User s Guide E-100BTX-FX-05(XLW) Stand-Alone Media Converter Fast Ethernet Copper to Fiber 100Base-TX to 100Base-FX Extended Temperature

Similar documents
User s Guide F-SM-MM-02 Stand-Alone Media Converter Fast Ethernet or ATM Singlemode to Multimode

Standard Temperature Models: media converters that can be used in a standard temperature environment from 0 C to 50 C (32 F to 122 F)

USER S GUIDE F-SM-MM-06 Stand-Alone Media Converter OC-12 ATM / SONET Singlemode to Multimode

User s Guide TN-J48xxx HP Compatible Small Form Factor Pluggables (SFPs) Transceiver Module

User s Guide SSETF10xx-205 Stand-Alone Media Converter Ethernet and Fast Ethernet 10/100Base-TX to 10/100Base-SX

USER S GUIDE SRS4Fxxxx-10x Stand-Alone Media Converter RS485/422 Copper to Fiber

USER S GUIDE SRS4Fxxxx-10x Stand-Alone Media Converter RS485/422 Copper to Fiber

User s Guide J/GE-CF-01(SX) Stand-Alone Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

USER S GUIDE CRS4Fxxxx-10x Slide-in-Module Media Converter RS485/422 Copper to Fiber

User s Guide J/RS232-xx-01 Stand-Alone Media Converter Just Convert-It RS-232 to Fiber

E-100BTX-FX-05 IN THE NETWORK

User s Guide CSETF10xx-205 Slide-in-Module Media Converter Ethernet and Fast Ethernet 10/100Base-TX to 10/100Base-SX

User s Guide SGETF10xx-1xx Stand-Alone Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

User s Guide M/E-ISW-FX-01(xxx) Series Stand-Alone Industrial Media Converters Copper to Fiber 10/100Base-TX to 100Base-FX

User s Guide SGETF10xx-10x Stand-Alone Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

USER S GUIDE NEC-FXE-xx-01, 100Base-FX Express Card

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

User s Guide CRS2F31xx-100 Slide-in-Module Media Converter RS-232 to Fiber

J/POE-CF-01 User s Guide

Port 2 - Duplex Fiber-Optic. 10/100/1000-Base-TX SGFEB

SPOEB10xx-100 User s Guide

User s Guide SBFTF10xx-10x Stand Alone Media Converter Copper to Fiber 10/100 Bridging (2 Ports) 10/100Base-TX to 100Base-FX

User s Guide CETTF * Slide-in-Module Media Converter Ethernet Copper to Fiber 10Base-T to 10Base-FL

M/E ISW FX 01 Series. User Guide. Contents. Introduction

User s Guide SRS2F Stand-Alone Media Converter RS-232 to Fiber

USER S GUIDE N-FXE-xxx-02, 100Base-FX Fiber Adaptor NIC Cards

ST, 850 nm multimode 2 km (1.2 miles)* SSDTF RJ-45. ST, 1310 nm single mode 8 km (4.8 miles)* SSDTF RJ km (5,000 feet) *

User s Guide TN-GB-SM512. Gigabit Interface Converter (GBIC) Transceiver Modules

User s Guide SPSVT26xx-10x Stand Alone Device High-Speed Serial V.35/X.21/RS449/RS530/RS232 Copper to Fiber

33415 Rev. B Page 1 of 22

SVIDF201x-100. SVIDF201x-110

User Guide SBFTF10xx-1xx Stand-Alone Media Converters

User s Guide C3110: Gigabit Ethernet Copper & Fiber Ports 1000Base-T to 1000Base-SX/LX Connectivity

T1/E1 Twisted-Pair Copper to Fiber Media Converters USER S GUIDE COMPLIANCE INFORMATION. SSDTF10xx*-100

User s Guide CGETF10xx-1xx Slide-in-Module Media Converter Gigabit Ethernet Copper to Fiber 1000Base-T to 1000Base-SX/LX

Part Number Port One - Copper Port Two - Duplex Fiber-Optic CSDTF ST, 850 nm multimode 2 km (1.2 miles)* CSDTF RJ-45 RJ-45

USER S GUIDE NEC-GXE-xx Base-X Fiber ExpressCard

M/E ISW FX 02 Series. Industrial Stand Alone Media Converters User Guide. Table of Contents

Compliance Information

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

M/GE-ISW-xx-01 User Guide. Contents. Introduction. Hardened Mini Gigabit Stand-Alone Media Converters

CAPTF33xx-1xx POTS to Fiber Optic Slide-In Card (SIC) User s Guide

User s Guide CMEFG10xx-1xx - Slide-in-Module SMEFG10xx-1xx - Stand-Alone Media Converters

Perle Fast Ethernet Media Converters

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

Perle Fast Ethernet Media Converters

2-Port Hub Type 1 2-Port Hub Type 3 Unshielded 2-Port Hub Type 3 Shielded

User Guide CPSVT26xx-10x Slide-in-Module Device

FIBER OPTIC A/B SWITCH (Non-latching)

43-MILLIMETER COMPATIBLE SWIPE READER TECHNICAL REFERENCE MANUAL

CrystalView DVI Micro-DL Extender

100-MILLIMETER COMPATIBLE SWIPE READER TECHNICAL REFERENCE MANUAL

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Synchronous Fiber Optic Modem

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

User Guide. TN-QSFP-40G-xx Cisco Compatible 40G QSFP+ Contents. Introduction

twister Mbps TX-to-FX Media Converter

Ethernet Media Converters

HD-One DX/DX500 HDMI Extender

MONOPRICE. BitPath AV VGA Extender over Single Cat6 Cable, 120m. User's Manual P/N 16226

E3/DS3 Fibre Extender

MONOPRICE. Blackbird 4K HDMI Extender. User's Manual P/N 24281

Owner s Manual. 10/100 Media Converters. Models: N SC-MM (850nm), N SC-15 (1310nm) 10/100/1000 Media Converters

TOURNAMENT NOISE CANCELLING MICROPHONE*

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

MONOPRICE. BitPath AV HDMI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16228

RS-232 Line Booster SERIAL CABLE BOOSTER CHASSIS GROUND TX DATA RX DATA RTS CTS DSR SIGNAL GROUND

Fibre Optic Modem ODW-622

twister Mbps Multimode-to-Singlemode Media Converter

RGBS Video Splitters MARCH 1994 AC063A AC063AE AC064A AC064AE AC065A AC065AE AC066A AC066AE

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

MONOPRICE. Blackbird 4K HDBaseT Extender Kit. User's Manual P/N 21792

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

Small Form-Factor Pluggable (SFP) Module Installation Guide

ODW-621. RS-232 Point-to-point applications

OptEnet OC48 Regenerator Module User Manual

MONOPRICE. BitPath AV SDI Extender over Single Cat6 Cable, 120m. User's Manual P/N 16227

Copyright Black Box Corporation. All rights reserved.

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

User Guide. HDMI Fiber Optic Extender. DVI-7350a

Single mode 9/125µm, duplex

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

Fibre Optic Modem ODW-611

MODEL UV232-16X UTP VGA/RS PORT SENDER. UMA1135, Rev 2 CUSTOMER SUPPORT INFORMATION

MONOPRICE. Blackbird 4K Pro HDBaseT Extender Kit. User's Manual P/N 21609

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

Installation. Step 1 Carefully unpack the package contents.

MONOPRICE. BitPath AV 4K 1X4 HDMI Splitter Extender over Single Cat6 with IR, 120m. User's Manual P/N 16286

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

LONWORKS Fibre Optic Converter

Transcription:

User s Guide E-100BTX-FX-05 Stand-Alone Media Converter Fast Ethernet Copper to Fiber 100Base-TX to 100Base-FX Extended Temperature Transition Networks E-100BTX-FX-05 Fast Ethernet media converters connect 100Base- TX shielded or unshielded twisted-pair copper cable to 100Base-FX fiber-optic cable. The E- 100BTX-FX-05 series media converters include both standard temperature models and extended temperature models. Standard Temperature Models: 0 C to 50 C (32 F to 122 F) Part Number E-100BTX-FX-05 E-100BTX-FX-05(SC) E-100BTX-FX-05(LC) E-100BTX-FX-05(MT) E-100BTX-FX-05(SM) E-100BTX-FX-05(SMLC) E-100BTX-FX-05(LH) E-100BTX-FX-05(XL) E-100BTX-FX-05(LW) E-100BTX-FX-05(XLW) Port One - Copper 100Base-TX Port Two - Duplex Fiber- 100Base-FX ST, 1300 nm multimode SC, 1300 nm multimode LC, 1300 nm multimode MT-RJ, 1300 nm multimode SC, LC, SC, 40 km (24.9 miles)* SC, 60 km (37.3 miles)* SC, 1550 nm single mode 80 km (49.7 miles)* SC, 1550 nm single mode 120 km (74.56 miles)* * Typical maximum cable distance. Actual distance is dependent upon the physical characteristics of the network installation. Installation.....................3 Operation.....................6 Cable Specifications..............8 Technical Specifications..........11 Troubleshooting...............12 Contact Us...................14 Compliance Information.........15

The media converters with the HT extension in the part number can be used in an extended temperature environment from -25 C to 65 C (-13 F to 149 F). Part Number E-100BTX-FX-05(HT) E-100BTX-FX-05(SCHT) E-100BTX-FX-05(SMHT) E-100BTX-FX-05(LHHT) E-100BTX-FX-05(XLHT) E-100BTX-FX-05(LWHT) E-100BTX-FX-05(100HT)** E-100BTX-FX-05(101HT)** Accessories sold separately Part Number SPS-1872-SA SPS-1872-CC E-MCR-05 WMBL WMBV WMBD WMBD-FS Description Port One - Copper 100Base-TX **E-100BTX-FX-05(100/101HT) are installed in pairs. Port Two - Duplex Fiber- 100Base-FX ST, 1300 nm multimode SC, 1300 nm multimode SC, SC, 40 km (24.9 miles)* Optional External Power Supply; 18-72VDC Stand-Alone Wide-Input; Output: 12.6VDC, 1.0 A Optional External Power Supply; 18-72VDC Piggy-Back Wide-Input; Output: 12.6VDC, 1.0 A 12-Slot Media Converter Rack (includes universal internal power supply) 17 x 15 x 5 in. (432 x 381 x 127 mm) Optional Wall Mount Brackets; 4.0 in. (102 mm) Optional Vertical Mount Bracket; 5.0 in. (127 mm) Optional DIN Rail Mount Bracket; 5.0 in. (127 mm) SC, 60 km (37.3 miles)* SC, 1550 nm single mode 80 km (49.7 miles)* SC, 1310Tx/1550Rx nm single mode SC, 1550Tx/1310Rx nm single mode Optional DIN Rail Mount Bracket (flat, small); 3.1in. (79 mm) Installation CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the 4-position DIP switch and jumpers. Failure to observe this caution could result in failure of the media converter. 4-position switch The 4-position DIP switch is located on the side of the media converter. Use a small flat-blade screwdriver or a similar tool to set the recessed switches. Auto-Negotiation (up=enable) Pause (up=enable) Link Pass-Through (up=enable) 1 2 3 4 Far End Fault (up=enable) 1. Auto-Negotiation up Enables Auto-Negotiation for the copper connection down Disables Auto-Negotiation for the copper connection 2. Pause Control up Enabled down Disabled 3. Link Pass-Through up Enabled down Disabled 4. Far-End Fault up Enabled down Disabled 2 techsupport@transition.com Click the Transition Now link for a live Web chat. 3

Installation Continued AutoCross Jumpers The AutoCross feature allows either straight-through (MDI) or crossover (MDI-X) cables to be used when connecting to devices such as hubs, transceivers, or network interface cards (NICs). AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up, regardless of the cable configuration. High-temperature board, J3, 3-Pin header settings: 1. Orient the board as shown in the photo. 2. Position the jumper as illustrated below the photo. High Temperature Device Installation Continued Installing the fiber cable 1. Locate a 100Base-FX compliant fiber cable with male, two-stranded TX to RX connectors installed at both ends. 2. Connect the fiber cables to the media converter as described: Connect the male TX cable connector to the female TX port. Connect the male RX cable connector to the female RX port. 3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described: Connect the male TX cable connector to the female RX port. Connect the male RX cable connector to the female TX port. SW1(4-Position) AutoCross 3-Pin Header set to Enabled J3 AutoCross 3-Pin Header Connect fiber cable to media converter as shown. Connect fiber cable to other device (media converter, hub, etc.) as shown J3 Enable AutoCross J3 Disable AutoCross RX TX RX TX Standard temperature board, J1, 3-Pin header settings: 1. Orient the board as shown in the photo. 2. Position the jumper as illustrated below. J1 AutoCross 3-Pin Header AC = AutoCross Enabled J1 Installing the copper cable 1. Locate a 100Base-TX compliant copper cables with male, connectors installed at both ends. 2. Connect the connector at one end of the cable to the port on the media converter. 3. Connect the connector at the other end of the cable to the port on the other device (switch, workstation, etc.). J1 AC = AutoCross Disabled port on the media converter port on the other device (switch, work station, etc.) 4 techsupport@transition.com Click the Transition Now link for a live Web chat. 5

Installation Continued Powering the media converter AC 1. Install the power cord barrel connector into the back of the media converter. 2. Connect the power adapter plug into AC power. 3. Verify that the media converter is powered up by observing the illuminated power indicator LED. DC Consult user guide 33266 for information on the SPS-1872-xx DC external power supply. Operation Status LEDs Use the status LEDs to monitor the E-100BTX-FX-05 media converter operation in the network: Power (Power) On = Connected to external AC power. SDF (Signal Detect/Fiber) On = Fiber link is detected. SDC (Signal Detect/Copper) On = Copper link is detected. RXC (Receive/Copper) Flashing = A signal is being received on the copper link. RXF (Receive/Fiber) Flashing = A signal is being received on the fiber link. Operation Continued Pause control The Pause feature can improve network performance by allowing one end of the link to signal the other to discontinue frame transmission for a set period of time to relieve buffer congestion. Note: If the Pause feature is available on ALL network devices attached to the media converter(s), enable the Pause feature on the media converter(s); otherwise, disable the Pause feature. Link Pass-Through The Link Pass-Through feature allows the media converter to monitor both the fiber and copper RX (receive) ports for loss of signal. In the event of a loss of an RX signal (1), the media converter will automatically disable the TX (transmit) signal (2), thus, passing through the link loss (3). The far-end device is automatically notified of the link loss (4), which prevents the loss of valuable data unknowingly transmitted over an invalid link. Near-End Device 1 original fault on the Ethernet copper link Far-End Fault Local Media Converter local converter sends a loss signal over the fiber link 2 4 fiber link is still valid Remote Media Converter Far-End Device 3 remote converter disables the Ethernet copper link When a fault occurs on an incoming fiber link (1), the media converter transmits a Far-End Fault signal on the outgoing fiber link (2). In addition, the Far-End Fault signal also activates the Link Pass-Through, which in turn disables the link on the copper portion of the network (3) and (4). Auto-Negotiation When the Auto-Negotiation feature is activated, the media converter configures itself to achieve the best possible mode of operation over a link, automatically. The media converter broadcasts its speed (100 Mb/s) and duplex capabilities (either fullor half-duplex) and negotiates the best mode of operation between the two devices. Near-End Device media converter A disables the copper link original fault on the fiber link 1 Media Converter A 4 2 Far-End Fault signal is sent Media Converter B Far-End Device 3 media converter B disables the copper link 6 techsupport@transition.com Click the Transition Now link for a live Web chat. 7

Cable Specifications The physical characteristics must meet or exceed IEEE 802.3 specifications. Fiber cable Bit Error Rate: <10-9 Single mode fiber (recommended): 9 µm Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm Extended temperature models E-100BTX-FX-05(HT) 1300 nm multimode Fiber Optic Receiver Sensitivity: min: -30.0 dbm max: -14.0 dbm 11.0 dbm E-100BTX-FX-05(SCHT) 1300 nm multimode Fiber Optic Receiver Sensitivity: min: -30.0 dbm max: -14.0 dbm 11.0 dbm E-100BTX-FX-05(SMHT) Fiber-optic Transmitter Power: min: -15.0 dbm max: -8.0 dbm Fiber-optic Receiver Sensitivity: min: -31.0 dbm max: -8.0 dbm 16.0 dbm E-100BTX-FX-05(LHHT) Fiber-optic Transmitter Power: min: -8.0 dbm max: -2.0 dbm Fiber-optic Receiver Sensitivity: min: -34.0 dbm max: -7.0 dbm 26.0 dbm E-100BTX-FX-05(XLHT) Fiber-optic Transmitter Power: min: -5.0 dbm max: 0.0 dbm Fiber-optic Receiver Sensitivity: min: -38.0 dbm max: -8.0 dbm 33.0 dbm E-100BTX-FX-05(LWHT) 1550 nm single mode Fiber-optic Transmitter Power: min: -5.0 dbm max: 0.0 dbm Fiber-optic Receiver Sensitivity: min: -34.0 dbm max: -7.0 dbm 29.0 dbm E-100BTX-FX-05(100HT) 1310Tx/1550Rx nm single mode E-100BTX-FX-05(101HT) 1550Tx/1310Rx nm single mode Fiber-optic Transmitter Power: min: -14.0 dbm max:-8.0 dbm Fiber-optic Receiver Sensitivity: min: -33.0 dbm max: -3.0 dbm 19.0 dbm Cable Specifications continued Standard models E-100BTX-FX-05 1300 nm multimode Fiber Optic Receiver Sensitivity: min: -30.0 dbm max: -14.0 dbm 11.0 dbm E-100BTX-FX-05(SC) & (LC) 1300 nm multimode Fiber Optic Receiver Sensitivity: min: -30.0 dbm max: -14.0 dbm 11.0 dbm E-100BTX-FX-05(MT) 1300 nm multimode Fiber Optic Receiver Sensitivity: min: -33.5 dbm max: -14.0 dbm 14.5 dbm E-100BTX-FX-05(SM) Fiber-optic Transmitter Power: min: -15.0 dbm max: -8.0 dbm Fiber-optic Receiver Sensitivity: min: -31.0 dbm max: -8.0 dbm 16.0 dbm E-100BTX-FX-05(SMLC) Fiber-optic Transmitter Power: min: -15.2 dbm max: -8.0 dbm Fiber-optic Receiver Sensitivity: min: -32.5 dbm max: -3.0 dbm 17.3 dbm E-100BTX-FX-05(LH) Fiber-optic Transmitter Power: min: -8.0 dbm max: -2.0 dbm Fiber-optic Receiver Sensitivity: min: -34.0 dbm max: -7.0 dbm 26.0 dbm E-100BTX-FX-05(XL) E-100BTX-FX-05(LW) 1550 nm single mode Fiber-optic Transmitter Power: min: -5.0 dbm max: 0.0 dbm Fiber-optic Receiver Sensitivity: min: -34.0 dbm max: -7.0 dbm 29.0 dbm E-100BTX-FX-05(XLW) 1550 nm single mode Fiber-optic Transmitter Power: min: 0.0 dbm max: 5.0 dbm Fiber-optic Receiver Sensitivity: min: -36.0 dbm max: -3.0 dbm 36.0 dbm The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11. 8 techsupport@transition.com Click the Transition Now link for a live Web chat. 9

Cable Specifications Continued Copper cable Category 5: (minimum requirement) Gauge: 24 to 22 AWG Attenuation: 22.0 db /100m @ 100 MHz Maximum Cable Distance: 100 meters Straight-through or crossover cable may be used. Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) may be used Pins 1&2 and 3&6 are the two active pairs in an Ethernet network. Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD- Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange, etc.) Do not use flat or silver satin wire. Twisted Pair #1 Twisted Pair #2 Straight-Through Cable Twisted Pair #1 Twisted Pair #2 Crossover Cable Technical Specifications For use with Transition Networks Model E-100BTX-FX-05(xxxx) or equivalent Data rate: 100 Mb/s Dimensions: 4.75" x 3.0" x 1.0" (119mm x 76mm x 25mm) Weight: 6 oz. (181 g) approximately MTBF: Greater than 41,680 hours (MIL-HDBK-217F) Greater than 114,580 hours (Bellcore7 V5.0) Power supply (standard temperature) 12 VDC, 0.5 A (minimum) DC output: (extended temperature) 9 VDC, 1.0 A (minimum) minimum output regulation: 5% Environment: Tmra* (standard temp): 0 C to 50 C (32 to 122 F) Storage Temperature: -15 C to 65 C (5 to 149 F) Tmra* (extended temp): -25 C to 65 C (-13 to 149 F) Storage Temperature: -25 C to 65 C (5 to 149 F) Humidity: 10% 90%, non-condensing Warranty: Lifetime *Manufacturer s rated ambient temperature. CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or view directly with optical instruments. CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure. CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intrabuilding (inside plant) link segments that are not subject to lightening transients or power faults. Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are T to be connected to inter-building (outside plant) link segments that are subject to lightening transients or power faults. Failure to observe this caution could result in damage to equipment. 10 techsupport@transition.com Click the Transition Now link for a live Web chat. 11

Troubleshooting If the media converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action: Note: DIP switch positions 3 and 4 must be DOWN before starting the troubleshooting process. 1. Is the Power LED illuminated? Is the power adapter the correct model (check I/O voltage and Hz)? Verify the voltage and frequency of the AC outlet? Are the power barrel connector and wall plug of the power adapter properly inserted in the media converter and plugged into the AC wall outlet? Proceed to step 2. 2. Is the SDC (signal detect/copper) LED illuminated? Check the twisted-pair cables for proper connection. Proceed to step 3. Name of Mfg: Model Number(s): Declaration of Conformity Transition Networks 10900 Red Circle Drive, Minnetonka MN 55343, U.S.A. E-100BTX-FX-05, E-100BTX-FX-05(SC), E-100BTX-FX-05(LC), E-100BTX-FX-05(MT), E-100BTX-FX-05(SM), E-100BTX-FX-05(SMLC), E-100BTX-FX-05(LH), E-100BTX-FX-05(XL), E-100BTX-FX-05(LW), E-100BTX-FX-05(XLW) E-100BTX-FX-05(SMHT), E-100BTX-FX-05(HT), E-100BTX-FX-05(LHHT), E-100BTX-FX-05(XLHT), E-100BTX-FX-05(LWHT), E-100BTX-FX-05(SCHT) E-100BTX-FX-05(100HT), E-100BTX-FX-05(101HT) Purpose: To declare that the E-100BTX-FX-05(xxxx) to which this declaration refers is in compliance with the following directive(s) and standard(s): EMC Directive 2004/108/EC; EN 55022:2006+A1:2007 Class A; EN55024:1998+A1:2001+A2:2003; EN6100-2-3; EN6100-3-3; CFR Title 47 Part 15 Subpart B Class A. Low Voltage Directive: 2006/95/EC; IEC 60950-1:2005; CFR Title 21 Section 1040.10 Class I; UL Listed; C-UL Listed; CE Mark I, the undersigned, hereby declare that the model number(s) listed in this declaration of conformity are in compliance with the directive(s) and standard(s) herein. Stephen Anderson, Vice-President of Engineering February, 2010 Date 3. Is the SDF LED (signal detect/fiber) illuminated? Check the fiber cables for proper connection. Verify that the TX and RX cables on the media converter are connected to the RX and TX ports, respectively, on the other device. Proceed to step 4. 4. Is the RXC (receive/copper) LED flashing? If there is no activity on the UTP/STP port, proceed to step 5. If there is activity on the UTP/STP port, disconnect and reconnect the twisted-pair cable to restart the initialization process. Proceed to step 5. 5. Is the RXF (receive/fiber) LED flashing? If there is no activity on the fiber port, contact Tech Support. If there is activity on the fiber port, disconnect and reconnect the fiber cable to restart the initialization process. 12 techsupport@transition.com Click the Transition Now link for a live Web chat. 13

Contact Us Compliance Information Technical support Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600 Transition now Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Tech Support/Transition Now link. Web-based seminars Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link. E-Mail Ask a question anytime by sending an e-mail to our technical support staff. techsupport@transition.com Address Transition Networks 10900 Red Circle Drive, Minnetonka, MN 55343, U.S.A. telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322 FCC regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense. Canadian regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. European regulations Warning This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich. Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées. In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003, Transition Networks will accept post usage returns of this product for proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document. CAUTION: RJ connectors are T INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network. Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG- Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität. 14 techsupport@transition.com Click the Transition Now link for a live Web chat. 15

Trademark notice All trademarks and registered trademarks are the property of their respective owners. Copyright restrictions 2003-2010 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks. Printed in the U.S.A. 16 33210.P