runtimes may vary. Runtimes over 60 minutes are based on 1.75 final volts/cell.

EDP70L 80-250 kva: Specifications Standard features Internal Maintenance Bypass Dual Input K-30 Rated Output Isolation Transformer On-Site Capacity Upgradeability Redundant Cooling Fans for Increased Reliability Pulse Width Modulated Inverter Temperature Compensated Battery Charger Secure Battery Test Generator Friendly 0.8 Input Power Factor RS232C and AS/400 Communication Ports Multilingual LCD Display On-Site Warranty EPO Switch EDP70L EDP70L MODEL 100-80 kva EDP70L MODEL 100-100kVA 2-2 4-2 4-4 2-2 4-2 4-4 kva/kw at 0.8 PF Lag 80/64 80/64 80/64 100/80 100/80 100/80 Field Upgradeable to kva/kw at 0.8 PF 100/80 100/80 100/80 Input Voltage (VAC)* 208Y/120 480Y/277 480Y/277 208Y/120 480Y/277 480Y/277 Output Voltage (VAC)* 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 Frequency (Hz) 60 60 60 60 60 60 Nominal Input Current (amps) 237 102 101 296 128 127 Maximum Input Current (amps) 296 129 127 370 164 162 Nominal Output Current (amps) 222 222 96 276 276 120 10 Min. Overload Current (amps) 276 276 120 347 347 150 System Efficiency at 100% Load (%) 90 91 92.5 90.5 91.5 92.5 at 75% Load (%) 90 91 92 90.5 91.5 92.5 at 50% Load (%) 89.5 90 91 89.5 90.5 91.5 Full Load Heat Rejection (BTUs/Hr.) 24,200 21,600 17,700 28,700 25,400 22,100 Height - in (cm) 70 (178) 70 (178) 70 (178) 70 (178) 70 (178) 70 (178) Width - in (cm) 56 (142) 32 (81) 32 (81) 56 (142) 32 (81) 32 (81) Depth - in (cm) 33 (84) 33 (84) 33 (84) 33 (84) 33 (84) 33 (84) Net Weight - lbs (kg) 2600 (1179) 2100 (952) 1650 (748) 2600 (1179) 2100 (952) 1650 (748) Ship Weight - lbs (kg) 2800 (1273) 2300 (1045) 1850 (841) 2800 (1273) 2300 (1045) 1850 (841) Operating Temperature +18 F to +104 F (-8 C to +40 C) +18 F to +104 F (-8 C to +40 C) Relative Humidity (noncondensing) 0 to 95% 0 to 95% Altitude without derating -ft (m) 3300 (1000) 3300 (1000) * 600 VAC input and output available. Other frequencies, voltages and wiring configurations available. BATTERY CABINET RUNTIMES* RUNTIMES* EDP70L 80 kva 100 kva 200 kva 225 kva NOTE: Battery life is optimized at 77 C (25 C). For every 15 F (8 C) above optimum temperature battery life is reduced by 50%. All runtimes are approximate and based on 1.67 final volts per cell (final volts/cell), 120C 1 x C 14 min. 10 min. 121C 1 x C 17 min. 12 min. 122C 1 x D 21 min. 15 min. 3 min. 2.5 min. 132C 1 x CR4 6 min. 6 min. 123C 2 x C 38 min. 27 min. 10 min. 8 min. 115C 2 x C 44 min. 33 min. 12 min. 10 min. 125C 2 x D 54 min. 40 min. 15 min. 13 min. 126C 3 x C 59 min. 48 min. 19 min. 16 min. 133C 2 x CR4 25 min. 20 min. 127C 3 x C 75 min. 56 min. 22 min. 19 min. 128C 3 x D 92 min. 69 min. 28 min. 24 min. + Not line-up and match cabinets. * Additional runtimes available, consult factory. NOTE: Nominal DC voltage is 480 VDC (240 cells/cabinet) NOTE: Runtimes are based on 480 V input and output.

Options LIFE2000 24-Hour Monitoring Service External Maintenance Bypass Extended Runtime and Matching Battery Cabinets MopUPS Network Shutdown Software ManageUPSNET SNMP/WEB Adapter Remote EPO Switch Deal RS232 via Multicomm Remote Alarm Unit Spare Parts Kits Extended Warranties Preventive Maintenance Inspection Packages UPS Monitoring Software 7% Input Harmonic Filter EDP70L MODEL 250-200 kva EDP70L MODEL 250-225 kva EDP70L MODEL 250-250 kva 2-2 4-2 4-4 2-2 4-2 4-4 2-2 4-2 4-4 200/160 200/160 200/160 225/180 225/180 225/180 250/200 250/200 250/200 225/180 or 250/200 250/200 208Y/120 480Y/277 480Y/277 208Y/120 480Y/277 480Y/277 208Y/120 480Y/277 480Y/277 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 208Y/120 208Y/120 480Y/277 60 60 60 60 60 60 60 60 60 589 254 252 662 285 284 736 317 315 736 329 326 828 372 367 920 411 408 555 555 241 625 625 271 694 694 301 694 694 301 780 780 338 867 867 376 91 92 93 91 92 93 91.5 92.5 93.5 90 91 92 90.5 91.5 92.5 91 92 93 89.5 90.5 91.5 89.5 90.5 92 90 91 92 54,000 47,500 41,000 60,700 53,400 46,200 63,400 55,300 47,500 70 (178) 70 (178) 70 (178) 70 (178) 70 (178) 70 (178) 70 (178) 70 (178) 70 (178) 104 (264) 80 (203) 56 (142) 104 (264) 80 (203) 56 (142) 104 (264) 80 (203) 56 (142) 33 (84) 33 (84) 33 (84) 33 (84) 33 (84) 33 (84) 33 (84) 33 (84) 33 (84) 4500 (2041) 3700 (1678) 2,900 (1315) 4500 (2041) 3700 (1678) 2900 (1315) 4500 (2041) 3700 (1678) 2900 (1315) 4700 (2136) 3900 (1773) 3100 (1409) 4700 (2136) 3900 (1773) 3100 (1409) 4700 (2136) 3900 (1773) 3100 (1409) +18 F to +104 F ( -8 C to +40 C) +18 F to +104 F (-8 C to +40 C) +18 F to +104 F (-8 C to +40 C) 0 to 95% 0 to 95% 0 to 95% 3300 (1000) 3300 (1000) 3300 (1000) BATTERY BATTERY BATTERY BATTERY 250 kva NET WEIGHT SHIP WEIGHT PACK WIDTH lbs (kg) lbs (kg) Inches (cm) 2,950 (1338) 3150 (1432) 33 (84) 3,360 (1527) 3560 (1618) 33 (84) 3,900 (1769) 4100 (1864) 40 (102) 5 min. 4,600 (2094) 4800 (2182) 40 (102) + 6 min. 5,900 (2676) 6100 (2773) 66 (168) 8 min. 6,800 (3091) 7000 (3182) 66 (168) 11 min. 7,750 (3515) 7950 (3614) 80 (203) 14 min. 8,850 (4014) 9050 (4114) 99 (251) 17 min. 9,200 (4182) 9400 (4273) 80 (203)+ 16 min. 11,050 (5023) 11250 (5114) 99 (251) 20 min. 11,600 (5262) 11700 (5318) 120 (305) 77 F (25 C), and 0.8 power factor at end of discharge. Actual runtimes may vary. Runtimes over 60 minutes are based on 1.75 final volts/cell.

R A H I G H E R L E V E L O F C O N F I D E N C E EDP90 225-3000* kva: Specifications Standard features Input Harmonic distortion <10% Parallel Capable for Redundancy or Capacity (6 module) On-Site Capacity Upgradeability Internal Maintenance Bypass K-20 Rated Output Isolation Transformer Redundant Cooling Fans for Increased Reliability Pulse Width Modulated Inverter 12 Pulse Rectifier Temperature Compensated Battery Charger Secure Battery Test Generator Friendly Top/Bottom Cable Entry RS232C and AS/400 Communication Ports Multilingual LCD Display On-Site Warranty Dual RS232 EPO Switch Options Power distribution modules External Maintenance Bypass Extended Runtime and Matching Battery Cabinets MopUPS Network Shutdown Software ManageUPSNET SNMP/WEB Adapter Remote Alarm Unit Spare Parts Kits and Extended Warranties LIFE2000 24-Hour Monitoring and Preventative Maintenance Service Remote EPO Switch EDP90/300 EDP90/400 EDP90/500 kva/kw at 0.8 PF Lag 225/180 250/200 300/240 300/240 350/280 400/320 400/320 450/360 500/400 Field Upgradeable to kva at 0.8 PF 250 or 300 300 350 or 400 400 450 or 500 500 Input Voltage (VAC) 1 480 480 480 Bypass Voltage (VAC) 1, 2 480Y/277 480Y/277 480Y/277 Output Voltage (VAC) 1, 2 480Y/277 480Y/277 480Y/277 Frequency (Hz) 60 60 60 System Efficiency at 100% Load (%) 92 92 92 92 92 92 92 92 92 Nominal Input Current (amps, at 0.82 PF) 287 319 383 383 446 510 510 574 638 Maximum Input Current (amps) 359 399 478 478 558 638 638 717 797 Nominal Output & Bypass Current (amps) 271 301 361 361 421 481 481 541 601 10 Min. Overload Current (amps) 339 376 451 451 526 601 601 676 751 Full Load Heat Rejection (BTUs/hr.) 53,405 59,339 71,207 71,207 83,075 94,943 94,943 106,810 118,678 Height - inches (cm) 70 (178) 70 (178) 70 (178) Width - inches (cm) 96 (244) 96 (244) 127 (315) Depth - inches (cm) 33 (84) 33 (84) 33 (84 Net Weight - lbs. (kg) 4,500 (2041) 5,410 (2454) 6,685 (3032) Ship Weight - lbs. (kg) 4,700 (2136) 5,610 (2550) 6,885 (3129) Maximum Acoustical Noise Level at 3 (1 m) (500 kva) 75 dba 75 dba 75 dba Operating Temperature +18 F to +104 F (-8 C to +40 C) +18 F to +104 F (-8 C to +40 C) +18 F to +104 F (-8 C to +40 C) Relative Humidity(noncondensing) 0 to 95% 0 to 95% 0 to 95% Operational Altitude without derating 3,300 (1,000) 3,300 (1,000 ) 3,300 (1,000) 1 Other frequencies, voltages and wiring configurations available. Consult factory for specifics. 2 System capable of 3-wire in/out operation (no neutral). * Models up to 500 kva are shown. Up to 3000 kva are available by paralleling up to 6 modules. BATTERYCABINET BATTERY BATTERY BATTERY PACK TYPE 225 kva 250 kva 300 kva 350 kva 400 kva 450 kva 500kVA NET WT SHIP WT PACK WIDTH RUNTIMES IN MINUTES** lbs (kg) lbs In (cm) 123C 2 x C 8 min. 6 min. 5,900 (2676) 6100 (2773) 66 (168) 115C 2 x C 10 min. 8 min. 5 min. 6,800 (3084) 7000 (3182) 66 (168) 125C 2 x D 13 min. 11 min. 7 min. 5 min. 7,750 (3515) 7950 (3614) 80 (203) 126C 3 x C 16 min. 14 min. 10 min. 7 min. 5 min. 8,850 (4014) 9050 (4114) 99 (251) 133C 2 x CR4 21 min. 17 min. 12 min. 9 min. 6 min. 9,200 (4182) 9400 (4273) 80 (203) + 127C 3 x C 19 min. 16 min. 12 min. 9 min. 7 min. 5 min. 11,050 (5012) 11250 (5114) 99 (251) 128C 3 x D 24 min. 20 min. 16 min. 12 min. 10 min. 7 min. 6 min. 11,600 (5273) 11700 (5318) 120 (305) 134C 4 x C 24 min. 21 min. 16 min. 13 min. 10 min. 8 min. 6 min. 11,800 (5352) 12000 (5454) 132 (335) 135C 4 x C 28 min. 24 min. 19 min. 15 min. 12 min. 10 min. 8 min. 13,600 (6169) 13800 (6273) 132 (335) 136C 3 x CR4 36 min. 31 min. 25 min. 20 min. 16 min. 12 min. 10 min. 13,800 (6273) 14000 (6364) 120 (305) + 137C 4 x D 35 min. 30 min. 24 min. 19 min. 16 min. 13 min. 11 min. 15,500 (7031) 15700 (7136) 160 (406) 138C 4 x CR4 53 min. 46 min. 36 min. 29 min. 25 min. 20 min. 17 min. 18,400 (8364) 18600 (8454) 160 (406) + ** Additional runtimes available, consult factory. Wet cell information and pricing available upon request. NOTE: All runtimes are approximate and based on 1.67 final volts per cell (EOD). NOTE: Nominal DC voltage is 480 VDC (240 cells/cabinet) NOTE: Battery life is optimized at 77 F (25 C). For every 15 F (8 C) above optimum temperature, battery life is reduced by 50%. NOTE: Runtimes are based on 480 V input and output. A Chloride Power Protection Company ONEAC and MopUPS are registered trademarks and ManageUPS is a trademark of ONEAC Corporation. LIFE2000 is a trademark of Chloride. All other trademarks are the property of their respective companies. ONEAC is a UL/BSI registered corporation Certification No. A2900 (800) 327 8801 OPT. 2 in USA AND CANADA +44 (0) 2380 610311 in UK AND EUROPE 27944 N. Bradley Road, Libertyville, IL 60048 Phone 847 816-6000 FAX 847 680-5124 George Curl Way, Southampton, Hampshire SO18 2RY, UK FAX +44 0 2380 612039 www.oneac.com All specifications subject to change without notice. 2004 ONEAC Corporation Printed in U.S.A. Part No. 917-162 Rev. B