SPP-100 Module for use with the FSSP Operator Manual

Similar documents
PCASP-X2 Module Manual

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

U SER S G UIDE. TS2002A Fiber Optic Test Kit

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition

PulseCounter Neutron & Gamma Spectrometry Software Manual

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 2nd Edition

DVI Rover 700 User Guide

ExtIO Plugin User Guide

The Measurement Tools and What They Do

PYROPTIX TM IMAGE PROCESSING SOFTWARE

Working with CSWin32 Software

Operating Instructions

User s Manual. Log Scale (/LG) GX10/GP10/GX20/GP20 IM 04L51B01-06EN. 1st Edition

Fog Monitor Model FM-100. Operator Manual

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

Getting started with Spike Recorder on PC/Mac/Linux

Pre-processing of revolution speed data in ArtemiS SUITE 1

MaxView Cinema Kit Quick Install Guide

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

Field Test 2. Installation and operation manual OPDAQ Installation and operation manual

OPERATING YOUR SYSTEM WITH MX-850

INSTRUCTION MANUAL DAFM2

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

ASSEMBLY AND CALIBRATION

STB Front Panel User s Guide

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

3GSDI to HDMI 1.3 Converter

PSP Master Comp. Stereo Mastering Compressor

User Guide & Reference Manual

EAN-Performance and Latency

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Modbus for SKF IMx and Analyst

Agilent N6467A BroadR-Reach Compliance Test Application. Methods of Implementation

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies

StickIt! VGA Manual. How to install and use your new StickIt! VGA module

Precision DeEsser Users Guide

User Manual OVP Raman

HawkEye 1500 Series Quick Start Guide V2.4.1, Nov 2008

Noise Detector ND-1 Operating Manual

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

ivw-ud322 / ivw-ud322f

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

TelePresence Cisco TelePresence Synch with Edge95MXP - Troubleshooting

Extra long-range RFID (proximity) card reader

homework solutions for: Homework #4: Signal-to-Noise Ratio Estimation submitted to: Dr. Joseph Picone ECE 8993 Fundamentals of Speech Recognition

Weschler AMT Software for the Enhanced Version Transformer Advantage

SQTR-2M ADS-B Squitter Generator

MX Compliance Test System System Administrator MXCTSH / MXCTSL. Revision B 1

Wireless Studio. User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference.

CytoFLEX Flow Cytometer Quick Start Guide

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA

RF Solution for LED Display Screen

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

ET BLU MIX RX-Condo-3

USER S MANUAL. FX2N-8AD Analog input block

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

RX40_V1_0 Measurement Report F.Faccio

AtlonA HDMI Media Center 6 inputs 1 output Switcher & Converter & 1080p Up-Scaler AT-LINE-EX. User Manual

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Remote Application Update for the RCM33xx

Agilent N5431A XAUI Electrical Validation Application

DVI to HD-SDI Scaler Pro

Application Note. PICOLO Alert, Sharing the Digitizing Power

ASKING FOR ASSISTANCE

READ THIS FIRST. Morphologi G3. Quick Start Guide. MAN0412 Issue1.1

FalconX1/X4/X8 Quick Start Guide

Configuring and Troubleshooting Set-Top Boxes

KHT 1000C HV-Probe Calibrator. Instruction Manual

Transmitter Interface Program

WHALETEQ PPG Heart Rate Simulator Test System (HRS200) User Manual

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

Chapter 23 Dimmer monitoring

Keysight PXA Signal Analyzer

USB-TG124A Tracking Generator User Manual

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

Netzer AqBiSS Electric Encoders

V9A01 Solution Specification V0.1

GuardPLC Certified Function Blocks -- Basic Suite

medlab One Channel ECG OEM Module EG 01000

DVI to HD-SDI Conversion Box

Operator's Manual. MS-250 Mixed Signal Oscilloscope Option

SC-HD-2A HDMI Scaler & Audio Embedder / Extractor

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

UC1000 Universal Controller

M1 OSCILLOSCOPE TOOLS

4X1 Gefen TV Switcher. GTV-HDMI User Manual

Appendix Lightolier Compose System

DMC550 Technical Reference

Viavi T-BERD 5800 CPRI Testing Guide with ALU BBU Emulation

PIECEWISE PRODUCTION MACHINES

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

LogiCORE IP Spartan-6 FPGA Triple-Rate SDI v1.0

NT-9600 Wireless Barcode Scanner. Introduction

NanoTrack Cell and Particle Tracking Primer

AtlonA 4x4 HDMI over CAT5 Matrix Switcher with IR Control AT-HD44M-SR. User Manual

SEM- EDS Instruction Manual

EDL8 Race Dash Manual Engine Management Systems

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

Transcription:

` Particle Analysis and Display System (PADS): SPP-100 Module for use with the FSSP Operator Manual DOC-0199 A; PADS 2.8.2 SPP-100 Module 2.8.2 2545 Central Avenue Boulder, CO 80301 USA C O P Y R I G H T 2 0 1 0 D R O P L E T M E A S U R E M E N T T E C H N O L O G I E S, I N C.

Copyright 2010 Droplet Measurement Technologies, Inc. 2545 CENTRAL AVENUE BOULDER, COLORADO, USA 80301-5727 TEL: +1 (303) 440-5576 FAX: +1 (303) 440-1965 WWW.DROPLETMEASUREMENT.COM All rights reserved. DMT licenses PADS software only upon the condition that you accept all of the terms contained in this license agreement. Each PADS license you purchase allows you to acquire data on one computer only. Data can be viewed in playback mode on an unlimited number of computers. This software is provided by DMT as is and any express or implied warranties, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose are disclaimed. Under no circumstances and under no legal theory, whether in tort, contract, or otherwise, shall DMT or its developers be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including damages for work stoppage; computer failure or malfunction; loss of goodwill; loss of use, data or profits; or for any and all other damages and losses). Some states do not allow the limitation or exclusion of implied warranties and you may be entitled to additional rights in those states. Trademark Information All Droplet Measurement Technologies, Inc. product names and the Droplet Measurement Technologies, Inc. logo are trademarks of Droplet Measurement Technologies, Inc. All other brands and product names are trademarks or registered trademarks of their respective owners. Form DOC-0199 Rev A II

C O N T E N T S 1.0 Introduction... 4 2.0 Configuration... 4 Configuring the SPP-100... 4 Configuring the SPP-100 Display... 8 3.0 The SPP-100 Window... 9 Channel Tabs... 10 Chart Displays... 11 Histogram Data Window... 11 Appendix A: SPP-100 Channels... 13 L i s t o f F i g u r e s Figure 1: SPP-100 Configuration Editor Window... 5 Figure 2: SPP-100 Display Editor Window... 9 Figure 3: SPP-100 Window... 10 Figure 4: SPP-100 Histogram Display with Scaling Buttons... 11 Form DOC-0199 Rev A I I I

1.0 Introduction The Particle Analysis and Display System (PADS) is a software package that interfaces with instruments produced by Droplet Measurement Technologies (DMT) and other leading instruments used in the atmospheric sciences. This manual describes the PADS module for the SPP-100. The module is typically used with the FSSP, which uses SPP-100 electronics. For an explanation of the basic PADS setup and instructions on how to acquire data using PADS, consult the PADS Operator Manual, DOC-0116. Definitions and calculations used in the SPP-100 module are also described in the PADS Operator Manual. 2.0 Configuration Using PADS, you can configure both the software for the instrument and the instrument s data display in PADS. The following two sections explain how to do this. Configuring the SPP-100 Your SPP-100 and data system should arrive preconfigured from DMT. In some cases, however, you may want to change the software configuration for the instrument. To do this, follow the steps below. Note: Droplet Measurement Technologies STRONGLY recommends that customers contact our office prior to changing any of the parameters in the instrument configuration. Improper changes can result in communication failure and/or changes in PADS computation algorithms, which can compromise data validity. 1. Click on the SPP-100 tab. 2. From the Configure menu, select Configure Instrument. You will see the following window. Form DOC-0199 Rev A 4

Figure 1: SPP-100 Configuration Editor Window 3. Now you can configure the instrument parameters to your desired specifications. You will find a list of the parameters you may want to reconfigure in the two sections below, Occasionally Reconfigured SPP-100 Parameters and Rarely Reconfigured SPP-100 Parameters. If at any time you would like to revert to the previously saved values for the SPP-100 parameters, press Cancel to exit the window without saving changes. 4. When you are done configuring the SPP-100 parameters, press Save at the top of the Config editor window. (If you would instead like to revert to the previously saved values, click Cancel.) Then press the green Reset Program button for the new configuration to take effect. Note that pressing the Reset Program button will clear any data currently being displayed. Form DOC-0199 Rev A 5

Occasionally Reconfigured SPP-100 Parameters Sample Time: This parameter shows the time interval you'd like between samples. You can have the probe sample at intervals of.1,.2,.5, 1, 2, 5, or 10 seconds (10, 5, 2, 1, 0.5 or 0.1 Hz). A value of one is recommended, as described in the warning below. Note that if you increase the sample time, you will still collect data for the same number of particles. This is because the probe collects data continuously and relays cumulative data at each sampling interval. For example, say you have the sample time set to.5 seconds. You might see four particles of size 25 µm during the first sample, and five particles of this size during the second sample. If you had set your sample time to one second instead of.5 seconds, you would instead get one sample that showed nine particles of size 25 µm. WARNING: One hertz sampling is currently recommended, as choosing other values will invalidate time-dependent PADS calculations like number concentration, volume concentration, and LWC on optical probes. (ED and MVD are not affected.) At Startup Enabled / Disabled: If you want the SPP-100 to acquire data when PADS begins sampling, make sure this parameter is in the Enabled mode. In some cases, such as if the FSSP is inoperative, you may want to use this control to disable the probe. Disabling the FSSP allows data to transmit from other instruments without interference. COM Port: This is the serial communications port that the SPP-100 uses to connect with the computer. This number should match the computer hardware configuration for the particular computer you are using. If you are not using multiple computers, this number should not be changed. TAS Source: These radio buttons allow users to control the source for true air speed. Measured TAS uses the global PADS true air speed indicated on the Setup Tab. This can be the TAS measured by one of the instruments or the Manual TAS selected on the Setup tab. Manual TAS uses the air speed entered in the field beneath the TAS Source radio buttons. (This field is only visible when Manual TAS is selected.) When manual TAS is selected, the airspeed (m/sec) will also be displayed on the main SPP-100 display. You will notice that there are other parameters listed on the SPP-100 Config Editor window. You should not need to change these, and changing them may compromise your data. If you are curious about these parameters or think you do need to modify them, see the section titled Rarely Reconfigured SPP-100 Parameters below or consult with a DMT technical representative. Rarely Reconfigured SPP-100 Parameters The SPP-100 configuration editor displays several parameters that you will rarely need to modify. The following is a list of these parameters and an explanation of what they do. Form DOC-0199 Rev A 6

Instrument #: This lists the number corresponding to the instrument you are viewing, typically the FSSP. If your FSSP has been assigned instrument number one, you will see 1 in this field. You should not need to modify the instrument number, and in fact you are unable to do so from within PADS. Baud Rate: The Baud rate for the probe is defined at manufacture. This parameter has been grayed out and you should not need to change it. If you reconfigure your hardware, however, the baud rate may change. Number of Droplets Used to Calculate Average Transit Time This control allows you to specify the number of particle readings that are used to calculate Avg_Transit, which is the average time it takes for particles to pass through the beam. ADC Threshold: The ADC Threshold indicates the smallest peak digital value a particle can have and still be sized by the instrument. Small digital peaks can occasionally occur in the absence of particles, and the ADC Threshold can be used to eliminate such noise. Channel Count: This number indicates how many sizing bins the SPP-100 uses to categorize particles. This number has been grayed out because it is preconfigured for your instrument and should not change. Divisor Flag: This selects the PHA divisor of basic clock speed to determine probe sampling speed. 0 = 20 MHz Sample Rate, 1 = 10 MHz Sample Rate. Use 20MHz sampling for airspeed of 40m/s or greater (airborne applications) DOF Reject: The DOF reject button tells the SPP-100 whether to reject particles that fall outside the SPP-100 s depth of field. The default value is true, and you should not need to change it. During probe calibration and alignment, DMT sets DOF Reject to false, so that the probe will report all particles it detects. (For a definition of Depth of Field, consult Appendix A: Definitions of the PADS Operator Manual.) Avg Trans Time Accept: This value sets the percentage of the transit time average that a particle transit must surpass before accepted. Count Method: If 0 is selected, the average transit is determined from the number of clock counts that the particle pulse is above the threshold. If 1 is selected, the average transit is determined by dividing the pulse area by the pulse peak. DMT advises using method 0. Transit Reject: If this button is ON, particles with transit times shorter than those specified by Avg Trans Time Accept will be excluded from average transit time calculations. This feature is designed to reject particles that may be undersized because they pass through the edge of the laser beam. When Transit Reject is enabled, the instrument measures the transit time of all particles that are accepted within the depth of field, maintains an average of their transit times, and then rejects individual particles whose transit times are less than the Form DOC-0199 Rev A 7

accepted percentage of this average. The theory is that if a particle s transit time is too short, the particle must have passed near the beam s edge. DOF [mm]: The length of the instrument s depth of field in mm. This parameter is set at manufacture and should not need to be changed. It is used in sample volume calculations. Beam Dia. [mm]: The diameter of the instrument s laser beam in mm. This parameter is set at manufacture and should not need to be changed. It is used in sample volume calculations. Beam Diameter (mm) * DOF (mm) * Beam Acceptance = Sample Area in mm 2. Range: The FSSP-100X, as built by the original manufacturer, has 4 size ranges. This setting allows the user to select the particle sensing range. Consult your original manual to determine the ranges. There is an Extended Range version of the FSSP. Threshold Tables: This field lists the path to the threshold table files. These files are used in sizing particles, and the SPP-100 has two threshold tables associated with it. (PADS only lists one of these tables in the Threshold Tables field, but both are in the directory.) SPP- 100_t.csv tells PADS the correct sizing bin for a particle given the peak digital value converted from the light scattered by the particle. SPP-100_p.csv tells PADS the upper size boundary in microns for each sizing bin. Note that the Thresholds Tables field should always be set to the SPP-100_t.csv file, and PADS finds the SPP-100_p.csv file automatically using the same path. While threshold tables have multiple rows, PADS only uses one row from each table. This data row has been chosen to work with your specific FSSP. The row changes with different Range selections. After making changes in the instrument configuration window, you will need to press the Save button and then click the green Reset Program to activate these changes. Clicking Reset Program will clear any data PADS is currently displaying. Configuring the SPP-100 Display To configure the SPP-100 display, click on the SPP-100 tab if you have not already done so. Then select Configure from the menu bar and click on Configure Display. This will bring up the following window. Form DOC-0199 Rev A 8

Figure 2: SPP-100 Display Editor Window You do not need to modify the Display # or Instrument #. Changing the Refresh Time allows you to set the time intervals for data display during acquisition mode; you can choose any time that is equal to or greater than the sample time. (Choosing a time less than the sample time is not useful, since the same data will be displayed multiple times.) When you are done, click on Save to update the configurations or Cancel to revert to the previous configuration. After you reset PADS, you will be able to see any changes you have made to Refresh Time. Note that clicking Reset Program will clear out any data currently being displayed. 3.0 The SPP-100 Window Figure 3 displays the SPP-100 window. Form DOC-0199 Rev A 9

Figure 3: SPP-100 Window The different parts of the SPP-100 Window are discussed below. For explanations of the Enable button, COM Port indicator, and Fault/No Fault button, see the Instrument Tabs section of the PADS Operator Manual. The Range buttons at the top left of the SPP_100 tab indicate which row in the thresholds table the program is using to bin particles. Clicking on another button allows you to change the range. Channel Data The SPP-100 channels are displayed in the data window in the left of the SPP-100 tab. These data are specific to the time listed in the upper-right of the PADS window. The SPP-100 channels are described in Appendices A and B of the PADS Operator Manual. Form DOC-0199 Rev A 10

Time-Series Chart Displays The SPP-100 chart displays are located on the top right of the window. Three tabs display number concentration (#/cm 3 ), volume concentration (µm 3 /cm 3 ), and total particle count. Histogram Data Window Below the SPP-100 chart displays is the histogram display of SPP-100-acquired particle data (Figure 4). Like the channel data display, the histogram shows time-specific data. Figure 4: SPP-100 Histogram Display with Scaling Buttons Note: The SPP-100 histogram does not label the x-axis with particle sizes. Rather, the x- axis labels display bin numbers, and corresponding particle sizes appear either above the data bars, as in Figure 4. On instruments with thirty bins, bins have a width ranging from 0.01 µm for small bins to 0.2 for large bins. This system enables the instrument to detect a wide size range of particles yet still provide nuanced sizing for smaller particles. As a result of the instrument s uneven bin sizes, the histogram distribution may not be a smooth curve. When the bin range increases, the bins capture many more particles. Figure 4 above, for instance, shows a jump in detected particles starting with bin 10, which has twice the width of the previous bin. If you want to see a normalized histogram curve, click on the Normalized button to the bottom left of the histogram. The normalization will take effect and you will see the Form DOC-0199 Rev A 11

distribution normalized by bin width. To normalize the data, PADS divides each bin count by the bin width in microns. If you enable the Log-Scale button, PADS will display histogram data logarithmically. The Autoscale button can be used to autoscale the y-axis. Form DOC-0199 Rev A 12

Appendix A: SPP-100 Channels A list of channels for a 30-bin instrument appears below. The SPP-100 output file will contain data values for each channel for each sampling instance. You can also plot each of these channels against time using the SPP-100 Selectable Charts tab. For definitions of the channels, consult Appendix A: Definitions in the PADS Operator Manual. For SPP100_MVD, see the MVD entry. For SPP100_ED, see the ED entry. Time Signal_Baseline (V) Annulus_Baseline (V) Aux_Analog_3 (V) Aux_Analog_4 (V) Laser_Reference (V) Aux_Analog_1 (V) Aux_Analog_2 (V) Electronics_Temp (C) Rej_DOF Rej_Avg_Trans Avg_Transit_Time (usec) FIFO_Full Reset_Flag ADC_Overflow Total Particle Events SPP_100_OPC_ch0 SPP_100_OPC_ch1 SPP_100_OPC_ch2 SPP_100_OPC_ch3 SPP_100_OPC_ch4 SPP_100_OPC_ch5 SPP_100_OPC_ch6 SPP_100_OPC_ch7 SPP_100_OPC_ch8 SPP_100_OPC_ch9 SPP_100_OPC_ch10 SPP_100_OPC_ch11 SPP_100_OPC_ch12 SPP_100_OPC_ch13 SPP_100_OPC_ch14 SPP_100_OPC_ch15 SPP_100_OPC_ch16 SPP_100_OPC_ch17 SPP_100_OPC_ch18 SPP_100_OPC_ch19 SPP_100_OPC_ch20 SPP_100_OPC_ch21 SPP_100_OPC_ch22 SPP_100_OPC_ch23 SPP_100_OPC_ch24 SPP_100_OPC_ch25 SPP_100_OPC_ch26 SPP_100_OPC_ch27 SPP_100_OPC_ch28 SPP_100_OPC_ch29 Number_Conc Volume_Conc SSP100_LWC SSP100_MVD SSP100_ED Beam_Acceptance Range Extended Range Status GPS_Time Form DOC-0199 Rev A 13

SPP-100 channels fall into several broad categories: Time Channels: The time channels store time data. Time is generated by the PADS computer clock and is the time when the program receives the instrument data. It is given in seconds after midnight on the day the program was started. GPS Time is included in every instrument s list of channels whenever a GPS is included as one of the PADS instruments. GPS Time may be collected from an instrument other than the instrument, even though it appears as a channel in the instrument output file. Housekeeping Channels: The SPP-100 s housekeeping channels are depicted in italics in the list above. These channels have a 0-10 V scale measured by a 12-bit A/D converter that gives integer values from 0 to 4095. Bin Channels: Channels labeled SPP_100_OPC_[i] store data on the number of particles of different sizes that the SPP-100 has detected. These data are used in the histogram display. Channels for Other Statistical Data: Rej_DOF, Rej_Avg_Transit, Avg_Transit, ADC_Overflow, Total Particle Events and Beam_Acceptance store particle statistics collected by the SPP-100. Status stores statistical data the SPP-100 has gathered on the communication between PADS and the probe. FIFO_Full stores data about the probe electronics. Configuration Channels: Range and Extended Range store information about the thresholds the SPP-100 uses to bin particles. SPP-100 Calculated Channels: Number_Conc, Volume_Conc, SPP100_LWC, SPP100_MVD, and SPP100_ED store the results of calculations PADS has performed on SPP-100 particle data. Obsolete, Reserved or Unused Channels: Reset_Flag is reserved for internal use. Aux_Analog channels are unused. Form DOC-0199 Rev A 14

Appendix B: Definitions for Channels Note: The following definitions are included in Revision H-5 and later of the PADS Operator Manual, DOC-0116. They are also listed in this appendix so that users who have an older copy of the PADS manual have access to them. Signal_Baseline (V): The filtered voltage registered by the sizing detector. This voltage will vary based on whether particles are present at the time of the reading. When no particles are present, the signal baseline should range from.29 -.33 volts. Annulus_Baseline (V): The filtered voltage registered by the annulus detector. This voltage will vary based on whether particles are present at the time of the reading. When no particles are present, the signal baseline should range from.29 -.33 volts. Laser_Reference (V): A channel that measures the laser power. The probe does not attempt to control laser power; instead, it uses laser power measurements to compensate for slight declines in power over time. This insures accurate particle measurements. However, if Laser_Reference (V) drops below 6 Volts, it is recommended you replace the laser. Rej_Avg_Trans: The number of particles that have been rejected for counting because they have passed through the edge of the laser beam and may be undersized. When Transit Reject is enabled, the instrument measures the transit time of all particles that are accepted within the depth of field, maintains an average of their transit times, and then rejects individual particles whose transit times are less than the accepted percentage of this average. The theory is that if a particle s transit time is too short, the particle must have passed near the beam s edge. Total Particle Events: The sum of bin counts plus Rej_Avg_Transit. Beam_Acceptance: An SPP-100 channel that stores the proportion of binned particles to total detected particles, i.e. the sum of bin counts divided by Total Particle Events. Range: A channel on the SPP-00 that indicates the row in the threshold table that the instrument currently uses for particle-size binning. Extended Range: A Boolean channel on the SPP-100. Extended Range is 1 if the Threshold Table being used is an extended range table, i.e. if the file name contains the string ER. Form DOC-0199 Rev A 15