NEW. Display Color Analyzer CA-410. Broad measurement support for today's ever-evolving displays CA-310 successor with major improvements

Similar documents
Display Color Analyzer

specification hyperion colorimeter

specification hyperion colorimeter

DISPLAY COLOR ANALYZER MODEL 7123 MODEL Display Color Analyzer. Key Features:

specification MSE series MSE and MSE+ colorimeter

specification display applications cronus spectrometer & colorimeter

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

SPECTRORADIOMETER CS-2000/CS-2000A

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

Setup Guide. SpectraCal C6 HDR2000 Colorimeter. Rev. 1.2

OPTICAL POWER METER WITH SMART DETECTOR HEAD

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Advantech Proudly Presents Professional Monitor Series

VPL-HW45ES Home Theater Projector

NEC MultiSync PA Series with SpectraView II

PicoScope 4000 Automotive PC Oscilloscopes

LD-V4300D DUAL STANDARD PLAYER. Industrial LaserDisc TM Player

FLAT DISPLAY TECHNOLOGY

POWER TO YOUR NEXT STEP

PicoScope 3000 Series Automotive User guide

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

General Specifications

LMD-1541W. 15-inch high grade LCD monitor. Overview

QuickSpecs. HP V19b 18.5-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK. 1. Power connector 3. Security lock slot 2.

Overview. Dimensions and weights 1. Specifications SMART Board 7086 interactive display Model SBID-7086

DATA/SPEC SHEET 16-CHANNEL HYBRID DIGITAL VIDEO RECORDER. Built for Reliability, Usability, and Low Cost of Ownership.

XC-77 (EIA), XC-77CE (CCIR)

LCD MODULE SPECIFICATION

PicoScope 2000 Series PC Oscilloscopes

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

QuickSpecs. HP V inch Monitor. Overview

QuickSpecs. HP VH27 27-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. Exit

ABS ST700 Compact Type Series

VPL-DX131. 2,600 lumens XGA Desktop projector. Overview

Palette Master Color Management Software

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

IFM65UG OPS-COMPLIANT 16/7 400 NITS ULTRA HD INTERACTIVE FLAT PANEL DISPLAY

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

Ethernet to VGA over IP Converter

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

QuickSpecs. HP N220h 21.5-inch Monitor. Overview. 1. Menu/OK 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. Exit/Back

VPL-DX220. 2,700 lumens XGA desktop projector. Overview

R3267/3273 Spectrum Analyzers

PT-LB382 S P E C F I L E. LCD Projectors. As of July Specifications and appearance are subject to change without notice. 1/9.

3CCD Color Video Camera BRC-300 BRC-300P. USA Security Systems

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

LCD Display Wall Narrow Bezel Series

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

PRODUCT NO.: PT-LB10NT PRODUCT NAME: Micro-Portable Wireless LCD Projector

HITACHI. Instruction Manual VL-21A

NEC MultiSync PA Series Wide Gamut LED-backlit color accurate desktop displays

1215L 12 LCD Desktop Touchmonitor

VPL-DX102. 2,300 lumens XGA Desktop projector. Overview

Technical Developments for Widescreen LCDs, and Products Employed These Technologies

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

Datasheet IVU.box.touch

OLED. Groundbreaking technology in surgical imaging. PVM-2551MD Medical OLED Monitor

PRODUCT NO.: PT-L735NT PRODUCT NAME: Ultra Portable Wireless LCD Projector

QuickSpecs. HP V214a 20.7-inch Monitor. HP V214a 20.7-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK

PT-TX400 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

PT-LB385 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

Dell Wyse 5030 PCoIP Zero Client

Specifications SMART Board 6075 interactive flat panel with iq Model SPNL-6275

Good Display Specifications

SMART Board Interactive Whiteboard System

Product Number : LW373 Product Name : As of October Specifications and appearance are subject to change without notice.

Product Guide. WaveAnalyzer High-Resolution Optical Spectral Analysis

ADN-8126 JJTRON Display System

PicoScope 4000 Series PC Oscilloscopes

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

BVM-X300 4K OLED Master Monitor

BVM-E inch TRIMASTER EL OLED critical reference monitor with wide viewing angle supports 4K production. Overview

Winmate Communication INC.

SMART Board interactive whiteboard system Model 685i5

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

NEC MultiSync PA322UHD-2. Wide Gamut 4K UHD resolution, LED-backlit color accurate desktop display

Detect Color and Shape for various inspection

PRODUCT NO.: PT-L735 PRODUCT NAME: Ultra Portable LCD Projector

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Video VBOX Waterproof

D-ILA HD Projection Systems DLA-HD10K DLA-HD10KS. Native 1080p High-Definition. Images with Superb Colour Reproduction

VGA AUDIO SWITCHER S MANUAL

HOBO H Energy Logger

Showcasing Brilliant Photos with Superb High- Definition Clarity

NEC MultiSync PA243W. Wide Gamut color critical accurate desktop display

DS2460Q QAM Analysis Meter

Multi Application Test System

55-inch Class FULL HD LCD Display TH-55SF1HW

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Synthesized Block Up- and Downconverter Indoor / Outdoor

Product Number : TW350 Product Name : As of October Specifications and appearance are subject to change without notice.

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

Simply the best. The information in this document is subject to change without notice

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

USB Smart Power Sensor

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

EXT-UHD600-1SC Version A1

Transcription:

NEW Display Color Analyzer CA410 1 Broad measurement support for today's everevolving displays CA310 successor with major improvements

4 improvements for display 1 Accuracy guaranteed from ultralow to high brightness With more and more displays becoming HDR (High Dynamic Range), the pressure is mounting for color analyzers to improve their measurement performance at both high and low brightnesses. By using new sensors and circuitry, the CA410 realizes an accuracyguaranteed brightness range 25x wider than its predecessor (compared to the CA310 when using Normal Probe CAP427). This gives users the means to accurately measure and adjust the chromaticity and gamma characteristics of HDR displays across a wide brightness range from ultralow to high. Display brightness measurement example Earlier model display: 0.01 to 500 cd/m 2 HDR display: 0.001 to more than 1,000 cd/m 2 CA310 (Using CAP32 probe) Accuracy guaranteed range for luminance: 0.005 to 1,000 cd/m 2 CA410 (Using CAP427 probe) Accuracy guaranteed range for luminance: 0.001 to 5,000 cd/m 2 CA410 CA310 0.001 0.01 0.1 100 1000 10000 cd/m 2 *CA310: Using CAP32 probeca410: Using CAP427 probe 2 Improved chromaticity measurement accuracy The greater intensity and wider color gamut of newer displays require color analyzers that can measure chromaticity to a higher degree of precision. Thanks to the enhanced accuracy of the XYZ filters, the CA410 pushes its spectral sensitivity even closer to the colormatching functions of CIE 1931 (compared to the CA310). Moreover, the accuracy of chromaticity measurements has been further improved by calibrating the analyzer with reference that replicates the optical spectrum of an LED light source for displays. As such, users can more accurately measure and adjust the chromaticity and white balance of displays that have a wide color gamut. CA410 spectral sensitivity vs. CIE 1931 colormatching functions Guaranteed accuracy (xy; when measuring standard light source) CA310 White: ±0.003 RGB: ±0.004 CA410 White: ±0.002 RGB: ±0.003 Relative spectral sensitivity 1 0.5 CA410 spectral sensitivity x'(λ) CA410 spectral sensitivity y'(λ) CA410 spectral sensitivity z'(λ) CIE colormatching functionx'(λ) CIE colormatching functiony'(λ) CIE colormatching functionz'(λ) 0 380 480 580 680 780 Wavelength (nm) High Sensitivity Probe CAVP410's spectral sensitivities are shown above as typical. CA310: Based on Konica Minolta's reference LCD CA410: Based on Konica Minolta's reference light source

measurement support 3 Optimized specifications for integration as a sensor Since the launch of the first model, Konica Minolta's CA series display color analyzers have been incorporated by many customers into automatic measurement systems as color sensors due to their high accuracy. The CA410 is optimized for even better integration as a sensor with a motorized zeropoint calibration shutter for automatic unmanned support and direct connection between probes and a computer for a more compact installation. At the same time, it maintains compatibility with its predecessor model by including the same basic commands in the CASDK2 as were available in the software development kit (SDK) of the previous model and locating the threaded probe installation holes in the same positions as on the predecessor model (excluding Mini Probe CAMP410). Example system configuration PG 4 Wider measurement application support Continuing to work with longstanding CAseries customers and respond to their needs, we developed the CA410 to deliver higher reliability for a wider range of measurement targets and applications; when measuring gamma, for example, the CA410 provides reduced betweenrange errors, shorter range switching time, and support for lowfrequencydrive displays. Measurement time simulation for gamma measurement [ms] 6000 4000 2000 0 CA 310 CA 410 Time performing measurement Time switching ranges * Probe used: CA310: CAP32; CA410: CAP427 Measurement sync mode: NTSC Measurement speed mode: CA310: AUTO; CA410: LTD. AUTO For 64step gamma measurement at 0.01 500 cd/m 2 Not including wait time or display drive time.

Lineup of probes for diverse measurement needs 3 CAP410 4 CAP427 1 CAVP410 2 CAVP427 5 CAMP410 High Sensitivity Probes CAVP410 (Measurement area: ø10 mm) CAVP427 (Measurement area: ø27 mm) This model is suited for measuring highend OLED displays across a wide brightness range from ultralow to high at high speed. Use for: Measuring, inspecting and adjusting chromaticity and gamma characteristics of OLED displays for TVs and smartphones across a wide brightness range from ultralow to high Normal Probes CAP410 (Measurement area: ø10 mm) CAP427 (Measurement area: ø27 mm) This model is suited for measuring a wide range of displays, and is also compatible with the CA310. * Available also in highbrightness models capable of measurements up to 30,000 cd/m 2 (CAP410H: ø10 mm measurement area; CAP427H: ø27 mm measurement area) Mini Probe CAMP410 (Measurement area: ø10 mm) This model is designed to render the same level of performance as the CA310 but in an even smaller package. Use for: Applications that require smallsized probes or portability, i.e., color sensor for automatic measurement systems used in small display production processes, calibration of professional monitors and other applications that require spacesaving design * Available also in a highbrightness model capable of measurements up to 30,000 cd/m 2 (CAMP410H: ø10 mm measurement area) Probe dimensions (Units : mm) 1 ø34 28 with the hood 32 30 2 ø38.5 28 with the hood 32 35 3 ø26.5 ø20.8 28 with the hood 32 ø24 ø23 136 126 116 ISO 5mm Tripod socket 8.5 47 47 225 1.5 108 98 88 ISO 5mm Tripod socket 8.5 47 47 189 1.5 136 126 116 ISO 5mm ISO 5mm 107.6 Tripod socket; Tripod socket; 11 42 42 172 1.5 4 ø37 5 29 28 ISO 5mm; Tripod socket; ISO 5mm; with the hood 108 98 88 73.7 Tripod socket; 11 42 ø33 138.2 1.5 ø3 Depth 3mm ø27.5 with the hood 9 55.5 ISO 5mm; Tripod socket; ISO 5mm; 45.5 35.5 27.5 63.5 4 32 29 Depth 3mm 3 11 42 3.5 ISO 3mm; Depth 5.5mm ø24.5 ø15.1 1.5 42 77 ISO 3mm;Depth 5mm

Easytooperate CADP40 data processor Data processor dimensions (Units : mm) 253 75 34 75 143 58 87.5 CADP40 M4 threaded installation holes on back side (x 4) Data processor Because of the fast pace at which products and technologies evolve, speed is of the essence when it comes to R & D activities in the display industry. That is why the CADP40 data processor takes the "easytooperate" feature of the CA310 to new heights. With automatic zeropoint calibration that allows measurement to start immediately after the power is turned ON, an easytoview 7inch color display multilingual support and a lithium ion battery (sold separately) that makes the unit portable, the CADP40 obtains measurement data quickly and reliably, making it convenient for onthespot for R & D applications. Moreover, the CADP40 can connect to a maximum of 10 probes, which gives users the support they need for multipoint measurements. Carrying Case CAA01 (Sold separately) Software for Color Analyzer included PC Software for Color Analyzer CAS40 and Software Development Kit CASDK2 give users even wider versatility in terms of applications and set up, by making it possible for probes to be directly connected to the computer measurements. Both CAS40 and CASDK2 come standard with all CA410 probes and support Windows 7/10 as well as macos. Chromaticity measurement JEITA flicker measurement

Main Specifications of CA410 Probes * Regarding specifications of CAP410H and CAP427H Probes for high luminance, please contact the nearest Konica Minolta s sales representative. High Sensitivity Probe Normal Probe CAVP410 CAVP427 CAP410 Measurement area ø10 mm ø27 mm ø10 mm Acceptance angle ±8.5 ±2.5 ±5 Accuracy guaranteed measurement distance 30±5 mm 30±10 mm 30±5 mm Display range Luminance Chromaticity Flicker (Contrast) Flicker (JEITA) Luminance 0.0001 to 3,000 cd/m 2 0.0001 to 3,000 cd/m 2 0.0001 to 5,000 cd/m 2 Chromaticity Displayed in 4 digits Displayed in 4 digits Displayed in 4 digits Accuracy guaranteed range 0.001 to 3,000 cd/m 2 0.001 to 3,000 cd/m 2 0.01 to 5,000 cd/m 2 Accuracy (for white) *1, *3 Repeatability (2σ) *1 AUTO > 0.001 cd/m 2 ±9% ±9% > 0.01 cd/m 2 ±2.5% ±2% ±2.5% > 0.1 cd/m 2 ±2% ±1.5% ±2% > 1 cd/m 2 ±2% ±1.5% ±2% > 10 cd/m 2 ±1.5% ±1.5% ±1.5% > 100 cd/m 2 ±1.5% ±1.5% ±1.5% > 0.001 cd/m 2 7% 10% > 0.01 cd/m 2 1% 1% 2% > 0.1 cd/m 2 0.25% 0.25% 0.60% > 1 cd/m 2 0.10% 0.10% 0.20% > 10 cd/m 2 0.10% 0.10% 0.10% > 100 cd/m 2 0.10% 0.10% 0.10% Accuracy guaranteed luminance range 0.01 to 3,000 cd/m 2 0.01 to 3,000 cd/m 2 0.01 to 5,000 cd/m 2 Accuracy (for white) Repeatability (2σ) *1 *1, *3 > 0.01 cd/m 2 ±0.003 ±0.003 ±0.006 > 0.1 cd/m 2 ±0.002 ±0.002 ±0.002 > 1 cd/m 2 ±0.002 ±0.002 ±0.002 > 10 cd/m 2 ±0.002 ±0.002 ±0.002 > 100 cd/m 2 ±0.002 ±0.002 ±0.002 At 100 cd/m 2 (for 100 cd/m 2 ±0.003 ±0.003 ±0.003 monochrome) *2 AUTO > 0.01 cd/m 2 0.0020 0.0030 0.0070 > 0.1 cd/m 2 0.0008 0.0008 0.0020 > 1 cd/m 2 0.0003 0.0003 0.0008 > 10 cd/m 2 0.0002 0.0002 0.0005 > 100 cd/m 2 0.0002 0.0002 0.0003 Measurement luminance range 15 cd/m 2 or higher Accuracy 30 Hz, AC/DC 10% sine wave ±0.4% 60 Hz, AC/DC 10% sine wave ±0.7% Repeatability (2σ) 2065 Hz, AC/DC 10% sine wave 0.3% Measurement luminance range 15 cd/m 2 or higher Accuracy 30 Hz, AC/DC 4% sine wave ±0.35dB 30 Hz, AC/DC 1.2% sine wave ±0.35dB Repeatability (2σ) 30 Hz, AC/DC 4% sine wave 0.1dB 30 Hz, AC/DC 1.2% sine wave 0.3dB > From minimum luminance cd/m Accuracy 1 time/sec 1 time/sec 1 time/sec L guaranteed V xy AUTO > 0.15 cd/m 2 5 times/sec 5 times/sec 5 times/sec > 2 cd/m 2 20 times/sec 20 times/sec 20 times/sec measurement Flicker (Contrast) 20 times/sec speed 0.5 times/sec (at 1 Hz pitch) *4 Flicker (JEITA) 2.5 times/sec (at 10 Hz pitch) Measurement synchronization mode Measurement speed mode Supported range to be measured (frequency) 0.5 to 130 Hz (flicker) User calibration memory channel 99 channels 99 channels 99 channels Interface Communication USB 2.0, RS232C USB 2.0, RS232C USB 2.0, RS232C Trigger In and Out [5 V] In and Out [5 V] In and Out [5 V] Size (mm) 47 x 47 x 226.5 47 x 47 x 190.5 42 x 42 x 173.5 Weight 570 g (including mount) 510 g (including mount) 280 g (including mount) Power supply DC 5 V (input from USB bus power line DC 5 V (input from USB bus power line DC 5 V (input from USB bus power line or RS communication connector) or RS communication connector) or RS communication connector) Operation temperature/humidity range *5 10 to 35 C, relative humidity 85% or less with no condensation Storage temperature/humidity range 0 to 45 C, relative humidity 85% or less (at 35 C)with no condensation Accessories Standard PC Software for Color Analyzer Ver.1.0 CAS40, SDK for Color Analyzer CASDK2, USB Cable for ProbePC (2 m) IFA28, Hood Optional Conversion Cable IFA29, BNC Conversion Cable IFA35 Measured with Konica Minolta's specified PC and probe connected directly, using the supplied measurement software. *1: Measured under Konica Minolta s standard light source (6,500K). *2: Luminance for monochrome is measured when reading of luminance for white is 100 cd/m 2. *3: Temperature 23 C/±2 C, relative humidity 40%±10% *4: In NTSC synchronization mode using USB with one probe *5: Reading variation within range (compared to reference reading at 23 C, 40% RH): Luminance: ±2% for white; Chromaticity (at 100 cd/m 2 ): ±0.002 for white, ±0.003 for monochrome

Main Specifications of Data Processor CADP40 CAP427 Mini Probe CAMP410 ø27 mm ø10 mm ±2.5 ±5 30±10 mm 10±5 mm 0.0001 to 5,000 cd/m 2 0.0001 to 5,000 cd/m 2 Displayed in 4 digits Displayed in 4 digits 0.001 to 5,000 cd/m 2 0.01 to 5,000 cd/m 2 ±9% ±2% ±2.5% ±1.5% ±2% ±1.5% ±2% ±1.5% ±1.5% ±1.5% ±1.5% 10% 1% 2.40% 0.40% 0.70% 0.10% 0.25% 0.10% 0.12% 0.10% 0.10% 0.01 to 5,000 cd/m 2 0.01 to 5,000 cd/m 2 ±0.003 ±0.006 ±0.002 ±0.002 ±0.002 ±0.002 ±0.002 ±0.002 ±0.002 ±0.002 ±0.003 ±0.003 0.0035 0.0085 0.0015 0.0025 0.0004 0.0010 0.0003 0.0006 0.0002 0.0004 5 cd/m 2 or higher 15 cd/m 2 or higher ±0.4% ±0.4% ±0.7% ±0.7% 0.3% 0.3% 5 cd/m 2 or higher 15 cd/m 2 or higher ±0.35dB ±0.35dB ±0.35dB ±0.35dB 0.1dB 0.1dB 0.3dB 0.3dB 1 time/sec 1 time/sec 5 times/sec 5 times/sec 20 times/sec 20 times/sec 20 times/sec 20 times/sec 0.5 times/sec (at 1 Hz pitch) 2.5 times/sec (at 10 Hz pitch) 0.5 times/sec (at 1 Hz pitch) 2.5 times/sec (at 10 Hz pitch) 0.5 to 130 Hz (flicker) 0.5 to 130 Hz (flicker) 99 channels 99 channels USB 2.0, RS232C USB 2.0, RS232C In and Out [5 V] In and Out [5 V] 42 x 42 x 139.7 42 x 42 x 77 270 g (including mount) 200 g (including mount) DC 5 V (input from USB bus power line or RS communication connector) DC 5 V (input from USB bus power line or RS communication connector) for Probe, Lens Cap for Probe Display range Display Display items Luminance 0.0001 to 30,000 cd/m 2 Chromaticity Displayed in 4 digits Flicker (Contrast) 0.00 to 999.99 % (JEITA) To 2 decimal places 7inch color LCD WVGA L V x y ( L V x y) L V u' v' ( L V u' v') L V Tcp duv ( L V Tcp duv) X Y Z ( X Y Z) L V λd Pe ( L V λd Pe) Flicker (Contrast) Flicker (JEITA) 100 CH Available English, Simplified Chinese, Traditional Chinese, Korean, Japanese Measurement data storage channels Data logging function Display languages Interface For computer, etc. USB 2.0 RS232C Ethernet *[Optional] Bluetooth (module required) For probes MiniDIN 8pin cable (for RS communication) USB (for USB communication) Sync signal input BNC connector (with trigger input) Multi probe connection 10 probes (maximum) Operation temperature/ humidity range 10 to 35 C, relative humidity 85% or less with no condensation Storage temperature/ humidity range 0 to 45 C, relative humidity 85% or less (at 35 C)with no condensation Power AC Adapter *[Optional] LithiumIon Battery (removable) Battery life 3 hours (when one probe is connected) Size 253 (W) x 58 (H) x 143 (D) mm Weight 1.6 kg Accessories Standard AC Cable RS Cable for ProbeDP (2 m) IFA30 AC Adapter ACA312F Optional USB Cable for DPPC (2 m) IFA34 RS Cable for ProbeDP IFA31 (5 m), IFA32 (10 m) LithiumIon Battery CMA223 Bluetooth Module CMA219 Carrying Case CAA01 Main Specifications of PC Software CAS40 <System requirements> Windows 7 Professional 32bit Windows 7 Professional 64bit Windows 10 Pro 32bit Windows 10 Pro 64bit OS macos Sierra The hardware of the computer system to be used must meet or exceed the greater of the recommended system requirements for the compatible OS being used or the following specifications. CPU Intel Core i series or equivalent Memory 4 GB or more Needs free space of at least 100 MB, and at least 50 MB on system drive where OS is Hard disk drive installed Display Capable of at least 1,280 768 dots/ High color, 16bit USB port for installing from flash drive Others USB port (2.0 or higher) for connecting measuring instruments <Controllable instruments> CA410 Data Processor CADP40 CA410 Probes CAP427 / P427H / P410 / P410H / MP410 / MP410H / VP427 / VP410 <Languages> Display language English

System Diagram Data Processor standard accessory Probe standard accessory Optional accessory [Data Processor] CADP40 LithiumIon Battery CMA223 USB Cable for DPPC (2 m) IFA34 AC Adapter ACA312F Bluetooth Module CMA219 RS Cable for ProbeDP (2 m) IFA30 RS Cable for ProbeDP IFA31 (5 m) IFA32 (10 m) Carrying Case CAA01 PC (Commercially available) [Probe] Normal Probe CAP427 CAP410 High Sensitivity Probe CAVP427 CAVP410 (minidin) BNC Conversion Cable IFA35 (BNC) RS232C cable (Commercially available) PC Software for Color Analyzer CAS40 SDK for Color Analyzer CASDK2 (minidin) (Dsub 9pin) Mini Probe CAMP410 Conversion Cable IFA29 (BNC) (Power Cable) A lens hood and lens cap are included as standard with all probes. USB Cable for ProbePC (2 m) IFA28 Windows is a trademark or registered trademark of Microsoft Corporation in the USA and other countries. macos Sierra is a registered trademark of Apple Inc. in the USA and other countries. Intel Core is a trademark or registered trademark of Intel Corporation in the USA and other countries. Other company names and product names used herein are trademarks or registered trademarks of their respective companies. Bluetooth is a registered trademark of Bluetooth SIG, Inc. and is used under license agreement. Screens shown are for illustration purposes only. The specifications and appearance shown herein are subject to change without notice. SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. Certificate No : LRQ 0960094/A Registration Date : March 3, 1995 Certificate No : JQAE80027 Registration Date : March 12, 1997 2017 KONICA MINOLTA, INC. 9242488519 BHKPK Printed in Japan